Loading...
HomeMy WebLinkAboutBLD10-156 - drawings AN JAMES R “wee STATE OF WASHINGTON fa > fe a > am CODE & ZONING INFORMATION DRAWING INDEX SCOPE OF WORK WORK BY OWNER SITE INFORMATION BUILDING INFORMATION A0.1. LOCATION MAP, CODE & ZONING INFORMATION, EXPAND EXISTING BATHROOMS PROVIDE & INSTALL NEW WALK-IN SCOPE OF WORK, GENERAL NOTES SONDENOEeS, A1.1 EXISTING CONDITIONS & NEW WORK SITE PLANS . = LOCATION 414 KEARNET STREET, PORT TOWNSEND, WA BUILDING CODE - 2009 IBC A2.1.__ EXISTING CONDITIONS FLOOR PLAN BESIDEL EXISGiitoastsCMEn fs) A2.2 9 NEW WORK FLOOR PLAN REMOVE & REINSTALL - ZONING CLASSIFICATION COMMERCIAL DISTRICT TYPE OF CONSTRUCTION - 5-B A2.3 ROOF PLAN ADD NEW FREEZER / COOLER / STORAGE ROOM (E) KITCHEN EQUIPMENT = C-ll GENERAL COMMERCIAL A3.1. EXISTING CONDITIONS BUILDING SECTIONS oO NUMBER OF STORIES -ONE A3.2_ WALL SECTIONS & DETAILS ADD NEW OUTDOOR EATING SLAB PROVIDE & INSTALL i | A3.3. WALL SECTIONS & DETAILS N) KITCHEN EQUIPMENT a TOTAL SITE AREA 1.11 ACRES OCCUPANCY CLASSIFICATION - COMBINED B &M A3.4 DETAILS UPGRADE ELECTRICAL SERVICE - A4.1 DETAILED FLOOR PLANS & INTERIOR ELEVATIONS LOT COVERAGE EXISTING BUILDING FOOTPRINT = 10,777 SF = 22.2% ‘ _ TOMATIC FIRE SPRINK YSTEM NOT REQUIRED P iB TI A4.2. DETAILED FLOOR PLANS & INTERIOR ELEVATIONS DISCONNECT & RECONNECT KITCHEN RQUIPMENT Ww PROPOSED BUILDING FLOOR PRINT = 11,236 SF = 23.2% | AUTOMATIC FIRES Pena Ewan Reet SRB SEE TION 8 A4.3 DETAILED FLOOR PLANS & INTERIOR ELEVATIONS = _ A5.1 EXISTING CONDITIONS EXTERIOR ELEVATIONS Q OCCUPANCY CLASSIFICATION MIXED-B&M EXISTING FLOOR AREA = 10,780 SF A5.2. NEW WORK EXTERIOR ELEVATIONS DUT LOOR RES FROPISER S| Soa K-1 KITCHEN EQUIPMENT PLAN & SCHEDULE ALTERNATES LEGAL DESCRIPTION SECTION 11, QTR. SECTION NW1/4 TOTAL (N) FLOOR AREA = 11,234 SF M-2.1 MECHANICAL SCHEDULE & FLOOR PLAN a TOWNSHIP 30N E1.1 ELECTRICAL — SITE PLAN, LEGEND & NOTES om RANGE 1W ALLOWABLE FLOOR AREA PER IBC TABLE 503 E2.1 ELECTRICAL —EXISTING/DEMOLITION PLAN #1 ALL WORK RELATED TO REMODELING & BS E2.22 ELECTRICAL —- POWER PLAN EXPANDING THE TWO PUBLIC BATHROOMS iN vA PLANNING AREA PORT TOWNSEND (1 ALLOWABLE TYPE B FLOOR AREA PER TABLE 503 = = 9,000 SF E2.3. ELECTRICAL — LIGHTING PLAN AT THE NORTHEAST CORNER OF THE BUILDING. 6) N (1) ALLOWABLE TYPE B FLOOR AREA PER IBC 560.2 =11,584 SF E2.4 ELECTRICAL —ANCILLARIES PLAN fo : - SUBDIVISION MABEL ADDITION TOTAL PROPOSED TYPE B FLOOR AREA =10,265 SF E2.5 ELECTRICAL — ROOF PLAN #2 ALL WORK RELATED TO ADDING THE OUTSIDE Yoo 2 \ E3.1 ELECTRICAL ~— DETAILS EATING PAD. 4 n OD ALLOWABLE TYPE M FLOOR AREA PER IBC 560.2 =11,584 SF E62 ELECTRICAL - PANEL SCHEDULES #3 ALL WORK RELATED TO MODIFICATIONS OF THE 5 a 4 a PROPERTY DESCRIPTION BLK 76, LOTS 1 THRU 7 TOTAL PROPOSED TYPE M FLOOR AREA = 969SF GRAB & GO CASE. i» 4 2 : S 4 a oO _ ANSITE EXISTING PARWING SPACES a7 FLOOR AREA INCREASE CALCULATION PER IBC 506.2 DESIGN TEAM #4 GRIND THE SURFACE OF CONCRETE MEAT ROOM T/ 20 XO If = (F/P-0.25)W/30 : FLOOR SLAB. > “or ue) ONSITE PROPOSED PARKING SPACES —_ 47 (UNCHANGED) F = 256'-9" P = 478"-0" W = 30'-0" Fr eracerin A esac per ene ti, 707 If = (256'-9" / 478'-0" - 0.25) 30'-0" / 30 JAMES WILLIAMS ARCHITECT GOEDEKE ENGINEERING @ £09 if = 28 3131 HILLIARD STREET GREGG GOEDEKE VY) “ Cc : ie BELLINGHAM, WA 98226 17119 SE 47TH CT > @ Wud . PHONE 360-733-2581 BELLEVUE, WA 98006-5805 < ~ OZ 2 Se STING SR OROSED: TOTAL Occupant Load Calculations EMAIL jimwilliams15@comcast.net PHONE 425-644-5899 tig d 03 FAX 425-401-1250 nol of% WATERCLOSETS 3 2 5 Mercantile 7,036.6 @1/60 =117.3 Laecyaeri r= maa EMAIL struc! @msn.com SYMBOL LEGEND /ABBREVIATIONS Ww uO | . _ J WORK SINKS 4 0 4 Business 761.5 @ 1/100 = 7.6 7650 S.E. 27th St., #403 K ENGINEERS, INC. es is HAND SINKS 1 1 2 Bathrooms 431.7 @ 0.00 = 0.0 MERCIER ISLAND, WA 98040 STEVE TEVELDE : ) pw DISH WASHER 1 0 1 Commercial Kitchen 725.9 @ 1/200 = 3.6 PHONE 206-223-6447 208 THIRD ST (E) 8" CMU Der Reswised z Sommirtég Loo MOP SINK 1 0 1 Accessory 146.9 @ 1/300 = 0.5 FAX 206-223-6465 LYNDEN, WA 98264 (E) 8" CMU TO EXT. w/5 1/2" WD. STUDS @ 1'-4" 0.C. TO INT 4-22-2d \\ "i Total Occupant Load = 136 CELL 425-306-2677 PHONE 360.354.4757 x 14 wi R-19 BATT INSULATION & 5/8" GWB email § goren@cegginc.com FAX 360.354.6794 cw (E)5 1/2" WD. STUDS @ 1'-4" 0.C. wi R-19 BATT INSULATION, email SteveTeVelde@k-engineers.com 5/8" GWB TO INT., CEDAR SHINGLES OVER 1/2" PLYWOOD TO EXT. REVIEWED FOR CODE (E) 5 1/2" WD. STUDS @ 1'-4" 0.C. w/ GWB ONE SIDE COMPLIANCE STRUCTURAL NOTES GENERAL NOTES (E) 3 1/2" WD. STUDS @ 1'-4” 0.C. w/ GWB BOTH SIDES . ; fe (N) 5 4/2" WD. STUDS @ 1'-4" 0.C. w/ CEDAR SHINGLES OVER 30# FEE Aen ne “a “y & 1/2" PLYWOOD TO EXT. & 5/8” TYPE X GWB TO INT & R-13 THERMAD Si y le LOIS - 1S5G All work shall be in conformance with the 2009 Edition of the International Building Code (IBC). TYPICAL THROUGHOUT. & 3 1/2" ACOUSTIC INSULATION BY \\\ -_ \ F INS fonds: 2. CONFORM TO ALL APPLICABLE CODES AND ORDINANCES, THE cay (N)3 1/2" WD. STUDS @ 1-4" O.C. w/ 5/8" TYPE X GWB BOTH SIDES - - Wind V3s = 85 mph, Exposure B MORE STRINGENT TO GOVERN. CES) & 3 1/2" ACOUSTIC INSULATION Earthquake Design Category D, Use Group | 3. DISCREPANCIES BETWEEN CONTRACT DOCUMENTS AND CODES cas (N)5 1/2" WD. STUDS @ 1'-4" O.C. w/ 5/8" TYPE X GWB BOTH SIDES NOTICE: Plans are approved excepting Roof Live Load 25 psf (snow) SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT & R30 INSULATION Dale Wepection In onisemee noon Roof Dead Load. 15 psf PROMPTLY AND RESOLUTION OBTAINED BEFORE PROCEEDING. (E) WALK-IN FREEZER OR COOLER WALL all applicable codes and regulations. FOUNDATIONS 4. DRAWINGS ARE SCHEMATIC ONLY. DO NOT SCALE THE @ED (N) WALK-IN FREEZER OR COOLER WALL All foundations are to bear on undisturbed native earth with minimum allowable bearing pressure of ages FNL Dic GaNROHENTS ARE Noe ewanaeore all. (E) 3 1/2" WD. STUDS @ 1'-4" O.C. w/ PLYWOOD ONE SIDE 1500 psf. Exterior footings are to bear a minimum of 1'-6" below finish grade below organic surface , fs a soils. Backfill is to be compacted to 95% of maximum density per ASTM D-1557. Provide a DRAWINGS. LOCATIONS AND SIZES ARE APPROXIMATE. CS) (Eps 2 WE. STUBS @ Tea" O-0: Wi PEP BOTH-SIDES minimum of (2) #4 continuous at bottom of all footings. 6. THE CONTRACTOR SHALL FIELD VERIFY ALL EXISTING CONDITIONS ABBREVIATIONS CONCRETE PRIOR TO THE COMMENCEMENT OF WORK. ANY DISCREPANCIES Concrete strength is to be f'c = 2,500 psi with a maximum water/cement ratio equal to 0.67 for SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT. NO (E) EXISTING i SUL INSULATION non-air-entrained concrete and 0.54 for air-entrained concrete. Minimum sacks of cement per cubic WORK SHALL COMMENCE WITHOUT FIELD VERIFICATION BY THE (N) NEW INT INTERIOR yard of concrete is to be 5.5. CONTRACTOR. 9 RELOCATE / RELOCATED LAV LAVATORY 7. IT SHALL BE THE RESPONSIBILITY OF EACH CONTRACTOR AND Bor Scala “ot 26 MEE SORGREIE REINPOREEMENT SUBCONTRACTOR TO REVIEW ALL OF THE CONTRACT DOCUMENTS = All reinforcing steel is to be ASTM A615 grade 60 (fy=60,000 psi). Welded wire fabric to conform to CMU CONCRETE MASONRY UNIT MO MASONRY OPENING Q.. . oO ASTM A185. Minimum concrete cover for reinforcement: 3” for concrete poured against soil, 2” BEFORE ORDERING ANY MATERIALS OR BEGINNING ANY WORK. CONC CONCRETE MTL METAL (@) > z N for formed concrete in contact with soil. Extend horizontal wall steel to 2” from outside face and EACH CONTRACTOR, SUBCONTRACTOR OR INSTALLER SHALL BE DEMO DEMOLISH & REMOVE Oc ON CENTER 1 on Q = lap with elbow bars (30 diameters) of same size and spacing. RESPONSIBLE FOR VERIFICATION AND COORDINATION WITH OTHER oe BIMENSIN i PRESSURE TREATED OY |& _ CONTRACTORS, SUBCONTRACTORS AND INSTALLERS TO’ASSURE oe SOT SPSUT eee ie ON |s |& Slab Reinforcement: Rigidly support steel using concrete blocks or chairs manufactured in COMPLIANCE WITH THE CONTRACT DOCUMENTS O PLBG LUMBI Q Zz ow oi accordance with CRSI standards. Nonstructural slabs on grade are to be a minimum 4” thick : EA EACH SCHED SCHEDULE = O ac placed on gravel fill and reinforced with 6x6-W1.4/W1.4 welded wire fabric. Interior slabs on grade 8. ANY WORK INSTALLED IN CONFLICT WITH THE CONTRACT ELEC ELECTRICAL SS STAINLESS STEEL Oo oO. ae) are to have approved vapor barrier with proper sub-grade preparation. DOCUMENTS SHALL BE CORRECTED BY THE CONTRACTOR AT THEIR EXP EXPANSION STG STORAGE O S< O Lu OWN EXPENSE AND AT NO EXPENSE TO THE OWNER OR ARCHITECT. a SE UNDATION _ eaaae uii | 29] g Ny CC Oe a é Sinica nad lumber is to be stress grade Douglas Fir (DF) #2. Grades are to conform with =) BE eS N ASh ee a ee. ole FO FACE OF TP TOILET PAPER Q og 5 Zz s | Os Ae eh 7 ‘, at “WWPA Grading Rules for Western Leute current edition, , BRACING AS REQUIRED DURING DEMOLITION AND CONSTRUCTION. FOIC FURNISHED BY OWNER TYP TYPICAL = N © a ss \ : 10. PROTECT ALL EXISTING BUILDING COMPONENTS, SURFACES AND INSTALLED BY CONTRACTOR UR URINAL LW a ou iF S Bolt heads and nuts bearing against wood sill plates are to have cut washers. Wood bearing on or LANDSCAPING FROM DAMAGE. ANY PORTION OF THE PROJECT TO FOIO INSTAMLED BY OWNER - We BARRIER 2 O A a Is installed within 1” of concrete is to be treated with an approved preservative. Typical sill bolts are to REMAIN WHICH IS DAMAGED BY THIS CONTRACT SHALL BE WwW _ O° g5 be 5/8” diameter at 4’ 0".0.c. with at least 7” embedment using minimum 0.229"x3"x3” plate . RETURNED TO ORIGINAL CONDITION AT NO ADDITIONAL COST TO aie one REINFORCED PANEL WD bial, CLOSET = ie oO < washers. Light gage metal framing connectors and their required fasteners are to be “Strong Tie THE OWNER : On GAUGE wine WINDOW oO > oO. is Ps . : : oe : i ; d 1. All nail hol fi . f eet a0 , Ae — Std EtGler oliea wie det ba retiati, #20254. aioe ees aclvented 11. ALLOW NO DEBRIS TO ACCUMULATE ON THE SITE. IMMEDIATELY GWB GYPSUM WALL BOARD 2 DIAMETER FO |=s2| g eo es mV 4 ROJEC CATION common. REMOVE ALL DEBRIS AND SALVAGE FROM THE SITE. PROVIDE HM HOLLOW METAL be ele Zz 5 < ve Haghee OTREET ncywooo WEB JOISTS DUMPSTERS OR DUMP TRUCKS FOR REMOVAL OF DEBRIS. DO NOT Cera a onl a PORT TOWNSEND, WA Joists shown on plans as “TJI” are to be “Trus-Joist” or equal. Joist assembly to be tested under ra SHEE | CONSTRIICUON BELL is 5 a rar nl peat THE oO 5 QO e IBC procedures. Complete joist designs bearing the stamp of a Professional Engineer registered in : : (aN Oo ie 2 = the State of Washington to be submitted for review. Joist manufacturer shall provide all specialty DETAIL SHALL BE THE SAME AS FOR OTHER SIMILAR WORK. SECTION MARKER €s) (E) SMOKE DETECTOR _| CONCRETE ae items for a normal and complete installation of the joists. Truss manufacturer to confirm, prior to 13. GUARD AGAINST HAZARDS TO BUILDING OCCUPANTS, \as.y ; VICINITY / SITE MAP fabrication, the location and weights of mechanical units. PEDESTRIANS AND WORKERS. EXITS, WALKWAYS AND LOADING NTRACTOR 1 GRAVEL CO —— aLywoop DOCK MUST REMAIN ACCESSIBLE AT ALL TIMES. esTs e DETAIL MARKER (AS) (N) SMOKE DETECTOR BID SET a , 14. THE CONTRACTOR SHALL KEEP ALL BUILDING EXISTS CLEAR AND Plywood roof, and wall sheathing is to be C-D INT-APA (with exterior glue) per IBC bearing APA stamp. Minimum nail size is to be 8d common. Maximum nail spacing is to be 6” o.c. at all panel ACCESSIBLE AT ALL TIMES AND PROVIDE PROTECTIVE ENCLOSURES » ELEVATION MARKER SOIL edges and 12” o.c. at intermediate supports. THROUGH AND / OR BELOW WORK AREAS. aint! TENN) Gin AO 4 Stagger end laps at roof sheathing. All panel edges are to be blocked at walls and, as indicated on IN NORTH ARROW Sossons INSULATION Sheet # 1 of 25 sheets plans for roof and floor sheathing. Support is to be supplied to all plywood edges with plyclips, N Job Number blocking, tongue and groove plywood joints or other approved method per APA recommendation. i\\\ eULATION FLAG NOTE MARKER VICINITY PLAN / SITE PLAN <:) 220'-0" $525 | ARCHITEGT + 144'-10" 75'-2" 4'-9" 8'-5" 24'-6" + 107'-2" 25'-0" f JAMES R WILLIAMS — ae eee — STATE OF WASHINGTON Ea (5) CONTRACTOR PARKING SPACES (5) MORE SPACES WILL BE PROVIDED (-) IN THE CLAY ST. CO-OP ADMIN. = BUILDING PARKING LOT Y i < - A43 © © Q _ > _— ~ _— ~ - ee ——e “yy Ou tal RAR, aR a RA ens < £0 Pre ae ¢ al we VK fe KOS ‘ ad 4 z ee f c CAESSSISSSG SS AS x “s ° j x We PU ROA a ¢ 2) eee . <a / LPT PAE CRSA ele CAAA ee, ee — jee - “ ey he a Adee. x ee . Pare 4 Par. ~ eer. SNS SRS ON OVS Vee bee © ‘. ae, Ne : oe i ys V3 ° ——— xis a4 | 4 Fe ™ ta ’ ae a fee ai | 3 —_—— : || nat] RESAE {x fr i | saa a eee i een 9G ine wi | 7 all | salen de NN tvs MOS a c | 3 To D t LSS SSIDS is sy o ; he ASAD > say eae oy.” >» > a 4, 4 wi ne Ww oe Ww ma WA Sa = \s! ac s ener < 5 1Ot ee < w iw w b —— x ‘ ~4 x ©) rca} AG ph t ‘ z J o 2 me xn & nee 8 an Oo en cee Qe ‘e L 4 FF _—— 8 ert: aN . = or. p y ws a 3% o Soe +) a a °8 a “oho ZG u in = < PARKING LOT & LANDSCAPING TO REMAIN UNCHANGED PARKING LOT & LANDSCAPING TO REMAIN UNCHANGED mz <x) GG oo 5 ex ee RED ns, =| } xs = : < % .s. wg eo its} ae - os Ry x P ae = “eee eof . WTAE AAR te csreeinenracnnccsinciteitieticnset etna ie We 2 Pi Ne Md 3 ¢ Pe a ene me et NNN ee TT ae ee -— — ne ee L es ih / we on, a oe ( | / NEW WORK SITE PLAN c EXISTING CONDITIONS SITE PLAN ess i Scale: 1" = 20 ft Scale: 1" = 20 ft oe i FOR INFORMATION NOT SHOWN he NORTH | NORTH NORTH NORTH sh ae SYMBOL LEGEND SYMBOL LEGEND SITE PLAN FLAG NOTES CONTRACTOR LAY DOWN AREA (E) LANDSCAPING, GRASS PRO METER OR UNDEVELOPED VEGETATION aa) (€) PROPERTY LINE (2) (E) PROPANE TANK - NO WORK “ (E) ASPHALT PAVING <3) (€) DUMPSTER - NO WORK a = . Oz (E) CONCRETE WALKS OR SLABS <4) (E) RECEIVING SLAB - NO WORK oO oO - — imed as) Own x Ree (E) GRAVEL SURFACE a(S) (€) FREEZER - NO WORK a a 2& 7) (E)STG. SHED - NO WORK Oe