Loading...
HomeMy WebLinkAbout02398Square feet of aggregate Required number gross floor area of berths 40,000 to 59,999 1 60,00o to 99,999 2 100,00o to 160,000 3 each additional 60,000 1 additional Section 4.04 General Requirement, Fences and Greenbelts. Fences or hedges providing a maximum of six feet sight obstruction from adjacent properties may be built on the side and rear property lines, and across the front of the property line with the front of a building, but not closer to the street right-of-way than 20 feet. Corner lots must observe the 20-foot fence set -back on both streets. From the 20-foot fence set- back line to the street right-of-way, solid fences a maximum of three feet high, measured from the ground on which the fence stands, are permitted; open rail fences a maximum of four feet six inches in height are permitted where the rails and posts constitute not more than one-third of the fence area. Where fence heights greated than those contained herein are directed, the greater shall apply. A. Greenbelt or sight -obscuring constructions, where required by pro- visions in this Ordinance shall be of evergreen plantings, or climbing varieties of non -deciduous vines on permanently installed mesh or architectural fencing of such design and material that retains it attractiveness with nominal maintenance. B. Greenbelt, open -space preservation and/or landscaping shall be in keeping with local conditions and plant materials. There shall be proper maintenance and injurious or unsightly weeds, etc. will not be permitted. Section 4.05 General Requirements, Planned Unit Developments - Residential. The unified and planned development of a site, in single or corporate owner- ship at the time of development, may be permitted in a PUD Planned Development Overlay District without the customary division into individual lots, or without specific compliance to the district regulations as applicable to individual lots subject to the regulations as hereinafter provided in this section and as previously proveded in Section 3.4. A. Application of Regulations 1. In addition to the uses permitted in the underlying district any other use may be permitted as previously designated in Section 3.03 consistent with the criteria established in sub- paragraph "C" following 2. Individual uses and structures in a Planned Unit Development Project District need not comply with the specific building location, height, building size, floor area, lot size, and open space requirements of the underlying basic district provided that the spirit and intent of such requirements are complied with in the total development plan for such project consistent with the criteria as established in subparagraph Iv-6