HomeMy WebLinkAbout09016City of Port Townsend Development Services Department
Notice
PERMIT NUMBER R E K dq -.— (0
OWNER
JOB LOCATION
Inspection of this structure has found the following
You are hereby notified that no more work shall be done upon these premises until
the above violations are corrected, unless noted otherw When corrections have
been made, call72//r inspection.
Datefb f Inspector i � c �. Lots
DSD Main Office (360) 379-5095 INSPECTION REQUEST (360) 385-2294
THIS NOTICE MUST BE KEPT WITH APPROVED PLANS ON SITE
QORTTCONSTRUCTION PROGRESS RECORD
CITY OF PORT TOWNSEND
Development Services Department
250 Madison Street, Suite 3, Port Townsend, WA 98368
POST THIS CARD IN A SAFE, CONSPICUOUS LOCATION. PLEASE DO NOT REMOVE THIS NOTICE UNTIL ALL REQUIRED INSPECTIONS ARE MADE AND SIGNED OFF
BY THE APPROPRIATE AUTHORITY AND THE BUILDING IS APPROVED FOR OCCUPANCY. STAMPED APPROVED PLANS MUST BE AVAILABLE ON THE JOBSITE.
PARCEL NO. 959700302 PERMIT NO. BLD09-016 ISSUED DATE 03/25/2009 EXPIRATION DATE 09/21/2009
ADDRESS 3410 CLIFF ST
OWNER WALKER SCOTT
CONSTRUCTION TYPE OCCUPANT LOAD
PROJECT DESCRIPTION Residence Addition
CONTRACTOR OWNER BUILDER LENDER
INSPECTION INSP DATE COMMENTS INSPECTION INSP DATE COMMENTS
SETBACKS SURVEY PINS
FOOTING
FOUNDATION WALL
FLOOR FRAMING
FRAMING
SHEAR WALL
INSULATION
SMOKE DETECTORS
GWB
ADDRESS NUMBERS
FINAL PUBLIC WORK
FINAL BUILDING
TO REQUEST AN INSPECTION CALL (360) 385-2294.
INSPECTION REQUESTS MUST BE RECEIVED PRIOR TO 3:00 PM FOR NEXT DAY INSPECTION.
Qoar ro
CITY OF PORT TOWNSEND
�o DEVELOPMENT SERVICES DEPARTMENT
�-INSPECTION REPORT
9� -
�WA CALL THE INSPECTION LINE AT 360-385-2294 BY 3:OOpm THE DAY BEFORE YOU
WANT THE INSPECTION. FOR MONDAY INSPECTION, CALL BY 3:OOOOPM FRIDAY.
DATE OF INSPECTION: `lD % PERMIT NUMBER: l�.p Q
SITE ADDRESS:
CONTACT PERSON:J, PHONE:
TYPE OF INSPECTION:/ �� �10 �-/ 14, j EjA—(--
❑ APPROVED ❑ APPROVED WITH ❑ NOT APPROVED
CORRECTIONS
Ok to proceed. Corrections will be Call for re -inspection before
checked at next inspection proceeding.
Inspector , C--Iz 7 Loyz, Date
Acknowledgement Date
Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may
be assessed if work is not ready for inspection.
PORT r0
CITY OF PORT TOWNSEND
�o DEVELOPMENT SERVICES DEPARTMENT
INSPECTION REPORT
9��wA CALL THE INSPECTION LINE AT 360-385-2294 BY 3:00pm THE DAY BEFORE YOU
WANT THE INSPECTION. FOR MONDAY INSPECTION, CALL BY3:OOPM FRIDAY.
Z
DATE OF INSPECTION: ,Q PERMIT NUMBER: I,71.h D9
( "— 0/6
SITE ADDRESS: 3 q to cLA Fr S ,
CONTACT PERSON: / PHONE:
TYPE OF INSPECTION: (A Z�- [ _ /� j L Aj
c \
❑ APPROVED ❑APPROVED WITH ❑ NOT APPROVED
CORRECTIONS
Ok to proceed. Corrections will be Call for re-inspection before
checked at next inspection proceeding.
Inspector Date p
Acknowledgement Date
Approved plans and permit card must be on-site and available at time of inspection. A re-inspection fee may
be assessed if work is not ready for inspection.
T,
�oF pORT T o�ym CITY OF PORT TOWNSEND
o DEVELOPMENT SERVICES DEPARTMENT
INSPECTION REPORT
WA CALL THE INSPECTION LINE AT 360-385-2294 BY 3:00pm THE DAY BEFORE YOU
WANT THE INiSPECTION. FOR MONDAY INSPECTION, CALL BY /3:OOPM FRIDAY.
DATE OF INSPECTION: 6/1'? PERMIT NUMBER:V
SITE ADDRESS: L+ /0
CONTACT PERSON: PHONE:
TYPE OF INSPECTION:
❑ APPROVED ❑ APPROVED WITH
CORRECTIONS
Ok to proceed. Corrections will be
=eked at next inspection
(
Inspector L � � t — 0 Date
Acknowledgement
Date
❑ NOT APPROVED
Call for re -inspection before
proceeding.
/ 7 O
Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may
be assessed if work is not ready for inspection.
Poor ro
CITY OF PORT TOWNSEND
o DEVELOPMENT SERVICES DEPARTMENT
INSPECTION REPORT
WASr�"' CALL THE INSPECTION LINE AT 360-385-2294 BY 3:00pm THE DAY BEFORE YOU
WANT THE I SPE TION. FOR MONDAY INSPECTION, CALL BY 3:OOPM FRIDAY.
DATE OF INSPECTION: PERMIT NUMBER: Lc�JZ�QJ C)
SITE ADDRESS: CL.j-F�
CONTACT PERSON: PHONE:
TYPE OF INSPECTION: *60 �r' NCD \� ! -j l� �_c ��� lJ � L Y�
❑ APPROVED
Inspector
Acknowledgement
❑ APPROVED WITH
CORRECTIONS
Ok to proceed. Corrections will be
checked at next inspection
/A I Lo C12— Date
Date
❑ NOT APPROVED
Call for re -inspection before
proceeding..
'
? /6 9
Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may
be assessed if work is not ready for inspection.
A
P.T. DESIGN & C < < Y
TIMBERFRAME Phone: (360) 379-3940
3265 Eddy Street E-mail: erickuzma@msn.com
Port Townsend, WA 98368
Scott Walker 3 December 2008
3410 Cliff Street
Port Townsend, WA 98368
GRAVITY LOADS:
1:
First Floor Joists:
2x10 @ 24"o.c. HF42
2:
Second Floor Joists:
2x6 @ 16"o.c. HF#2
3:
Existing Rim Joist (as Header):
2x12 HF42 (Adequate)
4:
Landing Edge Beam:
2x6 DF#2
5:
New Window Header @ Ridge:
4x8 DF#1
6:
Ridge Header @ old Ext. Wall:
6x6 DF#2
7:
New Existing Ridge Beam:
6.75x12 Glulam 24F -V4
8:
New Dormer Ridge:
(2) 2x6 HF#2
9:
Addition Ridge:
(2) 2x10 Select Struc.
10:
Typical Rafter:
2x10 HF#2 @ 24" o.c.
Y D E
04N"129 2009
CITY Of PORT TOWNSEND
DSD
Floor Joistf 2006 International Building Code (05 NDS)1 Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008: 4:00:43 PM
Project: WALKER - Location: IST FLOOR JOISTS
Summary:
1.5 IN x 9.25 IN x 7.58 FT (a)_ 24 O.C. / #2 - Hem -Fir - Dry Use
Section Adequate By: 142.6% Controlling Factor: Section Modulus / Depth Required 5.94 In
Center Span Deflections:
Dead Load:
Live Load:
Total Load:
Center Span Left End Reactions (Support A):
Live Load:
Dead Load:
Total Load:
Bearing Length Required (Beam only, support capacity not checked):
Center Span Right End Reactions (Support B):
Live Load:
Dead Load:
Total Load:
Bearing Length Required (Beam only, support capacity not checked):
Joist Data:
Center Span Length:
Floor sheathing applied to top of joists -top of joists fully braced.
Live Load Duration Factor:
Live Load Deflect. Criteria:
Total Load Deflect. Criteria:
Center Span Loading:
Uniform Floor Loading:
Live Load:
Dead Load:
Total Load:
Total Load Adjusted for Joist Spacing:
Properties For: #2- Hem -Fir
Bending Stress:
Shear Stress:
Modulus of Elasticity:
Adjusted Modulus of Elasticity:
Stress Perpendicular to Grain:
Adjusted Properties
Fb' (Tension):
Adjustment Factors: Cd=1.00 CF=1.10 Cr -1.15
FV:
DLD-Center= 0.01 IN
LLD -Center= 0.03 IN = U3196
TLD -Center- 0.04 IN = U2325
LL-Rxn-A= 303 LB
DL-Rxn-A= 114 LB
TL-Rxn-A= 417 LB
BL -A= 0.69 IN
LL-Rxn-B= 303 LB
DL-Rxn-B= 114 LB
TL-Rxn-B= 417 LB
BL -B= 0.69 IN
L2= 7.58 FT
Cd= 1.00
U 480
U 360
LL -2=
40.0
PSF
DL -2=
15.0
PSF
TL -2=
55.0
PSF
wT-2=
110
PLF
Fb=
850
PSI
Fv=
150
PSI
E=
1300000
PSI
E -Min=
470000
PSI
Fc -perp=
405
PSI
Fb'=
1075
PSI
FV=
150
PSI
Adjustment Factors: Cd=1.00
Design Requirements:
Controlling Moment:
M=
790
FT -LB
3.79 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads
on span(s) 2
Controlling Shear:
V=
334
LB
At a distance d from right support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on span(s) 2
Decking Information:
Plywood Thickness
T=
3/4
IN
Plywood is glued
Moment Of Inertia Calculations For Glued Floor:
Joist Area:
A-ioist=
13.88
IN2
Plywood Area:
A -ply=
3.00
IN2
Section Centroid:
C=
5.51
IN ABOVE BASE
Moment Of Inertia:
I -comb=
160.60
IN4
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq=
8.82
IN3
S=
21.39
IN3
Area (Shear):
Areq=
3.34
IN2
A=
13.88
IN2
Moment of Inertia (Deflection):
Ireq=
24.87
IN4
I -comb=
160.60
IN4
Floor Joist[ 2006 International Building Code (05 NDS) j Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: IST FLOOR JOISTS
Summary:
1.5 IN x 9.25 IN x 7.58 FT @ 24 O.C. / #2 - Hem -Fir - Dry Use
Section Adequate By: 142.6% Controlling Factor: Section Modulus / Depth Required 5.94 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
500
250
Shear
(lbs) 0
-250
-500
800
400
Moment
(ft -Ib) 0
-400
-800
-0.04
-0.02
Deflection
(in) 0
0.02
0.04
Controlling Load Cases:
Shear: Critical shear created by combining all dead loads and live loads on span(s) 2
Moment: Critical moment created by combining all dead loads and live loads on span(s) 2
Deflection: Critical deflection created by combining all dead loads and live loads on span(s) 2
LOADING DIAGRAM
Center Span = 7.58 ft
Floor Joist[ 2006 International Building Code (05 NDS)1 Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008: 4:00:40 PM
Proiect: WALKER - Location: 2ND FLOOR JOISTS
Summary:
1.5 IN x 5.5 IN x 7.54 FT A 16 O.C.1 #2 - Hem -Fir - Dry Use
Section Adequate By: 27.4% Controlling Factor: Moment of Inertia / Depth Required 5.07 In
Center Span Deflections:
Dead Load:
DLD-Center-
0.05
IN
Live Load:
LLD -Center-
0.14
IN = U631
Total Load:
TLD -Center=
0.20
IN = U459
Center Span Left End Reactions (Support A):
Live Load:
LL-Rxn-A=
201
LB
Dead Load:
DL-Rxn-A=
75
LB
Total Load:
TL-Rxn-A=
276
LB
Bearing Length Required (Beam only, support capacity not checked):
BL -A=
0.46
IN
Center Span Right End Reactions (Support B):
Live Load:
LL-Rxn-B=
201
LB
Dead Load:
DL-Rxn-B=
75
LB
Total Load:
TL-Rxn-B=
276
LB
Bearing Length Required (Beam only, support capacity not checked):
BL -B=
0.46
IN
Joist Data:
Center Span Length:
L2=
7.54
FT
Floor sheathing applied to top of joists -top of joists fully braced.
