Loading...
HomeMy WebLinkAboutBLD10-108CONSTRUCTION PROGRESS RECORD CITY OF PORT TOWNSEND Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 POST THIS CARD IN A SAFE, CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF BY THE APPROPRIATE AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE. PARCEL NO. 984900302 PERMIT NO. BLD10-108 ISSUED DATE 07/01/2010 EXPIRATION DATE 12/28/2010 ADDRESS 701 ROSE STREET CONSTRUCTION TYPE V-B = OCCUPANT LOAD OWNER SHIRLEY BRENT PROJECT DESCRIPTION 560 sq.ft. ADU Garage/Storage on 1st floor with bathroom CONTRACTOR OWNER BUILDER LENDER INSPECTION INSP JATE COMMENT INSPECTION INSP JATE COMMENT TESC -FENCE/ENTRANC FINAL BLDG./C OF O | | | | Ho Zlo| UFER IN SETBACKS SURVEY PIN‘ FOOTING FOUNDATION DRAIN FOUNDATION WALL Yolo PLUMBING HYDR. WHA TR-ld RiG@»pp SuAB tA 8.2570 SLAB ‘. ae: Nw MECHANICAL SHEAR WALL Pe ey INSULATION / GWB FINAL PUBLIC WORK PLANNING FINAL NOTICE TO TITLE TO REQUEST AN INSPECTION CALL (360) 385-2294. INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 3:00 PM FOR NEXT DAY INSPECTION. Meg Way From: — Brent Shirley [brent@brentshirley.com] Sent: | Thursday, November 03, 2011 5:23 PM To: Meg Way Subject: Re: BLD10-108 Meg, I would like to request an extension of BLD10-108 for the maximum period allowed. Under the current economic environment I am not in a position to continue at the present time. Brent Shirley On Nov 2, 2011, at 4:25 PM, Meg Way wrote: Hi Brent, This is just a reminder that BLD10-108 for the ADU expires on 11-8-2011. To keep the file from expiring on that date, we would need a letter from you requesting an extension, if you are planning on proceeding with the project and want to avoid any additional fees/charges. Thanks and have a safe trip! Meg Meg Way Administrative Assistant Development Services Department City of Port Townsend 250 Madison Street, Suite 3 Port Townsend, WA 98368 Phone: 360.379.5082 Fax: 360.344.4619 Brent Shirley The Carwash, Inc. 515 Howard Street PO Box 748 Port Townsend, WA 98368 360-774-0992 11/4/2011 CITY OF PORT TOWNSEND DSD 130 doy evlension wes rol Exp. So be Meg Way From: Meg Way Sent: Wednesday, November 02, 2011 4:25 PM To: ‘brent@brentshirley.com' Subject: BLD10-108 Hi Brent, This is just a reminder that BLD10-108 for the ADU expires on 11-8-2011. To keep the file from expiring on that date, we would need a letter from you requesting an extension, if you are planning on proceeding with the project and want to avoid any additional fees/charges. Thanks and have a safe trip! Meg Meg Way Administrative Assistant Development Services Department City of Port Townsend 250 Madison Street, Suite 3 Port Townsend, WA 98368 Phone: 360.379.5082 Fax: 360.344.4619 11/2/2011 EU Oe IT SHIR 06/01/2010 03:92 Wa eeaiier’ soi tice os donna Eldridge, Auditor er AR AN etl A GR AH City of Port Townsend Development Services Department 250 Madison Street Suite 3 Port Townsend, WA 98368 NOTICE TO TITLE Grantor/Owner: Brent Shirley Grantee: Reference: City of Port Townsend, a Washington municipal corporation City Building Permit Number BLD10-108 Legal description: | Grantor/Owner owns the following described real property: Pettygrove’s First Addition, Block 3, Lot 2 Assessors Property Tax Parcel Number: 984-900-302 NOTICE IS HEREBY GIVEN to the Grantor/Owner of the above-referenced real property, to potential purchasers and future owners, to agents or representatives, and to any other concerned person or entity: 1) 2) Page 1 of 2 A detached Accessory Dwelling Unit (ADU) is proposed through building permit BLD10-108. The ADU is given the address of 701 Rose Street. It will share the public sewer and water connection with the single-family residence addressed as 803 G Street. The Port Townsend Municipal Code (PTMC) requires that the property owners reside on the subject property, in either the principal residence or ADU in order to rent or lease the other unit. A one-year hardship waiver may be granted by the City in accordance with PTMC 17.16.020.C.2. Additionally, neither the principal nor accessory unit shall be used as a transient accommodation (PTMC 17.16.020.C.3). A transient accommodation is defined as a use no more than 29 consecutive calendar days (PTMC 17.08.060). Shirley ADU Notice to Title 3) This notice may be removed or modified only with approval by the City. CITY OF PORT TOWNSEND By: WU 26 My |O / Zp Die Development Services/Planning Director Development Services Department OU cifia Brent Shirley Date Property Owner STATE OF WASHINGTON ) )ss. COUNTY OF