HomeMy WebLinkAboutBLD10-228City of Port Townsend Development Services Department Correction Notice PERMITNUMBER |O- 222 OWNER amet JOB LOCATION Inspection of this structure has found the following violations: Ly Yak J Ve ZL w WM ASIAN to lve as entra Wasuavy Kive pl sk Us Yolo. WED ¥ AX eve, ek Remmued BA Swole LZ ow Calves, il aN War. nat é L L OG te slo dvdlh all ler Averys excupx Fe alae » L L L < o You are hereby notified that no more work shall be done upon these premises until the above violations are corrected, unless noted otherwise. When corrections have been made, call for inspection. . Date 2- 24 - Ul Inspector Melman DSD Main Office (360) 379-5095 INSPECTION REQUEST (360) 385-2294 | THIS NOTICE MUST BE KEPT WITH APPROVED PLANS ON SITE | CONSTRUCTION PROGRESS RECORD CITY OF PORT TOWNSEND Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 POST THIS CARD IN A SAFE, CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE. PARCELNO. 988801303 — PERMIT NO. BLD10-228 ISSUED DATE _ 04/06/2011 EXPIRATION DATE __07/05/2011 ADDRESS 921 TAYLOR ST CONSTRUCTION TYPE _V-B OCCUPANT LOAD OWNER BIMEL MARGARET A PROJECT DESCRIPTION Remove and replace fire damaged building components. F CONTRACTOR BLUE EARTH BUILDERS LLC LENDER INSPECTION INSP DATE COMMENT INSPECTION INSP DATE COMMENT SETBACKS SURVEY PIN oN 1 i FOOTING oe Z a hes ae Le Yie/u wer a Bey SRAUWALL Fru omhl parse FLOOR FRAMING twa | 2/1, An L 2/f wpa FRAMING Wink] 276A, 7TH PLUMBING LY ac, MECHANICAL wha] “Av/}, Kyu Can/ INSULATION Wadh {74 Picceph Aver Arusurk hve glace Sea Caweckler - GWB (Wx 726) ROOF NAILING ad MISCELLANEOUS WMA Wez/| INsul, Cek, Te Atle, FINALBLDG./C OFO |\Mndt Ye/| U = TO REQUEST AN INSPECTION CALL (360) 385-2294. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 3:00 PM FOR NEXT DAY INSPECTION. BUILDING PERMIT City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Project Information Permit # BLD10-228 Permit Type Residential - Addition/Remodel Project Name Remodel / Fire Damage Site Address 921 TAYLOR ST Parcel # 988801303 Project Description Remove and replace fire damaged building components. Rebuild and enclose front porch. Names Associated with this Project License Type Name Contact Phone # Type License # Exp Date Applicant Bimel Margaret A Owner Bimel Margaret A Representative Dickson O David Contractor Blue Earth Builders Llc Q- CITY 2010 355 5985 12/31/2011 Contractor Blue Earth Builders Llc 0 - STATE BLUEEEB904P 10/22/2012 Fee Information Project Details Project Valuation $66,850.92 Dwellings - Remodel @ 80% 878 SQFT PLAN REVIEW REFUND 150 “150.00 Units: 1 Heat Type: ELECTRIC BBH PLAN REVIEW REFUND 50 -50.00 Bedrooms: 2 Construction Type: V - B PLAN REVIEW DEPOSIT 50 50.00 Bathrooms: 1 Occupancy Type: R-3 PLAN REVIEW DEPOSIT 150 150.00 Building Permit Fee 762.75 Plan Review Fee 495.79 Technology Fee for Building Permit 15.26 State Building Code Council Fee 4.50 Record Retention Fee for Building 10.00 Permit Total Fees $ 1,288.30 *** SEE ATTACHED CONDITIONS *** Call 385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify that I am the owner of the property thorized agent of the owner. x Print Name Na JS CASO Date Issued: 01/06/2011 AN : Issued By: MWAY Signature Wan \ » choo Date [- ls 2) l ( Date Expires: 07/05/2011 BUILDING PERMIT City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Project Information Permit # BLD10-228 Permit Type Residential - Addition/Remodel Project Name —_ Remodel / Fire Damage Parcel # 988801303 