Ox 0 Lid s < 92) |: =! B35) |: pl 22 = - 25 o> ” FO =| = 4 < $ ao Ww a| = Oo& wi |, = O. Be 4 7 CONTRACTOR BID SET A1.1 Sheet # 2 of 25 sheets Job Number JAMES R WILLIAMS STATE OF WASHINGTON WO O LS V O N O O O S LS W Y I T m i M N i T - TI V w W a LB S S C - E E L - O 9 F AN O H G L4 E P - 9 S 2 Z Z 8 6 VM ‘A V H O N I V I S S ‘p o z o e xO o s Od d. A u d d V Ag NO I L d I d 9 S 3 a d ai v d Aa d QJ a D S " N LO A L H Oe y Sw y i sa w y LL O Z ‘L E Wd u d v ae g SA I V I T I M WI E Ag pe n a i d d y SA V I T I I M WI P AQ U M B I Q NV 1 d YO O 1 S d SN O I L I G N O O ON I L S I X S NO I S N V d X 4 ’? NO L L V A O N S 3 Y dO - O 9 GO 0 0 O 4 GN A S N M O L LY O d CONTRACTOR BID SET A2.1 Sheet # 3 of 25 sheets Job Number 144-10" 20'-10" mm mm nn a en ne ee te me ee d 20'-6" 94.0" 20'-8" 20'-8" 30'-8" 20'-6" a. $C |GRIGR OUTSIDE DINING SLAB FRIG FREEZER { | | | | | | A | < | aS v O 30 n g o u d CHECK OUT CHECK OUT FLOWERS REFRIGERATOR ISLAND | | | | | | | | | | | | | | | io | | | | | | | | | | | | | GRAB & GO CASE {ope SA O FRIGH FRIG AS V SD I A N S S 11 4 0 PRODUCE CASE ST V L WY O M Ad O O D SL V O O be SHED Wie WALK-IN EXISTING CONDITIONS FLOOR PLAN Scale: 1/8" = 1'-0" FOR INFORMATION NOT SHOWN SEE SHEET A1.1 TRUE PROJECT NORTH NORTH RECEIVING | | a | oe re ae ) Ea | a | | | | | | STAFF we l l Z~ . L E ah h L1 L € LL O Z ‘L L Wd u d v SW V I T I I M We SW V I T I I M WI P ae d Aq pa n o i d d y Ag um e u g «d 4, 2 WO S ' L S V O W O 9 O S I SH w I T i M n i r - TI V W NV 1 d YO O T S HO M MA N | , be 5 2 L\ S 8 S Z - € E 4 L - 0 9 6 AN O H d a a i = 23 LL E v - 9 2 2 8 6 VM ‘W V H O N I N I S S ‘v 9 z 0 e xo s od : a 7 8 ee te DE R X == w ww id N < nS bd — \ : ; i Q < * Zu Ca v a n LO L A ey Sw v i r y Le NO I S N V d X 4 8 NO L L V A O N S A d zo in Pi a a “ 8 y dO - O 9 GO 0 O 4 GN A S N M O L LY O d | © Z Q. A N d V Aq NO I L d I d D S 3 a ai v d Aa d 8 —— ) OU ye 3 eo NS — a ra é¢ * wy re \ nd FA Q s = al l a %. sa << SY = = = ‘ {> > <= A ({ = DB D = : i- YW Ss | ai d | | < | | | | | | | | | | | OD 6) ro ) oO | i = pa Po ai a i i a i a a i a i a a e a O [ F t £ i= s © ¢} . = Q o 2a _] Zz Oo £ ry ‘ s) fr e 2 ES iN Ye AO ZX ok : ad Es Lu lu oo s 6) a = = 5 % \ \ o| 6h Oo : Es = \ \ a iz ‘o ) oO Zo F& F OF .! we | a re s QD iy Q i - Zz = 4 ui an uO o\ : ¥ A = pe = 2 3 fe ‘ i = = . se e k 35 \ | / Yi n $2 eS el w gt d \ | ©, Ol e . &r ee te s z t o ee Se ou so s s e e e z Z i. ) cz | 3 25 su 2 0 8 S 3 rl S/ O xy Wo a k z u i 2 ee ee e ee e ee n ne ms t . nm e nt te Ss et en es ms i El nl O mi s ow Fe q d i a , @ 1 29 £a ue ON OF w Zi d Qu t u b ” = | 1 \. - - - - - - : Sa z e r u e | 3 ) ia d i Ye fs os e at r o d a a r t Wu y me 5 5 | ts > | ( 3% 3p 8 | B | Sl | ME S : 2 Z 6 6 th | x 5 5 we 7 | QP ue i = | (M W ) 28 oe a i O 9 O OD rz | 7 ty | | | | | | OO —— — — Ss ee Ce ee - o eA | S | x | | : OO (= | O ) J | = 2 a | | : = 4 o a il N ) 29 | NN oe | a 2 | rs : B )| J i = i a ©) a i « gn Q in o "3 2) oe © 2. i aS v O 3O N G O u d mz a : Q = oO i + Se Oo m a e t t s t © : - ca e : o| . Me ws = . “I F | 5 | ~ i te sa e po s 4 ae ss wo = “A _— } a << & ) pg ~ i > > =| 8 OE BE L ob yl <> \ yo <v rw e o L e =| 0 9 Oo , < KR ] x 3 =z © we J La y =a , . uc i b bE ~ B L 62 So u ? Se a t — of me m jo n re n ew e s er e 7 em e r se y nm e rm a ma e in -l w oj OO O. — - — Se Sb Se s ) Se a ee Si i a G i a i m i i c a a a l \s i c i a i a i n d u i s s c i i i d +] — - - 2 - es | Eu 5 ow = | J ee u i t s —_ " © a ua sw o “ po 2 i aW O O Ww a F <r o r m a / Ss — = | - é ae ru e — 30 ] we x] I i / + | S I =< ij iw 1 £ Z I~ t me uw i i cS ) , | e I mo O ow , = ne — mw tu ! if a By 1 a) ti 1 i r I a7 il n \ I | 2 Se we f Qe ee ee ee Pt mn nt ne me s mm mn fg fo m me m e Ei fm me es Ef i mm fa a el l we y co \ | be e ! S8 3 8 \ i ra e ee e i —p , s a a n a . J iI ~? mr ‘ @ © ri D i | “4 a _ ie a \ re teensy Fe 3s v 0 SO N S 11 3 0 EA , 20'-8" 24'-0" > Fa |S —— FRIG FREEZE ! I 1 1 i i ! | , mS 1 ' M 1 i 1 1 1 i 1 t L. ! I | I | | T | I I I I ' I I I I | I I | it ee I ] | pa | | | cts, didiaeeaieaminaeiaiiaaad: \' iiaiiiaiabiaiaeiiimadiiiiaiiinass \ “aliiad ‘a “adcibiiiaial ne acc sl freee en ee ne ee ee ee — (6) ppp | | ? | ~---1..--- ; @ ‘ LL } : x a1 a v l WH O M Ad o O d | SL V O O Fa g a y n g § i | 1 7 1 I 1 ai l TS 1 | ; I io IF ' ee | | Li t e m ey ) |) | +H "a n c l 4 1 : : i i | I ke ) © - -* i | i ‘ P i | x me Op p : a en i »0 - . 6 4 , a/ b L1 L E wl } 27 L € AS L 526 A\\\\ JAMES R WILLIAMS STATE OF WASHINGTON © ® @ QO © 6) @ i | | | 144'-10 | | | i > | 20'-6" | 20'-8" | 20'-8" | 20'-8" | 21'-0" | 20'-6" | 20'-10" o. ? ? ? ? ? sf bg ? < FA + 8'-11" ‘ : 24'-0" 4 i / ! / i | | | | | | | | | | | | | | > ie - | i ———— | i { Sed . o Jy i! | | | | i a | | | | | } VALLEY S| : aw | : | i Fs i | _., | ! ! | | | I i doe ; EL | i 1 | SHER Bin | | = eel bel Lal | 4 i | al mini | Ly | | 2 | rs) | o4 ——o—1) fe) I 1 - | r 1 a | ! 1 *) ~ t I oO | I 1 a I eve sees pe meet me tates ates anne ss anne seem nee mi man cee et esse sn atte soem weed J Q Ji: nl 4 t : ; 2 ° w o- 5 © n/a a | a eal ' ro) | io > ) V/ / “J ty | R iN | o) ny g eT s S | Nia a i N 9 | 4 n 4 >» B @ i 8 4 fan eee seen sete tent sea: ene one: 2] ‘ os eee . -< | ne < | & $ DO | > | E Na | ‘ | -] ee eases °} ae < 1® i : Oe a | & we ERS ae ” < 4 Z29%4 o|—-y® ERE eae 2.4 wu 3 Galt : je gid 82 2 rn eT | a oo ala ¢+ 8 —OT yom of ’ ib , : | 2 on 2 | t> v3 | 1 as | “| 92 | O o| ~<a ) mm 37 ' - 7 1/ 2 " : t+ a en e po aS Pe . 0 4 so l e be s t ie i i t a t i I hn - © © 4 Y) x ROOF PLAN oO. an a gqq m oy ARR Scale: 1/8" = 1'-0" Oo <{ “ sor I ~ f aa NORTH NORTH 1. (E) ROOF TOP COMPONENTS ARE SHOWN IN APPROXIMATE LOCATIONS Le ial g a Se V, Q < = ROLL LEAD FLASHING og = MINT BOWN INGIDE PISS aaiaernee eee (N) TORCH DOWN ROOFING Yy (N) RTU Z - = 2x12 P.T. > +6" WIDER THAN RTU 2 = WOOD CURB om SCEE METAL a SET IN PER FLASH ADHESIVE ROOF PLAN FLAG NOTES YO ss (7 ERTMETAL (N) PLUMBING VENT STACK >= is Cm: (2) REQUIRED FOR (E) (N) RTU <ai(3) (N) METAL CAP FLASHING = — eS (E) TORCH DOWN Oe AMON “{) (&) TORCH DOWN ROOFING < (N) METAL SCUPPER & DS MATCH (E) 5 < - ‘i ROOFING (N) DERBIGUM MEMBRANE (2) (E) METAL CAP FLASHING CONNECT TO (E) UNDERGROUND ia ra Z| o . 4 (N) DERBIGUM MEMBRANE 43) (€) SKYLIGHTS ioeerlecnes ele > | 2 \ | ELASHING (E) TORCH DOWN W: - o| = an | - N DERRIGUM FLASHING BOERS <x pene Che <<) Pa ee ee eee ae fe cc O = 4 Ne MEMBRANE ‘ j= SSN (N) BEAD - DERBIGUM <5) (E) RTU (N) WALK-IN COOLER BELOW - FOIO oO O 4 e , T a . . :S APPROVED CANT STRIP NL g SE Husuine sas ptyis)__(E) RIGID INSULATION CER EASE AGHESNE (E) RIGID INSULATION _ (©) (E) wood TRELLIS a7) (N) WALK-IN FREEZER BELOW - FOIO ees SET IN BITUMEN © ‘ @ PERFLASHING ADHESIVE \ AGEING. BONN ~a{7) (E) SCUPPER &DS (N) MEAT COOLER RTU - FOIO - LOCATE ABOVE (E) GLB ee (E) WOOD ROOF DECK = ~@{(s) (E) GLB BELOW (N) WALK-IN COOLER RTU - FOIO - LOCATE ABOVE (E) GLB CONTRACTOR (E OOR BOCr Beek N) GRAB & GO RTU - FOIO | BID SET was) (N) - awa20) (N) WALK-IN FREEZER RTU - FOIO - LOCATE ABOVE (E) GLB OPENING [TROUGH ROOF alrninanian (N) SKYLIGHT - EXHAUST NEGAITIVE AIR SYSTEM TORE tg ae y) SOND UIT HOUSING COL “MM@') Up THROUGH ROOF USING THE (N) SKYLIGHT OPENING & OPENING THROUGH ROOF FOR MEAT ROOM & GRAB & GO 22) USE (E) SKYLIGHT FO INTAKE TO NEGATIVE AIR SYSTEM A2.3 (3 \ CONDUIT HOUSING DETAIL (2.\ PLUMBING VENT DETAIL (1. \ RTU SUPPORT DETAIL COMPRESSOR LINES ps ee NO SCALE TO BE LOCATED IN FIELD BY ARCHITECT ~«#@(23)_ (N) CONDUIT HOUSING HOOD & OPENING THROUGH ROOF anne \a2.3/7 NO SCALE \a2.3/ NO SCALE \Q2.3/ AN REROUTEENDS FOR WALK-IN FREEZER & COOLER COMPRESSOR LINES a © TO BE LOCATED IN FIELD BY ARCHITECT PROVIDE SHOP DRAWINGS “4@{12) (N) TORCH DOWN ROOFING REMOVE (E) SCUPPER & DS I+ ~ fe OF T me ey + 37'-7 1/2" + 37'-7 1/2" (E) SKYLIGHTS BEYOND - NO WORK - - 4 - 4 - ( 6 ) ww <— e - {E) TORCH DOWN ROOFING OVER (E) RIGID INSULATION ON (E) T&G WOOD DECK (E) 2x 12 WOOD JOISTS @ 2'-0" O.C. w/ 2x 3 WOOD CROSS BRACING $525 1 A\\\ JAMES R WILLIAMS STATE OF WASHINGTON =) > 4 a. <q > 0 z ° - a. w 3) a Ww Q Ww be < ra} > iu 4 N Jo oo 2 4) og 9 xn OG L| oo o wo o Soo Pla 2 fee 2NO cm 2a0 of 0 <iq zo “~~ 0 Yio ine 214 aw 3 {7 mz JL, ¢22 YRS ga 5 n 2 4 x a = ) a ow oO o. | é | ? | | | | Z | is : | : eel —CD | (E) 8 x 24 GLB'S @ GRIDS #2, #3, #4, #6 & #7 CW) — ele! | a | (E) 10 x 48 GLB @ GRID #5 al = 3 lo (E) 6" @ STEEL POSTS ~ a : (E) CONC. SLAB a a | a | | | | | | | EXISTING CONDITIONS | | i ((1-\ BUILDING SECTIONS | | \a3.1/ Scale: 3/16" = 1'-0" | | | | vapn | | | | é | —_— | | 4 il + 20'-6" i i + 20'-8" i + 20'-8" i + 21'-0" i + 20'-6" i + 20'-10" i | | | | | | | | | | | | | | | | | | | (E) TORCH DOWN ROOFING | (E)2x12WOOD JOISTS @2-0"0.c. | OVER (E)RIGID INSULATION j w/ 2 x 3 WOOD CROSS BRACING | | | ; ON (E) T&G WOOD DECK ; / 5——— : 7 : | i | ! : : === : : : | : —— | “TT : | ! | | | L a a TS refexoecun (E) 8x 24 GLB Ji (E) 8 x 24 GLB Ji E) 10x 48 GLB | (E) 8x 24 GLB Ji (E) 8x 24 GLB J J | | | | ty | | 5 Bl | lel cw) | | | | | CE — me a fe : | | ! | | | - Hie | = = ; = = 5 a | | | | ; | | — a i | < i | (E) 6" @ STEEL POSTS - 7 : SN 7 | | | | (E) CONC. SLAB | | is PN. Le | | | | | | | | EXISTING CONDITIONS (2.\ BUILDING SECTIONS 3.1/ Scale: 3/16" = 1'-0" a 5 Cz Fe OO - = 2 oe Q a od O xe Le ij g Q x = “| b= |. FS YO | Z| = — 22k 5 S<a|&e O> ZO] wy 9 Ow = ria | $3i Ss Of | 591: - | dalle CONTRACTOR BID SET A3.1 Sheet # 6 of 25 sheets Job Number 20 GA. GALV. CAP FLASHING PAINT FINISH - MATCH (E) GALV. SHEET METAL SCREWS ARCHITECT PT SILL PLATE OVER SILL SEALER A PT OR CEDAR BEVEL SIDING wi NEOPRENE WASHERS @ 1'6" 0.C. \y . CONTINUOUS CLEAT LAL -@ & VV Re FREEZER WALL TORCH DOWN ROOFING ae 20 GA GALV EY BRRA EXTEND UP PARAPET, OVER TOP STATE OF WASHINGTON Ree 1'-0" x 5/8" B PAINTED MDO PLYWOOD & 2" DOWN FRONT OF MDO PLYWOOD METAL FLASHING enced TRIM w/ RABBET ] PAINT FINISH RR ANCHOR BOLTS | ws ey) @ 4-0" O.c. @ BOTTOM FOR SIDING (N) METAL SCUPPER & DS MATCH (E) i: 4 CONNECT TO (E) UNDERGROUND (2) #5 BARS RIGID INSULATION CANT 5 DRAIN LINES FOR DOWNSPOUTS a w/ 4" @ SOLID SCHED. 40 PVC 3.49.8 VROROAM YEE? CONTINUOUS SIMPSON ITT414 HANGERS a. FROM DOWNSPOUTS RIGID INSULATION PT 2x AROUND PERIMETER GEA IS w/ CEMENTITIOUS COATING at lo — FINISH GRADE BITUMINOUS DAMPPROOFING 4" CONC. SLAB w/ #4 BARS ned spacepaceranurennereyereys RR ; a (2) #5 BARS CONTINUOUS a oe: ad Be U Sossesccrstcsorococccrrnroecccretrerrocectentntee ek R-38 RIGID INSULATION 4" CONC. SLAB w/ #4 BARS “10 RIGID INS ON PED Mosesezscocoses EERO REREEEEE ET OOS 3/4" CDX PLYWOOD tetatatatatatatatatatatatatatatatct tect tite @ 1'-0" 0.C. EA WAY , [al —_ [nl TRUSSJOIST TJ L65 JOISTS @ 2-0" OC. — Fe © 00 OO CA 00 | OO | 2x12 WOOD LEDGER : =e phrenic Fila wi (3) 16 D NAILS @ EA. STUD —, SOW FELT. eae e ee WL w/ SOLID BLOCKING BELOW mY i Sy 2 ‘ Se ps h oo cosets f Soe . aon ae a es x 5 a : Bi cccsccevccese! ote Cr all = z rN oad, _— A TUAAEACHAGAATRCEEAEACR TENOR rover CREACRACASE aiecanthatie caataaeancaat themed ere (@) mem At ‘ secees Fa <>, CN er, = 6% 6 ie, isieeseisey.se: CW-6) =o ° S TS ., one : e ee va ee. a : ee ¥ nee ‘ooeme iS O.Oe. MX 6 MIL VB a : 5/8"MOISTURE RESISTANT ff pm z o ie ‘ * oe Pye ‘ Es ; yd . Sb # . seen es i \ TYPE a GWB wi VB PAINT ‘: a g rs rey a mn RRR 4" PEA GRAVEL ae | —_- (N) 20 GA METAL FLASHING © —_ eaves & = | < UP 6" BEHIND 30 # FELT co tease, | & OVER (V) TORCH DOWN oe 2 ryt A 6" CONC. FOUNDATION WALL 91% (N) PLYWOOD SHEATHING. —< accrue pe = | i e e ° —¢? — OF THICKNESS TO ALIGN nn? < Boe. sda, | CONC. FOOTING w/ F.O. (E) SHEATHING 2) L a 4 + 3/4" @ WASHED #2 BARS 7 OS. (3 \ DETAIL DEMO (E) METAL CAP FLASHING (E) TORCH DOWN ROOFING . DRAIN ROCK #5 BARS CONTINUOUS <a 3. Scale: 1 1/2" = 1'-0 iu ALTERNATE #2 4" @ SCHED 40 PERF. FON. \a3./ DEMO (E) SHINGLE SIDING m DRAIN - HOLES DOWN TO EXPOSE (E) SHEATHING CONNECT TO (E) / : 6° 6° 6° (N) 5/8" TYPE "X" MOISTURE of & —¢ ¢ r oe NOTE: PROVIDE SHOP DRAWINGS FOR ALL FLASHING DETAILS RESISTANT GWB w/ VB PAINT COLT <7 a ne Len i \ i , Vy ' > 1'-0 \ 1'-6 (E) WALL ROOF FRAMING, iy al i} (E) WOOD ROOF FRAMING, y 1 Oo (5 DETAIL (ay DETAIL INSULATION & SHEATHING Piaemeem| I\_ INSULATION & SHEATHING N rf " Wm at py i" ve at 4 4 i \ } : [ \ oO i \a3.2/ Scale: 1 1/2" = 1-0 \Q3.2/ Scale: 1 1/2" = 1'-0 (N) FRP PANELS & CAP TRIM | Z J > 5 and SET IN SEALANT @ PERIMETER on \ > , ene & @ "H" CHANNELS @ JOINTS (TYP) | Le (E) GWB oe ce FOR INFORMATION NOT SHOWN . Fi zag SEE 4/A3.2 8'-6" TO T.O. SLAB @ < 190 oi Lig Z oa ee pa ~ fi TAPERED R-38 RIGID INSULATION (2 DETAIL 3.4 uu 5 SLOPE TO DRAIN TO (N) SCUPPER Scaler 1 "= q{/“ mz i \A3.3/ PROVIDE SHOP DRAWINGS \Q3.2/ Cale: = ae a Jha < a 3 -¢—_1.0. WALL | | ! | (4 FOR INFORMATION NOT SHOWN | ) | Ax ms eas a} = | | : | A3.2 SEE 3/A3.2 & 4/A3.2 i = 2 0 7 a a J 3) 8 me | ! | g>" 3 a| &) = | S | | | o 2 = = 4 t :. <> 4 BS ‘ <é xx at 4 * > > x co x ee > na Ao a be > < om > Bs x > oe ” a3 | 8 o uw + S | ¢ +445 oe SESS eS ere: SSPE KOO ‘ sox oe oN ‘Shee ise es oe oe oe * Ses 0.66.45 @ % ! : oO N _ 4+ 9 : I | a w Eo I | 4 on l t mee | | | —@) + @ t corre ber <7 ot enpepmenreemeeny errr ree [ae a tien Roe oe roee ane ae = \a3.2/ CA. 0. 