JEFFERSON _) I certify that I know or have satisfactory evidence that Brent Shirley is the person who appeared before me, and who acknowledged that he signed the same as his free and voluntary act for the uses and purposes mentioned in the instrument. Given under my hand and official seal this \ day of June , 2010. s SS My Lao ho, A. WSC 2 % f we “@ Z (Print on Nie, A. \AJON trio tae FF Ory PUBLIC in and for the State of YOU 44 oa EF Washingio ; =z 1-4 % US! Chie 5. y este smonanseOe Residing at: “ny 4 mS sivas Fiy4 OwNend, wWFr My appointment expires 1\2-\SG-\5 [Notary stamp inside 1" margin] Page 2 of 2 City of Port Townsend Development Services Department BUILDING ADDRESS APPLICATION Name of Property Owner: B re at Sh Was l CLL Mailing Address: __ Po Bo x 7 ¥S Port Town Sened, WA ASP Telephone: _M1lze Vhar'c toy (360) S 31-2246 Property is located in: Addition: Pethy Gmep___ Block(s):_3 Lot(s): _2. Faces/Access is from: Race Sp. (new Driveway thagh 1b —5° 7) Parcel Number F FY -— G00— 302. Directions to the Property (draw vicinity map on back) Adv DRive loaY 5-N\9-| If this is a new ADU, has a building permit been applied for? “Yes __No Date: e Notes: ADDRESS NUMBER ASSIGNED: 10 | Kose st. Date of Approval: 2¢4//lag 20/0 haut 4S Fv For Department Use Only: Application Fee Received ($3.00): Date: Copy to: 0 Finance O Fire Dept 0 Post Office 0 Sheriff 0 Police O GIS 0 Public Works ODSD database — ‘f 0 Assessor’s Office P\DSD\Forms\Building Forms\Application-Address Number.doc ; 2/5/09 7/1/11 _| . , a Wid Yu fo 24-1e & TO REV est AY )SO CAY EXTEN Dion For MY ADU _L CevtTino= TS Woewre on) “THIS FReOSEr Pece MEK. ADS 1 CAN Core enrey cb AAVe&e AP SbeaKeiaArw CONTA CVOR— HooKin& IP prow CITY OF PORT TOWNSEND PERMIT ACTIVITY LOG PERMIT # O — LOY DATE RECEIVED _ 5 ~ (47/9 SCOPE OF WORK: MA | [ob ter Aes Pom Kose SF DO veiw ax OP ro DATE ACTION INITIALS G-(q-(0 | ENTERED INTO CHET NWA A i] S—(G- (OQ | CHECKED FOR COMPLETENESS MIW 5-24 -lo | Hddress= ? [N eed procte Lorne ADU Noe | Sua 4s title.) f6 Laois To] Kote reef arrtooed seule | SAO Plan veuew? omels S) FS S/2¢fe Nabe to THe signed by RS. Emotes Bremt Sh. to Con~plete by ' Signing ~ fe Cacdinp . Si CAm done CAmip- 09 — Se nofes enclosed: Zoning: A~r Setbacks OK? Lot Size: Building Size: Lot Coverage: FAR OK? Height OK? Parking OK? Critical Area? Demo? Historic Rev? Notice to Title? Lots of Record? EN T ! ng Fe r c e wv GF PU s T in g Fe n c e LI N G D S D 6- 0 " ' | — rr ; e _ J 0 ° 0 " " > a : EX I S T V6 , DR I V E W A Y | Gs T AD Y CA R H GE | + PA R K I M G 25 - 0 | SI T E | \ « i | | _ , 35 - 0 " I< os Vv | | | EX I S T /U 6 K we | HO U S e 4- 0 " a) €— 1 0 - 0 " - 5 , —] 6 - 0 " ye 60 40 7 0 " 2 3 - 0 " — _ > > | | | i 7] j= 4 _ | BN ‘| } 2. 9 4 0 " EN I S T I“ FE e r n t e Li w e Vv ( L ae Q E E E T T E D : nN oo MA Y - - 4 - 9 . = - 2 0 1 0 - — f L = L } RO S E ST . Ci t y OF PO R T TO W N S E N D BUILDING PERMIT City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Project Information Permit # BLD10-108 Permit Type Residential - Accessory Dwelling Unit Project Name NEW ADU Site Address 701 ROSE STREET Parcel # 984900302 Project Description 560 sq.ft. ADU Garage/Storage on Ist floor with bathroom and kitchen on 2nd floor. Names Associated with this Project License Type Name Contact Phone # Type License # Exp Date Applicant Shirley Brent Owner Shirley Brent Representative Shirley Mike Contractor Owner Builder QO- STATE exempt 12/31/2010 Fee Information Project Details Project Valuation $62,504.00 Dwellings — Type V Wood Frame 520 SQFT Bnengy CodsFes:-New: Single 100.00 Private Garages — Wood Frame 520 SQFT Panity Un Units: Heat Type: HYDRONIC PLAN REVIEW DEPOSIT 150 150.00 : . . ; ; . Bedrooms: 1 Construction Type: V - B Mechanical Permit Fee per Dwelling 150.00 Dothoome 1 Occupancy Type: R-3 Unit - New Residential Plumbing Permit Fee per Dwelling 150.00 Unit - New Residential Building Permit Fee 734.75 State Building Code Council Fee 4.50 Technology Fee for Building Permit 14.70 Record Retention Fee for Building 10.00 Permit Total Fees $ 1,313.95 *%* SEE ATTACHED CONDITIONS *** Call 385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify that I am the owner of the property or authorized agent of the owner. Print Name BLES) >, SHIRLE Date Issued: 07/01/2010 Issued By: MWAY Signature 7 \ D Date 1] ) }1O Date Expires: 12/28/2010 a BUILDING PERMIT City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Project Information Permit # BLD10-108 Permit Type Residential - Accessory Dwelling Unit Project