Site Address 921 TAYLOR ST Project Description Remove and replace fire damaged building components. Rebuild and enclose front porch. Conditions 10. Property corner survey pins must be located at time of footing inspection to verify setbacks. Call 385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify that I am the owner of the property or authorized agent of the owner. Date Issued: 01/06/2011 Print Name Issued By: MWAY Date Date Expires: 07/05/2011 Signature PERMIT# @ 0 s\0—22& CITY OF PORT TOWNSEND BLDG PERMIT ACTIVITY LOG DATE RECEIVED_|2—2\—9 SCOPE OF WORK: Remmoe + Verlace Hive damaged buildiag Campaneral S Ve-ouild_s enuoge. Hvter C/N DATE ACTION INITIALS {2 241-8 ENTERED INTO CHET (AWW Wa 2 Pan () | CHECKED FOR COMPLETENESS MV Plan Review # Bedroom(s) = # Bath(s) = Heat Type: \2-24-1d CiSy UB Ie8s UcerBe 40 be avolied fw _dn-\ine {Mu joven “OAOLY | 1Dd/9q [10 Met cantly, an ch Die KSow “To disc vss Bl choy pluos, Clwges , rfUAs awed, were ( sulbarrt Neu) pluns eel WLTA Plow vei Pia? Complete changes Au ne ee aN pauce mT Pluss FA \ Ci Q) uesktars 3 - Co Ccete Portela Wwasuncert-ed ( Come hes) Sw sj 2s) Qo! ce balding cod \ +to Ln cioye [ace KLE gd : te mnalee ce MA ‘Lo: fom Lat wal tp pra. Neg. Plog Chote Cdewalle + not ppp, line . How did he pire pear pap ling Fence” Arn Oms 7 towd a ut of Blarey £ eos Of, wha ‘oloat Qackinp ? No omtile-nover hac. Lis Nouce ue next doar- Uo Lous Lor Pra Kyond at P (tere chon of Blaire— “they eee twir 6 thoy at { perky jp SEPTIC? Wo Zoning: Kt . a Setbacks OK? laa S bor: Porthe,- in thorn Shown... ole Lot Size: %O Xo - ‘ZZO0_ (sup Standard Lot] _ Building Size: dhol PET PREZ550, : Aww focal 32) = Kee Lot Coverage: oT V°/o “EXg FAR OK? Ue. . Height OK? a Z Parking OK? |= hee is it -( Nower has Wad da-sike par luce, a Critical Area? ’ \ 4 ds (Check 6) mon Impervious px Surface limits 19.05.050D4(a) Shorelines Jurisdiction? No. Demo? Inc ude LA VARY} Se Historic Rev/ tse alt wm \GW0" p per PS SeSS0r. Design Rev? ai Notice to Title? Lots of Record? t ; Vv ~ \ 1 Der 17.8 G30. A -1F Camoed ty "2 or murre oF reple Omen Cask Sloped only (ec coneyrms el O K ) P:\DSD\Forms\General Use Forms\Activity Log Bldg Permit.doc July 12, 2010 Development Services a Street, Suite 3: Residential Building Permit Application Legal Description (or Tax#) Project Addr : ~~ 14 Tor lov-st, Addition: Plummey'S Zoning: ee Block: | 3 Parcelt# ABS¥YO 13O3 Lot (s):___&# é ~ Project Description: @ WMOye- on) a Croce 4: ce os RyilS WA comPueutS ~ re Ry, (> L\ 7 Qn close. ont ir A Applications by mail must include a check for initial plan review fee of $150 for projects valued over $15,000. See Page 2 for details on plan submittal requirements. Property Owner/Applicant Building Information (square feet): Name: _ ov owe et el 1* floor BID Garage: Address: At try lw St. = 2" floor Carport: City/StiZip:_ Poth son Gew/ WA. GREG 3" floor ———S—S«Ctheer: Phone: Email: Basement V/A Finished: Unfinished: ontact en esentative: = TT Name: O CK LOW xal-2* \S Decks / Porches Phone: 260 IF HSH - =~) Covered: Uncovered Email: O Nwid/ o a) MSN. LOM Heat Type: _—horpet! a jh pa r a l Contract Ss Electric ~<___ Heat Pump Other ontractor: ame as stand Name: re lve. £ awin te AE ‘(Der < WA Total: #Bedrooms ay #Bathrooms | Address: +¥L OPK Hwy IO IO | | City/St/Zip: Portdtoy nSom): wh. AZACK Size of ot SROO_ Square feet Phone: 3] 6 ( +5 (% wee Total Lot Coverage (Building Footprint):* Square feet: BS % V7, i Impervious Surface:* Square