0F new) ! ! | T.O. JOISTS | | | | — eee — | | en a ne A cn i ttt ane i ie Nae een ee ah ein Sosa eo Note no nna i a sa nin fae i Si we if | | | AS AA | | " we w | | = pod an l | z pom wae | | O pod Wane Ps RI A | | < oe we | I = _ at RY cas | | = CW-6)—JKe. | RS ee | | : mag Ras ae \ | yf pe awa 4 > nN RR ay ee S| eee Lae = * RY ane < # Saw wae ad Pe] owe % 92 Pn! oe : Ra we W-3 S < eae ord ed Q. Tv Rene ae N o RR WALK - IN FREEZER wa b + SO = wae A & 2 © OY = ay FOIO UNA i O ro RR oN | af WY ng Pea] wae 2) Ww Oo. Re aA o| as Ed ae caer H oa Nas an <—_ Mu Q.. Se eS ~ O RA ae LL >< M| ee rw he s| 2 Ce os Ms w 22 Gl Se ws < | = ww NA Lu are RR ae YO of S : ae ae boone Y |e > i Per I LS || | n=: an ALIGN T. O. (N) SLAB = z [ ALIGN T. O. (N) SLAB mae : aA 0. < - © wi T.O. (E) SLAB Pre (4 we wi T. O. (E) SLAB Os> 2] pond wae | pe | A32 wae 6" RUBBER BASE r- Oo O| 2 T. O. FDN. WALL I PB | San < bt = o| 5 + | A] Sse | 13'-2" SLAB RECESS wwe mw ul . = 5 & ee i nl > i] er | : \ | T..O. SLAB ead Ox 2 |r s -—— | ee : a QO. = i = _ ‘ I 2 | an Tons anne i Dt a Dt a cael ] ] qa >> - o . : | ee 8s a Race $8 ee ihe ae Sete 3 : | ~ ¥ a * 3 Bo, ss ret : SER ee oe ee Sf Teo ae i fly Bs 3 = 2 a, 1 Se ; phatatats Clete > ook 3 fotattiatatatat ‘ Mae . S z ae ms lie igs eg te ie. Say ee See. a = oo OB EnEmy Meage et Em yey ORE et ee os — = T..0.. FOOTING puma fo { 8 : See bee ae: eee sieeeieesies: “ wy | “ - | : Es I ‘a | ; con ie Ae | eas B. O. FOOTING 4 ! Tes | + 1'-3 A3.2 r 4 | | eS SECTION on iS t w n nw H 3 2 Sca le: 3/ ° = 1 '-0 ” £ et I 7 1'-0 8" | 6" | 6 | 8 + 1-6 i a pS , a (N) WORK ® ___(E) STRUCTURE sins | | I 1'-B" J ® Nu en Sp, eo _ __/ 20 GA. GALV. CAP FLASHING PAINT FINISH - MATCH (E) PT OR CEDAR BEVEL SIDING CONTINUOUS CLEAT PAINTED MDO PLYWOOD TRIM wi RABBET @ BOTTOM FOR SIDING CW-6) GALV. SHEET METAL SCREWS wi NEOPRENE WASHERS @ 1'6" O.C. TORCH DOWN ROOFING EXTEND UP PARAPET, OVER TOP & 2" DOWN FRONT OF MDO PLYWOOD RIGID INSULATION CANT 3/4" CDX PLYWOOD ZN ers esate! Soe *, + eels SR on RSS R-38 RIGID INSULATION 3/4" CDX PLYWOOD TRUSSJOIST L65 JOISTS @ 2'-0" O.C. wi SIMPSON ITT 311.88 HANGERS @ EA END 2x12 WOOD LEDGER wi (3) 1/4" @ x 4" LONG LAG SCREWS @ CENTER OF EA. STUD SAA Aace re aera reas: 5/8" MOISTURE RESISTANT TYPE "X" GWB wi VB PAINT (4~ DETAIL \Q3.7/ Scale: 1 1/2" = 1'-0" NOTE: PROVIDE SHOP DRAWINGS FOR ALL FLASHING DETAILS (3 \ DETAIL \Q3.3/ Scale: 1 1/2" = 1'-0" FOR INFORMATION NOT SHOWN SEE 2/A3.3 & 4/A3.3 LIFT (E) CAP FLASHING & EXTEND (N) ROOFING TO T.O. WALL RESECURE FLASHING 2x12 WOOD LEDGER wi (2) 5/8" @ EXP. BOLTS SPACED 8" 0.C. CENTERED ON EA. JOIST (E) TORCH DOWN ROOFING {E) RIGID. INSULATION (E) WOOD ROOF FRAMING ey AL. XK RECTION RE Queen OA NLL Be ppsioo Baits Tee Cha ox. 2 4° (E) CMU BOND BEAM (ASSUMED) (V) SOLID CONC FILLED BOND BEAM 7 | — Vlei ((2.\_DETAIL \Q3.3/ Scale: 1 1/2” = 1'-0" NOTE: PROVIDE SHOP DRAWINGS FOR ALL FLASHING DETAILS FOR INFORMATION NOT SHOWN SEE 4/A3.3 (N) WORK { Jl | ~ | { | | T.O. WALL | fay | ' ~~ > a) Sf | A3.3 | I x; @& ! | Se) | O eee < | | | S| <<) = 1 | =I | 2) * l SOT SLITSTATITeT STONES i: vt > & { *¢ “se F | ~w = ~ = = x Pad F x os + ran) - I 1 = a 7 = = “o NN 2 ~ 4 = 1 | \ | to | | | { hal ? ¢ * x a . - esa = = A I ( ] ‘Sheen sine ones iene. seine ities J ene ann ons seen eit } 4 T.0. JOISTS ; < * SS” ey 2 Ss ms sy oii a8 — vy - rs —<— ee ey” a . — ws 40m oo ge a we m) o x6 8 — gs gi i a — PAPI III DODD GP PG PPPOE PDD G DGG POPE OSSD OSSD PSD G EIDE SDD E SGI CES P POP DCD PDL O SPSL EG GE DEG SEDI G LOG IOR Pg NE sgt GN ENE REN NCE Ent cE A NCEN NC ESTEE CECE PGE NNN LAS NE ENS LL PRE GENEL op OLSEN SG cl ENE GOO gO PNG NS A gl GENS SERENE ESE aN EERE ESS PAGER LEE EEG RRO RRO RR RRR arene ng nn ato ra ta ena ned na gd ecg el dNene A d nned NSPAAE PPE AAAAALAAAAAECAAE EAA EAEAEEEEEAALAEAEALAA EP PSALPEEEA BRASS pues sa 4 ped jaw ae Rew want ead Ree awa Ce wae oN Sans 2 was wa poe =e one Ce aes oo RS ae ao 1 RS aS paca ons oll wae rd Se a = wae pom mo PO a Pe "ea © ax ed BY RS RR 3) CW-6)—F-* RA [SA ll pane eas ae ita “ ae ore ae << Sg oa oe Ss Pe pre oon e ae RA ESR ES RA Ra RA = Sa a aos = “ oa te Ry i wae cme Pad =< v RY RA RA as Cet = Re ma nn nn | bee #)& Se a RA oO ai woe nd Pen] we oO RA eee Lee] = = soy, Sane Par = 4 ne ee arn & {IP wae tiny penn ny oy re on 7 SAS Sew ae Qi ay Ne pen 4 Cane ed fh RRS Pes aos Bw WALK-IN COOLER RR WALK - IN FREEZER RA wae awe aes wy FOIO AA FOIO A pas wa pace wa a aR was eae poe wae ae Prd Se fo aA RAY Ra RA Sone ped en ay ay Lod aay oe aon Pn eae nse Sone fue poe <_ : we Me fA wae Swe ean aoe See pes eRe ed Gate wa owe tates eats Pad aa POONA Pee Bee RS ae PSA ee ‘ ae one ALIGN T.0.(N)SLAB Ewes pd Geant PN oe aA w/ T. O. (E) SLAB ae wae oN Ces | Ree nA wea eae Sas I | T.O. FON. WALL wae ome lon Lown 3 pa rete 8’-8" SLAB RECESS pend 5 Po mana : ray ns x oe) pe ae pasted *» ; _T.O. SLAB aw noe es & am 0 see a ns ns ns en ee te —— _-—- —- es Se ne si aaa aca iia sana sac aaa es ae ms ene ee ae en a em Sp —— a peace aii — —— aaa ; r a ‘a > = Sh peas tte . SM = eS 4 x 3 <P : | Ww —s on . aay os, : eS * 3 tetetah S30 eh eS : | a5. e, Seo se ; ROS ‘3 ay ‘Y uy x > = se “yecl 66 * thw : . Ks os os, bs <0 } — > £ ‘4 Sas ee — * . * % a4 = > a . wy S z Ke) a a a a a ee Se eh ee ional : s ; = EE =P zs . e -—_ _O. FOOTING eo) = 4e8 Seeceesee T.O. FOO ru bo foo ‘ a ad cx” rx ¥xXX rx > & KY o — on a : tL 4 oe (1.\ SECTION I ” TF as ' " ] \Q3.3/ Scale: 3/4" = 1-0 I + 1 er ’ SEE A3.2 FOR INFORMATION NOT SHOWN $525 | Z\\\\ aA JAMES R WILLIAMS STATE OF WASHINGTON AM E S J Q > ro a. < > m =z ° — a fw 3) qn Ww Q Ww » Q | lu re fh Oo] f p ¢ J» 2 a. o 8 a oO L| oo o -~< i oo hee EE INQ f| zae 3M ree of Xig 295 Sle aes gio az 3 3). 02 Si gr2 © 2a5 no { 1S ria} li QO a Da t e AP R I L 11 , 20 1 1 Ap p r o v e d by JI M WI L L I A M S PO R T TO W N S E N D FO Q D CO - O P RE N O V A T I O N & EX P A N S I O N WA L L SE C T I O N S & DE T A I L S Dr a w n by JI M WI L L I A M S CONTRACTOR BID SET A3.3 Sheet # 8 of 25 sheets Job Number (E) 8" CMU WALL fee ASSUMED (E) CMU BOND BEAM (V) \ i hi Ns (N) 7 3/4" HM DOOR FRAME aK 2 HOUR ASSEMBLY (N) DOOR FRAME 2 HOUR ASSEMBLY 7 (4 DOOR HEAD \a3.4/ 3/4" = 1-0" + 4'-8" (N) MO TS i = S i <|iL gh eae < ee GN Fa i (E) 8" CMU WALL / ‘ (N) CMU BOND BEAM BLOCKS ‘ FILL SOLID w/ CONC. ‘ (N) #5 BARS (N) 7 3/4" HM DOOR, FRAME :s & ANCHORS ‘ /5 \ DOOR JAMB \Q3.4/ 3/4" = 1'-0" DEMO TOP COURSE OF (N) HM DOOR & FRAME (E) CMU FDN. WALLS @ (N) DOOR OPENINGS TO ACCOMMODATE (N) SLAB (E) CONC. SLAB (E) CONC. FON. WALL SEE A/3.2 Ke | (E) CONC. FTG. /6 \ DOOR SILL wee a8 CW-8 DBL 2x6 WOOD HEADER HM DOOR FRAME & STOP 1/8" TEMPERED GLAZING (14\ WINDOW HEAD \a3.4/7 3/4" = 1-0" CW-8 > 2x4 WOOD KING STUD 2x4 WOOD JACK STUD /15\ WINDOW JAMB \a3.4/ 3/4" = 1'-0" /16\ WINDOW SILL \Q3.4/ 3/4” = 1'-0" ¥ _ 1 ‘.Q" CW-8 > DBL 2 x 6 WOOD HEADER (N) HM DOOR FRAME | ad SC PLAM DOOR /12\\ DOOR HEAD \a3.4/ 3/4" = 1'-0” 2x4 WOOD KING STUD 2x4 WOOD JACK STUD /13\, DOOR JAMB ag) a= 1-0" $525 | ARCHITEGT. JAMES R WILLIAMS STATE OF WASHINGTON x & AM E S -, Q > led a <{ > a z ° - o. om © ” Ww ra ww = < a > tf ea 2 3) 0 a ¢ . Y oo N oO 4 an 0 “| Bk -~ o Soo Pla ae Li oo E| zee pi zee of Lig 23h 7 Sms PE < ozd “ -Os 3} $22 ya 5 a <{ 5 6S ow o o. DRILL & EPOXY ACRYLIC OUTER DOME #5 BARS INTO ACRYLIC INNER DOME (E) CMU BOND BEAM FOAM TAPE \ VHB TAPE \ \ \ SILICONE SEAL BEAD EXTRUDED ALUMINUM EXTRUDED ALUMINUM INNER FRAME w/ INTERNAL ASSUMED (E) BOND BEAM (V) COVER CONDENSATE CONTROL GUTTER THERMAL BARRIER = eo ASSEMBLY SCREWS SEALANT BED a. ‘, <p) l FASTENER ion | TORCH DOWN ROOFING —_ WON <— 2" RIGID INSUL. CANT é re \ 3 1/2” RIGID INSUL. CANT % l| ie | RIGID INSUL. <4 . Ht \ ieee | i NS “A SESS 2x 12 P.T. WOOD CURB ~ . _ seateneeeie | | Soee%e ‘ \, i See > | % | Se é H ‘Ss 5 ad Be SZ ’ | \ | 5 Seceen Q \ Aas 3/4" CDX PLYWOOD x x =| (N) #5 BARS Sl MS z 1 7 i — <n = \ — ‘ yf | ROOF JOISTS - SEE A4.3 _ \ | v | x ‘ + y / | —_ F / ‘ —_ ~ ROOF JOISTS - SEE A4.3 I 7 I | 7 ; 2 x 12 WOOD FRAMING . [ ra | <— BETWEEN JOISTS —_ y N | yg | 5/8" TYPE X GWB I S | : / / | i Nn : + i } ‘ AL»? Speck ar Lnopenktsmt e& | DRILL & EPOXY #5 BARS INTO - (E) CONC FOUNDATION _4 # 4'-8" (N) MO (2 SKTLIGHT DETAIL (1 \ SKTLIGHT DETAIL \Q3.4/ Scale: 3" = 1'-0 \a3.4/ Scale: 3" = 1'-0 (3 DOOR ELEVATION FOR INFORMATION NOT SHOWN \a3.4/ 3/4" = 1'-0 SEE 2/A3.4 DOOR | DOOR | DOOR DOOR FRAME | HEAD JAMB SILL [HARDWARE NUMBER | widDTH | HEIGHT [THICKNESS] TYPE lateriat| CLAZING | LABEL |uaterRiAL| DETAIL | DETAIL | DETAIL | SET REMARKS ALTERNATE #1 108 3/0" 6'-8" 4 3/4" B WD NO NO wD Ch (am #4 RELOCATE 109 DOOR & FRAME, REUSE (E) HINGES, aag/ | \a3.g/ (N) TRIM, CLOSER, PUSH-PULL HDWR. & KICK PLATE ALTERNATE #1 109 3'-0" 6'-8" 1 3/4" B wD NO NO WD &) GD #1 RELOCATE 108 DOOR & FRAME, REUSE (E) HINGES, CW-8> CW) : (N) TRIM, CLOSER, PUSH-PULL HDWR. & KICK PLATE BEL 3x 4g WOOD HEADER DBL 2 x 12 WOOD HEADER 123 supe 6'-8" 4 3/4" A HM NO 11/2 HR HM ee ey on #2 (N) WD. TRIM - MATCH (E) ig _ an ; ALUM. ALUM. PROVIDED & INSTALLED BY KITCHEN EQUIPMENT : 124 3'-0 6'-8 +3 NO NO RELOCATE i 1 HM DOOR FRAME INSUL. INSUL. CONTRACTOR (E) WD. DOOR FRAME 11/2 HR ASSEMBLY 425 31-0" 6-8" +3" ee NO NO hy PROUDED S: INSTALLED BY KITCHEN EQUIPMENT RELOCATE HM DOOR : (E) WD. DOOR pe ad i aeeeeey 126 3'-0" 7'-0" 13/4" B HM NO 2HR HM > (a) Ges #3 4° TALL FRAME HEAD PR sc (12\ (13 DOORS & HDWR. PROVIDED & INSTALLED BY KITCHEN 127 vr 6-8" 1 3/8" Cc SAFETY NO HM (10\ DOOR HEAD (7 DOOR HEAD 1'-6 LAM ay a4 EQUIPMENT CONTRACTOR. FRAME BY CONTRACTOR ea.4/ 3/4" = 1'-0 \a3.4/ 3/4" = 1-0 436 ape gust - ati No HG ALUM. PROVIDED & INSTALLED BY KITCHEN EQUIPMENT ALL OTHER (E) DOORS ARE TO REMAIN UNCHANGED WINDOW | FRAME | FRAME FRAME | HEAD JAMB SILL 2 x 4 WOOD KING STUD 2x 6 WOOD KING STUD \ NUMBER | WIDTH | HEIGHT NPS GLAZING | LABEL MATERIAL] DETAIL | DETAIL | DETAIL REMARKS 2 x 4 WOOD JACK STUD 2x 6 WOOD JACK STUD (14\ (15 (15 1 3'-0" 6'-8" A TEMPERED NO HM (A1\_ DOOR JAMB (8 \ DOOR JAMB HARDWARE SETS 3.4) 3/4" = 1'-0" 3.4) 3/4" = 1-0" | { ey ey : 4 4 #1 REUSE (E) BUTTS ONE (N) PUSH PLATE : ONE (N) PULL WITH PLATE (N) HM DOOR & FRAME , , ONE (N) CLOSER DEMO TOP COURSE OF &o 60 60 0 ONE (N) KICK PLATE (E) CMU FDN. WALLS © © to , ? © \ ONE (N) WALL STOP FO ACCOMMODATE (N) SLAB *s ad i =, OT ' | #2 11/2 (N) PAIR BUTTS (E) CONC. SLAB ee a ee a ° 7 T T ONE (N) LOCKING HANDSET \ ie oor 3'.0" 3'-0" 3-9" 3'.9" ONE (N) FLOOR STOP (E) CONC. FDN. WALL | P| ~ x ae ——— a ae aaa -eeememetiiiien sites aah en ai ONE (N) SMOKE SEAL SET Re a DOOR TYPE A DOOR TYPE B DOOR TYPE C DOOR TYPE D #3 11/2 (N) PAIR BUTTS (E) CONC. FTG. i SEE A/3.2 HM DOOR & FRAME HM DOOR & FRAME SC PLAM DOOR WD DOOR & FRAME ONE (N) LOCKING HANDSET wi 4" FRAME HEAD & HM FRAME ONE (N) KICK PLATE ONE (N) WALL STOP (9 \ DOOR SILL \a3.4/ 3/4" = 1'-0" 3 1/ 2 " (V v ) + 3' - : | | (Vv) + 4 ee i A, A WINDOW TYPE A HM FRAME TEMPERED GLAZING ONE (N) FOOT HOLD OPEN ONE (N) SMOKE SEAL SET oO. = Pz = O° "i = 2 a Q at ox Ox Le i g OQ < ze 5 Le zs WY © 5s Ze $5 a oO> o a ®) wo| = rE Zz =| Ss oc WwW <] a on. iu |; = QO. Oj; = CONTRACTOR BID SET A3.4 Sheet # 9 of 25 sheets dob Number 11 P , i Plas, Daainis «/Trae FRimers “ “ f \ f n " t a LT é 4'-5 1/2 ‘ £12'-7 4/ 4 Teg OVe See Wil. LA | 1' 3° + ha 44" Za. \ “ 4 X% : @) 4 Cw + AGL G=——— oe ry) Cwr) o|-@ \ Y \ w <7 4 RSTO AE i T ae Toi | TT 7 Mi heuabhas | co oo eo 4 z Seaesdeneasen an | [bessqagane-ee-=--4 z| fs . Reha oS _ . Seeaeecen Tr = g ‘ a as cipreepceicss 248 a ro PPR = <= id ; | be dak ig bP ddd an h nsdn dowubin ond tiBidd eto TTR BS nt dt ecbalbent rad triad Suh nme ea ol on nl i co w Ld i oe Le! 1 = tau ye nen re HEN mae ° Ss a2 BN? TAO. 7] 7 saeens ° = 8 stier peepepeefe ! re \ it a et < | Neo. j “ : : = ins ieado i | : ENP y) 7 4 . a: 1-10" MANEUVERING — \ 4% q A) . S ay 7 Oo Yt ELERETS| Necesssir Grorites, [pp 8 Peed it Ne NS 8h Ww | 5 i ' i U a f ¥ SS Song ea oe ed - oa ee . reer cy A _ Ree 2409 SAIS) LITA | ee T z oe iitess ; “aa tl : | Messy a fpacaig Sec, Pat-\ & wah og Bogan Se SON (a 5 bye wad i A assnae _ Bariaisas i oh a | a em “ ! > -e r a ee ~@e- foraet ora Ee 2-6" Lees , 4'-3" = ‘ + i i mea a 2 co | C : _ , ™ ‘3 : : <I t 4 +H | x : ws 3109.1 2 Joocees aoc aavm |sueeeea@eanees! GRE Pe e i = > Becdetesbe sr os : el 2) 5 3-6" MANEUVERING 3 - (SEC || Lh gr ot oa a l 2 | SLEEP | ~ . : i “TS i { iF Keeo Mpa oAReA | ao elon 1 = eer SE CULE CI wa Sh | meni i AA eDY ERIN RA | | 4-6" MANEUVERING mh #4 fi cane) dneunaaae ia Cy Gee 7 VA Cheng 6E Vermanaet CBSTRYCTIONS De LL caudal ene ij \ Ue he hem eae 5, > $------------------- =o -—_—<t + -u ee ae \; — & i _— | 5 - Hlo-\ el ary ee : La comm ea _ i yy | S : i dt econ ee af : N 2 3 re ) ie ot NK : ps EP yy | we) gtk <q{:) + C ) aa e Sica | c ) » Pe oy Fey Bees: oe 4 H : Op yas | ; —h | 1'-3" 3/4" | t 2'-8 7/8" (V) 3/4" | 2'-B 7/8" (V) 3/4" tet 5-0" i sae —_—— op eon — : ; ~ : ! i | H | Q HAE Ha E L sea : i = RETEST rpeeeet i a) é 4 i : | vas : i y oN : : Fé a y E > each 1 (109) phossansN - 4d ! ‘ cate a le se) iene j i Pula i ea Lee a ye ee NY I N 4 i a i i : j a 4 P | smote ca cence oo | : DOOR = sll = is oe) k Cy \e! mabeae 76 | | i cece ig H |$—] > eee era Tiee aa trea eipnat e EGE as ine 2) sap Sst ccoueocaatetted it ity | Upbgpie rrr rieys] eehebt phe) epee af te an meG@n ad be sacs aioe Li NE C Ee eee ab eae oa preenes ge one oft e re nN — . <a a a : ree Ape Bl eeeee Se ee : BINS ~ atapas | i + | | PEELE ELEY : 4 N } : r i oe / 2 “= L Bee oon sree 2 | 2X. Recloubastexbeys i Bad 7 t : {:) hiecd Seeall fh MAY - “Al ‘y 4 = ‘ — . | e | ba | ~ \ \ I? ——T —; —_— cc \ (s) , \ —C w-9 ) ; EXISTING CONDITIONS / DEMOLITION PLAN FLAG NOTES $2.6" 41-3" 43" NEW TILE FLOORING “a@({)) DEMOLISH PORTION OF EXISTING WALL -«@(7) REMOVE (E) CABINET DELIVER TO OWNER MATCH EXISTING —a@(2) REMOVE (E) WINDOW —a@{8) REMOVE (E) DIAPER CHANGING STATION FOR REUSE I> EXISTING CONDITIONS / ) NEW WORK FLOOR PLAN ven Coen TRACTER 4 DEMOLITION FLOOR PLAN ~aa(3) REMOVE (E) DOOR & FRAME FOR REUSE (9) (€) SHELF TO REMAIN Scaler d/o" = 1°20" Scale: 1/2" = 1'-0" was) (E) WC & GRAB BARS TO REMAIN (E) CERAMIC TILE FLOORING TO REMAIN CREOK PL MOUNTING L&cAtL Als : CT P RUE PRGIEOT a(S) REMOVE (E) LAVATORY FOR REUSE DEMOLISH PARTIAL TILES WHERE WALLS ARE DEMOLISHED TEE PRGIEG [re ATTACHED 260% AAKL UTA ~a@{6) REMOVE (E) CABINET