g). A map showing the proposed provisions for storm drainage in-
cluding the location and approximate sizes of catch basins,
culverts and other drainage structures.
h). A map showing the proposed water distribution system and con-
nection to the municipal water system, or another plan in
lieu of a water distribution system plan.
i). A map showing the proposed sewage disposal system, including
profiles, and the connections to the municipal sewerage sys-
tom, or another plan in lieu of such a sewer system.
j). Where the proposed sewerage system of the proposed plat, sub-
division or dedication will not be connected to the municipal
sewage system the following information will be required in
order to provide the City Engineer and the City Planning Com-
mission with the information necessary for assuring that
adequate provisions will be made to prevent the proposed plat,
subdivision or dedication from becoming a health hazard:
A map showing the location of percolation tests and
a percolation rate log showing the results of each
test at every test hold. Percolation test holes must
be placed so that the resulting information gives a
true analysis of the percolation rate of the soil in
which the leaching portion of the sewage disposal
system will be placed; and a certificate of approval
from the Olympic Health District office.
k). A map showing the location of soil test pits, at least one
for each acre or block, in the proposed plat, subdivision or
dedication, and the logs of each test pit indicating the soil
types and the ground water table.
1� 1