feet: SO *Total existing & proposed Email: David. /V. Dickson, wv Lawn. L col State License # RBLUEEE RI0u Exp: City Business License #: Lender Information: What year was the structure built? { j SG U Lender information must be provided for projects over If work includes demolition, see Page 2 $5,000 in valuation per RCW 19.27.095. , oP es Name: t4Se “ONE, Ome, £6 YVeIuAC Y Any known wetlands on the property? Y ) Project Valuation: $ /OO OOO * Any steep slopes (>15%)? Y | hereby certify that the information provided is correct, that | am either the owner or authorized to act on behalf of the owner and that all activities-associated ae re will be in a with State Laws and the Port Townsend Municipal Code. Print Name: alex Vr Signature: \\owe / c\. Te Date: Wee | Oo (CO Page 1 of 2 - 1/4/2010 -OVER- RESIDENTIAL BUILDING PERMIT APPLICATION CHECKLIST This checklist is for new dwellings, additions, remodels, and garages. 0 Residential permit application. 0 Washington State Energy & Ventilation Code forms 0 Two (2) sets of plans with North arrow and scaled, no smaller than ‘4” = 1 foot: OA site plan showing: 1. Legal description and parcel number (or tax number), 2. Property lines and dimensions 3. Setbacks from all sides of the proposed structure to the property lines in accordance with a pinned boundary line survey 4. On-site parking and driveway with dimensions 5. If creating new impervious surfaces, indicate measures utilized to retain stormwater on-site 6. Street names and any easements or vacations 7. Location and diameter of existing trees 8. Utility lines 9. If applicable, existing or proposed septic system location 10. Delineated critical areas boundaries and buffers 0 Foundation plan: 1. Footings and foundation walls 2. Post and beam sizes and spans 3. Floor joist size and layout 4. Holdowns 5. Foundation venting 0 Floor plan: 1. Room use and dimensions 2. Braced wall panel locations 3. Smoke detector locations 4. Attic access 5. Plumbing and mechanical fixtures 6. Occupancy separation between dwelling and garage (if applicable) 7. Window, skylight, and door locations, including escape windows and safety glazing 0 Wall section: 1. Footing size, reinforcement, depth below grade 2. Foundation wall, height, width, reinforcement, anchor bolts, and washers 3. Floor joist size and spacing 4. Wall stud size and spacing 5. Header size and spans 6. Wall sheathing, weather resistant barrier, and siding material 7. Sheet rock and insulation 8. Rafters, ceiling joists, trusses, with blocking and positive connections Ceiling height 10. Roof sheathing, roofing material, roof pitch, attic ventilation CO Exterior elevations (all four) with existing slope of the land in relation to all proposed structures 0 If architecturally designed, one set of plans must have an original signature 0 If engineered, one set of plans must have one original signature 0 For new dwelling construction, Street & Utility or Minor Improvement application © . If you are proposing partial or full demolition of a structure that is at least 50 years old, per Ordinance 2969 Historic Preservation Committee (HPC) review is required. If within the National Historic Landmark district: $58.00 for full committee review. If outside the National Historic Landmark district and not on the Historic Register: no fee for HPC Administrative review. Complete HPC Form. Partial demolition includes exterior demolition for additions and remodels. Page 2 of 2 - 1/4/2010 -OVER- Contractors or Tradespeople iil Washington State Department of Labor & Industries Contractors or Tradespeople Detail Return to List > Start a New Search > ye Printer friendly Verify Workers' Comp Premium Status Page 1 of 2 Coury Vicerise f8 '9e age lied fv I Wwe \2--2|-Lo Check for Dept. of Revenue Account About General/Specialty Contractor A business registered as a construction contractor with L&I to perform construction work within the scope of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment of account and carry general liability insurance. Business and Licensing Information Name BLUE EARTH BUILDERS LLC UBI No. ij 603051167 Phone No. (360) 301-1297 Status RS) Active Address 282084 Us Hwy 101 Suite /Apt. License No. BLUEEFEB904P2 City Port Townsend License Type ij Construction Contractor State WA - Effective Date 10/21/2010 Zip 98368 Expiration Date 10/22/2012 County Jefferson . Suspend Date yy Business Type Limited Liability Company Parent Company Specialty | ij General Specialty 2 y Unused {=} Other Associated Licenses Special Special Effective Expiration License Name Type P Y P a e Status 1 2 Date Date pickseco3sog DICKSON BROS Ronstuction General Unused 9/18/2007 9/18/2009 _ Expired DICKSBC9350Q CONSTRUCTION Contractor _ f=} Business Owner Information =| Hide All Name Role Effective Date Expiration Date DICKSON, JOHN W Partner /Member 10/21/2010 DICKSON, DAVID N Partner /Member 10/21/2010 8 Bond Information y Bond Bond Company Bond Account Effective Expiration Cancel Impaired Bond Received https://fortress.wa.gov/Ini/bbip/Result.aspx 12/21/2010 City of Port Townsend TABLE 17.16.030 Residential Zoning Districts - Bulk, Dimensional and Density Requirements DISTRICT R-I rT R-Ill R-IV MAXIMUM HOUSING 4 dwelling units (Multiple 8 dwelling units tiple 16 units per 40,000 sf 24 units per 40,000 sf DENSITY (units per dwelling units on a single dwelling units on a single of lot area of lot area 40,000 square foot lot must be contained lot must be contained area) within a single structure, within a single structure, except: a permitted except: a permitted accessory dwelling unit accessory dwelling unit (ADU) may be established | (ADU) may be established in a separate building if in a separate building if allowed by PTMC allowed by PTMC 17.16.020) 17.16.020) (10,000 sf of lot area per (5,000 sf of lot area per unit) unit) MINIMUM AVERAGE 10 units where a parcel 15 units HOUSING DENSITY and/or contiguous (units per 40,000 parcels under single square foot area) ownership are 12,000 square-feet in size or greater MAXIMUM NUMBER 4 (Note: limited structures | 4 (Note: limited structures No limit No limit OF DWELLING with more than 4 dwellings | with more than 4 dwellings UNITS IN ANY ONE per structure may be per structure may be STRUCTURE permitted through the PUD permitted through the process, see Chapter 17.32 PUD process, see PTMC.) Chapter 17.32 PTMC.) MINIMUM LOT SIZE 10,000 sf = single-family 5,000 sf = single-family 3,000 sq ft = single- detached detached family detached; 5,000 sf = single-family attached (duplex); 7,500 sf = single-family attached (triplex); and 10,000 sf = single- family attached (fourplex) and multi- family’ MINIMUM LOT 50’ 50’ 30’ except: 100’= WIDTH Z\ multifamily MINIMUM FRONT 20’ except: 10/except 20’ for garages 20’ except: 20’ except; YARD SETBACKS 50’= barns and agricultural h vehicle access facing 10’ w/ side or rear 10’ w/side or rear buildings a street right-of-way and parking/garages; parking; no