FOR REUSE “W{11) (€) STRUCTURE TO REMAIN = Vans DHStacatism. pt nono E fo) © om) I 1 I “te <® : = e I \ Ye . ai | ; <i) ; ° OPEN . * ee i s [ cummeraare | cD * 4 ye) es ie PREP R E T E Cura wee Owe. r d | | A ———3 a wile | i. tad ee a a a ff \ / o ia \ i phe pee aire ea: F —_—Yhy 7 lL» eee Pe tee aan Pa ae / aan |} 7,” | Ons PARI SAG EN \ RNAI RRS / <q7) i. ad . LE eee eee ee ee of fF FFA FF FER FM FS Fe FP FF A Ww B2° cle Cpulng, FA oF 4 # reer e ale ‘J DEN CALE ALE | (E) WALL & BASE | (N) WALL & BASE | (E) WALL & BASE (N) WALL & BASE | REMOVE (E) WIN. (N) WALL & BASE | (N) WALL & BASE | OAL - REPAIR | (N) WALL, PLAM & BASE | ? t ADD FRAMING, rt a. SHEATHING, INSUL, y oN yw (N) WALL, PLAM WAINSCOT & BASE yn a 2/A9.1 & SHINGLE SIDING 4/A9.1 5/A9.4 » 6/A9.4 >— Oo, a>— © a ) . ~2 L i * PS - q Ly —_ 4 <= . (5 -e * i * a in x = 5 2 P ; ewan DCAD arr ae <0) CARH AA NUNN A cc ay U a Uf =| . | aad Ty T Wma Donooee NNN wT ] 7 % ‘ “ — eS 9 ¢ rae Nate eee es Pe ae ha ae ar hoe ee — < & * t F u > t GNA me nO <) POLO, CARRS Fen NRG RARRA ee: a a -? : preety” Se Par hPa a a ee ee ae iL VW 2 AEE ee ee ee P ar 3 ra oO \ a et EN Sy hom 8 ane m8 ae See. % e: SN ae is | ‘ ° °. - - at (E) WALL - REPAINT N) WALL. PLAM & BASE (E) WALL - REPAINT | (E) WALL - REPAINT ¢-to"| 2-8" Jett) 3-2 3/4" (v - E) WALL - REPAINT - (E) PLAM-(N) BASE | (N) WALL, PLAM & BASE ; - (N) WALL, PLAM & BASE —_(E) PLAM WAINSCOT - (N) BASE 4 { 30) } ‘ (E) PLAM - (N) BASE | t ) (e) W) { ) l jt ) \ (N) WALL, PLAM WAINSCOT WAINS RIAN: (N) BASE) , t , Ma, y N y » <i) B/A9.1 9/A9.1 10/A9.1 11/A9.1 y N 12/A9.1 INTERIOR ELEVATION FLAG NOTES ra (5) REINSTALL (E) WALL CABINET (N) 5/8" TYPE "X" GWB IN (N) AREAS | ~<a) (E) WC, GRAB BARS, TP DISPENSER, (10) REINSTALL (E) BABY CHANGING STATION PATCH & REPAIR GWB CEILINGS IN(E) AREAS 7 . de! 9 —_lo o> ° SEAT COVER DISPENSER & WALL DISPLAY -_ ALL CEILINGS TO RECEIVE (N) PAINT po . a2) (©) ACCESS PANEL @{i1) (N) WC, GRAB BARS, TP DISPENSER, FRAME (N) CEILINGS w 2x6 WD JOISTS @ 1'-0" 0.C. = == OD a SEAT COVER DISPENSER & WALL DISPLAY ALL WO RK SHOWN ON THIS SHEET al a =. area ; 0 am: iat DEMO & REPLACE PORTION OF (E) CONC. FLOOR | ° i cer bh i = (3) (E) ACCESS PANEL TO BE REMOVED ~a@{i2)_(N) LAV, MIRROR & SOAP DISPENSER SLAB AS NECESSARY TO MAKE DRAIN CONNECTIONS | | I / he Bes Me tH ~aa(+) (€) SHELF TO REMAIN (18) (N) URINAL 4" CONC. SLAB SLAB w/ #4 BARS @ 1'-0" 0.C. EA. WAY | S Pp ART OF ALTE RN ATE #1 Ye NS gy d OVER 6 MIL VB, & MIN. 4" PEA GRAVEL call # 7 7] <5) (E) ELECTRIC BASEBOARD HEATER <4) (N) ELECTRIC HAND DRYER TIE (N) SLAB TO (E) w/ 1'-6" #4 BARS @ 1'-6" 0.C. / J oe | 6) (E) WINDOW & FRAME - REPAINT 15) (N) TOILET PARTITIONS DRILL & EPOXY BARS 6" INTO (E) SLAB i / (E) WALL - REPAINT l + 4'-7 3/4" isl 2'-8" | | 5" (E) WALL - REPAINT <7) epics anantes ee ee (N) WALL DISPLAY OU WALL, PLAM WAINSEOT S BASE (E) FRP - (N) BASE (E) PLAM “(NV BASE ~ —w4(i7) USE BULL NOSE TILE @ EXPOSED EDGES —_ NOTE: (N) PLAM WAINSCOT & TRIM TO MATCH (E) * ¢ a * ¢ <@@{5) REINSTALL (E) LAV, MIRROR & SOAP DISPENSER a 43/A9.1 14/A9.1 15/A9.1 “Ver 2009 GPc , See YD Fleets Te Be Stato TS Frag Oras A\\\ ABA. JAMES R WILLIAMS STATE OF WASHINGTON 2) S a a. < > m =z Q ~ o rd O ” Wi ra} Ww — < oO > uu ra 2 a} J oo 2 N O 4 x L} oo o ~< o Soo J E258 Sb +e) ¢, 2a- @ 202 Y) 39 34 uw 3 ¢ oz- She «92 Waly oa 5 a 2 4 7S oO WW QO a Qo. — Gz : O° " ~ D a o =< a Ox aS : re) = a = WZ | 220s Ze | se) 2 =a | «s O> /| 82 - te| & 2 | S| Q = Pig | del Ss Oo | <EL, = a ifs a8 [§ 5 CONTRACTOR BID SET A4.1 Steet # 1Qof 25 sheets Job Number LAN a +3" , #3-4"-(N)MO_ 43 $525 { \ \ \ \, ARCHITEGT Wo. <_< JAMES R WILLIAMS ’ STATE OF WASHINGTON | | aa ey l > ( \ (- \ | {f\ ™ 1 a s i pA } \ pA po } > FS dg; ~~ = _ E15 FS _| a a ED | ~~ EE on €13 | EP || €D ED) XE) < ri ‘ 4 ‘ ( \ _ ( A fs, V2 WS A - YF KY XS pe ee spree oem Siegen =. soeevem a " ; Lt m sans a TEMPORARY DUST BARRIER E11 E11 1 i i {Ev (ET) z E27 ey o. (E28 fo TN He ; i | a (Eb9) | | (E6) 7 (E6) | -——— a uu (2) E16) | €26) E7® a esis fos, | | ‘ O E20 i, | acs! Nena N > (E) FD = (E) FD ee EN 7 ty E26 r E26 Y Pa (E20) / sont toantetbVosbs dealer nitobebobie ! (E28) -, (E22) / BS) E21 + ze E17) GREASE TRAP ; . (E) GREASE TRAP f R LL I A M S AR C H I T E C T US G E C PH O N E 36 0 - 7 3 3 - 2 5 8 1 EM A I L - uJ I M W I L L I A M S 1 5@ C O M C A S T . C O M 7 AM E S VW . PO BO X 30 2 6 4 , BE L L I N G H A M , WA 98 2 2 6 - 4 3 7 7 . i | oo | E31 y 7 : . i (E4) (E2) (E4) (E2) \ . | et_k 7 ee E18 re a] —+ RN REEEEERESARNERNAR is ‘g ' S er a wa N56 ‘ bea Se wee ¥ i é ¥ + . a x ed Teas a i Zz —_ (N53) Ss a A4/A4.2 i i te a y N N ' s cA a = z a | i Nei) 5 ™s ° ~ aan | Lu = 7 2/A4.2 i i ' ~ ee | an = NS ‘ y r z = Fa ram x \ r aa : | 6 J DEMO PORTION OF (E) WALL ABOVE ~ \ Lo iu alin r--222-27-0-—7—70 ¥ — : se — PATCH WALL AFTER / ; / rm ale DEMOLITION - MATCH (E) ia : Cy ui} + / 8 ) , ® Iz = eee eee | = ee 7 = ee wa pee IIRL = ud | Oo -@ Sa 2 ann cr | Sovereene eeereterere seer sete eee LJ i Ww s — ——& a a O at VA EXISTING CONDITIONS / My oe LEDGERY _ NEW WORK FLOOR PLAN TEMPORARY DUST BARRIER DEMOLITION FLOOR PLAN A ler HANGERS Scale: 1/2" = 1'-0" | QO. 3 8 Own az Scale: 1/2" = 1'-0" @ EA. (E) JOIST A BASE BID - REMOVE CARPET & MASTIC TO EXPOSE CONCRETE FLOOR & SEAL CONCRETE Li. < wn TRUE PROJECT (E) STRUCTURE TRUE PROJECT LTERNATE #4 - GRIND & SEAL CONCRETE FLOOR LU = NORTH NORTH DEMO (E) LOFT NORTH NORTH (E) WOOD FRAMING = s STRUCTURE (E) WOOD FRAMING i < 2 = | - a : 1, _—|-+ wz | 23h 7 [| 1 = I I I f aE 22 | 3202 / za — oa G a) xr> on <x | SS) SESS SOS SELLE LLGS. | 1 \ | or on a ; =I —_——o ONELAGIIG FO | ce} g . Nd -----F a } < 4 INTERIOR ELEVATION FLAG NOTES 2 | a6 oe ari ale ve = ye eee ee 5 = 24 Pye ¥a z > ex a AP SP et ras eu x teat Maite _~ a xy oe ee y a, aM Hes i. Y = ARIS AARRAIS © nn | RO A <} Se] iB A WARIO RIGGS | tO) eels BRINGS cece ce ak: CREM EIE NT <2) <q) FRP TOP cap oc uw we, >» eee mn o—wS) (2) eee E G| a] = ; NN Onin nn | a3 ) @) @)s Ms y Patents w/ SEALANT BEHIND & INSIDE oc <ie| = ee! “S 5 CNC Ore Uae Ms 7 4 : = - 4 ats Ui Or hearer a lel i af Peat ke 5 Fy ACs ‘, . > Fe. oF v4 a AN st = ¥ BF Og FEE ETE aS nN st o WW 7 ae Pal Os al FRP "H" CHANNEL G Lu = 1§ = ta a a ¢ ¢ a ae a’ | Sa] et & ° Cae ee: <<“) ~ i ol o+ YQ - te re > zs < enn OD [hes Oa CARRION RAN 3 eo a DRAIN Nialel SAL D I Rains ) WiseALANTa INSIDE QO |6 5 eet? oe ra e PP etal < t.? S 4H = on 2 ia 4% 7. Pag es sf ooh all +H =a ra ay <4 7a srg £ a4 FRP OUTS A J “ iN RP a cet e wp uk a s NEAR COG eee - 9 ne < ae s* SN i —_ ~<q;) w/ SEALANT A eee TRIM Ae | MC | Aas PARRA P #| 9 ; BSS SSS *)o) St SS on) i CONTRACTOR Ww RNA WAAnnnen ; 8 ; OAR 6) By | Panne RIAA —) WscaunTainsiog BID SET Cane NINN SRI é b p ER NSN SNS a 3 S (5) ie nimlaie | pane Bent Se oe ne ; a . 3 8 ieee CR RCIEE -| § a aq) FRP EDGE TRIM ook foe Oe Ce a a ea Peer re a ~ Z a PRCrrLes CAC MT) L w/ SEALANT & INSIDE , "4 (N) GWB CEILING REPAIR (E) WALL TT l "REPAIR (E) WALL TTT —e— <5) (N) 1/4" MOISTURE RESISTANT GWB A4.2 DEMO & REBUILD PORTION OF (E) WALL (N) WALL FRP (N) EPOXY PAINT (N) COOLER (N) EPOXY PAINT (N) WALL FRP DEMO & REBUILD PORTION OF (E) WALL OVER (E) GWB - EPOXY PAINT FINISH Sheet # 1101 25 sheets NEW WALL FRP - (N) BASE - MATCH (E) N) BASE - MATCH (E (N) COOLER REPAIR (E) WALL (N) EPOXY PAIN (N) COOLER (N) BASE - MATCH (E) (N) WALL FRP - (N) BASE - MATCH (E) ~ a ( ) ( ¢ ‘ é rs — — Job Number 1/A4.2 2/A4.2 3/A4.2 41A4.2 5/A4.2 (N) THROUGH WALL SCUPPER & D.S. - MATCH (E) 2'-0” (N) METAL ; CAP FLASHING 3.1 a + 8-1 7" 24'-0" \ INC ) > ‘ Lorn Q Fe) 6 1/2" JAMES R WILLIAMS VALLEY = = PROVIDE TEMPORARY DOOR FOR CONTRACTOR ACCESS STATE OF WASHINGTON | SLOPE a a ih REMOVE DOOR AND FILL IN OPENING AFTER REMOVING (1N “Down a z 3. DOOR & MATCH ADJACENT WALL FINISHES \A3.3 a! |: 6 vi 3) = Qa uu. aie’ Mera See ey neTa ze : y CAP FLASHING 4 CAP FLASHING _ Oo; |° a. . LL ui. < SLOPE ee | ee ee rene ~ DOWN “ | = F.O. (N) PLY. = , (N) TORCH / (00 whe Analy IS SEES ro ONE 9 DOWN ROOFING 3 \ A | Ni a Q 3, , SLOPE 3 A | Ny a; © DOWN i |! (im) I eB Nod Noa) = = 7 a ¢@ i al | | <| a | iil x 3. I y NN LB | (E) TORCH ety Dae em se sr eo ee ae JA3.4 DOWN ROOFING Kien. hea, “i “Neng Manes COOLER (E) CMU PILASTER BELOW . Qoeeesteo” Perm ~ O10 3" AIR SPACE > URe Sec YAI\,\ (Fen Beth cahers 4" PANEL 2 ; a. % N — et. + 6'-6 1/2" 4" PANEL = 16-0" a ‘mal = Lo 4 7 D ie x &@ Ww \ (E) METAL f (E) TORCH \ (E) THROUGH WALL SCUPPER Ds a <_ CAP FLASHING DOWN ROOFING & D.S. - MODIFY D.S. <— ae = y CIE) Escage Latcdes d \ \ \) NGTALL Connen Dore | | ws _ DEMO (E) SHINGLE SIDING ep pies 2 - < (N) WORK PARTIAL ROOF PLAN & INSTALL ONE LAYER % E39 =e on es ee Scale 1/4" = 10" (N) 5/8" TYPE "x" GWB 2 £ = (N94) N94 N94 E10 : > o uu TRUE PROJECT Ps | _ _ __ o NORTH NORTH < ON we as F.O. FRAMING t ~ 5 wm —_l. RB cet & rf) 2) i] N78 3 N94 (N94) i) { Tw o 2 x N q t. 4 nN - I\_ 2x12 WOOD LEDGERS TYP. ef a o oO L a oo 2) dog - i «a P2uns 9'-8 5/ .* ; 4" PANEL Fe + 1 " \ bis 2 = 42'-10" (V) ALIGNMENT OR (E) FLOOR 4-6 + a < a@ wi (N) SLAB PRIOR TO CUTTING ; i ° 3 hie - Nin (N) DOOR OPENING - NOTIFY ti. Sao- 2 x 12 WOOD FRAMING ARCHITECT OF DISCREPANCIES PREEZER i € F098 i] FOR SKYLIGHT 3A3.4 FOIO Sian Gu 4 se t 111 ~~ @ qq“ ozs 2 I é 5 ; * i) = iy - tr: 3. ~ o yi Oa 5 y (N76 < > o | > ALIGN (N) SLAB / “eq an - _ mn a = | wi (E) SLAB f E15 : (N94) & (N94) N94 < x S - " =) a N io) oO 4+ | oo F.O. (E) CMU "4 2x12 WOOD LEDGER | = Y _ Bs i e \ = \ W-i \ 426 °. Ws 7 7 NEW WORK FLOOR PLAN \ | \ \ N Scale: 1/2" = 1'-0" \. a ; TRUE PROJECT LY | / (N) WORK PARTIAL ROOF FRAMING PLAN NORTH NORTH ° £34 ae Ie Scale: 1/4" = 1'-Q" | ee penta OUTDOOR DINING SLAB - ALTERNATE #2 ; NORTH NORTH 1 + 23'-8" SECURE (N) FOOTING TO (E) 3.1 (N) CONG. FDN. WALL 3.3 I 0 4 E BARS 5" INTO (E) FTG. EQUAL é EQUAL é EQUAL . EQUAL r EQUAL a a oe & 1'-0" INTO (N) FTG. ee \, é © CRCACACAE RCRD — TF © Pa A a ae Oa Oa ee ae + SSS ee 7 a a OO GI, . OES ~~ Ce MAAC e rece ELFOOIING \@ * & eT; TTT S 0 ee en MS IRE PIERS Gee nae ME cen cnc ate ree tac ec omen tec ee snes rec TOs Stee mn ete eto eaNdioe AemEIT SMe ni Mie ecimentierceecnti rn tr Meanraarnunninin — encima erie: Recrearadayetstirat | Be seeeeeetc vreis etc Oc cctercaree ic topsee rte Bcteria eeee eesseceseceez merece ceeertarentsee ater ceeetctnee-ecenetoMteeeeeeattmccterueeegemeeetnerugeetzmre i nmrctoaec oes OTs LCOoTaTeron MF Te goer tome Lepesant ootcra abo pceSorce eee restora een arere nis eect bgeeetsseepiptcsttvor rerermeesr he 1 t co ty oF £8 FF KF # A FF FF PUP 4 ! ro) 1 } i i J Oo Pl Oa Wie ee ! e a 9 SN SN Ow SN SES OS HR NS ee op an fete eL6) io a | s e) 5] OP RAR) Jot 1 tii 4*conc.siapsiaa PT Pt sie mad i Ad Oe SASSASSIS SAFER TAA SECURE (N) FDN. WALL TO () dj) to ae | le Lo ae x ONG: NM N w/ (2) #5 BARS 5" INTO (E) WALL 1/8" WIDE x 1/2" DEEP [iLL a Bp 2 - |e ANN A RO oO. = & 1-0" INTO (N) WALL \ CONTROL JOINTS is pees eel eels : : fe aettenen Sects cat Seemeciey eet 1 ; << POPPE EN ogo EME Tai O =) > i Lt 1/8" WIDE 4 z _ R s bas weed pinot ie } Fig toa st | || ToL. eee CE ae cot < Ww 1 ] | sor(N)WALLERP | | (N) WALK-IN COOLER - FOIO _ lo (N) WALK-IN FREEZER & COOLER - FOIO \ © © * : 7“: t ay ct JOINTS Bal i o z Y) rd : li 12 12-11" FREEZER SLAB 1 1/2 i Fit TYP, i Wye | (N) EPOXY PAINT - (N) BASE (N) EPOXY PAINT - (N) BASE Zz 2 O x oak Q} am —? ~— —? ¢— Q Bt ! = ! i all =| < ox = ' ——4—| er y N i 1 “i _ wo fae i peered i } 5 % 1A3.4 4'-0" 2A3.4 O >< __— 22 —————— LL. ea ! 0 4 Lat 3.2P 2 z I Lid > nla ca =] ane x o —E G za = | d |} Wf | : ool wu) 1S — Ou WZ | 22s tT ne an T t | Oo za za Ce rp nt it de of YO <tOlis ~4-b4_, bo Y r | 4 e e CE CR CE, CCE hina <«_2)— AEA za. — cand - § — ee =| ! ! [i 3 > : RAAT AAR Os ON pean SN RORIIIOS RRS CAIN CNA RRO =e | esf— : to Se ss RN SS % FS ® %, é se YS RN ~“ NA ANN SNS SSRN % NOS RES SN NS NSH NR AR NSN NOY 4 (E) FOOTING * aps iN) ee TO (E —— z fo ie Serene Ce Vs A gl WA PN Nee Ree ANSON ASN RUA CREA UES UREA O > S ut / tO DB LO 44M A f id x a a OF let ae sl « Pr xa Me ee” cad ee Di Pat x ae gta KO” oy Pgt OE * ioe ere co { i ; : a1 0" INTO (N) FTG, i = i " a ros _~ ey ON? ied ie 7 WAN ae / trerererererere Perea eee t. RRNA UAC ‘a O pe | Lu Y) } ! 1 i + 5, 1 od > ee eK PES FP FP LE FFE S J of F 4 oe ° a a en a a a a er a a a a 2 a ee a ee ee Lu ~w = ; ' i 1 N l Ee I H| Liu . an a a ie Re ae ww OS . ra Pied Pa -* ee A a ihe erie bee ie fee rie ba ee be tr pe a es ed i Heal — | Ve if Oo < NOS SNR ON SS ae ae 4 ee % . ee i jam ane) pe) ‘ + Fi ' Pee Se ee ee ee ee io ~~ ? ™ oO af ghee a afet rl ce HR es ed 7 OE LN ars CALE rnd es nie Ne a ig An ar ee Nd LJ poe a | i ae Se eee eae +T=4 = ever ere ere wee So ert rrr eee See | ' ~T] +1 ra Rais ee nes CN 4 <r aay | ‘ | a Va CCCs KA NANA EASES | tw Lu J . J 4. — oan aapeeeenpeen yr £ S SES FF v HS SIS See gp at po Se ST SL , ar et CF CCC eee OF 5 ge ae se a oe ee CE OES eo) fom ime mat i i | | | EEE ee ] rl | : ——-o--—-9- +H Ate ey Pee Pe x FT « i Ss, \ Beate ta ae ets ee, ‘@) ‘aa < - _ = ' | 1 + ean Pea eae my \ ate ap * LN Fg ood oe ea oe ee oe a Septet Qo. - Zz eal ‘ fF | tT | av — ea 7 a or = x 5 Fae - = Faye \. Pre rare Pr Rr ena Lae ek Mo rh ek hea Lu — FA = DEMO TOP COURSE OF DELAY CUTTING OPENING FOR DOOR SECURE (N) FON. WALL TO (6 SS Dearie, Cents ON, Ue \ [Mae Far | RE | UAC, COREA NRCC AOAC Qs |§ 5 (E) CMU FDN. WALLS 126 AS LATE AS POSSIBLE TO AVOID (2) #5 BARS 5" INT Reals Gs La siete” fn be ra ttn Mn tan net TA @ (N) DOOR OPENINGS IMPACT ON OPERATION OF KITCHEN 1-0" INTO (N) WALL <= MAINTAIN CLEAR EXIT a: TO ACCOMMODATE (N) SLAB WITH TEMPORARY WALKWAY 1 4 (N) WALK-IN FREEZER} FOIO i CONTRACTOR < DURING CONSTRUCTION — (N) WALL FRP (N) WALL FRP BID SET N, N, Ny N, N (N) EPOXY PAINT - (N) BASE | | (N) EPOXY PAINT - (N) BASE | a y oN INTERIOR ELEVATION FLAG NOTES y oN A43 / N) WORK PARTIAL FOUNDATION / SLAB PLAN 3A3.4 4A3.4 . ( ) VY ‘ ) 4/4" = 1-0" NOTE: SHELVING & EQUIPMENT NOT SHOWN <<) FRP TOP CAP Sheet # 12of 25 sheets one cale: =1- SEE SHEETS A3.2 & A3.3 FOR SLAB INSULATION wi SEALANT BEHIND & INSIDE Tob Nomber \ Lae FRP "H" CHANNEL FRP INSIDE CORNER TRIM TRUE PROJECT 4" CONC. SLAB SLAB w/ #4 BARS @ 1'-0" O.C. EA. WAY soe eer INTERIOR SLABS TO RECEIVE SURFACE SEALER <2) wi SEALANT BEHIND & INSIDE <) wi SEALANT BEHIND & INSIDE FRP OUTSIDE CORNER TRIM FRP EDGE TRIM <:) w/ SEALANT BEHIND & INSIDE <5) w/ SEALANT BEHIND & INSIDE 1 5525 ARCHITEGT a JAMES R WILLIAMS STATE OF WASHINGTON (E) METAL FLASHING Gia) (E) METAL SCUPPER & DS (E) WOOD TRELLIS & TRIM (E) WOOD TRELLIS & TRIM (E) PLYWOOD FASCIA . (E) CMU PILASTER (E) CMU WALL ] | a rw TT 5 if L- oe Se | ITT é aa LIC] | j : } t %, ; ~TS HE ane — a aan va % | _ HL 7 ‘ (E) FREEZER ENCLOSURE ° > (E) ENTRY CANPOY / TRELLIS / DOORS & WINDOWS ‘ NO WORK NORTH SIDE OF BUILDING | 4 1/A5.2 A (E) WINDOWS \ { . 