Name NEW ADU Parcel # 984900302 Site Address 701 ROSE STREET Project Description 560 sq.ft. ADU Garage/Storage on Ist floor with bathroom and kitchen on 2nd floor. Conditions 10. Property corner survey pins must be located at time of footing inspection to verify setbacks. Call 385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify that I am the owner of the property or authorized agent of the owner. Date Issued: 07/01/2010 Print Name _ = - Issued By: MWAY Date Expires: 12/28/2010 Signature Date Development Services "CHY OF PORT TOWNSEND” DSD 250 Madison Street, ‘Suit te 3 “www cltyofot us” Residential Building Permit Application Project Address: Legal Description (or pes $63 Far I ol R OoSe Gh Addition: Fe FEU Yeoleo Zoning: Block: Parcelt# 99: 960 30Z. Lot (s): = Project Description: jt Floo2 ; 560SE ADU. C-ARAgE / S702 Age ON Sates) Mater. wth Baznecom & iL rteher 0 Sec Applications by mail must include a check for initial plan review fee of $150 for projects valued over $15,000. See Page 2 for details on plan submittal requirements. Property Owner/Applicant: Name: BZen1 S&S. SH LENS Address: FO SOX 778 City/StZip: FEST TOW) SEND. WA TEKS, Phone: Email: BeemMie@ BeenTgnietay ~\ Building Information (square feet): 1* floor ——> Garage: 560 s¢ 2™ floor 5 60s¢ Carport: 3” floor Other: Basement Contact/Representative: Name: Mike SH/RLEY Phone: 340° § F/- 22YE Email: fiverrat829@ MSN-Com Finished: 460 Unfinished: Decks / Porches Covered: Uncovered Heat Type:_ 2wAp/4n07 Electric Heat Pump_\f__ Other Contractor: Name: Address: City/St/Zip: Phone: ‘sx Same as Owner Email: State License #: Exp: City Business License #: Total: #Bedrooms / #Bathrooms__| Size of lot S000 Square feet Total Lot Coverage (Building Footprint):* Square feet: IG % Bs, LE Impervious Surface:* Square feet: e~ TY *Total existing & proposed Lender Information: Lender information must be provided for projects over $5,000 in valuation per RCW 19.27.095. Name: Figsr PepecA U Project Valuation: $ 0) 000 What year was the structure built? | UTE If work includes demolition, see Page 2. Any known wetlands on the property? Y ®) Any steep slopes (>15%)? Y(N) | hereby certify that the information provided is correct, that | am either the owner or authorized to act on behalf of the owner and that all activities associated with this _ will be in accordance with State Laws and the Port Townsend Municipal Code. 5 > HIELE Print = Signature:_ DO 3 : Page 1 of 2 - 1/4/2010 Date: 5/3 hi O -OVER- RESIDENTIAL BUILDING PERMIT APPLICATION CHECKLIST This‘checklist is for new dwellings, additions, remodels, and garages. sidential permit application. ashington State Energy & Ventilation Code forms Oo aa sets of plans with North arrow and scaled, no smaller than %” = 1 foot: A site plan showing: 1. Legal description and parcel number (or tax number), 2. Property lines and dimensions 3. Setbacks from all sides of the proposed structure to the property lines in accordance with a pinned boundary line survey On-site parking and driveway with dimensions If creating new impervious surfaces, indicate measures utilized to retain stormwater on-site Street names and any easements or vacations 4 5 6. 7. Location and diameter of existing ees —- ip TEES jal bvilcop: wuA 8. Utility lines enlvelo pe 9. If applicable, existing or proposed septic system location 10. Delineated critical areas boundaries and buffers 0 Foundation plan: 1. Footings and foundation walls 2. Post and beam sizes and spans 3. Floor joist size and layout 4. Holdowns 5. Foundation venting O Floor plan: 1. Room use and dimensions 2. Braced wall panel locations VPEray > say hh 3. Smoke detector locations ' 4. Attic access 5 6 7 aa > C' rs “we * a. 3 * Plumbing and mechanical fixtures oh POSR ee ASN Occupancy separation between dwelling ants Sts (if applicable) ' Window, skylight, and door locations, including escape windows and safety glazing O Wall section: Footing size, reinforcement, depth below grade Foundation wall, height, width, reinforcement, anchor bolts, and washers Floor joist size and spacing Wall stud size and spacing Header size and spans Wall sheathing, weather resistant barrier, and siding material Sheet rock and insulation Rafters, ceiling joists, trusses, with blocking and positive connections Ceiling height 10. Roof sheathing, roofing material, roof pitch, attic ventilation 0 Exterior elevations (all four) with existing slope of the land in relation to all proposed structures O If architecturally designed, one set of plans must have