setback for 50’=barns and agricultural garages with vehicle multifamily structures buildings access facing a street located within 200’ of right-of-way must be an abutting mixed use setback 20’; no setback zoning district for multifamily structures located within 200’ of an abutting mixed use zoning district See Back of This Page For More "In order to achieve the minimum density, subdivision of parcels 12,000 square-feet or greater shall not allow individual lots larger than 4,000 square-feet unless said lots are reserved for multi-family dwellings. P:ADSD\Forms\Building Forms\Information-Table 17.16.030 Res Zoning Districts 9-2010.doc Page 1o0f 2 09/22/10 City of Port Townsend TABLE 17.16.030 Residential Zoning Districts - Bulk, Dimensional and Density Requirements other side; 10’= abutting a street r-o-w; 20’ for garages with vehicle access facing a street right- of-way and 50’ barns and agricultural buildings and 100’ if abutting a R-II, R-Ill, or R-IV zoning district other side; 10’= abutting a street r-o- w; 20’ for garages with vehicle access facing a street right-of-way and 100’= barns and agricultural buildings DISTRICT R-I pR.4 R-Ill R-IV MINIMUM REAR 20’ except: 10’ except: 10’ except: 15’ except: YARD SETBACKS 50’ = barns and agricultural 100’ = barns and no setback for 20’ if directly abutting buildings, and 100’ if agricultural buildings multifamily structures an R-I or R-II district; abutting a R-II, R-Ill, or located within 200’ of an no setback for R-IV zoning district abutting mixed use multifamily structures zoning district located within 200’ of an abutting mixed use zoning district MINIMUM SIDE 15’ minimum total with 15’ minimum total with 5’ except: 15’ except: YARD SETBACKS 10’minimum on one side, 10’minimum on one side, 10’= along a street r-o- | 20’ if directly abutting and 5’ minimum on the and 5’ minimum on the w; 20’ for garages with an R-1 or vehicle access facing a street right-of-way and no setback for multifamily structures located within 200’ of an abutting mixed use zoning district R-II district; no setback for multifamily structures located within 200’ of an abutting mixed use zoning district MODULATION ON PRIMARY STREET FAGADE without modulation = 20’; minimum modulation depth = 2’; minimum modulation width = 8’ without modulation = 20’; minimum modulation depth = 2’; minimum modulation width = 8’ MAXIMUM BUILDING 30’ 30’ 35’ 35’ HEIGHT MAXIMUM LOT 25% 35% except 40% where 45% 50% COVERAGE an ADU is included on the lot MINIMUM Maximum wall length Maximum wall length Not applicable Not applicable MAXIMUM FENCE HEIGHT* Front=4’; Side=8’; Side abutting a public right-of- way =4’; rear=8’ Front=4’; Side=8’; Side abutting a public right-of- way = 4’; rear=8’ Front=4’; Side=8’; Side abutting a public right- of-way =4’; rear=8’ Front=4’;Side=8’; Side abutting a public right-of-way =4’; rear=8’ * NOTE: Maximum fence heights apply within any required front, side, or rear setback area or along the edge of any required yard; refer to Chapter 17.68 PTMC, Fences, Walls, Arbors, and Hedges for specific requirements. (Ord. 3038 § 8, 2010; Ord. 2982 § 2, 2008; 2967 § 4.2, 2008; Ord. 2939 §§ 1, 2, 2007; Ord. 2913 § 2, 2005; Ord. 2825 § 4, 2003; Ord. 2782 § 4, 2001; Ord. 2716 § 4.3, 1999; Ord. 2700 § 11, 1999; Ord. 2571 § 2, 1997). P:\DSD\Forms\Building Forms\Information-Table 17.16.030 Res Zoning Districts 9-2010.doc Page 20f 2 09/22/10 Wa s t e Wa t e r St o r m Wa t e r 1 in c h = 16 . 