1 iL iT iE i iT if oa i 4 i i if i iT i: <a iT i i i Tt i 0 i . 1 } | im WT TTX rt ee ee ee k 5 _ i 7 ae — non | 3 vie / as 7 : | [nan - cA [ FOOD CO-OP tm ye ] , : mt 7] é : til | in LL ee eee eee (E) ENTRY CANPOY / TRELLIS ‘ (E) ENTRY CANPOY / TRELLIS $ NO WORK WEST SIDE OF BUILDING | y Ns 2/A5.2 (E) WOOD FRAME WALLS w/ CEDAR SIDING cc . 2 iar if rT I i iT if i i I I i i 7 Ir ir i T i af q q 1 = ‘ , = | bed =) a Il im = = . a é * i A FOO D CO- OP TT TE ~ if a rar U Ta I Ht Werte) epee teed tetera gett tpt pte = LW tt] bet te E | \/ (©) winvows / me LL NO WORK | /(N) FREEZER / COOLER /STORAGE ROOM SEE SHEET 5.2 NO WORK } Mn, 3/A5.2 1 3.1 3/A5.1 / > \ —_ 2/A5.2 1/A5.2 ~ ” VV yo \ n ay i < < + Z oe rH e ee oy pm hee TY TT NO WORK EAST SIDE OF BUILDING - - ¢ > . ° ¢ & a, v N 4/AS.2 nt i Wa ° .. > | 1/A5.1 bY TRUE PROJECT NORTH NORTH KEY PLAN NO SCALE -) S x Qo. < > an z fe) ~ a. vd Oo a uJ a Wu =~ < Pa > i a R a) ° Yo 2 oo 4 n 9 L) oo o - < o foo Pilg =a _ -NO tT) 200 p< x29 ot 3 Nig 295 ) Sg aus ¢ oz 2 Sig. <2 Yai Sa 5 s< 8 3 i) = x4 x < 5 )) as a) Oo. QO. a PZ S O° 5 OR 7 az Be So im ” LL Ss D = LJ za wn 2 ss NO |zZ6iis Se lee SS | 26. ~ SS | oe Z rim | 28] 3 ae a. wi = CONTRACTOR BID SET Ad.1 Sheet # 130f 25 sheets Job Number TT Ty FOOD a j onli ft ttl Li Lilt ETT Ll Lino CO-OP iim | = r =— (E) TO REMAIN UNCHANGED y N MATCH LINE "A" 1/A5.2 (N) METAL FLASHING (N 1 /(N) METAL SCUPPER & DS MATCH (E) N) METAL SCUPPER & DS MATCH (E) (N) ‘CONNECT TO (E) UNDERGROUND (N) MDO PLYWOOD TRIM CONNECT TO (E) UNDERGROUND DRAIN LINES FOR DOWNSPOUTS DRAIN LINES FOR DOWNSPOUTS w/ 4° @ SOLID SCHED. 40 PVC r CEDAR SHINGLES wi 4" @ SOLID SCHED. 40 PVC it ]] ei TT \ = ae 7 - a Cala 1 ji orf yf "f - (E) TO REMAIN UNCHANGED - a \ /._# — @ i ALTERNATE #2 - (N) DINING SLAB & FOOTING NN (N) CONC. FDN. W LLS & FOOTINGS (N) CONSTRUCTION - BASE BID Op - e d (E) TO REMAIN UNCHANGED MATCH LINE "A" y 2/A5.2 (N) METAL SCUPPER & DS MATCH (E) CONNECT TO (E) UNDERGROUND DRAIN LINES FOR DOWNSPOUTS wi 4" @ SOLID SCHED. 40 PVC pcm mest Bere S trerere! cEeceoe. \ | =; == ! im “EI \ fa wae con woe wen aoe a oe ee bus} aonsoel a lee f i ; ; a ee at 2 - 7 a as ce ss af te a a a ane se sn an etna esr ue sts nse st te teste cman net wae nfs zee at cee sn te te sett tra i tes sn este an ne em a0 nt snes a en susan oe ane ad bees: pl eee apenerpeng \ (N) CONSTRUCTION - BASE BID (E) TO REMAIN UNCHANGED a 3/A5.2 (N) CONSTRUCTION - BASE BID 4/A5.2 4/ A 5 . 1 AI A S . 2 1/A5.2 Ma, 1/A5.1 bY TRUE PROJECT NORTH NORTH KEY PLAN NO SCALE 2/ A 5 . 1 ARCHITEGT- \. : JAMES R WILLIAMS STATE OF WASHINGTON 2) S i o. < > oo z 2) aoe a. Fd O a Lu ra) Ww - < Pa > if ow N Oo] & p t To 2 N QO 4 un O Li oo o - o Soo ci NG FT) 2mo I< T2® ohn tig z07 yi 393 > am. guus { 7“ oz 2 Ji. 92 Zé + = Wal ea 3 T< OG o a < x << 5 CS } ow | « a PO R T TO W N S E N D FO Q D CO - O P RE N O V A T I O N & EX P A N S I O N NE W WO R K EX T E R I O R EL E V A T I O N S Da t e AP R I L 11 , 20 1 1 Ap p r o v e d by JI M WI L L I A M S Dr a w n by JI M WI L L I A M S CONTRACTOR BID SET AS.2 Sheet # 140f 25 sheets Job Number a AAA mi eT TTT i iu / = | if = E | (NO4 N94 Nod NO4 ) INO | = N92 E N94 | | S — 2 [ENO] | ES2IES2IES2 Nod | (Nod | [NO” = | —_||E N94 = I "= is Ss | — i ceana| \ OOO] ema] i FREEZER | LES | “_S _ | I I ET] a ‘aa | [E16] | | Fl} og | | __nvy FD ! | | | LW E26 LJ < O LL — = GRAB & GO = CASE m7 = a CHEESE _— — | m7 = WW =" CASE _ CH E E S E CA S E Port Townsend Food Co-op Equipment list both new & existing April-21-2011 EXISTING Equipment RC-Refrigeration Contractor EL-Electrical Contractor PL-Plumbing Contractor GC-General Contractor Item # Description Brand Qty Width Depth Height {Supplied bInstall by |Electrical Plumbing Notes Comments E1 SS Hand Sink Existing 1 14 16 E2 SS Table Existing 1 62 24 E3 Meat Grinder Existing 1 Owner — |El/Owner]/115/1/5A Relocate To Meat Room E4 SS 2C Prep Sink Existing 1 63 24 E5 SS 3C Dish Sink Existing 1 78 29 E6 SS Table Existing 1 48 30 E7 Dishwasher Existing 1 E8 SS 1C Dish Sink Existing 1 66 30 E9 SS 1C Prep Sink Existing 1 24 24 E10 Cart Existing 1 16 24 E11 Hood Existing 1 84 48 E12 Range Existing 1 36 33 E13 Oven Existing 1 27 32 E14 Shelving -3 units Existing 3 E15 One Dr Refrigeratior Existing 1 27 30 Owner El/owner |115/1/7.8A Relcoate To new deli storage area E16 Work Station w HS Existing 1 112 24 E17 2 Dr Refrigerator Existing 1 54 33 Surplus Replaced by N79 Co-op to Remove E18 2 Dr Refrigerator Existing 1 54 33 E19 Mobile Shelving Existing 1 E20 SS Table Existing 1 48 30 E21 Scale Existing 1 Owner El/owner |115/1/3 A Relocate To Meat Room E22 Wrapper Existing 1 Owner _ |El/owner}|115/1/4A Relocate To Meat Room E23 SS Table Existing 1 30 24 E24 Slicer Existing 1 E25 Wire Shelving Existing 1 12 36 E26 SS Table Existing 1 48 30 E27 Shelving -3 units Existing 1 36 24 E28 U/C Refrigerator Existing 1 48 30 E29 SS Table Existing 1 60 36 E30 Hobart Mixer Existing 1 owner El/Owner|1/2 hp 115/1 see plan In storage/set in place by Rene E31 Spare Number E32 Platter Carts Existing 2 Owner Relocate Rene E33 Dollies Existing 3 Owner Relocate Meat Cooler NEW EQUIPMENT N50 Spare Number N51 1 Shelf above E33 SSP 1 EAA Owner Rene may use lozier for this N52 Spare Number N53 Meat Cooler Custom 1 96 609" EAA RC/EL/PL Remote Compressor on Roof Heathcraf 1 EAA 208/3/20 amps Sleepers/roof pentrator by GC Evaporator coil in cooler Heathcraf 1 EAA 230/1/1A &10.5A Draintine heat tape EL EL EL 120/1/20 A Wrap coil drain to exterior of cooler Cooler lights Custom 2 EAA EL 120/1/20 Jelly jars hung to ceiling and wired Impact door w/windows Chase 1 36 84| EAA RC N53A Meat Prep coil ceiling hung Heathcraf 1 EAA RC/EL/GC|115/1/3A Drain to KitcH Need GC to make a hole in wall for drair N54 Table SS SSP 1 72 24 EAA Owner/PL N55 Custom HS and Support W/shelf SSP 1 24 24 EAA PL 1/2" CW 1/2" HW 11/2" Ind W Splash guards on sides of hand sink N56 SS 1C prep Table SSP 1 48 24 EAA P| 1/2" CW 1/2" HW 11/2" Ind W N57 Spare Number N58 Door with window Chase 1 36 84|EAA GC Metal C-channel or tube steel N59 Flat top black grocery cart Rub 1 Owner N73 Buss Cart New Age 1 EAA N77 Utensil rack Metro 1 EAA Owner Rene N79 SS Prep Table w/o undershelf SSP 1 72 36 EAA Owner Rene N92 Cooler/Freezer Combo Custom 1|per plan EAA RC/EL/PL Compressor toruncooler portion |Heathcraf 1 EAA RC/EL/GC|208/3/15 amps Sleepers on roof and roof penetration Evaporator coil in cooler Heathcraf 1 EAA RC/EL/PL |208/1/1A & 11.7A Floor sink needed Refrig Co will run drain to floor sink Compressor to run Freezer Portion |Heathcraf 1 EAA RC/EL/GC|208/3/29 amps Sleepers on roof and roof penetration Freezer pit 1 GC GC See Details on Architects plans Evaporator coil in Freezer Heathcraf 1 EAA RC/EL/PL |115/1/2.9 amps Floor sink needed Refrig Co will run drain to floor sink Heated Vent Custom 1 EAA El 115/1/4 amps Freezer lights 2 EAA EL 115/1/20A Jelly jars hung to ceiling and wired Impact door w/window on Cooler |Chase 1 36 84|EAA RC Freezer Door Custom 1 EAA RC Heat Tape on drain line EL/RC 115/1/20 am heat tape by Electrician/drainline by RC N93 Spare Number N94 Cooler/ Freezer/Backroom Shelving |Lozier Various Owner Rene will erect and install N95 Spare Number N96 Platter Carts flat top New Age 1 EAA To match existing co-op hot cabinets N97 Grab and Go case Hussmanr 1 EAA RC/EL/GC|See electric for specs To existing drain by RC sleepers and roof penetration for comp! 115/1 for lights and fans from | existing grab and go case LDG [architects linardic design group architects 1319 dexter ave. north, suite 260 seattle, wa 98109 (206)283-4764 fax (206)283-1293 NOT PUBLISHED. ALL RIGHTS RESERVED. THE ABOVE DRAWINGS AND SPECIFICATIONS AND IDEAS DESIGNS AND ARRANGEMENTS REPRESENT THEREBY ARE AND SHALL REMAIN THE PROPERTY OF THE ARCHITECT. NO PART THEREOF SHALL BE REPRODUCED. COPIED. ADAPTED. DISCLOSED OR DISTRIBUTED TO OTHERS. SOLD. PUBLISHED. OR OTHERWISE USED WITHOUT THE PRIOR WRITTEN CONSENT OF AND APPROPRIATE COMPENSATION TO THE ARCHITECT. VISUAL CONTACT WITH THE ABOVE DRAWINGS OR SPECIFICATIONS SHALL CONSTITUTE CONCLUSIVE EVIDENCE OF ACCEPTANCE OF THESE RESTRICTIONS 4423 REGISTERED ARCHITECTS EDI LINARDIC STATE OF WASHINGTON consultants: E. Alexander & Associates PROJECT MANAGER: E. ALEXANDER & ASSOCIATES P.O. BOX 549 EDMONDS, WA 98020 (425) 776-5323 (425) 776-5245 FAX project title: PROPOSED PROJECT FOR: PORT TOWNSEND CO-OP GROCERY STORE REMODEL PORT TOWNSEND, WA sheet title: PARTIAL FLOOR PLAN AND SCHEDULE CORRECTED SCHEDULE 8-6-10 REVISED PLAN AND SCH 4-21-11 no:| revisions date: job no: sheet no: draw: K-1 checked: date: 8-5-10 MECHANICAL SYMBOLS LEGEND SYMBOL ABBR. DESCRIPTION = MECHANICAL EQUIPMENT = DIFFUSER /GRILLE TYPE : CFM DETAIL NUMBER SHT. WHERE DETAIL IS DRAWN ay FLAG NOTE J REVISION NOTE aes LINED DUCT Wwr- FLEX DUCT c=) [x SUPPLY DUCT y RETURN OR EXHAUST DUCT SUPPLY DIFFUSER / GRILLE RETURN OR EXHAUST GRILLE tb VD VOLUME DAMPER “ TURNING VANES © TEMPERATURE SENSOR OBD OPPOSED BLADE DAMPER GSM GALVANIZED SHEET METAL AFF ABOVE FINISHED FLOOR NTS NOT TO SCALE as STAINLESS STEEL AP ACCESS PANEL EX EXISTING CX CONNECT TO EXISTING RLX RELOCATE EXISTING RX REMOVE EXISTING VD VOLUME DAMPER 1. PLUMBING FIXTURES SHALL BE DESIGNED OR EQUIPPED TO MEET FOLLOWING WATER USE EFFICIENCY STANDARDS: a. WATER CLOSETS (TANK STYLE OR FLUSH VALVE). 1.6 GPF. b. URINALS. 1.0 GPF c. SHOWER HEADS & BATHROOM FAUCETS. 2.9 GPM d. LAVATORY & KITCHEN FAUCETS. 2.0 GPM SINK AND LAVATORY DRAINS SHALL BE CHROME PLATED 17 GA. BRASS TUBING BY ENGINEERED BRASS, DEARBORN OR BRASSCRAFT. PROVIDE INSULATED P—TRAP & SUPPLY COVERS (TUEBRO OR EQUAL) @ ALL EXPOSED P-TRAPS & SUPPLIES PER A.D.A. STANDARDS 2. PLUMBING FIXTURE MOUNTING SHALL COMPLY WITH CONTRACT DOCUMENTS AND INTERNATIONAL BUILDING CODE 2009 CHAPTER 1109.2 (ACCESSIBILTY) 5. INSTALL WATER HAMMER ARRESTORS ON HOT AND COLD PIPING OF EACH FIXTURE GROUP AND AT ALL FIXTURES W/ QUICK ACTING VALVES. UNITS SHALL BE EQUAL TO ZURN ”“SHOKTROL”. SELECT UNIT SIZE AND LOCATION PER MANUFACTURERS RECOMMENDATIONS AND IN ACCORD WITH PDI STANDARD WH-201. PROVIDE ACCESS PANELS AT ARRESTORS ABOVE GWB CEILINGS. 4. COLD WATER AND HOT WATER PIPING SHALL BE INSULATED & ROUTED FULL SIZE WITH APPROPRIATE SIZE REDUCTION INSULATED & AT POINT OF CONNECTION TO FIXTURE. 1/2” WATER LINE LIMITED TO 10’-0" DISTANCE FROM FIXTURES. "DEAD-LEGS” OR "FUTURE STUBS” ON ACTIVE POTABLE WATER LINES SHALL BE LIMITED TO 4” TO PREVENT STAGNANT WATER CONDITIONS. 5. INSTALL WATER PIPING ON WARM SIDE OF BUILDING INSULATION. nN © TERMINATE INDIRECT RAIN LINES AT ” NK. ! ho AAA, \ WA VAAN AAV co — Or) EX. FLOOR DRAIN —\| # EX. GREASE TRAP \| REMAIN IN PLACE EX. VENT FROM SNOT EOE TE LET A TNE STEAMER LOCATION GREASE TRAP ¢ / EX. WASTE 1/2” H&CW, 2” IW TO HAND SINK N56. aN (ED BREASE ARAP ww TRUE NORTH /; /2” He Cw, \2” IW TO HAND SINK N 2 3/4” H&C | DN | a _ © a Lu CONNECT NEW H&ecwl EX. PIPE. FIELD VERIFY EXISTING LOCATION. L DE L I SE R V I C E CA S E = CH E E S CA S E a — | —_ NEW WORK FLOOR PLAN PROJECT NORTH Scale: 1/4" = 1 "0" aN OL I V E S CHE CA PLUMBING FIXTURE SCHEDULE MARK | FIXTURE MAKE:MODEL DESCRIPTION WC-+1 WATER KOHLER: WALL-MOUNT. SIPHON JET, ELONG. RIM., VIT. CHINA, CLOSET 4330 1 1/2" TOP SPUD. WHITE. 1.6 GPF, MOUNT @ 18” RIM HEIGHT. SEE ARCH. DWGS. FOR MOUNTING HEIGHT. SEAT LUSTRA WHITE PLASTIC, OPEN FRONT, W COVER. K-4650 FLUSH SLOAN: VALVE "ROYAL" #111 UR-1 — |URINAL KOHLER: WALL MOUNT, SIPHON JET, VIT. CHINA, 3/4" TOP K-4989-T SPUD, 1 GAL. FLUSH, WHITE, A.D.A. COMPLIANT. VALVE SLOAN: "ROYAL" 186-1 LAV-1 LAVATORY KOHLER: 17" X20"OVAL, COUNTER TOP, SELF RIM, VIT. CHINA, 2196-4 4" CTRS, WHITE. FAUCET CHICAGO: 4 1/2" SPOUT. AERATOR. SGL. LEVER HANDLE, 4" 22004E 2805CP GHROME PLATE. CTRS, VANDAL RES. DRAIN CHICAGO: PERFORATED STRAINER. FLAG NOTES 0 _s EXISTING PLUMBING FIXTURE SHALL BE MOVED TO NEW (SHOWN) LOCATION. CONTRACTOR SHALL BE RESPONSIBLE TO REMOVE, STORE IN A PROTECTED PLACE AND REINSTALL FIXTURE AT NEW LOCATION. CONTRACTOR SHALL ALSO BE RESPONSIBLE TO DISCONNECT AND SEAL EXISTING PIPING AND REINSTALL NEW PIPING AS NECESSARY. NEW ISOLATION VALVES SHALL ALSO BE PROVIDED BY THE CONTRACTOR. SEE ARCHITECTURAL PLAN A2.1 FOR EXISTING LOCATION. (23 = PLUMBING FIXTURE TO BE FURNISHED BY KITCHEN CONTRACTOR, INSTALLATION AND ALL PIPE CONNECTIONS BY M.C. (3m —sRUN DRAIN PIPING IN WALL WHERE POSSIBLE. EXPOSED PIPING SHALL BE INSTALLED TIGHT TO WALL AND STACKED. 