Live Load Duration Factor.
Cd=
1.00
Live Load Deflect. Criteria:
U
480
Total Load Deflect. Criteria:
U
360
Center Span Loading:
Uniform Floor Loading:
Live Load:
LL -2=
40.0
PSF
Dead Load:
DL -2=
15.0
PSF
Total Load:
TL -2=
55.0
PSF
Total Load Adiusted for Joist Spacing:
wT-2=
73
PLF
Properties For: #2- Hem -Fir
Fb=
850
PSI
Bending Stress:
Shear Stress:
Fv=
150
PSI
Modulus of Elasticity:
E=
1300000
PSI
Adiusted Modulus of Elasticity:
E -Min=
470000
PSI
Stress Perpendicular to Grain:
Fc -perp=
405
PSI
Adjusted Properties
Fb' (Tension):
Fb'=
1271
PSI
Adjustment Factors: Cd=1.00 CF=1.30 Cr -1.15
F�:
Fv'=
150
PSI
Adiustment Factors: Cd=1.00
Design Requirements:
M=
521
FT -LB
Controlling Moment:
3.77 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads on span(s) 2
Controlling Shear:
V=
243
LB
At a distance d from right support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on span(s) 2
Comparisons With Required Sections:
Sreq=
4.92
IN3
Section Modulus (Moment):
S=
7.56
IN3
Area (Shear):
Areq=
2.43
IN2
A=
8.25
IN2
Moment of Inertia (Deflection):
Ireq=
16.32
IN4
1=
20.80
IN4
Floor Joist[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: 2ND FLOOR JOISTS
Summary:
1.5 IN x 5.5 IN x 7.54 FT @ 16 O.C. / #2 - Hem -Fir - Dry Use
Section Adequate By: 27.4% Controlling Factor: Moment of Inertia / Depth Required 5.07 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
300
150
Shear
(Ibs) 0
-150
-300
600
300
Moment
(ft -Ib) 0
-300
-600
-0.2
-0.1
Deflection
(in) 0
0.1
0.2
Controlling Load Cases:
Shear: Critical shear created by corn
Moment: Critical moment created by
Deflection: Critical deflection createc
all dead loads and live loads on span(s) 2
ning all dead loads and live loads on span(s) 2
mbining all dead loads and live loads on span('.
LOADING DIAGRAM
2
Center Span = 7.54 ft
Uniformly Loaded Floor Beam[ 2006 International Buildinq Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Desiqn on: 12-03-2008:
4:00:19 PM
Proiect: WALKER - Location: RIM JOIST AS HEADER (c@ LANDING)
Summary:
1.5 IN x 11.25 IN x 4.0 FT / #2 - Hem-Fir - Dry Use
Section Adequate By: 73.7% Controlling Factor: Section Modulus / Depth
Required 8.54 In
Deflections:
Dead Load:
DLD=
0.00
IN
Live Load:
LLD=
0.01
IN = U4131
Total Load:
TLD=
0.02
IN = L/2990
Reactions (Each End):
Live Load:
LL-Rxn=
934
LB
Dead Load:
DL-Rxn=
356
LB
Total Load:
TL-Rxn=
1290
LB
Bearing Length Required (Beam only, support capacity not checked):
BL=
2.12
IN
Beam Data:
Span:
L=
4.0
FT
Unbraced Lenqth-Top of Beam:
Lu=
0.0
FT
Live Load Deflect. Criteria:
U
360
Total Load Deflect. Criteria:
U
240
Floor Loadinq:
Floor Live Load-Side One:
LL1=
40.0
PSF
Floor Dead Load-Side One:
DL1=
15.0
PSF
Tributary Width-Side One:
TW1=
10.0
FT
Floor Live Load-Side Two:
LL2=
40.0
PSF
Floor Dead Load-Side Two:
DL2=
15.0
PSF
Tributary Width-Side Two:
TW2=
1.67
FT
Live Load Duration Factor:
Cd=
1.00
Wall Load:
WALL=
0
PLF
Beam Loadinq:
Beam Total Live Load:
wL=
467
PLF
Beam Self Weight:
BSW=
3
PLF
Beam Total Dead Load:
wD=178
PLF
Total Maximum Load:
WT=
645
PLF
Properties For. #2- Hem-Fir
Bendinq Stress:
Fb=
850
PSI
Shear Stress:
Fv=
150
PSI
Modulus of Elasticity:
E=
1300000
PSI
Adiusted Modulus of Elasticity:
E-Min=
470000
PSI
Stress Perpendicular to Grain:
Fc_perp=
405
PSI
Adjusted Properties
Fb' (Tension):
Fb'=
850
PSI
Adjustment Factors: Cd=1.00 CF=1.00
Fv':
Fv'=
150
PSI
Adiustment Factors: Cd=1.00
Design Requirements:
Controlling Moment:
M=
1290
FT-LB
2.0 ft from left support
Critical moment created by combining all dead and live loads.
Controlling Shear:
V=
697
LB
At a distance d from support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq=
18.21
IN3
S=
31.64
IN3
Area (Shear):
Areq=
6.97
IN2
A=
16.88
IN2
Moment of Inertia (Deflection):
Ireq=
15.51
IN4
1=
177.98
IN4
Uniformly Loaded Floor Beam[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma , P.T. Design on: 12-03-2008
Project: WALKER - Location: RIM JOIST AS HEADER (@ LANDING)
Summary:
1.5 IN x 11.25 IN x 4.0 FT / #2 - Hem -Fir - Dry Use
Section Adequate By: 73.7% Controlling Factor: Section Modulus / Depth Required 8.54 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
2000
1000
Shear
(lbs) 0
-1000
-2000
2000
1000
Moment
(ft -Ib) 0
-1000
-2000
-0.02
-0.01
Deflection
(in) 0
0.01
0.02
Controlling Load Cases:
Shear: Critical shear created by combining all dead and live loads.
Moment: Critical moment created by combining all dead and live loads.
Deflection: Critical deflection created by live loads only.
LOADING DIAGRAM
Span = 4 ft
Uniformly Loaded Floor Beam[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008:
4:00:16 PM
Project: WALKER - Location: LANDING EDGE BEAM
Summary:
1.5 IN x 5.5 IN x 4.0 FT / #2 - Hem -Fir - Dry Use
Section Adequate By: 268.5% Controlling Factor: Section Modulus / Depth Required 2.87 In
Deflections:
Dead Load:
DLD=
0.01
IN
Live Load:
LLD=
0.01
IN = U3333
Total Load:
TLD=
0.02
IN = L/2385
Reactions (Each End):
Live Load:
LL-Rxn=
135
LB
Dead Load:
DL-Rxn=
54
LB
Total Load:
TL-Rxn=
189
LB
Bearing Length Required (Beam only, support capacity not checked):
BL=
0.31
IN
Beam Data:
Span:
L=
4.0
FT
Unbraced Lenqth-Top of Beam:
Lu=
0.0
FT
Live Load Deflect. Criteria:
U
360
Total Load Deflect. Criteria:
U
240
Floor Loading:
Floor Live Load -Side One:
LL1=
40.0
PSF
Floor Dead Load -Side One:
DL1=
15.0
PSF
Tributary Width -Side One:
TW1=
1.69
FT
Floor Live Load -Side Two:
LL2=
40.0
PSF
Floor Dead Load -Side Two:
DL2=
15.0
PSF
Tributary Width -Side Two:
TW2=
0.0
FT
Live Load Duration Factor:
Cd=
1.00
Wall Load:
WALL=
0
PLF
Beam Loading:
Beam Total Live Load:
wL=
68
PLF
Beam Self Weight:
BSW=
2
PLF
Beam Total Dead Load:
WD=
27
PLF
Total Maximum Load:
WT=
94
PLF
Properties For: #2- Hem -Fir
Bending Stress:
Fb=
850
PSI
Shear Stress:
Fv=
150
PSI
Modulus of Elasticity:
E=
1300000
PSI
Adjusted Modulus of Elasticity:
E -Min=
470000
PSI
Stress Perpendicular to Grain:
Fc—perp=
405
PSI
Adjusted Properties
Fb' (Tension):
Fb'=
1105
PSI
Adjustment Factors: Cd=1.00 CF=1.30
Fv':
Fv'=
150
PSI
Adjustment Factors: Cd=1.00
Design Requirements:
Controlling Moment:
M=
189
FT -LB
2.0 ft from left support
Critical moment created by combining all dead and live loads.
Controlling Shear:
V=
147
LB
At a distance d from support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq=
2.05
IN3
S=
7.56
IN3
Area (Shear):
Areq=
1.47
IN2
A=
8.25
IN2
Moment of Inertia (Deflection):
Ireq=
2.25
IN4
1=
20.80
IN4
Uniformly Loaded Floor Beam[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: LANDING EDGE BEAM
Summary:
1.5 IN x 5.5 IN x 4.0 FT / #2 - Hem -Fir - Dry Use
Section Adequate By: 268.5% Controlling Factor: Section Modulus / Depth Required 2.87 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
200
100
Shear
(Ibs) 0
-100
-200
200
100
Moment
(ft -Ib) 0
-100
-200
-0.02
-0.01
Deflection
(in) 0
0.01
0.02
Controlling Load Cases:
Shear: Critical shear created by combining all dead and live loads.
Moment: Critical moment created by combining all dead and live loads.
Deflection: Critical deflection created by live loads only.