6 6 6 6 6 7 fe e t an “a s is, ” “w i t h al l fa u l t s , ” To w n s e n d an d do no t wa r r a n t in an y wa y th e ac c u r a c y of th e nt a i n e d in th i s ma p . Fi e l d ve r i f i c : of th e ac c u r a c y of al l ma p in f o r m a t i o n is th e so l e re s p o n s i b i l i t y of th e us e r t re l e a s e s th e Ci t y of Po r t To w n s e n d an d it s em p l o y e e s fr o m an y li a b ba s e d on us e r ’ s us e of ma p i i Receipt Number: BLD10-228 988801303 Plan Review Fee $495.79 $495.79 $0.00 BLD10-228 988801303 PLAN REVIEW DEPOSIT 50 $50.00 $50.00 $0.00 BLD10-228 988801303 PLAN REVIEW REFUND 50 -$50.00 -$50.00 $0.00 BLD10-228 988801303 PLAN REVIEW REFUND 150 -$150.00 -$150.00 $0.00 BLD10-228 988801303 Building Permit Fee $762.75 $762.75 $0.00 BLD10-228 988801303 State Building Code Council Fee $4.50 $4.50 $0.00 BLD10-228 988801303 Technology Fee for Building Permit $15.26 $15.26 $0.00 BLD10-228 988801303 Record Retention Fee for Building Per $10.00 $10.00 $0.00 Total: $1,138.30 10-0939 12/21/2010 | PLAN REVIEW DEPOSIT 150 $150.00 BLD10-228 CHECK 5152 $1,138.30 Total: $1,138.30 genpmtrreceipts Page 1 of 1 Receipt Number: BLD10-228 988801303 PLAN REVIEW DEPOSIT 150 $150.00 $150.00 $0.00 Total: $150.00 CHECK 5151 . $ 150.00 Total: $150.00 genpmtrreceipts Page 1 of 1 Tracy’s Insulation Inc. “INSULATING YOUR COMMUNITY” P.O. BOX 567 PORT ANGELES, WA 98362 INSULATION CERTIFICATE THE INSULATION HAS BEEN INSTALLED IN CONFORMANCE WITH THE CURRENT THERMAL PERFORMANCE STANDARDS (WASHINGTON STATE ENERGY CODE) OR PER APPROVED PLANS, AT THE ADDRESS LOCATED BELOW. oF —— ADDRESS A2al Taulov Street SUB- CONTRACTOR: TRACY’S INSULATION INC. CONTRACTOR’S REG. NO. TRACYII917BT MANUFACTURER THICKNESS R-VALUES EXTERIOR WALLS ¥ 1! P Type of material: Fiberglass Kin couct > ; re LZ. ~) \ ATTIC BATTS N | A Type of material: Fiberglass \i c= : Ze WS a —_ - , iA DE S rT A\ \ WH ) ; i pw AW wT Wy / ys ra m 4 > Z f MS wz yy SLOPED/VAULTED CEILINGS / AN Type of material: Fiberglass IN >?) VON Foauw ATTIC BLOW KB ASE Type of material: Fiberglass FLOORS F bry) Type of material: Fiberglass K wc A L it \ (\ oS Za E= MY wy SS oS Pr oS MZ PIPE WRAPS Type of material: Fiberglass YES a NO VAPORBARRIERS CEILING | Watts NY [he FLOORS (¢ MIL ZL MU nl l i Saidle me Ottioe Assistant 4 {iq ti AUTHORIZED SIGNATURE A.B. ANCHOR BOLT ELF. EXHAUST FAN INSUL. INSULATION REINF. REINFORCED ABV. ABOVE EJ. EXPANSION JOINT INT. INTERIOR REQ D. REQUIRED ADU ACCESSORY DWELLING UNIT E.N. END NAILING JST. JOIST RE:. RETURN AVG. AVERAGE E.W. EACH WAY KD KILN DRIED REV. REVISION BLK. BLOCK EA. EACH LFT. LINEAR FEET RM ROOM BM. BEAM ELECT. "ELECTRIC, ELECTRICAL” LAM. LAMINATE S.D. SMOKE DETECTOR BRG. BEARING EQ. EQUAL UN. UNEAR SC SELF CLOSING Cu. CONTROL JOINT EST. ESTIMATE UNO. LINOLEUM SCHED. SCHEDULE CAB. CABINET EXC. EXCAVATE LVL LAMINATED VENEER LUMBER SECT. SECTION CFM CUBIC FEET PER MINUTE XH. EXHAUST MAX. MAXIMUM SHTG. SHEATHING CL or C CENTERLINE EXIST. or (E) EXISTING MECH. MECHANICAL SIP STRUCTURAL INSULATED PANELS CLG. CEILING EXT. EXTERIOR MFR. MANUFACTURER SPecS SPECIFICATIONS CLKG. CAULKING F.D. FLOOR DRAIN MIN. MINIMUM STC SOUND TRANSMISSION CLASS CLO. CLOSET F.N. FIELD NAILING MIL. METAL STD. STANDARD CLR. CLEAR F.0. FACE OF N.T.S. NOT TO SCALE STL. STEEL CMU CONCRETE MASONRY UNIT F/G FIBERGLASS 0.C. ON CENTER TEMP. TEMPERED or TEMPORARY CNTRD. CENTERED FAB. FABRICATE 0.H. OVER HANG T&G TONGUE AND GROOVE COL. COLUMN FDN. FOUNDATION