4 LOCATION OF EXISTING WASTE PIPING UNDER SLAB IS UNKNOWN. CUT SLAB AS SHOWN ON DRAWING A4.1 AND LOCATE WASTE LINE AT THIS AREA. CONNECT NEW PIPING TO EX. 4” LINE UNDER SLAB. ALL WORK SHOWN HERE IS UNDER ALTERNATE BID #1 _ L 1-1/4" CW TO WC & URINAL 1/ 2” H&CW T LAVATORIES EX. & RELOCAT LAV eee MET NT ww TRUE NORTH 2-1/2” V DN O EX. WC REMAINS IN PLACE EX. WC REMAINS 1 IN PLACE CONNECT NEW 2-1/2” V TO EX. VENT. FIELD VERIFY EXACT LOCATION. I NEW WORK FLOOR PLAN Scale: 1/4" = PROJECT NORTH 1 '.0" [ EXPIRES 11/30/10 | ~ & > fa fan < > faa) z oO = QO. ~ O ep) LW OQ LJ kK < a > Ld aa ne <= ~9 _ ae | - €& se) < a0 8 NN co | w + f}gons O mM Oo ro) ine ~ig=s8 = OO Cc “© © elge 8 co <l S. 2 ols 3s EMs.5 S < = =KWxts = © ~oN ” a | o Men 5 Se > | one oO a AU G U S T 2, 20 1 0 Da t e Ap p r o v e d by GC H PO R T TO W N S E N D FO O D CO - O P RE N O V A T I O N & EX P A N S I O N SC H E D U L E S AN D FL O O R PL A N - ME C H A N I C A L Dr a w n by GC H PERMIT APPLICATION SET M2.1 Sheet # 7 sheets Job Number Microfile Number K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 QO NOTES (APPLICABLE TO ALL ELECTRICAL DRAWINGS): E L EC TR | CAL L EG END S & ial 1. ALL WIRING SHALL BE ENCLOSED WITHIN THE RACEWAY SYSTEM. < LIGHTING 2. BELOW GRADE CONDUIT SHALL BE SCHEDULE 40 PVC, DIRECT BURIED A MINIMUM ——— > OF 24" BELOW GRADE WHEN NOT BELOW THE BUILDING'S CONCRETE FLOOR SLAB. co c— FLUORESCENT LUMINAIRE, SURFACE MTD. 3. ABOVE GRADE CONDUIT SHALL BE 3/4” EMT UNLESS NOTED OTHERWISE, EXCEPT FLEX Aa (Aa + FIXTURE TYPE A CONTROLLED SHALL BE USED FOR FINAL CONNECTIONS TO VIBRATING EQUIPMENT MAY BE BY SWITCH $a, TYPICAL) G) () ) @) SUBSTITUTED FOR EMT WHEN RUN CONCEALED WITHIN WALLS & CEILINGS. FLEX | | SHALL NOT BE USED FOR HOME RUNS. oe FLUORESCENT STRIP, 2 LAMP | | | | | 4. CONDUIT SHALL BE RUN CONCEALED UNLESS NOTED OR INDICATED OTHERWISE __ | _ | ° EXCEPT, FINAL RISERS AND DROPS TO EQUIPMENT, SURFACE MOUNTED PANELS, ETC. pel INCANDESCENT OR SIMILAR, CEILING MTD SHALL BE EXPOSED, AND CONDUIT WITHIN MECHANICAL & ELECTRICAL ROOMS, | es ETC. MAY BE RUN EXPOSED. : z 5. BELOW GRADE FEEDER CABLE SHALL BE 1/C STRANDED COPPER (UNLESS SWITCHES © i je SPECIFICALLY NOTED OTHERWISE) WITH 600V TYPE USE/RHW/RHH/XHHW INSULATION. 4}—— <I ap F ( g SINGLE-POLE SWITCH Pe >t z | e i 6. BRANCH CIRCUIT CABLES, EQUIPMENT GROUND CABLES & ABOVE GRADE FEEDER Oo CABLES SHALL BE 1/C COPPER, #12 AWG UNLESS NOTED OTHERWISE, WITH 600V 55 THREE-WAY SWITCH Ms TYPE XHHW OR THHN/THWN INSULATION. gP SWITCH WITH PILOT LIGHT 7. CEILING MOUNTED CORD REEL CORDS SHALL BE 2/C + GND #12 AWG TYPE SO CABLE m WITH PLUGS, RECEPTACLES, ETC. AS REQUIRED & SUPPORT GRIPS. VERIFY EXACT A , < LOCATIONS WITH OWNER PRIOR TO INSTALLATION. Sup WEATHERPROOF SWITCH a 8. SEE ELECTRICAL SPECIFICATION FOR SYSTEMS CABLE TYPES. Sms MOTION SENSOR SWITCH o—- _ = LL 9. _ INADDITION TO THE CIRCUIT CONDUCTORS INDICATED, CONTRACTOR SHALL PROVIDE ® MOTION SENSOR, CEILING MTD. [i “ AN EQUIPMENT GROUND CABLE (SIZED THE SAME AS THE LARGEST CIRCUIT © CONDUCTOR UNLESS SPECIFICALLY NOTED OTHERWISE WITHIN EACH RACEWAY MOTION SENSOR CONTROLLER E WITH THE CIRCUIT CONDUCTORS). o > Le) 10. VERIFY ALL EQUIPMENT, DEVICE, ETC. LOCATIONS WITH THE OWNER & ARCHITECT | > im PRIOR TO ROUGH-IN. SEE MECHANICAL DRAWINGS FOR LOCATION OF MECHANICAL OUTLETS a oO] « EQUIPMENT, ARCHITECTURAL DRAWINGS FOR SPECIALTY EQUIPMENT, KITCHEN So < S| 5 EQUIPMENT SUBMITTALS FOR KITCHEN EQUIPMENT, ETC. e@= DUPLEX OUTLET © v 4 K 8 " —}— O 1° SR: @ cn 8 DEMOLITION NOTES (apPLICABLE TO ALL ELECTRICAL DRAWINGS): Se DUPLEX OUTLET, GROUND FAULT INTERRUPTING = Kdsa : Ss) a S Ed 1. CONTRACTOR SHALL REMOVE EXISTING EQUIPMENT, FIXTURES, DEVICES, ETC. AS Sip DUPLEX OUTLET, WEATHERPROOF <z Kd Ee INDICATED IN THE WORK AREA AND ALL ASSOCIATED CONDUIT, BOXES, o kg iF 3 CABLES, ETC. SHALL BE REMOVED TO THEIR POINT OF ORIGIN &/OR DESTINATION, ® SPECIAL PURPOSE OUTLET E ¢ es EXCEPT: Zhi a: a) SPECIAL PURPOSE CONNECTION os ag x @ A. CONCEALED CONDUITS MAY BE ABANDONED IN PLACE. CABLES HOWEVER C.. og & SHALL BE REMOVED WITH A PULL STRING ADDED AND THE CONDUIT SHALL BE < TELECOMMUNICATIONS OUTLET = © CAPPED AND LABELED (WHERE IT GOES) ON EACH END. J | 2. EXISTING FEEDERS, CIRCUITS, CONDUITS, CABLES, ETC. INTERRUPTED DUE TO THE SYSTEM UPGRADE SHALL BE RE-CONNECTED AS REQUIRED TO MAINTAIN THE ANCILLARIES ORIGINAL FUNCTION. FF) FIRE ALARM MANUAL PULL STATION 3. EXISTING EQUIPMENT, FIXTURES, DEVICES, ETC. TO BE RE-USED IN THE NEW WORK SHALL BE REMOVED CAREFULLY, & PROTECTED FROM DAMAGE AS REQUIRED iaet c16E AL Agt WoaMi uit Gees vicar DURING DEMOLITION & CONSTRUCTION. (ied UNLESS NOTED OTHERUIGE) 4. ALL SURPLUS MATERIAL REMOVED DURING THE DEMOLITION SHALL BE INSPECTED FIRE ALARM STROBE LIGHT BY THE OWNER, AND THOSE ITEMS SELECTED SHALL REMAIN THE PROPERTY OF (\5ed UNLESS NOTED OTHERWISE) THE OWNER. ALL REMAINING SURPLUS MATERIALS SHALL BE REMOVED FROM THE SITE & DISPOSED OF BY THE CONTRACTOR. © FIRE ALARM SMOKE DETECTOR @)) FIRE ALARM FIXED TEMP. HEAT DETECTOR ® FIRE ALARM RATE OF RISE HEAT DETECTOR EOL END OF LINE RESISTOR MISCELLANEOUS Ht ——___ BRANCH CIRCUIT, ABOVE GRADE, CONCEALED (OR SIMILAR, 7 LY SLASHES = NO. OF CIRCUIT CONDUCTORS WHERE APPLICABLE) +H BRANCH CIRCUIT, ABOVE GRADE, EXPOSED (OR SIMILAR, SLASHES = NO. OF CIRCUIT CONDUCTORS WHERE APPLICABLE) fall = oO ao O WN GROUND CABLE } a non} - ne ©O z Lu] : HOMERUN TO LOCATION INDICATED, CONCEALED (TYPICAL) O 5 ac OW Ziec > HOMERUN TO LOCATION INDICATED, EXPOSED (TYPICAL) 5 é - Zz ------- — BELOW GRADE CONDUIT a >< ° Q) uw 0) JUNCTION BOX > LU =) Zils EXHAUST FAN ELECTRICAL - SITE PLAN _ LL} © <i a Scale: 1" = 20'-0" 2 Zz ai 6 ak a, DISCONNECT SWITCH TRUE PROJECT = O E NORTH NORTH 5 _ ” wy <l —! (ZZZZ3 PANELBOARD ES S EX EXISTING TO REMAIN KO = rz 5 — OW uy |2 — oar mig EXISTING TO BE REMOVED, TYPICAL E1.1 Sheet # of sheets Job Number 1433 Microfile Number K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 O S fr a) @ @ o © © a o > a O C) EXISTING PANEL Pe RELOCATE / 7 BRSIING PANEL PS = I 7 Zz EXISTING MAIN | EXISTING PHOTOELECTRIC CONTROLS s QUITCHBOARD POWER” Uji (REMOVE 4 RELOCATE) | | Er oc EXIGTNG EXTERIOR MECH. ||} | OUTSIDE g CONTACTOR- —= Ss 4 | DINING : | SLAB | | | TELECOM || O O © e O MDF al = (a) _ _ ne Fed+—u+—4_TO EXISTING LIG. cH H ; _ | |. 7 oe < = — — te 3 : r Oo il qu imexeye) m. é L | Aibect Tip ie bs r Se | ENTER [2 Lio 4 | be O > x ti tt | O ac | a palh \ | HES = cP 3 | Hoey? I i] | | Le) — a | | eer 1 ee | Cc © Sx ral) & ap PUL Bndbacal i GRAB & GO > . / dt tt CASE L + K N_s — | ALTERNATE * 3 1 0 QO aks ‘ bH=4 | a oN gs i oi peat = - s4 rg 5 7) REMOVE 4 RELOCATE +h a | © < \d : g Th in ==4 1] Qa. TO NEW LOCATION \ \ _— i a | ee | ds 8) [oT TT} a a S 3S, y ---- oy cis = N | a MIE 2 XISTING RANEL P2 | I = Ks 5 a RELOCATE EXISTING v as LIGHT FIXTURE 4 —" E < © REINSTALL AT NEW G - LOCATION | a) | i a rh Z Z ' = HVE EXISTING GUTLET, RACEWA Z = a +— a w = mn | = _ b _ _ a _ a a { WIRING BACK TOMEW DEVICE. | 7 ~ [7 — I- —O— — -— REC(INNECT CIRCUIT|TO MAINTAIN —ALLIDOUNSTREAM 1 jvices | I ——w EXISTING BASEBOARD HEATER (TO|REMAIN co f , | 1 ok a | \ i XISTING PANEL P4 | | | | I] | ALTERNATE * | EXISTING EXHAUST FAN \ | | = =I" a oO pe -< —_ | STARE || : | l _) i EXISTING BASEBOARD HEATER re) | | ! SZ] [| y Ol i ENTER | (TO|REMAIN (¢ _ = C — I Cc | ro roy Co an _ _ U] = ) On AR ey eae \ ii | Oo - EXISTING PANEL P4A 7} O 0) ® e e Lace Q x ! O z ss = WALK-IN OO $| o | AN the | Oz O RECEIVING e e e O) O s 5 — >< g of | | WALK-IN He | e el 0 Qz EIR ® | 1 za O 2) < bl se | | : Oc - —— Scale: 1/8" = 1'-0" F- > . TRUE PROJECT = © - NORTH NORTH O Ww O |= a | ow mig & Sheet # of____ sheets Job Number 1433 Microfile Number a SEE DETAIL ON DRAWING E31 | | © ° | | | 6 ______@___——__.._@ o | | ee | STAFF 7 XISTING PANEL P4 P. "1d Ex NN NTI HAND DRYER— — REINSTAULIEXISTING T-STAT ; (I2A, I2Ov, |¢) AT NEW LEDC ATION | ll O 3-20, 22 < HH a= ~ e ( r—— EX ISTING B K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 ASEBOARD HEATER © ECONNECT) INTERCEPT| EXISTING CIRCUIT WITH NEW J;BOX ¢ EXTEND WITH NEW r—— EXISTING BASEBOARD HEATER | ALTERNATE * | ECONNECT) EXISTING PANEL P4A +} | =z Om m m m ii | L HAND DRYER er net Leen NX (2A, Ov, |8) '— REINSTALL EXISTING T-STAT ELECTRICAL - POWER PLAN _ Scale: 1/8" = 1'-0" TRUE PROJECT NORTH NORTH . AP R V ' D BY DE S C R I P T I O N DA T E RE V il i a m s Ar c h i t e c t US G B C AA A A A W J P O Bo x 30 2 6 4 , Be l l i n g h a m , WA 98 2 2 6 - 4 3 7 7 Ph o n e / F a x 36 0 - 7 3 3 - 2 5 6 1 em a i l - j i m w i l i a m s | S @ c o m c a s t ne t ale Q Oz OO AW O27 Oc aS a > WW a Zz SE ES Law i S O wW © Da t e AP R . 11 , 20 1 1 Ap p r o v e d by ST V EL E C T R I C A L - PO W E R PL A N Dr a w n by KL Sheet # E2.2 sheets Job Number 1433 Microfile Number EXISTING PANEL P6 PANEL P1 EXISTING PANEL P5 EXISTING EXTERIOR TIMECLOCK 4 CONTACTOR | PROVIDE NEW 3-WAY EXISTING PHOTOELECTRIC CONTROLS (RELOCATE TO|THIS NEW LOCATION 4 RECONNECT) | = n nT TTT DELI COOLER INTERCEPT EXISTING 4 EXTEND WITH NEW K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 B y— are SWITCHING SYSTEM , C C O O O; DELI FREEZER ip PS (a) ee — 7 = TO EXISTING LTG, tom m4 - 7 ee meres oe are = _ . l - ft lOO | ¥ To ree r | | He , A : ] O INTERCEPT EXISTING J-BO: LJ | | EXTEND WITH NEW O T0 REMOVE EXISTING SWITCHES 4 |_ROUGH-IN BOX 4 PROVIDE NEW | XISTING PANEL P2 |_| RELOCATE EXISTING LIGHT : | FIXTURE TO NEW LOCATION, INTERCEPT EXISTING ¢ | L_EXISTING FRANEL LI | EXTEND WITH NEW =XISTING PANEL , 1 B) (e) _ _ 7 7 - _ _ | _ _ - Hl ~l6f- - - = - | z _ _ i bn = =, - 6 _ z, aman || Sie ors _ - l Sa CONNEC Cc | | | . ISTING C | | | ALTERNATE *| 7 | a | _ | ISTING EXHAUST FAN XISTING PANEL P4 _— | ELOCATE TO MISS NEW et | \ \ \ J pl sHT & RECONNECT) i Oo }- =~ | AN STAFF | rd 2 asl = SOX OIL = ENTER = I L_$ —_— co = —_— uz 1] Leese | - =, | : ; Oo C - - - co co co (ua - - Co mol ae - : : | MOUNT IN | | : ) FLUSH MTD. EXISTING PANEL P4A-1 oO b e O _ 9BOx, TYPICAL. otn oP) _— | | CD e oe C) 4 (2 ELECTRICAL - LIGHTING PLAN _ (S Scale: 1/8" = 1'-0" TRUE PROJECT NORTH NORTH AP R V ' D BY DE S C R I P T I O N DA T E RE V il i a m s Ar c h i t e c t US G B C A AA A A P O Bo x 30 2 6 4 , Be l l i n g h a m , WA 98 2 2 6 - 4 3 7 7 W J 36 0 - 7 3 3 - 2 5 8 1 Ph o n e / F a x em a i l - ji m n i l i a m s | S 5 @ c o m c a s t . n e t PO R T TO W N S E N D FO O D CO - O P RE N O V A T I O N & EX P A N S I O N EL E C T R I C A L - LI G H T I N G PL A N AP R . 11 , 20 1 1 Da t e Ap p r o v e d by ST V Dr a w n by KL Sheet # Job Number of sheets 1433 Microfile Number K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 QO S i 1 I I | i 1 a | (| | ! ~ I | I i ! | | | | | | ! ! za 2) ke i | 1 | ! a. i O (op) | | | Ww a FIRE ALARM BOOSTER POWER SUPPLY BPS-I (MOUNT BELOU EXISTING FAP) | : io) O O . [24] "l = = ma = i te ~~ EH T C1 => a: “kk a ja) , = robo 3 i i] > EXISTING FIRE ALARM/SECURITY PANEL FAP — ty (FAP IS DSC, MODEL MAxSY$ Pc4o20cr. | | | | MODIFY 4 EXPAND TO ACCOMODATE NEW | | | DETECTION ¢ ALARM ZONES AS REQUIRED) || “\ t ) a : rt | S| 5 H \ | j T ! | 3 Waa: E 0) @ g a8 : | a? L_] = £ 5 O a pa ESR _ : IO < @a8% wo @ = oa) eee INTERCEPT EXISTING ! : ! S138) J-BOX 4 EXTEND | ot = KR: , WITH NEW Is 5°35 Le) a W J id | “4 | ] \ \ A ! / 4 , | | " 7 FAP, RNATE * | ( t [| | | 4 | | | | | | a | | | | STAFF | | | | | | | aa n (| : AP R . 11 , 20 1 1 Da t e O e le Ap p r o v e d by ST V La | _ELECTRICAL - ANCILLARIES PLAN | Scale: 1/8" = 1'-0" TRUE PROJECT NORTH NORTH CABLE CODES CODE FUNCTION DESCRIPTION COLOR NEC TYPE CABLE ROUTING PO R T TO W N S E N D FO O D CO - O P RE N O V A T I O N & EX P A N S I O N EL E C T R I C A L - AN C I L L A R I E S PL A N Dr a w n by KL H F.A. SYSTEM NOTIFICATION (HORNW/STROBE) CIRCUIT [2 - 1/C STRANDED #14 AWG BLACK/RED THHN/THWN__ |RACEWAY EXCLUSIVELY Z F.A. SYSTEM ZONE DEVICE LOOP 2 - 1/C SOLID #16 AWG ORANGE/YELLOW|TFEN RACEWAY EXCLUSIVELY NOTES: 1. ALL CABLING SHALL BE IN RACEWAYS. E2 4 2. CONFIRM CABLES TYPES WITH SYSTEM VENDORS PRIOR TO INSTALLATION. Sheet # of__ sheets Job Number 1433 Microfile Number K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 —N | T _ iI r= _ _ \ || : So COOLER : a wine : | [Ey] Kt HWh | | mine leas 0 || — mHhb T i Jo Tl th tHE / FREEZER : L in ae: ; (a) _ _ fal ror at fal_| ll] |. | | | | P1-1,3,5 DISCONNECT SWITCH — ~| | DOUN TO EVAP. UNIT (3A, 208V, 3P, NEMA 3R, 2 [CONT'D ON DUG E3:! ) NON-FUSIBLE) “\— DELI COOLER COND. UNIT Cus! a, (IBA, 208V, 3¢) P1-Il, 13, 15 ae DOUN TO EVAP. UNIT \ CONT'D ON DUG E31 | "3 DEL! FREEZER COND. UNIT CU-2 (29A, 208V, 34) DISCONNECT SWITCH (OA, 208V, 3P,NEMA3R, 1 NON-FUSIBLE? ry | } we | x an | \ DOUN TO GRAB 1 GO CASE. ~ || MEAT COQLER COND. uNiT Cul3 INTERCEPT/EXISTING GRAB 1 (2G, 208V, 34) 4 GO CASE|CONDUIT 4 ROUTE > : | NEW CABLES TONEWGRAB Lt : (is eesceell P1-21, 23, 25 | cs, £GO CASE! | DOUN TO EVAP. UNIT \ CONT E3) "ld Ua fl _ _ _ _ _ /* Fld LI 1.33-35-31- _ af —|— —_ —__ Sy | om a zh = = = (- DISCONNECT SWITCH — : \)\. (30A, 208V, 3P, NEMA 38 ~w-F \ . NON-FUSIBLE) ~ DISCONNECT SWITCH GRAB ¢ GO COND. UNIT cu-4 \ (30A, 208V, 3P,NEMA 3R, | (1.1A, 208V, 34) i ( NON-FUSIBLE) ALTERNATE * 3 | | | | | (c)— _ _ Ey EV Ty ay ELT = Ey =| TRUE PROJECT NORTH NORTH Scale: 1/8" = 1'-0" AP R V ' D BY DE S C R I P T I O N DA T E RE V il i a m s Ar c h i t e c t US G B C AA A A A P O Bo x 30 2 6 4 , Be l l i n g h a m , WA 98 2 2 6 - 4 3 7 7 W ~ Ph o n e / F a x 36 0 - 7 3 3 - 2 5 6 1 em a i l - ji m n i l i a m s | 5 @ c o m c a s t . n e t PO R T TO W N S E N D FO O D CO - O P RE N O V A T I O N & EX P A N S I O N AP R . 