LOADING DIAGRAM
Span = 4 ft
Multi -Loaded Beam[ 2006 International Building Code (05 NDS)1 Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008: 4:00:32 PM
Proiect: WALKER - Location: NEW WINDOW HDR. @ RIDGE
Summary:
3.5 IN x 7.251N x 5.33 FT / #1 - Douglas -Fir -Larch - Dry Use
Section Adequate By: 33.4% Controlling Factor: Section Modulus / Depth Required 6.28 In
Center Span Deflections:
Dead Load:
Live Load:
Total Load:
Center Span Left End Reactions (Support A):
Live Load:
Dead Load:
Total Load:
Bearing Length Required (Beam only, support capacity not checked)
Center Span Right End Reactions (Support B):
Live Load:
Dead Load:
Total Load:
Bearing Length Required (Beam only, support capacity not checked)
Beam Data:
Center Span Length:
Center Span Unbraced Length -Top of Beam:
Center Span Unbraced Length -Bottom of Beam:
Live Load Duration Factor:
Live Load Deflect. Criteria:
Total Load Deflect. Criteria:
Center Span Loading:
Uniform Load:
Live Load:
Dead Load:
Beam Self Weight:
Total Load:
Point Load 1
Live Load:
Dead Load:
Location (From left end of span):
Properties For: #1- Douqlas-Fir-Larch
Bending Stress:
Shear Stress:
Modulus of Elasticity:
Adiusted Modulus of Elasticity:
Stress Perpendicular to Grain:
Adjusted Properties
Fb' (Tension):
Adjustment Factors: Cd=1.00 CF=1.30
Fv':
DLD-Center=
0.02
IN
LLD -Center-
0.03
IN = U2016
TLD -Center-
0.05
IN = U1182
LL-Rxn-A=
549
LB
DL-Rxn-A=
393
LB
TL-Rxn-A=
942
LB
BL -A=
0.43
IN
LL-Rxn-B=
551
LB
DL-Rxn-B=
394
LB
TL-Rxn-B=
945
LB
BL -B=
0.43
IN
L2=
5.33
FT
Lug -Top=
0.0
FT
Lug -Bottom=
5.33
FT
Cd=
1.00
U
360
U
240
wL-2=
0
PLF
wD-2=
0
PLF
BSW=
6
PLF
wT-2=
6
PLF
PL1-2=
1100
LB
PD1 -2=
758
LB
X1-2=
2.67
FT
Fb=
1000
PSI
Fv=
180
PSI
E=
1700000
PSI
E -Min=
620000
PSI
Fc_perp=
625
PSI
Fb'=
1300
PSI
Fv'=
180
PSI
Adiustment Factors: Cd=1.00
Design Requirements:
Controlling Moment:
M=
2491
FT -LB
2.665 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads on span(s) 2
Controlling Shear:
V=
942
LB
At a distance d from right support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on span(s) 2
Comparisons With Required Sections:
Sreq=
22.99
IN3
Section Modulus (Moment):
S=
30.66
IN3
Area (Shear):
Areq=
A=
7.85
25.38
IN2
IN2
Moment of Inertia (Deflection):
Ireq=
1=
22.57
111.15
IN4
IN4
Multi -Loaded Beam[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: NEW WINDOW HDR. @ RIDGE
Summary:
3.5 IN x 7.25 IN x 5.33 FT /#1 - Douglas -Fir -Larch - Dry Use
Section Adequate By: 33.4% Controlling Factor: Section Modulus / Depth Required 6.28 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
1000
500
Shear
(Ibs) 0
-500
-1000
3000
1500
Moment
(ft -Ib) 0
-1500
-3000
-0.06
-0.03
Deflection
(in) 0
0.03
0.06
Controlling Load Cases:
Shear. Critical shear created by combining all dead loads and live loads on span(s) 2
Moment: Critical moment created by combining all dead loads and live loads on span(s) 2
Deflection: Critical deflection created by combining all dead loads and live loads on span(s) 2
LOADING DIAGRAM
P1
i
A
Center Span = 5.33 ft
Multi -Loaded Beam( 2006 International Buildinq Code (05 NDS)1 Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008: 4:00:35 PM
Proiect: WALKER - Location: RIDGES HEADER
Summary:
5.51N x 5.5 IN x 3.88 FT /#2 -Douglas-Fir-Larch (North) -Dry Use
Section Adequate By: 1.8% Controlling Factor: Section Modulus / Depth Required 5.45 In
Center Span Deflections:
Dead Load:
Live Load:
Total Load:
Center Span Left End Reactions (Support A):
Live Load:
Dead Load:
Total Load:
Bearing Lenqth Required (Beam only, support capacity not checked):
Center Span Riqht End Reactions (Support B):
Live Load:
Dead Load:
Total Load:
Bearing Length Required (Beam only, support capacity not checked):
Beam Data:
Center Span Length:
Center Span Unbraced Lenqth-Top of Beam:
Center Span Unbraced Length -Bottom of Beam:
Live Load Duration Factor:
Live Load Deflect. Criteria:
Total Load Deflect. Criteria:
Center Span Loading:
Uniform Load:
Live Load:
Dead Load:
Beam Self Weight:
Total Load:
Point Load 1
Live Load:
Dead Load:
Location (From left end of span):
Properties For: #2- Douqlas-Fir-Larch (North)
Bendinq Stress:
Shear Stress:
Modulus of Elasticity:
Adiusted Modulus of Elasticity:
Stress Perpendicular to Grain:
Adjusted Properties
Fb' (Tension):
Adjustment Factors: Cd=1.00 CF=1.00
FV:
DLD-Center=
0.01
IN
LLD -Center=
0.02
IN = U2329
TLD -Center—
0.03
IN = U1367
LL-Rxn-A=
1000
LB
DL-Rxn-A=
699
LB
TL-Rxn-A=
1699
LB
BL -A=
0.49
IN
LL-Rxn-B=
338
LB
DL-Rxn-B=
245
LB
TL-Rxn-B=
583
LB
BL -B=
0.17
IN
L2=
3.88
FT
Lug -Top=
0.0
FT
Lu2-Bottom=
3.88
FT
Cd=
1.00
U
360
U
240
wL-2=
0
PLF
wD-2=
0
PLF
BSW=
6
PLF
wT-2=
6
PLF
PL1-2=
1338
LB
PD1 -2=
919
LB
X1-2=
0.98
FT
Fb=
725
PSI
Fv=
170
PSI
E=
1300000
PSI
E -Min=
470000
PSI
Fc_perp=
625
PSI
Adiustment Factors: Cd=1.00
Design Requirements:
Controllinq Moment:
1.009 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads on span(s)
Controllinq Shear:
At a distance d from left support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on span(s) 2
Comparisons With Required Sections:
Section Modulus (Moment):
Area (Shear):
Moment of Inertia (Deflection):
Fb'=
725
PSI
FV=
170
PSI
M=
1646
FT -LB
2
V=
1697
LB
Sreq=
27.25
IN3
S=
27.73
IN3
Areq=
14.97
IN2
A=
30.25
IN2
Ireq=
13.38
IN4
1=
76.26
IN4
Multi -Loaded Beam[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: RIDGES HEADER
Summary:
5.5 IN x 5.5 IN x 3.88 FT / #2 - Douglas -Fir -Larch (North) - Dry Use
Section Adeauate Bv: 1.8% Controllina Factor: Section Modulus / Depth Required 5.45 In
2000
1000
Shear
(Ibs) 0
-1000
-2000
2000
1000
Moment
(ft -Ib) 0
-1000
-2000
-0.04
-0.02
Deflection
(in) 0
0.02
0.04
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
Controlling Load Cases:
Shear: Critical shear created by combining all dead loads and live loads on span(s) 2
Moment: Critical moment created by combining all dead loads and live loads on span(s) 2
Deflection: Critical deflection created by combining all dead loads and live loads ons an
P1
LOADING DIAGRAM
Center Span = 3.88 ft
2
J
Roof Beam[ 2006 International Building Code (05 NDS)1 Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008:
4:00:24 PM
Proiect: WALKER - Location: EXISTING RIDGE -NEW GLULAM
Summary:
6.75 IN x 12.0 IN x 23.08 FT / 24F -V4 - Visually Graded Western Species - Dry Use
Section Adequate By: 3.2% Controlling Factor: Moment of Inertia / Depth Required 11.87 In
Deflections:
Dead Load:
DLD=
0.62
IN
Live Load:
LLD=
0.87
IN = U317
Total Load:
TLD=
1.49
IN = U186
Reactions (Each End):
Live Load:
LL-Rxn=
2764
LB
Dead Load:
DL-Rxn=
1951
LB
Total Load:
TL-Rxn=
4714
LB
Bearinq Lenqth Required (Beam only, support capacity not checked):
BL=
1.07
IN
Camber Reqd.:
C=
0.93
IN
Beam Data:
Span:
L=
23.08
FT
Maximum Unbraced Span:
Lu=
0.0
FT
Pitch Of Roof:
RP=
4.
:12
Live Load Deflect. Criteria:
U
240
Total Load Deflect. Criteria:
U
180
Camber Adjustment Factor:
CAF=
1.5
X DLD
Roof Loadinq:
Roof Live Load -Side One:
LL1=
25.0
PSF
Roof Dead Load -Side One:
DLI=
15.0
PSF
Tributary Width -Side One:
TW1=
4.79
FT
Roof Live Load -Side Two:
LL2=
25.0
PSF
Roof Dead Load -Side Two:
DL2=
15.0
PSF
Tributary Width -Side Two:
TW2=
4.79
FT
Roof Duration Factor:
Cd=
1.15
Beam Self Weiqht:
BSW=
18
PLF
Slope/Pitch Adiusted Lenqths and Loads:
Adiusted Beam Lenqth:
Ladi=
23.08
FT
Beam Unfform Live Load:
wL=
240
PLF
Beam Uniform Dead Load:
wD_adi=
169
PLF
Total Uniform Load:
WT=
409
PLF
Properties For: 24F -V4- Visually Graded Western Species
Bendinq Stress:
Fb=
2400
PSI
Shear Stress:
Fv=
265
PSI
Modulus of Elasticity:
E=
1800000
PSI
Adiusted Modulus of Elasticity:
E -Min=
930000
PSI
Stress Perpendicular to Grain:
Fc perp=
650
PSI
Bendinq Stress of Comp. Face in Tension:
Fb_cpr=
1850
PSI
Adjusted Properties
Fb' (Tension):
Fb'=
2660
PSI
Adjustment Factors: Cd=1.15 Cv=0.96
Fv':
Fv'=
305
PSI
Adiustment Factors: Cd=1.15
Design Requirements:
Controllinq Moment:
M=
27202
FT -LB
11.54 ft from left support
Critical moment created by combining all dead and live loads.
Controllinq Shear:
V=
4337
LB
At a distance d from support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq=
122.73
IN3
S=
162.00
IN3
Area (Shear):
Areq=
21.35
IN2
A=
81.00
IN2
Moment of Inertia (Deflection):
Iraq=
941.60
IN4
1=
972.00
IN4
Roof Beam[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: EXISTING RIDGE -NEW GLULAM
Summary:
6.75 IN x 12.0 IN x 23.08 FT / 24F -V4 - Visually Graded Western Species - Dry Use
Section Adequate By: 3.2% Controlling Factor: Moment of Inertia /Depth Required 11.87 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
5000
2500
Shear
(Ibs) 0
-2500
-5000
15000
Moment
(ft -Ib) 0
-15000
-30000
-2
-1
Deflector
(in) 0
Controlling Load Cases:
Shear: Critical shear created by combining all dead and live loads.
Moment: Critical moment created by combining all dead and live loads.
Deflection: Critical deflection created by combining all dead and live loads.
LOADING DIAGRAM
A !�
Span = 23.08 ft
Multi -Loaded Beamf 2006 International Building Code (05 NDS)1 Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008: 4:00:29 PM
Proiect: WALKER - Location: NEW DORMER RIDGE
Summary:
( 2 ) 1.5 IN x 5.5 IN x 9.5 FT /#2 -Hem -Fir -Dry Use
Section Adequate By: 15.5% Controlling Factor: Section Modulus / Depth Required 5.12 In
Center Span Deflections:
Dead Load:
DLD-Center=
0.14
IN
Live Load:
LLD -Center=
0.21
IN = U545
Total Load:
TLD -Center-
0.34
IN = U330
Center Span Left End Reactions (Support A):
Live Load:
LL-Rxn-A=
444
LB
Dead Load:
DL-Rxn-A=
281
LB
Total Load:
TL-Rxn-A=
725
LB
Bearing Length Required (Beam only, support capacity not checked):
BL -A=
0.60
IN
Center Span Right End Reactions (Support B):
Live Load:
LL-Rxn-B=
164
LB
Dead Load:
DL-Rxn-B=
113
LB
Total Load:
TL-Rxn-B=
276
LB
Bearing Length Required (Beam only, support capacity not checked):
BL -B=
0.23
IN
Beam Data:
Center Span Length:
L2=
9.5
FT
Center Span Unbraced Length -Top of Beam:
Lug -Top=
0.0
FT
Center Span Unbraced Length -Bottom of Beam:
Lu2-Bottom=
9.5
FT
Live Load Duration Factor:
Cd=
1.00
Live Load Deflect. Criteria:
U
360
Total Load Deflect. Criteria:
U
240
Center Span Loading:
Uniform Load:
Live Load:
wL-2=
0
PLF
Dead Load:
wD-2=
0
PLF
Beam Self Weight:
BSW=
3
PLF
Total Load:
wT-2=
3
PLF
Trapezoidal Load 1
Left Live Load:
TRL-Left-1-2=
79
PLF
Left Dead Load:
TRD-Left-1-2=
48
PLF
Right Live Load:
TRL-Riqht-1-2=
0
PLF
Right Dead Load:
TRD-Right-1-2=
0
PLF
Load Start:
A-1-2=
0.0
FT
Load End:
B-1-2=
7.67
FT
Load Length:
C-1-2=
7.67
FT
Trapezoidal Load 2
Left Live Load:
TRL-Left-2-2=
79
PLF
Left Dead Load:
TRD-Left-2-2=
48
PLF
Right Live Load:
TRL-Right-2-2=
0
PLF
Right Dead Load:
TRD-Right-2-2=
0
PLF
Load Start:
A-2-2=
0.0
FT
Load End:
B-2-2=
7.67
FT
Load Length:
C-2-2=
7.67
FT
Properties For: #2- Hem -Fir
Bending Stress:
Fb=
850
PSI
Shear Stress:
Fv=
150
PSI
Modulus of Elasticity:
E=
1300000
PSI
Adiusted Modulus of Elasticity:
E -Min=
470000
PSI
Stress Perpendicular to Grain:
Fc -Perp=
405
PSI
Adjusted Properties
Fb' (Tension):
Fb'=
1105
PSI
Adjustment Factors: Cd=1.00 CF=1.30
Fv':
Fv'=
150
PSI
Adiustment Factors: Cd=1.00
Design Requirements:
Controlling Moment:
M=
1206
FT -LB
3.705 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads on span(s) 2
Controlling Shear:
V=
630
LB
At a distance d from left support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on span(s) 2
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq=
13.10
IN3
S=
15.13
IN3
Area (Shear):
Areq=
6.30
IN2
A=
16.50
IN2
Moment of Inertia (Deflection):
Ireq=
30.21
IN4
1=
41.59
IN4
Multi -Loaded Beam[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: NEW DORMER RIDGE
Summary:
( 2 ) 1.5 1N x 5.5 1N x 9.5 FT / #2 - Hem -Fir - Dry Use
Section Adequate By: 15.5% Controlling Factor: Section Modulus / Depth Required 5.12 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
800
400
Shear
(lbs) 0
-400
-800
2000
1000
Moment
(ft -Ib) 0
-1000
-2000
-0.4
-0.2
Deflection
(in) 0
0.2
0.4
Controlling Load Cases:
Shear: Critical shear created by com
Moment: Critical moment created by
Deflection: Critical deflection created
all dead loads and live loads on span(s) 2
ning all dead loads and live loads on span(s) 2
nbining all dead loads and live loads on span(;
LOADING DIAGRAM
Center Span = 9.5 ft
Roof Beamf 2006 International Buildinq Code (05 NDS)1 Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008:
4:00:27 PM
Project: WALKER - Location: NEW ADDITION RIDGE
Summary:
( 2 ) 1.5 IN x 9.25 IN x 8.0 FT / Select Structural - Hem-Fir - Dry Use
Section Adequate By: 69.9% Controllinq Factor: Section Modulus / Depth
Required 7.1 In
* Laminations are to be fully connected to provide uniform transfer of loads
to all members
Deflections:
Dead Load:
DLD=
0.06
IN
Live Load:
LLD=
0.08
IN = L/1199
Total Load:
TLD=
0.14
IN = U710
Reactions (Each End):
Live Load:
LL-Rxn=
1100
LB
Dead Load:
DL-Rxn=
759
LB
Total Load:
TL-Rxn=
1859
LB
Bearing Length Required (Beam only, support capacity not checked):
BL=
1.53
IN
Beam Data:
Span:
L=
8.0
FT
Maximum Unbraced Span:
Lu=
0.0
FT
Pitch Of Roof:
RP=
6.