an original signature 0 If engineered, one set of plans must have one original signature Ufor new dwelling construction, Street & Utility or Minor Improvement application CO N O A L W N > If you are proposing partial or full demolition of a structure that is at least 50 years old, per Ordinance 2969 Historic Preservation Committee (HPC) review is required. If within the National Historic Landmark district: $58.00 for full committee review. If outside the National Historic Landmark district and not on the Historic Register: no fee for HPC Administrative review. Complete HPC Form. Partial demolition includes exterior demolition for additions and remodels. Page 2 of 2 - 1/4/2010 -OVER- OLOZ/6I/S ZO€006P86=ON *AOUVdédse THerepjeosed /jaored/siossa-"w/sn"em Uossayjal oo MMM //:dyY aa |) MAY 19 2010 CITY OF PORT TOWNSEND DSD 7 JOT O8eg s[lejoq [seg 2006 Washington State Energy Code - Prescriptive TABLE 6-1 PRESCRIPTIVE REQUIREMENTS” FOR GROUP R OCCUPANCY CLIMATE ZONE 1 Glazing Glazing U-Factor Door ® ie Wall"? wal walt Slab® Option | Area’: oor” | Ceiling? | Vaulted | Above | © Floor® | on % of Floor | Vertical | Overhead"' | U-Factor Ceiling’ | Grade | Below | Below Grade Grade | Grade 1. 10% 0.32 0.58 0.20 R-38 R-30 R15 R-15 R-10 R-30 R-10 I.* 15% 0.35 0.58 0.20 R-38 R-30 R-21 | R21 | R10 | R30 | R10 i. 25% 0.40 0.58 0.20 R-38 / R-30/ R-21/ R-15 R-10 R-30/ R-10 Group R-I U=0.031 | U=0.034 | U=0.057 U=0.029 and R-2 Occupancies Only IV. Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 Group R-3 and R-4 Occupancies Only V. Unlimited 0.35 0.58 0.20 R-38 / R-30/ R-21/ R-15 R-10 R-30/ R-10 Group R-I U=0.031 | U=0.034 | U=0.057 U=0.029 and R-2 Occupancies Only * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. ‘Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1-inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the “ceiling” requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross in glazing area limitations. | } {fe \ 11. Overhead glazing shall have U-factors determined in accordance ion 502.1.5. 12. Log and solid timber walls with a minimum average thickness 0 re exempt from this insulatic uirement. MAY 19 2010 |LYY | | | Effective July 1, 2007 CITY OF PORT TOWNSENL _ 2006 Edition City of Port Townsend Development Services Department Waterman & Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 (360) 379-3208 Fax: (360) 385-7675 2006 Washington State Ventilation & Indoor Air Quality Code SOURCE SPECIFIC VENTILATION (302.2.1) Required in each kitchen, bathroom, water closet, laundry room, indoor swimming pool, space, and other rooms where excess water vapor or cooking odor is produced. See Table 3.1 for capacity requirements. SOURCE SPECIFIC VENTILATION DUCTS (302.2.3) Shall terminate outside the building. Exhaust ducts in systems designed to operate ; intermittently shall be equipped with back-draft dampers. All exhaust ducts in unconditioned spaces shall be insulated to a minimum of R-4. Terminal elements shall have at least the equivalent free area of the duct work. Terminal elements for exhaust fan systems shall be screened or otherwise protected from entry by leaves or other material. WHOLE HOUSE VENTILATION SYSTEM REQUIREMENTS (302.3) Each dwelling unit shall be equipped with a whole house ventilation system capable of providing the volume of air specified in Table 3-2 under normal operating conditions. Controls (302.3.2) shall be readily accessible and capable of operating the system without energizing other energy-consuming appliances. Intermittently operated systems shall have the capability for continuous operation, and have a manual and automatic control suchas an automatic control timer. At the final inspection the timer shall be set to operate the whole house fan for at least 8 hours per day. Fan Noise (302.3.3) for whole house fans located 4 feet or less from the interior grille shall have a sone rating of 1.5 or less measured at 0.10 inches water gauge. Remotely mounted fns shall be isolated from the structural elements of the building and attached duct work using insulated flexible duct or other approved material. Exception: systems integrated with forced-air heating systems or heat-recovery ventilation systems are exempt from sone ratings. Ducts (302.3.4) shall terminate outside the building. Exhaust ducts in intermittently operating systems shall be equipped with back-draft dampers. All exhaust ducts in unconditioned spaces and supply ducts in conditioned space shall be insulated to a minimum of R-4. OUTDOOR AIR (302.3.5) Outdoor