11 , 20 1 1 Da t e Ap p r o v e d by ST V EL E C T R I C A L - RO O F PL A N Dr a w n by KL E2.5 Sheet # of____s sheets Job Number 1433 Microfile Number EXISTING PANEL Pé — ULLLA EXISTING PANEL P5 | EXISTING MAIN SWITCHBOARD (| ee ZA -— EXISTING RANGE/OVEN EXISTING OVEN (288A, 20BV, 34) “oe [| K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 EVAPORATOR COIL (23A, lI5V, 16) 3" PVC (4 * 3/0 AUG +1* 1D AWG GND) EXISTING PANEL P& ate) Exi$ri is LDR REFRIGE ‘-+-, (18 ANISV, |, RELOCAT Y TSS EXISTING U/C_ REFRIGERATOR i A 3.344, lI5v, 16, RELOCATE) he in WW ry Bose Bee EXISTING DISHWASHER invA) (I2A, Il5v, 16) <——_— EXI6TING OUTLETS HY § SUPPORT RACK (RELOCATE) anne / | _©& r— EXISTING SLICER = | w (4BA, IIbV, Je) 4 1 eh h ti g t t &S > N +} iS ) Sa n ~X<] | ON , co r c c r e c s m o n c a r e s ah Sessa. \ \ \ x. EXISTING SCALE J Leet WRAPPER >._ “ XISTING PANEL F2 | 2 = EXISTING 2 DRI REFRIGERATOR "| (3A, lI5V, I¢, RELOCATE) (AA, IIBV, |, RELOCATE) 7+ $ Na ee (OBA, IIBV, 16, REMOVE) EXISTING 2" PVC (REMOVE —— ! 4°12 AWG + 1°12 AWG GND) as a. Fo=yaar4 fo \ Xt | 4 \ Xo \ tb A ibib SL MI ; => | ] cq Pa aan EXISTING 2 DRI REFRIGERATOR #2 tt / 1 \ (IOGA, IIBV, |e, RELOCATE) EXISTING MEAT GRINDER it / an a (5A, IIBV, 16, RELOCATE) —— i | Wo \ N44 nou A-4 | : st Vv : a ial i | L_ EXISTING PANEL LI a pene PANEL P3 Scale: 1/4” = 1'-0" TRUE PROJECT NORTH NORTH AP R V ' D BY DE S C R I P T I O N DA T E RE V il i a m s Ar c h i t e c t US G B C A A A A A W ~ P O Bo x 30 2 6 4 , Be l l i n g h a m , WA 98 2 2 6 - 4 3 7 7 36 0 - 7 3 3 - 2 5 8 1 em a i l - j m n i l l i a m s | 5 @ c o m c a s t ne t Ph o n e / F a x SSAA AV ! WRGY SA Pm : PROVIDE CONDULETS —e |. ft SEAL WALL WATERTIGHT 4-=|=5-==¥= ULLLLZA R | aiee———-s a FS P1-1, I1, o<« Ht PANEL P1 Re P ! NS DELI COOLER ! EXISTING ——>N EXISTING MAIN PANEL PS T | SUITCHBOARD rl 1 I U la = POWER / $$ _____———§}+—__+- MECH. DOOR HEATER (18OW, 2OV, 14) —_— ! , i ={- DRAINLINE HEATER d i TEN (iBow, Rov, 9 Ail= Ip] it Ey AT | — DELI FREEZER | = a 88, 268v,¥) ! P1-18, 20 = | HEATED VENT “5 = ) : = | —/EXISTING RANGE/OVEN Ae Ne, 0? = I = | EXISTING OVEN. = ; - - - (28BA, 20BV, 34) = = ma —— : | L— FUTURE HEATED HOLDING CABINET | : (204, IIBVAle) : EXISTING | DR REFRIGERATOR : (184, IIBV, le, RELOCATED) : UP TO COOLER ROOFTOP UNIT : 7 | a CONT'D ON DRAWING E25 | EXISTING DISHWASHER —1—> = | (12A, lIBV, 16) : _ | 3 1 : [E23 . : ' O EXISTING OUTLETS GRAB 4 syaleente 5 | | UP TO FREEZER ROOFTOP UNIT : 20 ‘ SUPPORT RACK Qo (BAVA, 230/l20V, |, REPLACES : LIQUIDTIGHT FLEX ——& (RELOCATED) i CONT'D ON DRAWING E2.5 EMETNE ETENCEM SINE (4°12 AUG +1" 12 | POWER CONNECTION TO NEW : AWG GND) , LOCATION AS REQUIRED) Sena \\ ————— EX : tga \4— EXISTING SLICER == 10 | : (ABA, lIBV. 1b) | STING WC REFRIGERATOR ‘\ |G | IIBV, |, RELOCATED) & = \ E EXISTING 2" PVC (PROVIDE NEW—® . E COORDINATE ALL OUTLET TT 4°02 Alia + 1°12 All GND) ty HEIGHTS WITH KITCHEN EQUIP. I E P1-21, 29, 31 r— EXISTING MEAT Gh SUPPLIER SUBMITTALS NEW/ELECTRICAL STUB-UP AREA : iN (B5A, lIBV\ 1, REL (VERIFY WITH CUT SHEET FOR = ; | \ }— HOBART A200|MIXER - LOCA 4 VOLTAGE) y Z # (4% HP, IlSv, le) ™ a q| Gn EX yo Nag age : iy | | O v i = | = 2-35, 37 ik EXISTING 2 DRIREFRIGERATOR *2 Dt : (1OSA, IIBV, Ie, NEWLOCATION #3 — nial OO \ \em esis 2e4, IBV, Ie, N) ALTERNATE 3 DRAINLINE HEATER —~ if i - \ Ext | (180, 120v, |) iG ) - \ — =e} EAT : EVAPORATOR COIL > co aint (OBA & IO5A, 208v, |e) a | | | XISTING PANEL P? COORDINATE ALL OUTLET S| | HEIGHTS WITH KITCHEN EQUIP. . | ITT . a : SUPPLIER SUBMITTALS dt p3-49,42 Let may EXISTING WRAPPER L__ EXISTING SCALE = | — EXISTING PANEL LI [ (4A, IBV, It, RELOCATER) (3A, lIBV, I, RELOCATED)\ — EXISTING PANEL P3 "= _UP TO ROOFTOP UNIT IN CONT'D ON DRAWING E2 | rl _DETAIL - ELECTRICAL ROOM/KITCHEN PLAN _ Scale: 1/4" = 1'-0" TRUE PROJECT NORTH NORTH PO R T TO W N S E N D FO O D CO - O P RE N O V A T I O N & EX P A N S I O N AP R . 11 , 20 1 1 Da t e Ap p r o v e d by ST V EL E C T R I C A L - DE T A I L S Dr a w n by KL E3. Sheet # 1 of sheets Job Number 1433 Microfile Number ; EXISTING I'4" EMT (4 "6 AWG +1* 8 AWG GND) v EXISTING * TO BLDG. STEEL & METALLIC PIPING 3/0 AWG GND 24" EMT (4° 3/0 AWG [ 1*@ AWG GND) v K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 AP R V ' D BY DE S C R I P T I O N DA T E RE V W il i a m s Ar c h i t e c t US G B C A A A A A P O Bo x 30 2 6 4 , Be l l i n g h a m , WA 98 2 2 6 - 4 3 7 7 + Ph o n e / F a x 36 0 - 7 3 3 - 2 5 8 ) em a i l - il i a m s | 5 @ c o m c a s t . n e t pt w PO R T TO W N S E N D FO O D CO - O P RE N O V A T I O N & EX P A N S I O N PO W E R SY S T E M RI S E R DI A G R A M & PA N E L SC H E D U L E S EL E C T R I C A L Da t e AP R . 11 , 20 1 1 Ap p r o v e d by ST V Dr a w n by KL EXIST. EXIST, exist) | Exist. EXIgT, Se EXIgT. PANEL| | EXIST. PANEL PANEL PANEL| |PANEL PANEL ee PANEL P1 ||PANEL PANEL P4A P4 Ll P3 P2 O Pe rae) B ++— EXISTING 22" PVC (4 * 250 KCMIL,— Fait AL +1" 4 AWG, AL GND) L * | AWG GND ( L L | ey 3 F a 4 Y) — EXISTING 244" PVC (4 * 250 KCMIL, = AL +1 "4 AWG, AL GND) 3 ( TO PSE PADMOUNTED 7 TRANSFORMER — EXISTING 3" PVC (4 "500 KCMIL, AL) Y— EXISTING 3° PVC (CO. SPARE) <——— GROUND RODS —————>} (SPACED @ I0'0' OC.) — 3" PVC (4 * 3/0 AWG +1* I/O AWG GND) ELECTRICAL - POWER SYSTEM RISER DIAGRAM NO SCALE EXISTING MAIN DISTRIBUTION SWITCHBOARD ELECTRICAL ROOM EXISTING PANEL P2 KITCHEN HALL EXISTING PANEL L1 (LIGHTING PANEL FOR ENTIRE STORE) PRODUCE VOLTAGE: 208Y/120V, 3 PH, 4W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND VOLTAGE: —_208Y/120V, 3 PH, 4W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND VOLTAGE: 208Y/120V, 3 PH, 4W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND TYPE: SWITCHBOARD BOLT-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL |FACTOR |LOAD (VA) TYPE: LOAD CENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL |FACTOR |LOAD (VA) TYPE: LOAD CENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL |FACTOR |LOAD (VA) SIEMENS FULL AIC RATING: 65,000 A |Lighting 1329.0| 1329.0 1.25] 1661.3 SIEMENS, B SERIES FULL AIC RATING: 10,000 A ILighting 488.0 0.0 488.0 1.25 610.0 SIEMENS, B SERIES FULL AIC RATING: 10,000 A |Lighting 15600.0/ 1329.0] 16929.0 1.25] 21161.3 ENCLOSURE: NEMA 1 SERIES AIC RATING: NONE |Gen. Purpose Outlets (First 10 KVA) 360.0 360.0 1.00 360.0 ENCLOSURE: NEMA 1 SERIES AIC RATING: NONE |Gen. Purpose Outlets (First 10 KVA) 0.0 180.0 180.0 1.00 180.0 ENCLOSURE: NEMA 1 SERIES AIC RATING: NONE |Gen. Purpose Outlets (First 10 KVA) 0.0 0.0 0.0 1.00 0.0 MOUNTING: SURFACE/FLOOR Gen. Purpose Outlets (Remainder) 0.0 0.0 0.50 0.0 MOUNTING: FLUSH Gen. Purpose Outlets (Remainder) 0.0 0.0 0.0 0.50 0.0 MOUNTING: — FLUSH Gen. Purpose Outlets (Remainder) 0.0 0.0 0.0 0.50 0.0 SPECIAL PROVISIONS: Special Purpose Outlets 540.0 540.0 1.00 540.0 SPECIAL PROVISIONS: Special Purpose Outlets 3600.0 0.0} 3600.0 1.00] 3600.0 SPECIAL PROVISIONS: Special Purpose Outlets 0.0 0.0 0.0 1.00 0.0 BUSSING: MANUFACTURER'S STANDARD Mechanical Equipment 35937.6 | 35937.6 1.00] 35937.6 BUSSING: MANUFACTURER'S STANDARD Mechanical Equipment 3047.0 0.0} 3047.0 1.00] 3047.0 BUSSING: MANUFACTURER'S STANDARD Mechanical Equipment 0.0 0.0 0.0 1.00 0.0 CONTINUOUS RATING1200 A MASTER NAMEPLATE Kitchen Equipment & Appliances 1127.0} 1127.0 0.65 732.6 CONTINUOUS RATING: 200 A MASTER NAMEPLATE Kitchen Equipment & Appliances 42681.1 1127.0| 43808.1 0.65 | 28475.2 CONTINUOUS RATING: 200 A MASTER NAMEPLATE Kitchen Equipment & Appliances 0.0 0.0 0.0 0.80 0.0 FULL AIC RATING: 65,000 A Miscellaneous 360.0 360.0 1.00 360.0 FULL AIC RATING: 10,000 A Miscellaneous 0.0 0.0 0.0 1.00 0.0 FULL AIC RATING: 10,000 A Miscellaneous 0.0 0.0 0.0 1.00 0.0 SERIES AIC RATING: NONE GROUND BAR 25% Largest Motor 0.0 SERIES AIC RATING: NONE GROUND BAR 25% Largest Motor 281.8 SERIES AIC RATING: NONE GROUND BAR 25% Largest Motor 0.0 MAIN: LUGS ONLY SUITABLE FOR USE AS SERVICE MAIN: LUGS ONLY CIRCUIT BREAKERS SHALL BE MAIN: LUGS ONLY CIRCUIT BREAKERS SHALL BE LOCATION: LEFT SECTION ENTRANCE EQUIPMENT LOCATION: BOTTOM EQUIPPED WITH LOCKING HARDWARE LOCATION: TOP EQUIPPED WITH LOCKING HARDWARE : Existing Load per 8-3-09 PSE Billing 99733.3 99733.3 1.25 | 124666.7 TOTAL LOAD 49816.1 1307.0] 51123.1 36194.0 TOTAL LOAD 15600.0| 1329.0] 16929.0 21161.3 SERVICE CONDUCTORS ARE ONLY |History = 89.76 KW @ 0.9 P.F. TOTAL AMPS 138.3 3.6 141.9 100.5 TOTAL AMPS 43.3 3.7 47.0 58.7 RATED FOR 760 AMPS TOTAL LOAD 99733.3 | 39653.6 | 139386.9 164258.1 TOTAL AMPS 276.8 110.1 386.9 455.9 CONN. FEEDER/BRANCH CIRCUIT BKR | CKT| BUS | CKT| BKR FEEDER/BRANCH CIRCUIT CONN. CONN. FEEDER/BRANCH CIRCUIT BKR | CKT] BUS |CKT | BKR FEEDER/BRANCH CIRCUIT CONN. LOAD (VA) DESCRIPTION NOTE | AMP/P | NO | (PHASE) | NO | AMP/P DESCRIPTION NOTE ILOAD (VA) LOAD (VA) DESCRIPTION NOTE | AMP/P | NO | (PHASE) | NO | AMP/P DESCRIPTION NOTE |LOAD (VA) MAIN SECTIONS (LEFT) 1380.0 [DISHWASHER & HOOD FAN (1) | 20/1 1 | A 2 20/1 |PIE COOLER/ DELI COUNTER SHELVES LIGHTS 844.0 0.0 [SPARE (FORMERLY REFER REACH-IN #4 (E15)) (2) -| 20/1 3 B 4 | 20/1 [OUTLETS - DELI SALES 900.0 MAIN LUGS 1219.0 [REACH-IN #2 (E18) 20/1 5 c| 6 | 20/1 [OUTLETS - DELI SALES 900.0 C.T. COMPARTMENT 2184.0 [COFFEE BREWER 30/2 | 7 |A 8 | 20/1 [DELI SERVICE CASE LIGHTS, CHEESE CASE FANS & LIG| 1204.0 1440.0 [FLOOR LIGHTING 2-5 GANG BOXES 20/1 1 TA 2 | 20/1 |BACK OFFICE LIGHTING + 1 EMERGENCY FLUOR. FIXT.| 1746.0 (PER PUGET SOUND ENERGY REQUIREMENTS) 2184.0 | 9 B 10 | 20/1 [DELI SERVICE CASE FANS 960.0 1440.0 [FLOOR LIGHTING 2-5 GANG BOXES 20/1 3 B 4 | 20/1 |DELI LIGHTS 1440.0 1127.0 [RANGE HOOD FAN 20/1 | 11 c | 12 | 20/1 {DELI CASE OUTLETS (GFCI ON CASE) 540.0 0.0 [SPACE 5 c| 6 | 20 |LTG- DELI COOLER/FREEZERS, MEAT RM COOLE (1) 783.0 1440.0 [SOUP POT 201 | 13 | A 14 | 20/1 [OUTLETS - KITCHEN SOUTH WALL, CHEESE REACH IN # 900.0 1440.0 |FLOOR LIGHTING 2-5 GANG BOXES 20/1 7 |A 8 SPACE 0.0 1440.0 [SOUP POT 20/1 | 15 B 16 | 20/1 |SOUP WARMERS 1440.0 1440.0 [FLOOR LIGHTING 2-5 GANG BOXES 20/1 9 B 10 SPACE 0.0 1440.0 [SOUP POT 20/1 | 17 c{ 18 | 20/1 |SOUP WARMERS 1440.0 1440.0 [FLOOR LIGHTING 2-5 GANG BOXES 20/1 | 11 cl 12 SPACE 0.0 MAIN LUGS 600.0 [OUTLET - JUICER 201 | 19 | A 20 | 20/1 [OUTLETS - KITCHEN ISLAND 180.0 1440.0 [EMERGENCY LIGHTING CIRCUIT 15/1 | 13 | A 14 SPACE 0.0 600.0 [OUTLET - JUICER 20/1 | 21 B 22 | 20/1 [OUTLETS - KITCHEN ISLAND 180.0 1440.0 [SPARE CIRCUIT TO 5G BOXES 20/1 | 15 B 16 SPACE 0.0 600.0 JOUTLET - JUICER 20/1 | 23 cl 24 SPACE 0.0 1440.0 [FRONT OFFICE LIGHTING 20/1 | 17 cl 18 SPACE 0.0 DISTRIBUTION SECTION (RIGHT) 2184.0 [PINNINI GRILL 20/2 | 25 | A 26 | 20/1 |SOUP WARMERS 1440.0 1440.0 [FLOOR LIGHTING 2-5 GANG BOXES 20/1 | 19 | A 20 SPACE 0.0 CONN. FEEDER/BRANCH CIRCUIT BKR |CKT] BUS |CKT] BKR FEEDER/BRANCH CIRCUIT CONN. 2184.0 | 27 B 28 | 20/3 |CONVECTION OVEN 1801.3 0.0 [SPACE 21 B 22 SPACE 0.0 LOAD (VA) DESCRIPTION Nowe | AMP/P | NO | (PHASE) | NO | AMP/P DESCRIPTION NOTE |LOAD (VA) 1200.0 [CHEESE TABLE 20/1 | 29 c [30 | 1801.3 0.0 [SPACE 23 c [24 SPACE 0.0 0.0 [SPACE FOR FUTURE USE 1 [A 2 SPACE FOR FUTURE USE 0.0 0.0 [SPARE 15/1 | 31 | A 32 | 1801.3 0.0 [SPACE 25 | A 26 SPACE 0.0 0.0 | B | 0.0 1200.0 JUICE BAR PREP REFER, SANDWICH BAR FREEZER 20/1 | 33 B 34 | 40/3 [CONVECTION OVEN 3458.6 0.0 [SPACE 27 B 28 SPACE 0.0 0.0 | cl | 0.0 1127.0 [MIXER - KITCHEN WEST WALL () | 20/1 | 35 cl] 36 | 3458.6 0.0 [SPACE 29 c | 30 SPACE 0.0 0.0 [SPACE FOR FUTURE USE 3 1A 4 SPACE FOR FUTURE USE 0.0 PAAR A gia i6 DEN ER PARE WER ANAL onic ~| 37 | A 38 | 3458.6 0.0 [SPACE 31 1A 32 SPACE 0.0 0.0 | B | 0.0 343.2 |GRAB & GO CASE . . (2) | 15/2 f\ 39 B 40 | 20/1 |SOUP WARMER - DELI SHORT WALL 1440.0 0.0 [SPACE 33 B 34 SPACE 0.0 0.0 | cl} | 0.0 343.2 Lf 44 cl 42 SPACE 0.0 0.0 [SPACE 35 c| 36 SPACE 0.0 0.0 |SPACE FOR FUTURE USE 5 A 6 SPACE FOR FUTURE USE 0.0 o : Fad 0.0 ISPACE 37 | A 38 SPACE 0.0 0.0 | B | 0.0 ee oie eee MAIN LUGS 0.0 [SPACE 39 | B | 40 SPACE 0.0 0.0 | cl | 0.0 ALTERNATE * 3 0.0 [SPARE Dot 41 c [42 SPACE 0.0 0.0 [SPACE FOR FUTURE USE 7 1A 8 SPACE FOR FUTURE USE 0.0 0.0 | B | 0.0 OTES NOTES 0.0 | cl} | 0.0 ~REMQ) é W2P So o— — (1) PROVIDE NEW CIRCUIT AND CIRCUIT BREAKER IN EXISTING SPACE. 0.0 |SPACE FOR FUTURE USE 1 A 3 SPACE FOR FUTURE USE ie 2) REMOVE EXISTING CIRCUIT BREAKER, PROVIDE NEW CIRCUIT BREAKER AND RECONNECT EXISTING CIRCUIT. (2) ALL OTHER CIRCUITS ARE EXISTING TO REMAIN. a sf Oo ies et eye Se ee : - a. am 0.0 cl | 0.0 . 