:12
Live Load Deflect. Criteria:
U
240
Total Load Deflect. Criteria:
U
180
Roof Loadinq:
Roof Live Load-Side One:
LL1=
25.0
PSF
Roof Dead Load-Side One:
DL1=
15.0
PSF
Tributary Width-Side One:
TW1=
5.5
FT
Roof Live Load-Side Two:
LL2=
25.0
PSF
Roof Dead Load-Side Two:
DL2=
15.0
PSF
Tributary Width-Side Two:
TW2=
5.5
FT
Roof Duration Factor:
Cd=
1.15
Beam Self Weiqht:
BSW=
5
PLF
Slope/Pitch Adjusted Lenqths and Loads:
Adjusted Beam Lenqth:
Ladi=
8.0
FT
Beam Uniform Live Load:
wL=
275
PLF
Beam Uniform Dead Load:
wD adi=
190
PLF
Total Uniform Load:
WT=
465
PLF
Properties For: Select Structural- Hem-Fir
Bendinq Stress:
Fb=
1400
PSI
Shear Stress:
Fv=
150
PSI
Modulus of Elasticity:
E=
1600000
PSI
Adjusted Modulus of Elasticity:
E-Min=
580000
PSI
Stress Perpendicular to Grain:
Fcaerp=
405
PSI
Adjusted Properties
Fb' (Tension):
Fb'=
1771
PSI
Adjustment Factors: Cd=1.15 CF=I. 10
Fv':
Fv'=
173
PSI
Adjustment Factors: Cd=1.15
Design Requirements:
Controllinq Moment:
M=
3717
FT-LB
4.0 ft from left support
Critical moment created by combining all dead and live loads.
Controllinq Shear.
V=
1524
LB
At a distance d from support.
Critical shear created by combining all dead and live loads.
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq=
25.19
IN3
S=
42.78
IN3
Area (Shear):
Areq=
13.25
IN2
A=
27.75
IN2
Moment of Inertia (Deflection):
Ireq=
50.17
IN4
1=
197.86
IN4
Roof Beam[ 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: NEW ADDITION RIDGE
Summary:
( 2 ) 1.5 IN x 9.25 IN x 8.0 FT / Select Structural - Hem -Fir - Dry Use
Section Adequate By: 69.9% Controlling Factor: Section Modulus / Depth Required 7.1 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
2000
1000
Shear
(Ibs) 0
-1000
-2000
4000
2000
Moment
(ft -Ib) 0
-2000
-4000
-0.2
-0.1
Deflection
(in) 0
0.1
0.2
Controlling Load Cases:
Shear: Critical shear created by combining all dead and live loads.
Moment: Critical moment created by combining all dead and live loads.
Deflection: Critical deflection created by combining all dead and live loads.
LOADING DIAGRAM
Span = 8 ft
Roof Rafter( 2006 International Building Code (05 NDS) ) Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008: 4:00:38 PM
Proiect: WALKER - Location: RAFTER -TYPICAL
Summary:.
IN x 9.25 IN x 10.54 FT p 24 O.C. / #2 -Hem-Fir -Dry Use
Section Adequate By: 90.0% Controlling Factor: Section Modulus / Depth Required 6.71 In
Rafter Span Deflections:
Dead Load:
DLD-Interior-
0.09
IN
Live Load:
LLD -Interior=
0.13
IN = U1048
Total Load:
TLD -Interior-
0.23
IN = U627
Rafter End Loads and Reactions:
LOADS:
RXNS:
Upper Live Load:
132 PLF
264 LB
Upper Dead Load:
88 PLF
177 LB
Upper Total Load:
220 PLF
440 LB
Lower Live Load:
132 PLF
264 LB
Lower Dead Load:
88 PLF
177 LB
Lower Total Load:
220 PLF
440 LB
Upper Equiv. Tributary Width:
UTWeq=
5.89
FT
Lower Equiv. Tributary Width:
LTWeq=
5.89
FT
Rafter Data:
Interior Span:
L=
10.54
FT
Eave Span:
L-Eave=
0.0
FT
Rafter Spacing:
Spacing=
24.0
IN O.C.
Rafter Pitch:
RP=
6.0
:12
Roof sheathing applied to top of joists -Top of rafters fully braced.
Live Load Deflect. Criteria:
U
240
Total Load Deflect. Criteria:
U
180
Rafter Loads:
Roof Live Load:
LL=
25.0
PSF
Roof Dead Load:
DL=
15.0
PSF
Roof Duration Factor:
Cd=
1.15
Slope Adiusted Spans And Loads:
Interior Span:
L-adi=
11.78
FT
Rafter Live Load:
wL-adi=
40
PLF
Rafter Dead Load:
wD-adi=
27
PLF
Rafter Total Load:
wT-adj=
67
PLF
Properties For: #2- Hem -Fir
Bending Stress:
Fb=
850
PSI
Shear Stress:
Fv=
150
PSI
Modulus of Elasticity:
E=
1300000
PSI
Adiusted Modulus of Elasticity:
E -Min=
470000
PSI
Stress Perpendicular to Grain:
Fc -perp=
405
PSI
Adjusted Properties
Fb' (Tension):
Fb'=
1237
PSI
Adjustment Factors: Cd=1.15 CF=1.10 Cr--1.15
Fw:
Fv'=
173
PSI
Adiustment Factors: Cd=1.15
Design Requirements:
Controlling Moment:
M=
1160
FT -LB
5.892 Ft from left support of span 2 (Center Span)
Critical moment created by combining all dead loads and live loads on span(s) 2
Controlling Shear:
V=
347
LB
At a distance d from right support of span 2 (Center Span)
Critical shear created by combining all dead loads and live loads on span(s) 2
Comparisons With Required Sections:
Section Modulus (Moment):
Sreq=
11.26
IN3
S=
21.39
IN3
Area (Shear):
Areq=
3.01
IN2
A=
13.88
IN2
Moment of Inertia (Deflection):
Ireq=
28.39
IN4
1=
98.93
IN4
Roof Rafterf 2006 International Building Code (05 NDS) ] Ver: 7.01.14
By: Eric Kuzma, P.T. Design on: 12-03-2008
Project: WALKER - Location: RAFTER -TYPICAL
Summary:
1.5 IN x 9.25 IN x 10.54 FT @ 24 O.C. / #2 - Hem -Fir - Dry Use
Section Adequate By: 90.0% Controlling Factor: Section Modulus / Depth Required 6.71 In
SHEAR, MOMENT, AND DEFLECTION DIAGRAMS
400
200
Shear
(Ibs) 0
-200
-400
2000
1000
Moment
(ft -Ib) 0
-1000
-2000
-0.3
-0.15
Deflection
(in) 0
0.15
0.3
Controlling Load Cases:
Shear: Critical shear created by combining all dead loads and live loads on span(s) 2
Moment: Critical moment created by combining all dead loads and live loads on span(s) 2
Deflection Critical deflection created by combining all dead loads and live loads on span(s) 2
LOADING DIAGRAM
Rafter Span = 10.54 ft (11.78 ft)
Rafter Pitch: 6 : 12
AN ADDITION FOR: SCOTT NALKER
3410 CLIFF STREET, PORT TOHN5END, HA g8368
PROJECT DATA:
NEN ADDITION
ZONING: R-1
TAX PARCEL#: 4541-100-301 (302) (303)
LEGAL DE50RIPTION:
SECTION: 4, QTR. SECTION: NE 1/4,
TOHN5HIP: 30 N, RANGE: IN.
HILLS ADDITION
BLK 3, LOTS 1-8
EXI5TIN6 HOUSE
15T FLOOR: 480 s.f.
2ND FLOOR: 480 s.f. ✓
TOTAL PATIO 4 DECK AREA: 144 s.f.
DRIVEWAY 4 WALKWAY: 520 s.f.
VIOINITY PLAN
31ST STREET
CAPE GEORGE
15T FLOOR: 116 s.f.
2ND FLOOR: 48 s.f.
LOT GOVERA&E 4 IMPERVIOUS AREA:
(FOR PARCEL #q5q-100-302)
LOT 51ZE: 20,000 s.f.
TOTAL LOT COVERAGE (EXISTING 4
PROP05ED BUILDING FOOTPRINT):
65b s.f. or 3.3% (( 35% ALLOWABLE)
TOTAL IMPERVIOUS SURFACE: 1320 s.f.
or 6.b% (( 40% ALLOHABLE)
THI5 PROJECT SHALL COMPLY WITH
THE FOLLOHIN6 CODE -5: 2006 I.R.G.,
2006 H5EC, 2006 VIAO
35TH STREET
SITE
3410
DY
STREET
ASTINGS AVENUE
(360) 3141-41288
55th STREET
x—
o �I;
mrn
> D rn
rn O
rI�
I
51 TE PLAN
50ALE: I" = 40'-0°
INDEX TO DRANIN65
N 9qr' :;I' d^," F
REV. # DATE: DESCRIPTION:
0 ERIC KUZMA 2009 c I r'�
U PICIA �1I' AA" 7-
i 100.00 100.00' i
(10'-0"SETBACK)-------------5
I I
I I
1FARGEL# q5�-100-501 (LOTS I42) PARGEL# 1515�-100-303 (LOTS 14¢)
I I
LOT I LOT 8
of to
J.
t
T1 I�
1 LOT 2 1 LOT 1
SETBACK)—v— 1
I
I o RG ;.� I +. I
1 - 1 1. Dv'N I
DRIVEWAY
I
I
I
EX15 16
ZZ �,RA NFIELD
_ _
I — —(I '-0" SES
-_-_; 24'-0" � 1
I
I
LOT 5 L LOT 6
TANK I
4RGEL� 15 7001 R02 (LOTS 5-6)
I
--—--—————— — — ---� --
AG OT 411, LOT 5
N_ 8Gd 51'48` F
I PROJECT DATA, SITE/ VICINITY PLANS 1 DETAILED SECTION - B
2 PROP05ED 15T FLOOR PLAN 8 PROPOSED HE5T ELEVATION
JAN 2 9
CITY Of PORT 1
a DSD
200.00'
NOTE TO GONTRAGTOR5 $ BUILDING OFF I O I AL5:
I. THESE PLANS ARE INTENDED TO CONTAIN ALL THE INFORMATION
REQUIRED TO DEMONSTRATE COMPLIANCE WITH APPLICABLE BUILDING
4 ZONING CODES. IN THE CASE OF ANY INFORMATION WHICH APPEARS
TO BE LAGKIN6, PLEASE CONTACT THE DE516NER IMMEDIATELY.