Air Inlets (302.3.5.2) shall be screened or otherwise protected from entry by leaves or other material. They shall be located so as not to take air from the following areas: a. Closer than 10 feet from an appliance vent outlet, unless such vent outlet is 3 feet above the outdoor air inlet. = Where it will pick up objectionable odors, fumes, or flammable vab rs. A hazardous or unsanitary location. A room or space having any fuel-burning appliances therein. | | Closer than 10 feet from a vent opening of a plumbing drainage system unless the |Lo=/ | vent opening is at least 3 feet above the air inlet. — - f. Attic, crawl spaces, or garages. : ea o Ss P:\DSD\Forms\Building Forms\Information-Ventilation.doc 04/16/2009 Page 1 of 1 City of Port Townsend TABLE 17.16.030 Residential Zoning Districts - Bulk, Dimensional and Density Requirements DISTRICT R-I CRI aN R-II R-IV MAXIMUM HOUSING 4 dwelling units (Multiple 8 dwelting-units(Multiple—T —_ 16 units per 40,000 sf 24 units per 40,000 sf DENSITY (units per dwelling units on a single lot | dwelling units on a single lot of lot area of lot area 40,000 square foot area) must be contained within a must be contained within a single structure, except: a single structure, except: a permitted accessory dwelling | permitted accessory dwelling unit (ADU) may be unit (ADU) may be established in a separate established in a separate building if allowed by building if allowed by 17.16.020 PTMC) 17.16.020 PTMC) (10,000 sf of lot area per unit) | (5,000 sf of lot area per unit) MINIMUM AVERAGE 10 units where a parcel 15 units HOUSING DENSITY and/or contiguous parcels (units per 40,000 square under single ownership foot area) are 12,000 square-feet in size or greater MAXIMUM NUMBER 4 (Note: limited structures 4 (Note: limited structures No limit No limit OF DWELLING UNITS with more than 4 dwellings with more than 4 dwellings IN ANY ONE per structure may be permitted per structure may be STRUCTURE through the PUD process, see permitted through the PUD Chapter 17.32 PTMC.) process, see Chapter 17.32 PTMC.) MINIMUM LOT SIZE 10,000 sf = single-family 5,000 sf = single-family 3,000 sq ft = single-family detached detached detached; 5,000 sf = single-family attached (duplex); 7,500 sf = single-family attached (triplex); and 10,000 sf = single-family attached (fourplex) and multi- family! MINIMUM LOT 50’ 50’ 30’ except: 100’= WIDTH multifamily MINIMUM FRONT 20’ except: 10’ except 20 feet for 20’ except: 20’ except; YARD SETBACKS 50’= barns and agricultural garages with vehicle access 10’ w/side or rear 10° w/side or rear buildings facing a street right-of-way parking/garages; garages parking; no setback for and 50’=barns and with vehicle access facing multifamily structures agricultural buildings a street right-of-way must located within 200 feet be setback 20’; no setback | of an abutting mixed use for multifamily structures zoning district located within 200 feet of an abutting mixed use zoning district MINIMUM REAR 20’ except: 10’ except: 10’ except: 15” except: YARD SETBACKS 50’ = barns and agricultural 100’ = barns and agricultural | no setback for multifamily | 20’ if directly abutting buildings, and 100’ if abutting buildings structures located within | an R-I or R-II district; no a R-II, R-II, or 200 feet of an abutting setback for multifamily R-IV zoning district mixed use zoning district | structures located within 200 feet of an abutting mixed use zoning district See Back of This Page For More "In order to achieve the minimum density, subdivision of parcels 12,000 square feet or greater shall not allow individual lots larger than 4,000 square-feet unless said lots are reserved for multi-family dwellings. P:\DSD\Forms\Building Forms\Information-Table 17.16.030 Res Zoning Districts.doc Page 1 of 2 05/15/09 City of Port Townsend TABLE 17.16.030 Residential Zoning Districts - Bulk, Dimensional and Density Requirements DISTRICT R-I R-II R-II R-IV MINIMUM SIDE 5° except: 5’ except: 5? except: 15’ except: YARD SETBACKS 10’= abutting a street r-o-w; 10’= abutting a street r-o-w; 10’= along a street r-o-w; 20’ if directly abutting 20 feet for garages with 20 feet for garages with 20 feet for garages with an R-1 or vehicle access facing a street | vehicle access facing a street vehicle access facing a R-II district; no setback right-of-way and 50’ barns right-of-way and 100’= street right-of-way and no for multifamily and agricultural buildings and barns and agricultural setback for multifamily structures located within 100’ if abutting a R-II, R-III, buildings structures located within 200 feet of an abutting or R-IV zoning district 200 feet of an abutting mixed use zoning district mixed use zoning district MAXIMUM 30’ 30° 35’ 35° BUILDING HEIGHT MAXIMUM LOT 25% 35% except 40% where an 45% 50% COVERAGE ADU is included on the lot MAXIMUM FENCE Front=4’; Side=8’; Side Front=4’; Side=8’; Side Front=4’; Side=8’; Side Front=4’;Side=8’; HEIGHT* abutting a public right-of-way abutting a public right-of- abutting a public right-of- Side abutting a public =4’; rear=8’ way = 4’; rear=8’ way =4’; rear=8’ right-of-way =4’; rear=8’ e NOTE: Maximum fence heights apply within any required front, side, or rear setback area or along the edge of any required yard, refer to Chapter 17.68 PTMC, Fences, Walls, Arbors, and Hedges for specific requirements. (Ord. 2967 9 4.2.2008; Ord. 2939 99 1,2, 2007; Ord. 2913 a 2, 2005; Ord. 2925 9 4, 2003; Ord. 2782 3 4, 2001; Ord. 2716 a 4.3, 1999; Ord. 2700 a 11, 1999; Ord. 2571 3 2, 1997). P:\DSD\Forms\Building Forms\Information-Table 17.16.030 Res Zoning Districts.doc Page 2 of 2: 05/15/09 Wa t e r Wa s t e Wa t e r St o r m Wa t e r 1 in c h = 22 . 8 2 1 8 2 1 fe e t LIM alial Land Use Checklist Parcel Number: 154 f00~3 02. Legal Description: _Pethyg aver, 1 KS Oke 7X19 Location. _§O3 G Sh Zoning: Rie La 5 Recorded Plat Shows Lot Size as: 2 XC 00 ) Streets: GO a Need a Ure} to See Assessor Shows: ArcReader Shows: Critical Area? Not oppo. Other Permits? Part of a Plat, BSP or PUD? (Any Conditions? Tree Plan?) . Bult 0 (972 - 960544 lO" toa 20° Forope, S 'S ‘de, 253 garage. . /2/ 3 > Swm y, _y Building meets lot coverage? _: _/V/] aX wi i 6c Y 00 W i ADU, QYY Loh — up to 2, 0 Sq Ft. o Building meets height restrictions? (If close, ask for elevations/cortours showing existing and final grade; Site Visit? Building meets setbacks? __‘ in some cases need to establish reference datum.) a) 4 oe | ‘ 7 - tice,to Title needed?_ /rhape it hovke vey t moof Lit lence fo Lotbacg. ) AD U/ Non Cty [Tee 4 a ° Restrictive Covenant needed? No ~ | eXha partusy J pe Ce — Fo, J by site. 5 Lots of Record needed? No. [ov Apu e site ’ Comments: Cuvrtmt 4 CUS th ragh OF Nev accea fom Rose St? (lam bane a Lind davew ay wl MIP. Canphat top) Seowert water hon 6. St- bo fred / / ; Of 7 ~ ( yn distance bed-eon build mo WSs than Plat Shooto G rerpe Side. ( Ms de feu no tte louse . Parcel Details Page | of 2 3 ae a > Departments + Search Parcel Number: Parcel Number: 984900302 ~~” Printer Friendly Owner Mailing Address: BRENT SHIRLEY PO BOX 748 PORT TOWNSEND WA983680748 Site Address: 803 GST PORT TOWNSEND 98368 Section: 2 School District: Port Townsend (50). Qtr Section: SW1/4 Fire Dist: Port Townsend (8) Township: 30N Tax Status: Taxable Range: 1W Tax Code: 100 Planning area: Port Townsend (1) Sub Division: PETTYGROVE'S 1ST ADDITION Assessor's Land Use Code: 1100 - HOUSES (single units, non-farm) Property Description: PETTYGROVE'S 1ST ADDITION | BLK 3LOT2] | | IN) ECE n) i Wt | Click on photo for larger image. r | | | may 19 2010 JL No 2nd j EI Photo L _ Available CITY OF PORT TOWNSEND No Permit Data Assessor Bldg Data [Tax, A/V, Sales Info Map Parcel Plats & Surveys Available % Jefferson County HOME | COUNTY INFO | DEPARTMENTS | SEARCH Best viewed with Microsoft Internet Explorer 6.0 or later € Windows - Mac _ http://www.co.jefferson.wa.us/assessors/parcel/parceldetail.asp?PARCEL NO=984900302 5/19/2010 Assessor Detail Building #1 Jetferson County ~ Home » County info “Departments » Search Assessor Detail Building #1 Parcel Number: 984900302 Building Number Year Built Year Remodeled 1 1972 0 Building Exterior Building Area Building Interior Building Type: HOUSE Building Style: 1 STY Foundation: CONCRETE PERIM. Exterior: PLY/T1-11 Roof Cover: COMPOSITON 1st Floor Area: 960 2nd Floor Area: 0 3rd Floor Area: 0 Loft Area: 0 Attic Area: 0 Total Area: 960 Basement Area: 0 Int. Walls (Cabin): Heat: ELECTRIC BB/WALL ISIN. 1 STY. Floor Cover (1): VINYL Floor Cover (2): CARPET Building Rooms Mobile Home Garage Bedrooms: 2 Full Baths: 1 Half Baths: 0 Make: Model: Length: Width: Year Built: Skirting: Area: 0 Type: Attached Area: 253 Exterior: Ply/T1-11 Roof: Compositon Carport Square Footage: 0 ist Addition 2nd Addition Type: Area: O Year Built: 0 Exterior: Roof: Type: Area: O Year Built: 0 Exterior: Roof: To view another building associated with this parcel. Select building : 1 2 3 Jefferson County Best viewed with Microsoft Internet Explorer 6.0 or later http://www.co.jefferson.wa.us/assessors/parcel/assessordetail.asp?Parcel_ NO=984900302 & Windows - Mac HOME | COUNTY INFO | DEPARTMENTS | SEARCH as Page 1 of 1 VECEIVE MAY 19 2010 CITY OF PORT TOWNSEND DSD 5/19/2010 Receipt Number: BLD10-108 984900302 Energy Code Fee - New Single Family | $100.00 $100.00 $0.00 BLD10-108 984900302 Mechanical Permit Fee per Dwelling U! $150.00 $150.00 $0.00 BLD10-108 984900302 Plumbing Permit Fee per Dwelling Uni $150.00 $150.00 $0.00 BLD10-108 984900302 Building Permit Fee $734.75 $734.75 $0.00 BLD10-108 984900302 State Building Code Council Fee $4.50 $4.50 $0.00 BLD10-108 984900302 Technology Fee for Building Permit $14.70 $14.70 $0.00 BLD10-108 984900302 Record Retention Fee for Building Per $10.00 $10.00 $0.00 Total: $1,163.95 10-0467 05/19/2010 PLAN REVIEW DEPOSIT 150 $150.00 BLD10-108 CHECK 217 $ 1,163.95 Total: $1,163.95 genpmtrreceipts Page 1 of 1 Receipt Number: 10-0467:2) 003 re Descriptio SEE BLD10-108 984900302 PLAN REVIEW DEPOSIT 150 $150.00 $150.00 $0.00 Total: $150.00 Recelpt # Paymen Method CHECK 214 $ 150.00 Total: $150.00 genpmtrreceipts Page 1 of 1 TABLE 6-1 PRESCRIPTIVE REQUIREMENTS” FOR GROUP R OCCUPANCY CLIMATE ZONE 1 Glazing Glazing U-Factor Door ® wauika Wall’? we wae Slab® Option | Area’: wad Ceiling? | Vaultee | Above © Floor? | on % of Floor | Vertical | Overhead’' | U-Factor Ceiling? | Grade | Below | Below Grade Grade | Grade I. 10% 0.32 0.58 0.20 R-38 R-30 RIS R-15 R-10 R-30 R-10 Il.* 15% 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 Il. 25% 0.40 0.58 0.20 R-38 / R-30/ R-21/ R-15 R-10 R-30/ R-10 Group R-1 U=0.031 | U=0.034 | U=0.057 U=0.029 and R-2 Occupancies Only IV. Unlimited 0.35 0.58 0.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 Group R-3 and R-4 Occupancies Only V. Unlimited 0.35 0.58 0.20 R-38 / R-30/ R-21/ R-15 R-10 R-30/ R-10 Group R-1 U=0.031 | U=0.034 } U=0.057 U=0.029 and R-2 Occupancies Only * Reference Case 0. Nominal R-values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher). Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. 'Adv' denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than 12 inches and (b) there is a minimum 1-inch vented airspace above the insulation. Other single rafter or joist vaulted ceilings shall comply with the “ceiling” requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. 8. This wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U-factor of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U-factors determined in accordance with NFRC 100 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. 4' — Ay a " 8' ’ — - 0 ” 1° - 0 5 % " 23 ° ap e — 47 / 5 , ” }9 ’ — 0 ” Washington State Energy Code. R-value markers are to be installed, at least one for every 300 sq. ft. facing the attic access. Markers shall be affixed to the truss or joist and marked with the minimum insulation thickness. PREMANUF AC URED TRUSSES © 2’-O"oc W/ 1/2” OSB SHTG., 15# FELT & ARCH. COMP. ROOFING ae i ao Rae INE. = 2 ad S S S S| S S| SIMPSON TIES EA. TRUSS = =! i) i S Ly ry od = = iS Cy EXTERIOR WALLS — 2x6 @ 16”0c W/ = =| 1/2” GYP. BRD., R-21 INSUL., 1/2” s = OSB SHTG., VAPOR BARR. & HARDY s S| LAP SIDING fe = it i i =a S 11 7/8” BCI'S @ 16’0c W/ 3/4” T&G r= CN ey S wy kN 4” CONC. SLAB = FON: PER PLAN ee Se RP ee Se Ca Oe Re Oe We SEC TION — A EXTERIOR _FINSHES: ARCH. COMP ROOFING HARDY LAP SIDING PRIMED SPRUCE FACSIA & TRIM 16’-0” MILGARD WINDOWS CONT. ALUM. GUTTERS 6:12 PITCH TYP. 24” OVERHANGS a Ce na FRONT ELEVATION 35 ’ - 0 " 24” OVERHANGS Section R401.3 (IRC) SIDE ELEVATION on ae r 1 4 t ; , ! ti i! 7 : Lie Ltt Lo tl oe Lh Lo ee Pe he eh ee _! = Ct tL UT el dT oT CT. LE Ld ptt tt. iy 1! beck bed te de Ll Ts TL rt ty bE EG GE ES SEE EL EE EE ES Gi GEG my i! LT LT dT he eT rT el +! Ly 545 | ES FS EL -EE E G F E S G G E i= ry zc eS See eres ae ie ee (ec ee eae Bes es es et is es Ee Bs es ee Be _t J J i! i ry] [| JT J JT J JT J ae ee ee ee ee ee Law a Jz). [J]. Tl a | [4 I LJ ry i ee ee as ee ee ae ee ee or wee ies eee Rae a le ae ae | (ean ae ae Ges a eee a ee i ee ee | tot i! I I I PASS Bae | T | ec AR Se! URES SS | I I I I I | aaa a | T I I I aa I | aa EY LC Te 7 ‘ | = 3 8 |r 7 H a = na IC + re Fall” aca = a IC ' | | NOTICE: Plans are annreved excepiina -T = PREMANUF AC TURED | Il | any errors or omissions. All work must ti TRUSSES @ 2-0 oc 2. — NEN | pass inspection in conformance with i! | — all applicable codes and regulations. = 6:12 PITCH : 5 ! Lots shall be graded to drain surface ry 1! a ae ERevOEn. water away from foundation walls. The Permit No: IjO-1 0% i i! SHIPMENT