0.0 [SPACE FOR FUTURE USE i A 12 | 600/3 [PANEL A- BACK ROOM () | 134116 (SE STEN Reese nNe Ve ewAly EXISTING PANEL P4 PRODUCE 00 | B | | 10351.4 VOLTAGE: 208Y/120V, 3 PH, 4W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND 0.0 | cl | l 12671.6 EXISTING PANEL P3 KITCHEN HALL TYPE: LOAD CENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW__| TOTAL |FACTOR |LOAD (VA) 17795.9 [PANEL P2 - KITCHEN HALL 200/3 | 13 | A 14 SPACE FOR FUTURE USE 0.0 VOLTAGE: 208Y/120V, 3 PH, 4 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND SIEMENS, B SERIES FULL AIC RATING: 10,000 A Lighting 0.0 0.0 0.0 1.25 0.0 18131.1 | | B | 0.0 TYPE: LOAD CENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL |FACTOR |LOAD (VA) ENCLOSURE: NEMA 1 SERIES AIC RATING: NONE |Gen. Purpose Outlets (First 10 KVA) 0.0 0.0 0.0 1.00 0.0 15196.1 | | cl} | 0.0 SIEMENS, B SERIES FULL AIC RATING: 10,000 A Lighting 16483.0| 1329.0] 17812.0 1.25 | 22265.0 MOUNTING: FLUSH Gen. Purpose Outlets (Remainder) 0.0 0.0 0.0 0.50 0.0 15522.5 [PANEL P3 - KITCHEN HALL 200/3 | 15 | A 16 | 200/3 [PANEL P5 - ELECTRICAL ROOM NA ENCLOSURE: NEMA 1 SERIES AIC RATING: NONE |Gen. Purpose Outlets (First 10 KVA) 3240.0 0.0} 3240.0 1.00] 3240.0 SPECIAL PROVISIONS: Special Purpose Outlets 0.0 0.0 0.0 1.00 0.0 13699.0 | | B | N/A MOUNTING: FLUSH Gen. Purpose Outlets (Remainder) 0.0 0.0 0.0 0.50 0.0 BUSSING: MANUFACTURER'S STANDARD Mechanical Equipment 0.0 0.0 0.0 1.00 0.0 11619.0 | | cl | | N/A SPECIAL PROVISIONS: Special Purpose Outlets 3240.0 540.0| 3780.0 1.00] 3780.0 CONTINUOUS RATING: 200 A MASTER NAMEPLATE Kitchen Equipment & Appliances 0.0 0.0 0.0 0.80 0.0 N/AIPANEL P4 - PRODUCE 200/3 | 17 | A 18 | 200/3 [PANEL P6 - ELECTRICAL ROOM 19452.3 BUSSING: MANUFACTURER'S STANDARD Mechanical Equipment 7892.0} 2880.0] 10772.0 1.00} 10772.0 FULL AIC RATING: 10,000 A Miscellaneous 0.0 0.0 0.0 1.00 0.0 N/A | | B | | 18820.3 CONTINUOUS RATING: 200 A MASTER NAMEPLATE Kitchen Equipment & Appliances 4036.5 0.0} 4036.5 0.90] 3632.9 SERIES AIC RATING: NONE GROUND BAR 25% Largest Motor 0.0 N/A | | cl] | | 17440.3 FULL AIC RATING: 10,000 A Miscellaneous 4200.0 0.0} 1200.0 1.00] 1200.0 SERIES AIC RATING: NONE GROUND BAR 25% Largest Motor 244.4 MAIN: LUGS ONLY CIRCUIT BREAKERS SHALL BE NOTES LOCATION: TOP EQUIPPED WITH LOCKING HARDWARE (1) PROVIDE NEW CIRCUIT & CIRCUIT BREAKER, MOUNTING HARDWARE, CONNECTION TO BUS, COVER PLATES, ETC., INEXISTING SPACE. MAIN: LUGS ONLY CIRCUIT BREAKERS SHALL BE TOTAL LOAD 0.0 0.0 0.0 0.0 (2) ALL OTHER CIRCUITS ARE EXISTING TO REMAIN. LOCATION: BOTTOM EQUIPPED WITH LOCKING HARDWARE TOTAL AMPS 0.0 0.0 0.0 0.0 TOTAL LOAD 36091.5] 4749.0] 40840.5 45134.2 TOTAL AMPS 100.2 13.2 113.4 125.3 CONN. FEEDER/BRANCH CIRCUIT BKR |CKT| BUS |CKT| BKR FEEDER/BRANCH CIRCUIT CONN. NEW PANEL A ELECTRICAL ROOM LOAD (VA) DESCRIPTION Nove | AMP/P | NO | (PHASE) | NO | AMP/P DESCRIPTION NOTE |LOAD (VA) VOLTAGE: 208Y/120V, 3 PH, 4W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND Sa SESoERGRARGnGISGUT a cer aus tea) oe ==5=s ERC neUT Sout TYPE: PANELBOARD PLUG-ON CIRCUIT BREAKERS ___ CALCULATION EXIST. NEW TOTAL |FACTOR |LOAD (VA) LOAD (VA) DESCRIPTION wot | aMP/P| NO | (PHASE)! NO | AMPIP DESCRIPTION nore |LOAD (VA) MAIN LUGS ENCLOSURE: NEMA 1 FULL AIC RATING: 42,000 A |Lighting 0.0 0.0 0.0 1.25 0.0 600.0 [DAIRY WALICIN LIGHTS 50/1 + TA : SPACE 0.0 MOUNTING: SURFACE SERIES AIC RATING: NONE jGen. Purpose Outlets (First 10 KVA) 0.0 180.0 180.0 1.00 180.0 960.0 IDAIRY WALK-IN FANS 20/1 3 B 4 20/1 OUTLETS - COMPUTERS BACK OFFICES POS/KITCHEN 1080.0 0.0 |OUTLETS - PRODUCE AREA COMPUTERS 20/1 4 A 2 20/1 |24' PRODUCE CASE FANS & LIGHTS 0.0 Gen. Purpose Outlets (Remainder) 0.0 0.0 0.0 0.50 0.0 100.0 IDAIRY WALK-IN DOOR HEATERS 20/1 5 cl 6 | 20/1 [OUTLETS - COMPUTERS BACK OFFICES 1080.0 0.0 [MEAT AND SEAFOOD CASE BLOWERS & LIGHTS 20/1 3 B 4 | 20/1 [24 PRODUCE CASE MISTING SYSTEM 0.0 CONTINUOUS RATING: 600 A Mechanical Equipment 0.0 33057.6 33057.6 1.00 33057.6 1080.0 |OUTLETS - SINK WALL 20/1 9 B 10 | 0.0 |WALK-IN FREEZER DOOR HEATERS + FRAME HEATERS 20/1 7 A 8 20/1 PEANUT GRINDER 0.0 GROUND BAR 25% Largest Motor il 1456.0 [HEATERS - BACK OFFICE, BREAKROOM, BATH 20/2 | 15 B 16 | 20/1 |REZINORE HEATER, EXHAUST FAN, BATH LIGHT 0.0 [PRODUCE WALK-IN COOLER LIGHTS & FANS 201 | 13 | A 14 | 20/1 [OUTLET - CHECKSTAND 2 0.0 MAIN: LUGS ONLY 1456.0 | 17 cl 8 THUNDER HEATER BACK WAELIGRO.D 0.0 |COFFEE GRINDER OUTLET, 2.5 GAL. WATER HEATER | 20/1 | 15 B 16 | 20/1 [OUTLET - CHECKSTAND 3 0.0 LOCATION: BOTTOM CIRCUIT BREAKERS SHALL BE 1500.0 [HOT WATER HEATER - STAFF 01 | 419 1A 20 ~|MAND DRYER - FRONT MENS BATHROOM (1) 0.0 [COFFEE GRINDER OUTLET, SCALES 20/1 | 17 c| 18 | 20/1 [OUTLET - CHECKSTAND 4 0.0 EQUIPPED WITH LOCKING HARDWARE 61.0 [EXIT LIGHT 2011 | 24 B 22 \ FRONT WOMENS BATHROOM (1) 0.0 [OUTLETS - N. & S. EXTERIOR, VENDOR BY PRODUCE SII 20/1 19 | A 20 | 20/1 [OUTLETS - CUSTOMER SERVICE COUNTER 0.0 TOTAL LOAD 3197.0 | 33237.6 | 36434.6 35731.3 960.0 [DAIRY WALKIN FANS (CENTER UNIT) 01 | 23 cl 24 PACE iin tein / 0.0 JOUTLET - ROOF 20/1 | 214 B 22 | 20/1 [OUTLETS - FRONT OFFICE 0.0 TOTAL AMPS 8.9 92.3 101.1 99.2 0.0 ISPARE 30/2 | 25 1 A 6 SPACE atti eee) 0.0 [WALK-IN FREEZER LTS. / BASEBOARD HEAT - FRONT 8 2@20/1| 23 c {24 | 20/1 |PRODUCE ISLAND FANS & BLOWERS 0.0 0.0 | 27 B 38 SPACE 0.0 0.0 [BASEBOARD HEAT - FRONT END / SALAD CASE 2@20/1{ 25 | A 26 | 60/3 |SUB PANEL - OUTSIDE COLD SHED, SHOP, TRUCK 0.0 CONN. FEEDER/BRANCH CIRCUIT BKR | CKT BUS CKT | BKR FEEDER/BRANCH CIRCUIT CONN. 1000.0 IMIGROWAVE - BAGK HALL 20/2 29 cl 30 SPACE 0.0 0.0 [OUTLETS - 24' + 12’ PRODUCE CASE END CAPS 20/1 27 B 28 | 0.0 LOAD (VA) DESCRIPTION NOTE | AMP/P| NO | (PHASE) | NO | AMP/P DESCRIPTION NOTE ILOAD (VA) 4219.0 |FRIDGE - BACK HALL a1 A 30 SPACE 00 0.0 OUTLETS - AISLE KICK PLATES, SMALL REFRIGERATOR! 20/1 | 29 c | 30 | 00 0.0 [SPARE 2007/3 | 1 =| A 2_| 30/3 {FUTURE SURGE ARRESTOR 0.0 0.0 [SPACE 33 B 34 SPACE 0.0 0.0 [MOTORIZED ENTRY DOORS 201 | 31 | A 32 | 30/2 [LARGE COLUMBIA GORGE FRIDGE 0.0 0.0 | 3 B 4 | 0.0 0.0 [SPACE 35 c | 36 | 20/1 [OUTLETS - MEAT ROOM (1) 360.0 0.0 [OUTLETS - FRONT WALL 20/1 | 33 B 34 | | 0.0 0.0 | 5 c| 6 | 0.0 0.0 [SPACE 37 | A 38 20/1. IMEAT GRINDER - MEAT ROOM (1) 977.5 0.0 |WATER PURIFIER 20/1 35 C| 36 20/1 |OUTLETS - VENDOR BY BARREL SINK 0.0 0.0 |SPARE 2003 | 7 | A 8 | 200/3 )PANEL P7 - ELECTRICAL ROOM 13411.6 0.0 SPACE 39 B 40 | 20/1 IOUTLET - MEAT ROOM (1) 180.0 0.0 [REMOTE COMPRESSOR FOR PRODUCE SALAD CASE 15/3 | 37 | A 38 | 20/1 [OUTLETS - VENDOR BY BARREL SINK 0.0 0.0 | 9 B to} | 10351.4 0.0 [SPACE 41 c [42 [20/1 |WRAPPER & SCALE - MEAT ROOM (1) 840.0 0.0 | 39 B 40_| 20/2 |HOT WATER HEATER - FRONT BATHROOMS 0.0 0.0 | 1 Cc | 12 | 12671.6 0.0 | 44 c[ 42 | 0.0 0.0 [SPACE FOR FUTURE 225/3 13 | A 14 SPACE FOR FUTURE 225/3 0.0 MAIN LUGS 0.0 15 B 16 0.0 — 0.0 17 cl] 18 0.0 (1) ALL CIRCUITS ARE EXISTING TO REMAIN. 0.0 [SPACE FOR FUTURE 225/3 19 | A 20 SPACE FOR FUTURE 225/3 0.0 NOTES Oe a e “ ze - (1) | PROVIDE NEW CIRCUIT AND CIRCUIT BREAKER IN EXISTING SPACE. ' 0.0 [SPACE FOR FUTURE 225/3 19 | A 20 SPACE FOR FUTURE 225/3 0.0 (2) ALL OTHER CIRCUITS ARE EXISTING TO REMAIN. ALTERNATE * | 0.0 21 B 22 0.0 0.0 23 c| 24 0.0 MAIN LUGS Sheet # E6.1 of sheets Job Number 433 Microfile Number ALTERNATE * 3 K ENGINEERS INC. 208 Third Street Lynden, WA. 98264 Bus. (360) 354-4757 FAX (360) 354-6794 LIGHTING FIXTURE SCHEDULE EXISTING PANEL P5 ELECTRICAL ROOM VOLTAGE: 208Y/120V, 3 PH, 4 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND TYPE: LOAD CENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL |FACTOR |LOAD (VA) SIEMENS, B SERIES FULL AIC RATING: 10,000 A jLighting 0.0 0.0 0.0 1.25 0.0 ENCLOSURE: NEMA 1 SERIES AIC RATING: NONE |Gen. Purpose Outlets (First 10 KVA) 0.0 0.0 0.0 1.00 0.0 MOUNTING: SURFACE Gen. Purpose Outlets (Remainder) 0.0 0.0 0.0 0.50 0.0 SPECIAL PROVISIONS: Special Purpose Outlets 0.0 0.0 0.0 1.00 0.0 BUSSING: MANUFACTURER'S STANDARD |Mechanical Equipment 0.0 0.0 0.0 1.00 0.0 CONTINUOUS RATING: 200 A MASTER NAMEPLATE Kitchen Equipment & Appliances 0.0 0.0 0.0 0.65 0.0 FULL AIC RATING: 10,000A Miscellaneous 0.0 0.0 0.0 1.00 0.0 SERIES AIC RATING: NONE GROUND BAR 25% Largest Motor 0.0 MAIN: LUGS ONLY CIRCUIT BREAKERS SHALL BE LOCATION: BOTTOM EQUIPPED WITH LOCKING HARDWARE TOTAL LOAD 0.0 0.0 0.0 0.0 TOTAL AMPS 0.0 0.0 0.0 0.0 CONN. FEEDER/BRANCH CIRCUIT BKR | CKT BUS CKT | BKR FEEDER/BRANCH CIRCUIT CONN. LOAD (VA) DESCRIPTION NOTE | AMP/P | NO | (PHASE) | NO | AMP/P DESCRIPTION NOTE |LOAD (VA) 0.0 |REFER CONDENSER 2AB - ROOFTOP 50/3 1 A 2 20/1 |OUTLETS - ROOFTOP 0.0 0.0 | 3 B 4 SPACE 0.0 0.0 | 5 Cc} 6 20/1 |LTG - PARKING LOT 0.0 0.0 |SPACE 7 A 8 125/3 |FREEZER CONDENSER 1AB - ROOFTOP 0.0 0.0 |SPACE 9 B 10 | 0.0 0.0 |SPACE 11 Cc} 12 | 0.0 0.0 |OUTLET - EXTERIOR GFI 20/1 13, | A 14 50/3 |REFER CONDENSER 4AB - ROOFTOP 0.0 0.0 JOUTLET - EXTERIOR GFI 20/1 15 B 16 | 0.0 0.0 |JAIR CONDITIONER - SERVER ROOM 20/1 17 Cc | 18 | 0.0 0.0 |SPACE 19 | A 20 50/3 |REFER CONDENSER 3AB - ROOFTOP 0.0 0.0 |SPACE 21 B 22 | 0.0 0.0 |SPACE 23 Cc} 24 | 0.0 0.0 |SPACE 25 | A 26 20/1 |LTG - ENTRY + CONTACTOR 0.0 0.0 |SPACE 27 B 28 20/1 |LTG - BUILDING EAVE 0.0 0.0 |SPACE 29 Cc} 30 20/1 |LTG - POST LIGHTS 0.0 0.0 |SPACE 31 [A 32 SPACE 0.0 0.0 |SPACE 33 B 34 SPACE 0.0 0.0 |SPACE 35 Cl} 36 SPACE 0.0 0.0 |SPACE 37 | A 38 SPACE 0.0 0.0 |SPACE 39 B 40 SPACE 0.0 0.0 |SPACE 41 Ci} 42 SPACE 0.0 MAIN LUGS NOTES (1) ALL CIRCUITS ARE EXISTING TO REMAIN. EXISTING PANEL P6 ELECTRICAL ROOM VOLTAGE: 208Y/120V, 3 PH, 4 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND TYPE: LOAD CENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL |FACTOR |LOAD (VA) SIEMENS, B SERIES FULL AIC RATING: 10,000 A jLighting 122.0 0.0 122.0 1.25 152.5 ENCLOSURE: NEMA 1 SERIES AIC RATING: NONE |Gen. Purpose Outlets (First 10 KVA) 900.0 0.0 900.0 1.00 900.0 MOUNTING: SURFACE Gen. Purpose Outlets (Remainder) 0.0 0.0 0.0 0.50 0.0 SPECIAL PROVISIONS: Special Purpose Outlets 1800.0 0.0 1800.0 1.00 1800.0 BUSSING: MANUFACTURER'S STANDARD Mechanical Equipment 52530.9 0.0} 52530.9 1.00] 52530.9 CONTINUOUS RATING: 200 A MASTER NAMEPLATE Kitchen Equipment & Appliances 0.0 0.0 0.0 0.65 0.0 FULL AIC RATING: 10,000A {Miscellaneous 0.0 360.0 360.0 1.00 360.0 SERIES AIC RATING: NONE GROUND BAR 25% Largest Motor 415.7 MAIN: LUGS ONLY CIRCUIT BREAKERS SHALL BE LOCATION: BOTTOM EQUIPPED WITH LOCKING HARDWARE TOTAL LOAD 55352.9 360.0 | 55712.9 56159.1 TOTAL AMPS 153.6 1.0 154.6 155.9 CONN. FEEDER/BRANCH CIRCUIT BKR | CKT BUS CKT | BKR FEEDER/BRANCH CIRCUIT CONN. LOAD (VA) DESCRIPTION Nove | AMP/P | NO | (PHASE) | NO | AMP/P DESCRIPTION NOTE |LOAD (VA) 3482.6 |AC-1 - ROOF HEATING UNIT 40/3 1 A 2 40/3 |AC-2 - ROOF HEATING UNIT 3482.6 3482.6 | 3 B 4 | 3482.6 3482.6 | 5 Cc} 6 | 3482.6 3482.6 |AC-3 - ROOF HEATING UNIT 40/3 7 IA 8 40/3 |AC-4 - ROOF HEATING UNIT 3482.6 3482.6 | 9 B 10 | 3482.6 3482.6 | 11 Cc} 12 | 3482.6 2250.0 |HOT WATER HEATER H-1 30/2 13 | A 14 20/1 |LTG & OUTLETS - UTILITY ROOM 1022.0 2250.0 | 15 B 16 20/1 {OUTLETS - PHONE DATA SYSTEM 900.0 2250.0 |HOT WATER HEATER H-2 30/2 17 Cc} 18 20/1 |OUTLETS - PHONE DATA, FIRE ALARM & BOOSTER PAN 1260.0 2250.0 | 19 | A 20 SPACE 0.0 1740.0 [HOT WATER CIRC. PUMP + HOT WATER HEATER 15/1 21 B 22 SPACE 0.0 0.0 |FAN 20/1 23 C | 24 SPACE 0.0 0.0 |SPACE 25 | A 26 SPACE 0.0 0.0 |SPACE 27 B 28 SPACE 0.0 0.0 |SPACE 29 Cc | 30 SPACE 0.0 0.0 |SPACE 31} A 32 SPACE 0.0 0.0 |SPACE 33 B 34 SPACE 0.0 0.0 |SPACE 35 C| 36 SPACE 0.0 0.0 |SPACE 37 | A 38 SPACE 0.0 0.0 |SPACE 39 B 40 SPACE 0.0 0.0 |SPACE 41 Cc} 42 SPACE 0.0 MAIN LUGS NOTES (1) ALL CIRCUITS ARE EXISTING TO REMAIN. NEW PANEL P7 ELECTRICAL ROOM VOLTAGE: 208Y/120V, 3 PH, 4 W FEEDER/BRANCH CIRCUIT DEVICES: ELECTRICAL LOAD CONN. LOAD (VA) DEMAND | DEMAND TYPE: LOAD CENTER PLUG-ON CIRCUIT BREAKERS CALCULATION EXIST. NEW TOTAL |FACTOR |LOAD (VA) ENCLOSURE: NEMA 1 FULL AIC RATING: 10,000 A jLighting 0.0 0.0 0.0 1.25 0.0 MOUNTING: SURFACE SERIES AIC RATING: NONE /|Gen. Purpose Outlets (First 10 KVA) 0.0 180.0 180.0 1.00 180.0 Gen. Purpose Outlets (Remainder) 0.0 0.0 0.0 0.50 0.0 BUSSING: MANUFACTURER'S STANDARD |SPECIAL PROVISIONS: Special Purpose Outlets 0.0 0.0 0.0 1.00 0.0 CONTINUOUS RATING: 200 A Mechanical Equipment 0.0} 33057.6 | 33057.6 1.00 | 33057.6 FULL AIC RATING: 10,000A MASTER NAMEPLATE Kitchen Equipment & Appliances 3197.0 0.0 3197.0 0.65 2078.1 SERIES AIC RATING: NONE Miscellaneous 0.0 0.0 0.0 1.00 0.0 GROUND BAR 25% Largest Motor 415.7 MAIN: LUGS ONLY LOCATION: BOTTOM CIRCUIT BREAKERS SHALL BE EQUIPPED WITH LOCKING HARDWARE MULTIWIRE CIRCUITS SHALL HAVE [TOTAL LOAD 3197.0 | 33237.6 | 36434.6 35731.3 HANDLE TIES. TOTAL AMPS 8.9 92.3 101.1 99.2 CONN. FEEDER/BRANCH CIRCUIT BKR | CKT BUS CKT | BKR FEEDER/BRANCH CIRCUIT CONN. LOAD (VA) DESCRIPTION NOTE | AMP/P | NO | (PHASE) | NO | AMP/P DESCRIPTION NOTE |LOAD (VA) 1801.3 |DELI COOLER CONDENSING UNIT CU-1 - ROOFTOP 20/3 1 A 2 50/2 |SPARE 0.0 1801.3 | 3 B 4 | 0.0 1801.3 | 5 Cc} 6 40/2 |SPARE 0.0 973.5 |DELI COOLER EVAP., DELI FREEZER DOOR - BACK ROO|_15/1 7 |A 8 | 0.0 0.0 |SPARE 20/1 9 B 10 40/3 |SPARE 0.0 3482.6 |DELI FREEZER CONDENSING UNIT CU-2 - ROOFTOP 30/3 11 Cc} 12 | 0.0 3482.6 | 13 | A 14 | 0.0 3482.6 | 15 B 16 20/1 |OUTLET - COOLER AND FREEZER BACK ROOM 180.0 1783.2 {DELI FREEZER EVAPORATOR - DELI FREEZER 20/2 17 Cc | 18 20/1 |REFER REACH-IN 897.0 1783.2 | 19 | A 20 30/1 |FUTURE HEATED HOLDING CABINET 2300.0 1801.3 |MEAT COOLER CONDENSING UNIT CU-3 - ROOFTOP 20/3 21 B 22 20/1 |SPARE 0.0 1801.3 | 23 C| 24 20/1 |SPARE 0.0 1801.3 | 25 | A 26 20/1 |SPARE 0.0 2161.5 |MEAT COOLER EVAPORATOR - MEAT COOLER 20/2 27 B 28 20/1 |SPARE 0.0 1981.5 | 29 Cc | 30 20/1 |SPARE 0.0 HSA i ts, | 31) A 32 SPACE 0.0 924.7 |GRAB & GO CASE CONDENSING UNIT CU-4 - ROOFTOP | 20/3 33 B 34 SPACE 0.0 924.7 | ) 35 Cl} 36 SPACE 0.0 924.7 | [)37 | A 38 SPACE 0.0 LA__ SX. |SPACE AL__A_A_A_A_A_*_A_ T_T 9 B 40 SPACE 0.0 0.0 |SPACE 41 Ci} 42 SPACE 0.0 MAIN LUGS TYPE DESCRIPTION VOLTS MANUFACTURER & CAT. NO. LAMP(S) LOADS (OR APPROVED SUBSTITUTION) WATTS| VA A B |FLUORESCENT WRAPAROUND, SURFACE MTD (UNLESS 120 |COLUMBIA WCW4-332-E (2) F32T8/SP35 59 61 NOTED OTHERWISE), 2 LAMP, 4' LONG, SUITABLE FOR DAY BRITE CAW-332-2/21-EB101 (2) FO32/735 DAMP LOCATIONS, WITH 1 ELECTRONIC BALLAST & LIGHTOLIER WB4B-332-HI (2) F32T8/TL735 ACRYLIC PRISMATIC LENS LITHONIA 2LB-332-GEB10IS METALUX WS-332A-EB82 WILLIAMS 17-4-232-A-EBLH2-DL C_ |INCANDESCENT, 150W, WALL MTD, SUITABLE FOR WET 120 |(FURNISHED BY KITCHEN EQUIPMENT (1) 100A 100 100 LOCATIONS, WITH CAST ALUMINUM BODY, TEMPERED SUPPLIER, INSTALLED BY ELECTRICAL GLASS GLOBE & CAST ALUMINUM GUARD CONTRACTOR) D NOTES: 4. FLUORESCENT ELECTRONIC BALLASTS TOTAL HARMONIC DISTORTION (THD) SHALL NOT EXCEED 10%. 2. ALL FIXTURES WITH MULTIPLE BALLASTS SHALL BE MULTI-LEVEL SWITCHED. 3. LAMPS, WHERE AVAILABLE, SHALL PASS THE FEDERAL (EPA) TCLP TEST FOR HAZARDOUS WASTE DETERMINATION. 4. CONTRACTOR & LIGHTING FIXTURE SUPPLIER SHALL VERIFY DESCRIPTION, MOUNTING REQUIREMENTS, CATALOG NUMBERS, ETC. MATCH. ADVISE ENGINEER OF ANY CONFLICTS OR DESCREPANCIES. AP R V ' D BY DE S C R I P T I O N DA T E RE V VU © O Ol]. 2] 8 + M853 ® oN 8 pet YlLags < fa a8) a, ees SL 83: o g p< 8 AP R . 11 , 20 1 1 Da t e Ap p r o v e d by ST V PO R T TO W N S E N D FO O D CO - O P RE N O V A T I O N & EX P A N S I O N EL E C T R I C A L - PA N E L SC H E D U L E S & LI G H T I N G FI X T U R E SC H E D U L E Dr a w n by KL E6.2 Sheet # of sheets Job Number 1433 Microfile Number