3 PROPOSED 2ND FLOOR PLAN 4 PROP05ED SOUTH ELEVATION
2. THESE PLANS CONTAIN THE MAJORITY OF INFORMATION REQUIRED
>
TO BUILD THE 5TRUGTURE A5 SHOWN. HONEVER, IT 15 NOT P0551BLE
ILL
4 FOUNDATION/ 15T FLR. FRAMING 10 PROP05W EAST ELEVATION
w
Z
w
4 2ND FLOOR FRAMING II PROP05ED NORTH ELEVATION
BALANCE BETWEEN PROV15ION OF INFORMATION 4 COST OF THE PLANS.
Of
cy
THE PLANS HILL INEVITABLY CONTAIN MINOR 015CREPANCIE5 4 AREAS
U)
5 ROOF FRAMING PLAN 12 PERSPECTIVE VIEH5
cn
Lu
m
N
a
6 DETAILED SECTION - A
THE BEST RE50LUTION OF THESE 155UE5 15 M05T OFTEN ACHIEVED THROUGH
�
A JOINT DECISION MAKING PROCESS INVOLVING THE OWNER(5)/DE516NER
4 GONTRAGTOR(S).BLD 0 9® 0 1 6
PORT TOWNSEND
Cl-
d
0
ASTINGS AVENUE
(360) 3141-41288
55th STREET
x—
o �I;
mrn
> D rn
rn O
rI�
I
51 TE PLAN
50ALE: I" = 40'-0°
INDEX TO DRANIN65
N 9qr' :;I' d^," F
REV. # DATE: DESCRIPTION:
0 ERIC KUZMA 2009 c I r'�
U PICIA �1I' AA" 7-
i 100.00 100.00' i
(10'-0"SETBACK)-------------5
I I
I I
1FARGEL# q5�-100-501 (LOTS I42) PARGEL# 1515�-100-303 (LOTS 14¢)
I I
LOT I LOT 8
of to
J.
t
T1 I�
1 LOT 2 1 LOT 1
SETBACK)—v— 1
I
I o RG ;.� I +. I
1 - 1 1. Dv'N I
DRIVEWAY
I
I
I
EX15 16
ZZ �,RA NFIELD
_ _
I — —(I '-0" SES
-_-_; 24'-0" � 1
I
I
LOT 5 L LOT 6
TANK I
4RGEL� 15 7001 R02 (LOTS 5-6)
I
--—--—————— — — ---� --
AG OT 411, LOT 5
N_ 8Gd 51'48` F
I PROJECT DATA, SITE/ VICINITY PLANS 1 DETAILED SECTION - B
2 PROP05ED 15T FLOOR PLAN 8 PROPOSED HE5T ELEVATION
JAN 2 9
CITY Of PORT 1
a DSD
200.00'
NOTE TO GONTRAGTOR5 $ BUILDING OFF I O I AL5:
I. THESE PLANS ARE INTENDED TO CONTAIN ALL THE INFORMATION
REQUIRED TO DEMONSTRATE COMPLIANCE WITH APPLICABLE BUILDING
4 ZONING CODES. IN THE CASE OF ANY INFORMATION WHICH APPEARS
TO BE LAGKIN6, PLEASE CONTACT THE DE516NER IMMEDIATELY.
DATE: 1/7/09
SCALE: AS SHOWN
3 PROPOSED 2ND FLOOR PLAN 4 PROP05ED SOUTH ELEVATION
2. THESE PLANS CONTAIN THE MAJORITY OF INFORMATION REQUIRED
>
TO BUILD THE 5TRUGTURE A5 SHOWN. HONEVER, IT 15 NOT P0551BLE
ILL
4 FOUNDATION/ 15T FLR. FRAMING 10 PROP05W EAST ELEVATION
TO ANTICIPATE EVERY PIECE OF INFORMATION NEEDED FOR CONSTRUCTION.
Z
THE DE516NERHAS MADE A 6000 FAITH EFFORT TO STRIKE A REASONABLE
4 2ND FLOOR FRAMING II PROP05ED NORTH ELEVATION
BALANCE BETWEEN PROV15ION OF INFORMATION 4 COST OF THE PLANS.
C9
cy
THE PLANS HILL INEVITABLY CONTAIN MINOR 015CREPANCIE5 4 AREAS
U)
5 ROOF FRAMING PLAN 12 PERSPECTIVE VIEH5
LAGKIN6 IN SPECIFIC INFORMATION. DURING THE COURSE OF CONSTRUCTION,
Lu
m
AS THESE AREAS EMERGE, THEY HILL REQUIRE ATTENTION 4 RESOLUTION.
6 DETAILED SECTION - A
THE BEST RE50LUTION OF THESE 155UE5 15 M05T OFTEN ACHIEVED THROUGH
A JOINT DECISION MAKING PROCESS INVOLVING THE OWNER(5)/DE516NER
4 GONTRAGTOR(S).BLD 0 9® 0 1 6
PORT TOWNSEND
DATE: 1/7/09
SCALE: AS SHOWN
Z
Q
Q
Q �
U
Z
L LJ U
>
O
0 (,b
CL LTJ
F—
II'
imi
MF..
SEND
LTJ
co
>
00
o0
ILL
Z
wE
W
wy w
C9
cy
-n Z E
U)
111
030 u
Lu
m
�~ m
.nuj
t� v_
�E
0-
F—
Cl-
d
Z
Q
Q
Q �
U
Z
L LJ U
>
O
0 (,b
CL LTJ
F—
II'
imi
MF..
SEND
>
W
�>
Ci
0
LL
OLLI
cy
Lu
V)
LLLL
v
O
Z
LTJ
j
>OO
Q
M
O
SHEET:
OF:
X
PROP05ED ADDITION
I
`~ NO HANDRAIL/
c=v GUARDRAIL REO'D
IF SURFACE 15
LESS THAN 50"
A50VE GRADE
r ---
i
( 'A A
lkil v
PROP05ED F I R5T
FLOOR PLAN
9-'ALE: 1/4° = 1'-0°
0
i
i
�o
DOWN
3'-32°
,
12_WINDER TREADS _6 14
RISERS, FL R. TO FLR. 8'--2"
56" GUARD RAIL 11 CONT.
HAND RAIL ® 36" ABOVE
STAIR N051NG5, BOTH W/
BALUSTERS W/ 4" MAX. GAP
WINDER TREADS SHALL HAVE
A 10" MIN. TREAD DEPTH
MEASURED AT A POINT 12"
FROM NARROWER SIDE $ A
MIN. TREAD DEPTH OF 6"
2/6x4/6
DOUBLE HUNG I
20 GFM
WALL FORT
_ I
k�l I
DA OFFICE
(2) 2/6x4/6 HARDWOOD
LLED
)OU LE HUNG
- 5/0 x 6/5
S� POCKET
5/0 xx 8
FULL LITE
O
,
2
2/6 x 6/8
UP
GL05ET1
0
\t
NEW METER
LOCATION J I
SHED ROOF ABOVE
4'-0' 4'-0"
e'�6
lf� L 2��68
EXI5TIN6 H005E
20'-0"
OPENING FRAMED
(NC�WINDOW)
I.W.h.
(REMOVE
INTERIOR
WALL5)
INFILLED
PREVIOUS
5TAIR
OPENING
L---------
ELEGTRIG
METER/PANEL
GARAGE DOOR
EXI5TING
SHOP
CONCRETE 5LA5
�a �E h �c to
4/4x4/0
OPENING
FRAMED
EXI5TING (NO WINDOW)
OFFICE
OPENING FRAMED
(NO WINDOW)
-- iggglHo
DATE: 1/7/09
.. •
SHEET:
WINDOWS:
WINDOWS TO BE MIL6ARD VINYL, L
OR EQUAL DOLOR TO BE WHITE.
WINDOW HARDWARE TO BE STANDARD. ALL OF:
WINDOWS AND DOORS TO HAVE ,AN NFRO 12
U -VALUE OF 0.35 OR LOWER.
BLD 090016
W
c
.• 11
co
L6
•
�
3
c�
w 0 E ;
(Z
L
w
V!
•
N N ' E
(J1
W>-
3 �
�_
W
m
" .8 _
Lu.—
0
�� dr
E
as a
Lu
C-) ,_iw
�
LL
-
LLLu LL
•
SHEET:
WINDOWS:
WINDOWS TO BE MIL6ARD VINYL, L
OR EQUAL DOLOR TO BE WHITE.
WINDOW HARDWARE TO BE STANDARD. ALL OF:
WINDOWS AND DOORS TO HAVE ,AN NFRO 12
U -VALUE OF 0.35 OR LOWER.
BLD 090016
.• 11
•
.•
•
If
Lu
in
�
LL
-
LLLu LL
•
s�
•
SHEET:
WINDOWS:
WINDOWS TO BE MIL6ARD VINYL, L
OR EQUAL DOLOR TO BE WHITE.
WINDOW HARDWARE TO BE STANDARD. ALL OF:
WINDOWS AND DOORS TO HAVE ,AN NFRO 12
U -VALUE OF 0.35 OR LOWER.
BLD 090016
PR0P05ED ADDITION
FOUNDATION 4 FIRST
G
F''LAO�ORFRAMING PLAN
56ALL: IW = I' -0o
EXI5TIN6 HOUSE
— — — — — — — — — — — — — — — — —
— — — — — — — — — — — — — — — — — —
I
-------------------------------I
\
Z
O
Q<
0
D
ILL 0
TYP. GONG. FOUNDATION HALL
I
GENERAL NOTES: I I
5" FOUNDATION HALL K/ V
OUTSIDE FACE TO HAVE APPROVED
5" DEEP, 16" HIDE FOOTING
HATERPROOF TREATMENT BELOH GRADE I I
1/2",XIO" ANCHOR BOLT N/ 7 MIN. �� ,. p CONTRACTOR TO DETERMINE UTILITY I I
EMBEDMENT H`sile- 776" PLATE;3X_N%y,,
ROUTES 3 FOUNDATION PENETRATIONS I I
K,45HER TYP. @ 45" O.G. & @ 12"
THEN CONFIRM H/ ONNER/ARGHITEGT I I
I FROM EA. END (MIN. 2 PER SILL)
I I
TYP. GONG. HALL REINFORCING
ALL HOOD IN GONTAGT H/ GONGRETE MUST BE
Lv
PRE55URE TREATED OR NATURALLY DECAY I I
#4 @ h" OG. HORIZONTAL ✓
RESISTANT OR 150LATED FROM GONG. WITH I I
4 @ l5" O.G. VERTICAL
IMPERMEABLE MATERIAL. I I
I TYP. FOOTING REINF0RGIN6
ALL METAL G0NNEGT0R5 IN GONTAGT KITH I I
(2) #4 CONTINUOUS BARS @
PRESSURE TREATED HOOD TO BE GALVANIZED TO I I
3" FROM BOTTOM OF FOOTING
MINIMUM STANDARDS OF 6155 (SIMPS0N 'Z -MAX')
V
(TIE VERT. HALL EARS ALTERNATELY ✓
OR HOT -DIP GALVANIZED (SIMPSON 'HD6). ALL I I
TO EACH HORIZ. FTG. BAR)
NAILS, SGREHS, BOLTS AND OTHER CONNECTORS I I
I
IN GONTAGT WITH PRESSURE TREATED HOOD I I
GONGRETE STRENGTH TO BESHALL
BE OF THE SAME MATERIAL ,AS THE I I
2500 (MIN.) P51 AFTER 25 D,AYS�
I
I
I
BRACKET TO AVOID GALVANIC, REAGTION. I I
I I
I I
I I
I
I
I
FOUNDATION VENTILATION
I I
I I
I I
EXI5TIN6 FOUNDATIONol I I
VENTED AREA : 152 sq. t.