OF TRUSSES & grade shall fall a minimum of 6 inches By: TD, 7 ! HUST BE-ON SITE FOR within the first 10 feet. uilding Official et FRAMING INSPEC TION) CITY OF PORT TOWNSEND FILECC™ ROOF FRAMING FLED (9 -(O & pReEeD) ) MAY 19 2010 CITY OF PORT TOWNSEND DSD ection R303.6 - Stairway Illumination: 35 ' — 0 " lI MEINISHEA SECOND FLOOR PLAN 5’-0” 5’-0” 2 - —_ ” All interior and exterior stairways shall 16-0 be provided with a means to illuminate the stairs including the landing and treads. : BN mcs OY ee a as Died oa = U U U Ui 1 | h 1 | U qT 1 1 | U I 1 UJ 1 t U U 1 it pe ‘Ties (ites ‘nied a ae KS oo: eu ro) é i 1 oft Ui ; it () PN itt i ETE EL BEET ae us | oo ft ' re en eo hoot ! re) L lh \ it i hob POU Rt ed |e f f i f f | 1 ! 1 i LI 4 ees | eee | ae HALF WALL j; |[ 2 ( SAFETY| GLAZING nn a go fo: o ; 12 x8 FTG. UNDER WALUS & % | Ol - fr ee tO : 7 " re Oo i lg | nH xO | i 2 | 2 oJ = ~t ———ee “ My SSS SSS SSS . 1 ! Seals and Weather-stripping: (Air Seal) + ¥ o : © A nee Openings shall be sealed, caulked, gasketed, or S.A S.A, weather-stripped to limit air leakage. Exterior . F = rw f ‘ ! joints around windows and door frames, openings t=) fe: eel | ie aero a ge ee at penetrations through walls, floors, roofs and es | 20 MIN, RATED % other openings in the building envelope. 4-0 Nt i : PooR ‘ Lt 1 Py 1 yy C —— ! PROVIDE VENTED o Wy 14778" | WINDOWS OR FRESH J oe 7/8" BCI 60 2.0 A\R PORTALS 0% * ff © 16”0c ABOVE ! -~WHOLE HOUSE FAN- pe Ww xO ! | | 2 wo S a © n — a 1 tl - 45, i i 4 ! GARAGE ! ’ ” ’ ” | ¥ 5 -3u% 9-91% m9 4” CONC. SLAB i , 1 | : y oaM ! fo) S, , 7-6” 4 | ! 9-9 TALL WALLS ! ! | it: = ij mee f. ; Section 30¥.2 Garage Separation ' ; c : 1 ' The garage shall be separated from the \ B ATH ' = a : x residence and its attic area by not less than 1/2 ' ' 1 ' s inch gypsum wall board applied to the garage ; ' - Ny 5 ; [> side. Garages beneath habitable rooms shall be i : = ? Ny a ! 1 Uy separated from all habitable rooms above by not I ! Te ; » o /. x ' i. < less than 5/3 inch type “x” gypsum wall board. : : 8 2 GG fy A Whig ai SOCEM MIN Z xO d i oOA\ oy, oe: | dt : pa % vw qi) 4 at Le n BM TT eee SE SS ee I l | v KX Zw 9, ! ; | KITCHEN io {6.2 ' 3 ETT (00 CFM MIN G/V ry re a L Se 1 / 1 a ' ' I xt. wv, | ee 3'-6" >2i5- S fo | ! if c1© © /\ 7 ! mae LJ ' 4 t y $ : oa 1 4 A a \ TI | ' oO (o) [e) OF on i ee.) | 2819 ©} l ge © : LH S i er ‘ 2 W/O o ; WH, AS ae WwW t o 6 f’ | ~ 4 10’-0”x8’—0” 1 \ y |SO CFM li rm] x (Giant “\ {2 brill mall wien OHO NDR. 2 i-2s2-2 ! (oh m™ : i: eee” ’ ” = ’ ” = BM a ag ed 8, RSE a SN A at te ye Pas Rae merci carn een aoe SLIDER 5 —Q” | 6’-(” 5’-Q” 3’-0” 10'=0" 37-Q” TYP. 2x6 EXT. WALL JNDER SLAB STEM WALL ¢ FTG. DETAL GENERAL NOTES | —*4 HORIZ. TOP FINISH GRADE ‘© —=T=T cl ; 4 Tada eels TRID. 2:6 SILL W/ 1/2"xIO” MIN. ANCHOR BOLT 4'D"0c AND 4" min. / 12" max. FROM ee OIPLATE ¢ 3"x3"xl/4" SQ. WASHERS 9 Fall at? +4 VERT. |'-6"oc -_ ya,>be a" | | 2) °4 HORIZ. BOT | re CONTRACTOR TO VERIFY ALL DIMENSINS & OPENING SIZES BEFORE CONSTRUCTION. ALL EXTERIOR HEADERS TO BE 4x10 JNLESS NOTED OTHERWISE, W/ 3” MIN. BEARING FOR OPENINGS OER 5’-0” WIDE. Section 508 - Uniform Plumbing Code. Water heaters shall be strapped at points within the upper and lower 1/3 points of its vertical dimension. At the lower point, a distance of not less than 4" shall be maintained above the controls with the strapping. FOUNDATION/FLOOR PLAN ALL INTERIOR HEADERS TO BE 4x6 WLESS NOTED OTHERWISE. EXTERIOR & INTERIOR BRASED WALL ?ANEL PER CODE: EXTERIOR — (1) 4’x8’ B.W.P. TOSTART 8’-0” MAX FROM EACH BLDG. COINER & EVERY 25’-0"oc. STE nate a B.W.P. TO BE Mil. 3/8” RATED SHTG. OR SIDING NAILED W 8d @ 6”0c EDGES & 12”0c MIDDLE. 1(—0” MAX. HEIGHT. v BLOCK ALL EDGSS. INTERIOR — 1/2” G.W.B. FASTEND W/ 5d @ 7”oc FOR to cover. Shear wail nailing and holdowns are to be inspected and approved prior 8'—0"x8’—0” ON (NE SIDE OF WALL OR 4’—0"x8'-0” ON WO SIDES OF WALL. SPACE 25'—O"oc. (1 EXCEPTION ALLOWED) (VERIFY OTHER OFTIONS FOR BOTH W/ BLDG. DEPT.) ALTERNATE EXTERIOR BRACED WALL PANEL W/ (1) OR (2) 1800# HOLDOWNS. SPACE FROM BLDG. CORNERS SAME AS ABOVE. W/ 8d @ 6”0c EDGES & 12”0c MIDDLE. 10’-O0” MAX. HEIGHT, BLOCK ALL ED(ES. Sec. 602.10.6 (2), IRC - Alternate Braced Panels Two Story Building 2' 8" min. width, 10' max height, sheathed on both faces with min. 3/8" structural panel, nailed with 8d common nails 4" o.c. all edges and 12" in field. Provide (3) anchor bolts & two tie-down devices capable of providing uplift capacity of 3000 Ibs. 2’-8"x8’—0” MIN. SIZE NAILED oo