OPNG. OPENING T.0. TOP OF CONC. CONCRETE FL FLOOR P.L. or ® — PROPERTY LINE T.0.B. TOP OF BEAM CONST. CONSTRUCTION FLG. FLOORING P.0.C. POINT OF CONNECTION T.0.C. TOP OF CURB CONT. CONTINUOUS FLUOR. FLUORESCENT PERF. PERFORATED T.0.F. TOP OF FOOTING D.S. DOWN SPOUT FTG. FOOTING PERP. or L PERPENDICULAR T.G.u. TOP OF JOIST D DISHWASHER GALV. GALVANIZED PLYWD. PLYWOOD T.O.S. TOP OF SLAB DBL. DOUBLE GLB GLUE LAMINATED BEAM PREF AB. PREFABRICATED T.0.W. TOP OF WALL DEMO DEMOLITION GYP. BD. GYPSUM BOARD PSF POUNDS PER SQUARE FOOT T.S. TUBE STEEL DIA. or DIAMETER H.C. HOLLOW CORE PSI POUNDS PER SQUARE INCH TYP. TYPICAL DIAG. DIAGONAL H/C HANDICAPPED PVC POLYVINYLCLORIDE V.B. VAPOR BARRIER DIM. DIMENSION HGT. HEIGHT PWR. POWER V.LF. VERIFY IN FIELD DL DEAD LOAD HOR. HORIZONTAL QTY. QUANTITY WP WEATHER PROOF ON. DOWN HW HOT WATER R RADIUS W/ WITH DR DOOR IMPG. IMPREGNATED R.0. ROUGH OPENING ie WITHOUT i YARD Scale: NTS REMODEL FOR MARGARET BIMEL SHEET SCHEDULE PROJECT DATA SHEET 1 TITLE SHEET SHEET 2. SITE PLAN OWNER MARGARET BIMEL SHEET 3 FLOOR PLANS 921 TAYLOR ST. PORT TOWNSEND : SHEET 4 ELEVATIONS PROPERTY 921 TAYLOR ST. PORT TOWNSEND ADDRESS | WASHINGTON 98368 PROPERTY PLUMMERS ADDITION BLK 13 LOT 4 N38'3 APN 988801303 SCOPE OF REMOVE FIRE DAMAGED BUILDING WORK COMPONENTS. REBUILD AND UPDATE TO MODERN ENERGY & SAFETY CODES ENCLOSE FRONT PORCH ZONING: R-2 SPEC.'S REA mest IMPERVIOUS 516 7 OF Ih ‘ 29 195% % OF IM PERVIOUS 7 J.12 = a NOTICE: Plans are approved excepting FOOTPRINT 87€é any errors or omissions. All work must FOE POST Be? FEOF pass inspection in conformance with Z/. all applicable codes and regulations. FILE COPY « UWE SEND DRAWN BY DAVID DICKSON (831) 251-2518 APN: 988801303 Da v o Br e DE S I G N RE M O D E L 92 1 TA Y L O R REV. DATE DEC - 08 - 10 (831) 251.2518 DAVID.N.DICKSON@GMAIL.COM DAVID.N.DICKSON@GMAIL.COM —aerwsec or mins sesace 1 sheet] FLE COPY | SITE PLAN & Scale: 1/4°=1' PROPERTY LINE WN se a Se ELECTRICAL METER SIDEWALK st. | | , | | | We. i f ee i len: adie inne ae — —S ——— ri he eee a SIDEWALK \ O \ | 2 Eres ees _ | _ SN | | | ENTRY ——= | | — FRONT PORCH a EXISTING HOUSE 921 TAYLOR 4 Oy = = —_ _ —— — —f 6S I fe : v t i ¢ | y 4 a | a — i) a — 7 ——— — | | \ C props S ; ‘a | | ron N he f - ec wd i GRASSY BURM | x yy CE N T E R L I N E TA Y L O R ST R E E T N (FIRE DAMAGE REPAIR & REMODEL FOR MARGARET BIMEL APN: 988801303 Da o D IC K S O N DE S I G N RE M O D E L 92 1 TA Y L O R REV. DATE DEC - 08 - 10 SCALE as noted. 1/4"=1' DRAWN by DAVID DICKSON (831) 251.2518 DAVID.N.DICKSON@GMAIL.COM 2 sheet FILE COPY _ FIREPLACE APN: a »9 6) | i — 6" 22 10'-11 W"=4 L. 7 2-0 5-0 2% [te = yp— se wrth ¢ t as + I 17 SS : _ L—rk “ i A Vy i Ou cat, qa SS \ 2 3°3"y4'6" rae, 33 x46 R310.1.1 Egress, - Minimum net clear - ; 2 EGRESS opening of 5.7 sq. ft. i ZA. Exception - Grade floor openings, Minimum = X a | net clear opening of 5 sq. ft. O ; Minimum opening height, shall be 24" Y — 34" y4'4” N ; 3'4"ba'4” Minimum opening width shall be 20" x< : a ees 2 ee et OO —_—Z! ‘0 LAUNDRY ROOM % BED 2 ‘i il BED 2 > ~ 1 -U« van : Section 508 - Uniform Plumbing Code. C ARPET - Water heaters shall be strapped at points within F the upper and lower 1/3 points of its vertical W. (N) 18X18X6 PIER ~ i) tb dimension. At the lower point, a distance of not \ /N\N Hs ©) less than 4" shall be maintained above the r N \ th q controls with the strapping. q | NS ~\ I ¥ i tt QO via ‘ rt = —o = F . BATHROOM L ‘ 100 oFM exiausr FAN | | \7/F 5, ! | i ; i i = LIGHT AND HEATER i , a = A’ ( a o——. . (N)4’0"x4'0' . = {\ EGRESS =| | $ , = AB I hg" i BED | ! 