4" XNGRETE SLAB I I
152 /150 1.01
PARTIAL PERIMETER 5" FOUNDATION HALL I I
I.01 / .59 : 1.14
5"x16" CONCRETE FOOTING I I
(2) 5"x16" FOUNDATION VENTS ✓
I
I
I
I I
I I
I I
I
I
I
L-------------------------------�
I I
I I
I I
I
I
---------
REV. # DATE: DESCRIPTION:
© ERIC KUZMA 2009
2x6 / \ 2x6— EX15TING 2x12
LEDGER LEDGER lirrRIM 05T
rV 51MF50N LU526 HANGERS
2x6 FLUSH I" ELEVATION
CHANGE
<
a FRAMED JOISTS
m .i IF.
o (RIP TO +/- 5" 2x6 (+/-
LEDGER
A SII N/ BOTTOM OF
------41'2"-
--3':421-'---
K-
2x6 R TERS
@ 24"G. ✓
P.T. 4X6 BEAM & POSTS
SET BEAM FOR FASCIA
TO MATCH HEIGHT OF ►"'
PORCH FASCIA
SECOND FLOOR
FRAMIN6 PLAN
56ALE: 11b' = 1'-0"
- - INFILUCD,
PREVIOUS
STAIR,
OPENING;
i
i
i
L J
EXI5TIN6 2x12 -101575
@ 16" o.c. TYR
(PLATFORM "FRAMING)
BLD 09 m0 1
DATE: I /7/09
SCALE: 1/4"= 1 '-0"
V14
W
co
A
\
Z
O
Q<
0
D
ILL 0
i
V
Z
`C
LL
-i
0
U
� o �
Z
1w --o0,
6,
E
LL"
°,
o
Lv
N Z E
L%%
Lu
8�: 0 u
LJJ
co"'
v 2
Lu �
� C c
E
� n
n w
d
w
Ly
F—
(/)z
�/ LL
J U ILL U
O
Z
L11
j
O
F—
V14
SHEET:
4
OF:
12
Q
0
\
Z
O
Q<
0
D
ILL 0
i
V
Z
`C
LL
-i
Z
ry
LL
�
IL
LL N
0
U
co
CIDM
O`
Q
O
LL
z0
~
ES
w
Ly
F—
(/)z
�/ LL
J U ILL U
O
Z
L11
j
O
F—
Q
>>
i M
0-
SHEET:
4
OF:
12
TYPICAL ROOF 5Y5TEM:
METAL ROOFING (TO MATCH EXISTING)
30# A5TM BUILDING PAPER
19/32 OR 5/8" GDX (NOT 055) SHEATHING;
2x10 DF #2 RAFTERS @ 24" 0G;
R-30 HIGH DENSITY FIBERGLASS BATT
IN5UL. W/ BAFFLE;
1/2" GYPSUM WALLBOARD
W/ LO'W-PERM PRIMER
EGGSHELL WALL PAINT (COLOR T.B.D.)
TYPICAL WALL CONSTRUCTION
SIDING: 'BRECKINRI06E' NO -GROOVE
HARDWOOD SIDING (TO MATCH EXI5TIN6)
EXT. TRIM: 5/4 STK CEDAR, TYP.
(( OLOR5 T.B.D. BY O'WNER)
15# BUILDING PAPER
1/16" 0.5.5. OR 1/2" GDX PLYWOOD
2x6 STUDS @ 24" c.c. (ADVANGED FRAMING)
R-21 FIBERGLASS BATT INSUL.
1/2" GYPSUM WALL BOARD W/
LOW PERM PRIMER
EGGSHELL WALL PAINT (COLOR T.B.D.)
IX6 WOOD BASE BOARD
TYP. GONG. FOUNDATION WALL
&" FOUNDATION WALL W/
OUTSIDE FACE TO HAVE APPROVED
WATERPROOF TREATMENT BELOW GRADE
TYP. GONG. WALL REINFORGING
#4 @ 12" O.G. HORIZONTAL
#4 @ 0" O.G. VERTICAL
TYP. FOOTING REINFORGING
(2) #4 CONTINUOUS BARS @
3" FROM BOTTOM OF FOOTING
(TIE VERT. WALL BARS ALTERNATELY
TO EACH HORIZ. FTG. BAR)
NOTES:
CONCRETE STRENGTH TO BE
2500 (MIN.) P51 AFTER 25 DAYS
FOOTING TO REST ON UNDISTURBED
501L � BE 12" MIN. BELOW GRADE
DETAILED 5EGTION
GOA
JV�: 51b" _ 1'-0o
CONTINUOUS VENTED RIDGE CAP
(2) 2x10 HF SELECT 5TRU6.
-' (LOCATE 50 A5 TO ALLOW PLENUM ABOVE
INSULATION TO REACH RIDGE VENT)
12 /r
(� 45 DF#I WINDOW HEADER
l\ ______ � (SET TO INSIDE
rn� 5URFAGE)
W_
0
0
LL_
- o
r -
r o
0
0
m
2/0x4/0
SKYLIGHT
(W/ WELL
PERP.@ TOP
PLUMB @ BTM.)
f LOFT FLOOR SYSTEM:
3/4" BAMBOO FIN15H FLOOR
3/4" GDX 5UBFLOOR, GLUED
56REWED TO J015T5
2x6 FLOOR JOISTS
@ 16" O.G., TYP.
R 5Y5TEM:
_OOR
GLUED
.5
J01575 @ 24" O.G.
R-30 (MIN.) HIGH DENSITY
BATT INSULATION
DATE:
1/7/09
TYPICAL FIRST INO
3/8"=1'-0"
REV. # DATE: DESCRIPTION:
HARDWOOD FIN
© ERIC KUZMA 2009
3/4" GDX SURF
XF
00
W
15GREWED TO
coco
R 5Y5TEM:
_OOR
GLUED
.5
J01575 @ 24" O.G.
R-30 (MIN.) HIGH DENSITY
BATT INSULATION
" PERF. DRAIN PIPE (HOLES DOWN)
SHEET:
6
OF:
12
DATE:
1/7/09
SCALE:
3/8"=1'-0"
REV. # DATE: DESCRIPTION:
© ERIC KUZMA 2009
00
W
coco
� o �
E
w ocy
''Zn
Lc w o^
V
N E
Z 6 N
Lo
L1J o 3 n
W
CoLu m
INSULATION BAFFLE
� o 1E
(MAINTAIN I" MIN. AIR5PACE)
_ �--
"' a a w
2x FRIEZE BLOCK W/ 56REENED VENT
n^ ,
SIMPSON H-1 HURRICANE TIE @ EACH RAFTER
_
lel/)
METAL DRIP EDGE
5 1/2" REDUCED RAFTER TAIL
K -LINE CONTINUOUS METAL GUTTER
DOWN5POUT5 (TO MAT( H RE5IDENCE)
-2 II 5/4x8 STK CEDAR FASCIA
Q�
(2) 2x6 TOP PLATE
LL]
Z
O
2x6 FIRE BLOGKING
(10'-0" MAX. GAVITY)
Lu
U
L d
NOTES:
U
6-5" TYP. WINDOW
o
HEAD HEIGHT
J
co
ALL 5TRUCTURAL FASTENING
o
PER SCHEDULE R602.3(1)
Ve
00
0
2x6 50LE PLATE
m LL
2x10 RIM JOIST ✓
amp
2x6 P.T. 50LE PLATE
>Q
1/2"XIO" ANCHOR BOLT W/ 1" MIN.
EMBEDMENT W/ 2x2x3/16" PLATE
w p
WA5HER TYP. @ 45" O.G. 3 @ 12" ✓
C W
FROM EA. END (MIN. 2 PER SILL)
O
U)
nnZ
TOP501L (SLOPE FIN15H GRADE 6" IN
11
C~/)
LL
M
FIRST 0'-0" AWAY FROM FOUNDATION)
Z
W J O
0
U ~
F R DRAINING GRANULAR 6AGKFILL
-�-�
O
Q — Lv
FILTER FABRIG
Q
0
M
" PERF. DRAIN PIPE (HOLES DOWN)
SHEET:
6
OF:
12
I-n �
1� Urn
b z
e�
M
r
{
O
z
ti
Q
3 1`
03 C IJ
ll
Fn O
71
c 4 P
rn �
rO
1—�
rn 63
V
0
x O
N rn rn W
IJ
o
(S' O
IJ
m
D
m
n
c
0
O
z
CS
N
O
10
o
N
m ADDITION
FOR:
.,
PROPOSED
NORTH
�T PT. DESIGN &
`�
>
m
T
-1
WALKER
T IMBERFRAME
N
ELEVATION
3410 CLIFF
STREET
3265 EDDY STREET
o
PORT TOWNSEND, WA 98368
'0
PORT TOWNSEND
WA 98368
Phone: (360) 379-3940
E-mail: erickuzma@rnsn.com
4
CITY OF PORT TOWNSEND
T PERMIT ACTIVITY LOG
PERMIT # DATE RECEIVED
SCOPE OF WORK:
0 1 1 ��'q /0 �l
DATE,
ACTION INITIALS
01 001
ENTERED INTO CHET
CHECKED FOR COMPLETENESS
an
d1pV
Zoning:
Setbacks OK?
S
Lot Size:
Building Size:
1 — '
Lot Coverage:
'3 O/c'
FAR OK?
Height OK?
Parking OK?
Critical Area?
Demo?
Historic Rev?
Notice to Title?
Lots of Record?
o�VoRTTBUILDING PERMIT
City of Port Townsend
Development Services Department
250 Madison Street, Suite 3, Port Townsend, WA 98368
(360)379-5095
Project Information Permit # BLD09-016
Permit Type Residential - Accessory Structure Project Name Residence Addition
Site Address 3410 CLIFF ST Parcel # 959700302
Project Description
Residence Addition
Names Associated with this Project License
Type Name Contact Phone # Type License # Exp Date
Applicant Walker Scott
Owner Walker Scott
Fee Information Project Details
Project Valuation $25,505.56 Dwellings — Type V Wood Frame 268 SQFT
Building Permit Fee 401.35 Units: Heat Type:
Plan Review Fee 50.00 Bedrooms: Construction Type:
State Building Code Council Fee 4.50 Bathrooms: Occupancy Type:
Technology Fee for Building Permit 8.03
Record Retention Fee for Building 10.00
Permit
Total Fees $ 473.88
Call 385-2294 by 3:00pm for next day inspection.
Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180
days. Work is verified by obtaining a valid inspection.
The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify
that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify
that I am the owner of the property or authorized agent of the owner.
S
Print Name "Ar 6e- �U l� �(/ Ar Date Issued: 03/25/2009
g Issued By: SWASSMGR
Signature 1�-re Date z J / Date Expires: 09/21/2009
Notice of City Development
Requiring Septic Approval
City of Port Townsend
o�VORT 70�y Or._6 wry/AI'1��1 Development Services Department
City Hall
U O _ � ( l`
(, j �� 250 Madison Street Suite 3
S Port Townsend, WA 98368
"`" (360) 379-5095 Fax: (360) 344-4619
To: Jefferson County Environmental Health Su ?-a 111 Y�-e—
Re: City Building Permit Involving Septic System: New Structure X� Existing Structure
Building permit BLD 0 9 — and/or Public Works Permit
Name of Legal Owner(s): SCS cua-11 k& -
&-
Property
Property Address: 7 D C� �;�,S�
Port Townsend, WA 98368
Phone Number: 3 U _ 2—/S-9
Zoning District: Parcel# L� �
— — 3 6
Legal Description: Addition <I S' Block
Lot(s) 3 —
Parcel size:
Description of Proposed Building(s): 9Vor Ofl �� �'' l vl — 2ha
Description of Any Existing Building(s): S1 1. CP_--
Bedrooms: Existing #L Pr op)sed# : Total # Bedrooms: _
Bathrooms: Existing # : 1 Proposed # : D Total # Bathrooms:
�--��
Building: Existing Sq. Ft: Proposed Sq. Ft: j 7�Z Total Sq. Ft: �_`
d � o�� ' f6 v FUD fPrt-"L� 6- Y Z2 6 7 �o I Ud
A site map and a floor layout pla is attached showing all existing and proposed buildings,
property lines, septic tank and drainfield location, and water line route. A $73.00 review 1'76
fee check is attached, payable to Jefferson County Environmental Health. V?
