superintendent may issue a special permit for installation of a
side sewer requiring compliance with said provisions insofar as
is reasonably possible, but such permit shall be isuued only upon
condition that the permitee execute and deliver to the City of
Port Townsend, an instrument, in form furnished by the superin-
tendent, agreeing to save harmless and indemnify the City of
Port Townsend from any damage or injury resulting from such sub-
standard installation, together with the fee of $1.50 to cover
the cost of the recording.
Section 6.26:
The point of connection to th,City's sewer
line of any side sewer serving any multiple -family dwelling shall
be as directed by the City Council of the City of Port Townsend.
ARTICLE VII
Pipe Materials
Section 7.01: The following pipe may be used between the
sewer main and the property line:
Cast iron - Federal Spec. 1,91-P-421 Cement Lined
Class 150
Concrete pipe - A S T M Spec. C-14-57 T
Vitrified Clay Pipe - A S T M Spec. C-200-57 T
Asbestos Cement Pipe - A S T M Spec. C-428-59 T
Class 2400
The concrete pipe shall be rubber gasket pipe using "Tylox,"
"Flex-Tite," "Press Seal" or other approved units. The clay
pipe joining shall be rubber or plastic conforming to A S T M
Specification C-425-58 T. The Asbestos Cement Pipe coupling
shall be "Ring Tite" or approved equal. The Cast Iron pipe shall
have mechanical joints or "o" ring rubber gasket joints Tyton or
equal.
Section 7.02: On all side sewers between the property line
and the building drain, the pipe and jointing shall bonform to
Section 7.01.
ARTICLE VIII
Illegal Connections
Section 8.01: It shall be unlawful to divert or cause to be