41 Oo } U J f@p@ f..-} 1M 7 ~ A ~ AN a o 7 8X8 FLOOR BEAM ee: eat al ™ uy ns i 2 X 6” FLOOR JOISTS TYP. vale kK ; —. 7 : © ; L190 CRM NIN, 1 (N) 18X18X6 PIER if \ ” D/W ra + D/W eae CARPET KITCHEN ; i 4 KITCHEN Sec. R314, 2009 IRC - Smoke Alarms oF nin. ai 3104’ ” sill To be located in each sleeping room, La 3'10"x4'6 \ J] XA ; : : : ; 7 outside each sleeping area in the immediate \ . ® vicinity of the bedrooms, on each story of the dwelling. Interconnected 110 volt with oo oes | eWeek ce aye - oO battery backup. 7 Y 3 , : — “REPLACE (E) 8X8 ROOF JOIST ~ BEAM W/ (N) 6X10 GLULAM 7 LIVING R¢ i 7 | 2. GLAZING U-FROTOR 0.25 + fe —TYP. ROOF OVERHANG FRAMING ol Of PETTER -TrYPicAl— a a. oo 6s yaa” — 2X12 ROOF JOISTS TAP ’ TO SLO AA : 6'3"x4'4" INI CG S()C)\K\A re 6'°3°«4'4 . | en Oe ROOF JOISTS TAPERED TO SLOPE 16° OC. TYP . | VII le ROO | a , L CARPET | © : oe ‘NX : VIN YL »* es 5 6'3"x4"4" (nN 4 I | t i | EN | a | CO ey =e < z= co oo >< a ov m w L ad = _ a A ay KS y —OX6-8 STORM DOOR OC | (NM OM R ( } NCLOSED UNHEATED SM / 3 KH aS g Is VA \ res --~, ed REMOVE EXISTING CEMENT PORCH TEMP. [GLASS ant y 8'-0" 2'-0" EXISTING FLOOR PLAN PROPOSED ELECTRICAL PLAN Scale: 1/4"=1' Scale: 1/4"=1' ( )- PROPOSED FLOOR PLAN Scale: 1/4"=1' Seals and Weather-stripping: (Air Seal) Openings shall be sealed, caulked, gasketed, or weather-stripped to limit air leakage. Exterior joints around windows and door frames, openings at penetrations through walls, floors, roofs and -— RE M O D E L 92 1 TA Y L O R other openings in the building envelope. A LEGEND (E) 2X12 TAPERED TO 2X8 ROOF JOISTS \ , DUPLEX OUTLET 1 WALL MOUNTED LIGHT FIXTURE (N) R-38 CLOSED CELL INSUL. Nees 2X12 ROOF JOISTS Gi Ghi= GROUND FAULT INTERRUPTER (N) 1/2” GYP. BRD. a eee 2X6 RAFTERS N) 1X8 FASCIA ©} _— DUPLEX OUTLET 1/2 SWITCHED -Q- CEILING MOUNTED LIGHT FIXTURE (N) COMP. ROOFING (N) 2X6 RAFTERS ia FOUR PLEX OUTLET nn a (E) SIDING TO REMAIN (N) 1/2” GYP.BD. | = 220 VOLT OUTLET O RECESSED LIGHT FIXTURE et (N)_ R=21_ FG. INSUL. a) 2X4 WALL (N) 2X4 WALL mi FI SWITCH EXHAUST r] (N) 2X2 FURRING STRIPS (N) FOOTING (N) FOOTING =" ae 2 Lei — _ te 2X4 WALL ca BAR | #5 BAR IN MIDDLE THIRD i 6. EXH. FAN ee (N)1/4” LAUN UNDERLAYMENT eo) PORCH SLAB o (N) PORCH SLAB [| TELEPHONE RECEPTACLE (E) HARD, wooD Cin, TT | ++{ CABLE TV 1S) EXH. FAN & LIGHT COMBINATION (N) R=30 F.G INSUL, t REV. DATE .$-—2” x 6” FLOOR JOISTS TYP. ae \ ‘p— ® GAS OUTLET t—— UNDER CABTT. FLUOR. LT. ———] | oe = BEAM | rar ce DEC - 31 - 10 - “=20 AZ o PIER TYF : Sa -= - THERMOSTAT [——1__ CLG. MTD. FLUOR. LT. FIXT. to as + HOSE BIBB | PORCH WALL SECTION PORCH WALL SECTION H.B PENDANT MOUNTED LIGHT FIXTURE TYPICAL WALL SECTION 2 a 1 oe S 115 VOLT SMOKE DETECTOR Scale: 1/4"=1' INTERCONNECTED W/ CEILING FAN BATTERY BACKUP F = FLUORESCENT D = DIRECTIONAL SPOT MS = MOTION SENSOR VteeibaeD (FIRE DAMAGE REPAIR & REMODEL FOR MARGARET BIMEL NOTE: OUTLETS INSTALLED AS REQD. SCALE as noted. DRAWN by DAVID DICKSON sh e et (831) 251.2518 DAVID.N.DICKSON@GMAIL.COM FILE COPY - APN: 988801303 | | Br & ee DE S I G N | & NORTH ELEVATION — C) EAST ELEVATION — S >= . - Ss L = i TI ‘ea a OF “J € SOUTH ELEVATION we ——o | Cc) WEST ELEVATION — ra ELEVATIONS =. Scale: 1/4"=1' 7 REV. DATE DEC - 31 - 10 (FIRE DAMAGE REPAIR & REMODEL FOR MARGARET BIMEL SCALE as noted. DRAWN by DAVID DICKSON S h E et (831) 251.2518 DAVID.N.DICKSON@GMAIL.COM FILE COPY