LAJ — // —/ e)-0 �
City DS taff Member Date
County comments: Date:
P:\DSD\Forms\Building Forms\Application-Septic Permit.doc
11/10/2009
AN ADDITION FOR: SCOTT WALKER
3410 CLIFF STREET, PORT TONN5END, NA 98368
PROJECT DATA:
NEN ADDITION
ZONING: R-1/
TAX PARCEL #: q5q-100-301 (302) (303)
LE6AL DESCRIPTION:
SECTION: 4, QTR. SECTION: NE 1/4,
TONN5HIP: 30 N, RANGE: IW.
HILLS ADDITION
BLK 3, LOTS 1-2,
EXI5TIN6 HOU5E
T FLOOR: 480 s.f.
IND FLOOR: 00 s.f. ✓
TOTAL PATIO 4 DECK AREA: 144 s.f.
DRIVEWAY d WALKWAY: 520 s.f. `/
VICINITY PLAN
PROPOSED ADDITION AREA:
15T FLOOR: 116 s.f.
2ND FLOOR: 48 s.f.
LOT COVERAGE 4 IMPERVIOUS AREA.
(FOR PARCEL #q5q-100-302)
LOT SIZE: 20,000 s.f.
TOTAL LOT COVERAGE (EXISTING 4
PROP05ED BUILDING FOOTPRINT):
656 s.f. or 33% (< 35% ALLOWABLE)
TOTAL IMPERVIOUS SURFACE: 1320 51.
or 6.6% (< 40% ALLONABLFE)
TH15 PROJECT SHALL COMPLY WITH
THE FOLLOWING CODE5: 2006
2006 W5EC, 2006 VIAQ
00 SITE
3STREET Y
(360) 51q-8288
——^ I — REV.N DATE:0 ERIC KIUZMA_2009
—
35th STREET
I
I
a �ITri
AN O
< N A O
>y °
A
rn O
r�
I
O
I o
SITE PLAN
SCALE: I'= 40'-0'
INDEX TO DRANIN65
(10'-0" SETBAGK)-
I
PARGELa 951-100-301 (LOTS IS 2)
LOT
01
O�
rn
�I
zsI
II Ex15TING
GRAVEL
PRIVEWAY
-------------'I---
PARGELa 959-100-303 (LOTS145)
LOT 8
o
ll0 rv8 •.u.WI 0
s.Fyy-r.
I�
IIS
LOT 1
I � Iz�dN II
�I _ _ _ _ _ LOT 3 _ _ _ _ _ LLOT b
ANK
I I
P RGEi 95 10d 02 (LOTS 3-6)
EMS G
1 D NFIELD
--!------- — —---------------! --
(1 '-0" SE AG OT 4 LOT 5
N PAIA 51' 4A" F
I HASTINGS AVENGE I
GEORGE
5 ROOF FRAMING PLAN 12 PERSPECTIVE VIEW5
6 DETAILED SECTION - A
NOTE TO 0ONTRACTOR5 b BUILDIN6 OFFICIALS
JAN 2
Of PORT 1
OSI)
I. THESE PLANS ARE INTENDED TO CONTAIN ALL THE INFORMATION
REQUIRID To DEMONSTRATE COMPLIANCE KITH APPLICABLE BUILDING
4 ZONING COOE5. IN THE CASE OF ANY INFORMATION WHICH APPEARS
TO BE LACKING, PLEASE CONTACT THE DES16NER IMMEDIATELY.
2. THESE PLANS CONTAIN THE MAJORITY OF INFORMATION REQUIRED
TO BUILD THE STRUCTURE A5 SHOW HOHEVER, IT 15 NOT POSSIBLE
TO ANTICIPATE EVERY PIECE OF INFORMATION NEEDED FOR CONSTRUCTION.
THE DE516NERHA5 MADE A COOP FAITH EFFORT TO STRIKE A REASONABLE
BALANCE BETHEEN PROV15ION OF INFORMATION 4 COST OF THE PLANS.
THE PLANS WILL INEVITABLY CONTAIN MINOR DISCREPANCIES 4 AREAS
LACKING IN SPECIFIC INFORMATION. DURIN6 THE COURSE OF CONSTRUCTION,
AS THESE AREAS EMERGE, THEY WILL REQUIRE ATTENTION S RESOLUTION.
THE BEST RESOLUTION OF THESE I55UE5 15 M05T OFTEN ACHIEVED THROUGH
A JOINT DEG1510N MAKING PROCESS INVOLVING THE ONNER(5)/DE516NER
4 CONTRAGTOR(5). BLD 0 9— 0 1 6
DATE: I f7109
SCALE: AS SHOWN
LU
z LLw
Ly
w m So
C) ::E
F— I—
d
SEND
W D
LU Z
c w
G Ln
O a LL 3
LL
O J U 0u-
O
0< 0
SHEET:
OF:
12
Q
I PROJECT DATA, SITE/ VICINITY PLANS
T DETAILED SECTION - B
3
c)
2 PROPOSED 15T FLOOR PLAN
8 PROPOSED l E5T ELEVATION
3 PROP05ED 2ND FLOOR PLAN
q PROP05M SOUTH ELEVATION
4 FOUNDATION/ 15T FLR. FRAMING
10 PROP05M EAST ELEVATION
31ST STREET
4 2ND FLOOR FRAMIN6
II PROP05ED NORTH ELEVATION
I HASTINGS AVENGE I
GEORGE
5 ROOF FRAMING PLAN 12 PERSPECTIVE VIEW5
6 DETAILED SECTION - A
NOTE TO 0ONTRACTOR5 b BUILDIN6 OFFICIALS
JAN 2
Of PORT 1
OSI)
I. THESE PLANS ARE INTENDED TO CONTAIN ALL THE INFORMATION
REQUIRID To DEMONSTRATE COMPLIANCE KITH APPLICABLE BUILDING
4 ZONING COOE5. IN THE CASE OF ANY INFORMATION WHICH APPEARS
TO BE LACKING, PLEASE CONTACT THE DES16NER IMMEDIATELY.
2. THESE PLANS CONTAIN THE MAJORITY OF INFORMATION REQUIRED
TO BUILD THE STRUCTURE A5 SHOW HOHEVER, IT 15 NOT POSSIBLE
TO ANTICIPATE EVERY PIECE OF INFORMATION NEEDED FOR CONSTRUCTION.
THE DE516NERHA5 MADE A COOP FAITH EFFORT TO STRIKE A REASONABLE
BALANCE BETHEEN PROV15ION OF INFORMATION 4 COST OF THE PLANS.
THE PLANS WILL INEVITABLY CONTAIN MINOR DISCREPANCIES 4 AREAS
LACKING IN SPECIFIC INFORMATION. DURIN6 THE COURSE OF CONSTRUCTION,
AS THESE AREAS EMERGE, THEY WILL REQUIRE ATTENTION S RESOLUTION.
THE BEST RESOLUTION OF THESE I55UE5 15 M05T OFTEN ACHIEVED THROUGH
A JOINT DEG1510N MAKING PROCESS INVOLVING THE ONNER(5)/DE516NER
4 CONTRAGTOR(5). BLD 0 9— 0 1 6
DATE: I f7109
SCALE: AS SHOWN
LU
z LLw
Ly
w m So
C) ::E
F— I—
d
SEND
W D
LU Z
c w
G Ln
O a LL 3
LL
O J U 0u-
O
0< 0
SHEET:
OF:
12
PROP05ED ADDITION
HOUSE
w
DATE: I n/09
SCALE: I/4"=1'-0"
REV. # DATE: DESCRIPTION:
0 ERIC KUZMA 2009,
W � it
ol
20'-0•
3 P
5'-6•
I
2'-6•
VIP
'
(wIsswP
� G " 5
W0
W
00 x
QY
F- N
2/6x4/6
Ll)
I ,
ILL
� LL
DOUBLE HIN6 I
Ll
W
U
F-
J 0 c
20 CFM
0
Q
OPENIN6 FRAMED
4/44/0
WINDOWS:
WALL PORT
H.W H. 1k� WINDOWI
OPENIN6
OR EGUAL. DOLOR TO BE WHITE.
OF:
WINDOW HARDWARE TO BE 5TANDARD. ALL
WINDOW5 AND DOLO5 TO HAVE AN NFRG -
FRAMED
12 1.
MO wINDoN
EX15TIN6
OFFIGE
O
(REMOVE
INTERIOR
WALL51
_ NO HANDRAIL/
A
OF FILE
GUARDRAIL REDO m
(2) l6x4/6
HARDWOOD I
IS
IFIR7ACEED
-E% i -AN 30'
DOJ E HAJG
I
ABOVE GRADE
r--------- ----
6� I.
-07
NFILLED
PREVIOUS
i
5
5TAIR
OPENING
PDXKET I
-
DOYPI
3/0 x b/8
POLL LII:
VL%
O
3'-3}'
2/b x 6/B
L 12 HINDER Tr_2E_A_0_5_4 14
UP
CL05ET1
RI5ER5, FLR. TO FLR. V-2'
EXISTING
0 36' GUARD RAIL d CONT.
-
dd
SHIP
6/6x4/B
HAND RAIL C 36' ABOVE
1
M N
5TAIR 1051N65, BOTH W
CONCRETE SLAB
BALU5TER5 W 4" MAX. G.AP
-TA—EW�
WINDER TREADS 5HALL HAVE
A 10" MIN. TREAD DEPTH
MEASURED .AT A POINT IT
3'-I'
I- 3 3'-I•
FROMNARROWER 510E d A
MIN . TREAD DEPTH OF b'
ELECTRIC
NEW METER
METER/PANEL
OPENING FRAMED
LOCATION I
MO WINDON
Vf ITI
SHEDROGF ABOVE .... �_
--
6 r .ARADOOR
11
n� 4-0 4,-0.
J
8'-0
20'-0'
PROP05ED FIRST
FLOOR PLAN
SCALE: 1/4• = 1'-0•
cSi1 = SIhOI�E.
11. I Ec %012.
w
Lv Z
a
0 d
W Ly
L0
O O
O -'
ry LL.
d
DATE: I n/09
SCALE: I/4"=1'-0"
REV. # DATE: DESCRIPTION:
0 ERIC KUZMA 2009,
W � it
ol
3 P
Z
z
VIP
'
(wIsswP
� G " 5
W0
W
00 x
QY
F- N
O
Ll)
I ,
Lv Z
a
0 d
W Ly
L0
O O
O -'
ry LL.
d
BLD09 -0 1 G
c
� I
M
ol
olQ
W0
W Z
QY
F- N
O
Ll)
I ,
ILL
� LL
Z
O
Ll
W
U
F-
J 0 c
0
Q
SHEET:
WINDOWS:
WIN901,15 TO BE MIL6ARD VINYL,
OR EGUAL. DOLOR TO BE WHITE.
OF:
WINDOW HARDWARE TO BE 5TANDARD. ALL
WINDOW5 AND DOLO5 TO HAVE AN NFRG -
12 1.
BLD09 -0 1 G
I
1/4' = I'-0'
f.
�J 5
S
PROP05ED ADDITION
}
HOUSE Y DATE: In/09
SCALE: 1/4"= 1'-0'
REV. # DATE: DESCRIPTION: �j
O ERIC KUZMA 2009
� W
Z ion
LL
(n W o 3 V
W CO
a
~ A2
4
O
5t4x4/C
FIX°D
ll 1
F 5
ARD VINYL,
0 BE WHITE.
.0 BE 5TANOARD. ALL
WINDOWS AND DOORS
TO HAVE AN NFRO
U -VALUE OF 0.35 OR LOWER. -
BLD09 "01 e
Z
O Z
U a
Ln a
w 0
O 0
d L1
O
ry
d
co
10
co
O`
Q
W
W 7 -
LU
cn
O N j
z
LL [Y LL
Z W L
O d
J Oo
o I-
co Ort
SHEET:
3
OF:
12
� --� �- V� f
De
Residential Building Permit Application
t Services
250 Madison Street, Suite 3
Port Townsend WA 98368
Phone: 360-379-5095
Fax: 360-344-4619
www.cityofpt.us
Project Address:
3`rly C1;
Legal Description (or Tax #):
Addition: 14J
Block: 3
Office Use Only
Permit umbe
BLD_ = 0 L�
Associated Permits:
Zoning: AIA
Parcel # of S q 700 3QZ
_
Lot(s):_ 3_i_S _�
Project Description:
➢ Applications by mail must include a check for initial plan review fee of $150 for projects valued over $15,000.
See Page 2 for details on plan submittal requirements.
Lender Information:
Lender information must be provided for projects
over $5,000 in valuation per RCW 19.27.095.
Name:
Project Valuation: $
Building Information (square feet):
1 st floor ! 7 y Garage:
2nd floor _ 17 /v Deck(s):---
V floor Porch(es):_L c
Basement: Is it finished? Yes No
Carport:_—____ Other:______
Manufactured Home ❑ ADU ❑
New AdditionK Remodel/Repair ❑
Total Lot Coverage (Building Footprint):*
Square feet:_ G 7 4o _ %_ 7 __
Impervious Surface:*
Square feet: 10'01_ *Total existing & proposed
What year was the structure built? / 10 7 -
If work includes demolition, see Page 2.
Any known wetlandert3[Ll_!�
Any steep slopes (>P -P/4) L5 Q
Property Owner/Applicant:
Name:_ 3 .0 4J, Iker
Address: 3 y1 u CI;W • _ _ _
City/St/Zip: leo.♦ To.�hsrL4 Le).A _ggTt.B
Phone: _34 o— 3(DI- Z I.Sg _
Email:_ L---A%1ker3 ol�r�..tl.ls. ►, e} ----
Contact/Representative: —F
Name: e r
Address:
City/St/Zip:
Phone:___
Email:
Contractor: )T Same as Owner
Name:
Address:
City/St/Zip:______
Phone:
Email:
State License #: ---Exp:
City Business License
I hereby certify that the information provided is correct, that I am either the owner or authorized
and that all activities associated with this permit will be in accordance with State Laws and the
Print Name: S�-�` l%Ikceiv-
Signature:
Page 1 of 2 7/31/2008
behalf of the owner
sep�l �uTigal .Cod .
8 . $JY OF PORT TOWNSEND
O 7 DSD
O�?ORT City of of Port Townsend
ys Development Services Department
i 250 Madison Street, Suite 3
Port Townsend, WA 98368
(360) 379-5095 Fax: (360) 344-4619
Washington State Energy Code (WSEC)
2001 Residential Construction Checklist
Complete this form in addition to WSEC forms. Please answer the following questions:
TYPE OF PROJECT:
❑ New construction, or addition over 750 square feet
Must meet whole house and spot ventilation requirements, and show full WSEC compliance as
a stand-alone project. A detached, habitable structure such as an Accessory Dwelling Unit
regardless of size must also meet these requirements.
House addition under 750 square feet
Possible trade-offs are allowed with the existing building for WSEC compliance, such as
increasing ceiling insulation. See WSEC component performance forms.
NOTE: A house addition less than 500 sq. ft. does not require whole house ventilation.
Spot ventilation is still required!
TYPE OF HEATING — Please check all that apply:
Electric
❑ Wall Heater *Baseboard ❑ Forced Air Furnace ❑ Radiant Floor (Boiler) ❑ Other
Non -Electric:
Propane: ❑ Radiant Floor/Baseboard (Boiler) ❑ LPG Stove ❑ LPG Furnace ❑ Other LPG
❑ Heat Pump ❑ Oil Furnace ❑ Woodstove (can only be used as secondary heat source)
VAPOR RETARDERS:
Vapor retarders shall be installed toward the warm surface as represented below. Select one
option for floors, walls, and appropriate ceilings:
9 Floors:
❑ Plywood with exterior glue
'S Poly plastic (greater than or equal to 4 millimeter thick)
❑ Backed batts
• Walls:
❑ Poly plastic (greater than or equal to 4 millimeter thick)
❑ Face -stapled, backed batts
M Low -perm paint
• Ceilings:
❑ Not required where ventilation space averages greater than or equal t(
insulation
❑ Face -stapled, backed batts
❑ Poly plastic (greater than or equal to 4 millimeter thick)
Low -perm paint
SEE BACK
PADSD\Department Forms\Building Fonns\Application-Residential Energy Code Checkhi.doc
Page 1 of 1
JAN 2 9 2009
CITY Of PORT TOWN') END
DSD
WASHINGTON STATE VENTILATION AND INDOOR AIR QUALITY (2000 Code):
Type of ventilation used throughout the house: ❑ HVAC Integrated Option ❑ Exhaust Option
Whole House Fan for "Exhaust Option":
• In what room is your whole house fan located?
• What size is the whole house exhaust fan? ❑ 50-75 CFM (1-2 bedroom house)
❑ 80-120 CFM (3 bedroom house)
❑ 100-150 CFM (4 bedroom house)
❑ 120-180 CFM (5 bedroom house)
Note: the whole house fan shall be readily accessible and controlled by a 24-hour clock timer
with the capability of continuous operation, manual and automatic control. At the time of final
inspection, the automatic control timer shall be set to operate the whole house fan for at least 8
hours a day, and have a sone rating at 1.5 or less measured at 0.10 inches water gauge.
Spot Ventilation:
Source specific exhaust ventilation is required in each kitchen, bathroom, water closet, laundry
room, indoor swimming pool, spa and other rooms where excess water vapor or cooking odor is
produced. Bathrooms, laundries or similar rooms require fans with a minimum 50 cfm rating at
0.25 inches water gauge; kitchens shall have a fan with a minimum 100 cfm rating at 0.25 inches
water gauge.
Outdoor Air Inlets:
Outdoor air shall be distributed to each habitable room by means such as individual inlets,
separate duct systems, or a forced -air system. Habitable rooms include all bedrooms, living and
dining rooms but not kitchens, bathrooms or utility rooms. Where outdoor air supplies are
separated from exhaust points by doors, undercutting doors a minimum of 1/2 inch above the
surface of the finish floor covering, distribution ducts, installation or grilles, transoms or similar
means where permitted by the Uniform Building Code. When the system provides ventilation
through a dedicated opening, such as a window or through -wall vent, these openings must:
• Have controlled and secure openings
• Be sleeved or otherwise designed so as not to compromise the thermal properties of the wall or
window in which they are placed.
• Provide not less than 4 square inches of net free area of opening for each habitable space.
What type of fresh air inlet will be installed? (See figure below)
❑ Window Ports
X"Wall Ports
PADSD\Department Forms\Building Forms\Application-Residential Energy Code Checklist.doc
Page 2 of 2
Before''hiring
a contractor
If you are a consumer interested in having work done by a contractor, this brochure can help
you by:
• Explaining how the Washington state contractor registration program works.
• Describing how the contractor registration law protects consumers.
• Outlining the requirements for contractors.
Washington state law requires all contractors
to be registered. General contractors must
maintain a $6,000 bond and specialty
contractors must maintain a $4,000 bond.
(Specialty contractors are those who participate
in no more than two trades and do not -
subcontract work to other contractors.)
It is against state law for any contractor to
submit bids or perform any contracting work
without being registered with the Department
of Labor and Industries. It also is illegal for
contractors to advertise without including their
12 -character contractor registration number in
the advertisement.
The contractor registration law exists to
protect consumers from incompetent and/or
fraudulent contractors.
Requiring contractors to be bonded gives
consumers some financial protection against
unsatisfactory or incomplete work. Dissatisfied
consumers may take civil action to obtain
restitution by taking action against a contractor's
bond in Superior Court.
The law also requires contractors to carry
insurance for property damage and public
liability. It also ensures that contractors have a
current Unified Business Identifier (UBI)
Account Number and Federal Employer
Account Number.
Any correspondence you send to a contractor
should clearly state that bids will not be accepted
unless the contractor provides a valid registration
number.
While the law does not guarantee perfect . .
performance, it improves the likelihood that
the contractor does competent work.
A maximum I
meanor infraction c,
tractor who perform
out being registered
• :.I: 'Make sure your contractor`is,:proPerly
registered
2 Be wary. of contractors who ask you -to .: '
pick up the building.pe'rmit ,3
3 -Plan your project carefully, including
detailed'plans,'if necessary- `
4:. Tryto;get atleast thiee written bids -on,
each job:
5: ; ;Ask contractors for,references:
6.,: Askwhatinconveniences:mightarise.
7 Obtain a written contract: .'
8;,: 1yfake sure you understan&the terms
before, You, sign anything
9 Be cautious about paying for'work not yet'
completed.
10. Put all change orders in writing. ;
11. Make frequent inspections and : con. sult
-your local building department.'
1!.,:A9vid making final payment until you
have received a lien release: from
suppliers and subcontractors:
When hiring an unlicensed contractor and acting
as your own contractor:
1. You are responsible for the medical and time
loss costs of employees injured while working
on your project.
2. You may be liable for all unpaid taxes.
3. Your homeowner's insurance may not cover
work done by an unlicensed contractor.
4. The law requires complete disclosure of all
work that has been done on your home, if you
resell. You may be required to do work over
again that has been done without permits, or
inspections. Non -disclosure can lead to civil
action being taken against you.
5. You may be placing yourself and your family in
a life-threatening situation, especially when hir-
ing unlicensed people to install plumbing, elec-
trical wiring, heating systems or wood stoves.
6. Suppliers can place a lien on your home for
non-payment of materials by your contractor.
7. Unpaid workers can place a lien on your
property.
8. When problems arise, your only recourse is a
lengthy and costly civil action — if there are
any assets of value to attach, and if you can
find the contractor.
Contractors are required to carry at least
$20,000 in property damage insurance coverage
and $100,000 in bodily injury or death insurance.
You are encouraged to verify the contractor's
insurance coverage with his or her agent, as the
department's records may not reflect current
coverage.
The Labor and Industries contractor registration
information line
1-800-647-0982
operates weekdays from 8 a.m. until noon and 1 to
5 p.m., excluding state holidays. The information
line allows you to check whether commercial and
resi-dential contractors are registered and properly
bonded.
Our staff can tell you if the contractor currently
is registered, if action against the bond is pending,
or if legal acton has been taken against the
contractor's bond in the past.
We also can tell you how long a contractor has
been registered.
Labor and Industries is an Equal Opportunity and Ajjgrmative
Action employer. The department complies with all federal rules and
regulations and shall not discriminate on the basis of race, color,
national origin, sex, creed marital status, sexual orientation, age,
religion or disability as defined by applicable state and/or federal
regulations or statutes.
OWNER SIGNATURE
O� VORr TOw
u Receipt Number: 09-0194
genpmtrreceipts Page 1 of 1
Receipt Date:
03/25/2009
Cashier: SWASSMER Payer/Payee Name: WALKER SCOTT
Original Fee
Amount
Fee
Permit #
Parcel
Fee Description
Amount
Paid
Balance
BLD09-016
959700302
Building Permit Fee
$401.35
$401.35
$0.00
BLD09-016
959700302
State Building Code Council Fee
$4.50
$4.50
$0.00
BLD09-016
959700302
Technology Fee for Building Permit
$8.03
$8.03
$0.00
BLD09-016
959700302
Record Retention Fee for Building Per
$10.00
$10.00
$0.00
Total:
$423.88
Previous Payment History
Receipt #
Receipt Date
Fee Description
Amount Paid
Permit #
09-0058
01/29/2009
Plan Review Fee
$50.00
BLD09-016
Payment
Check
Payment
Method
Number
Amount
CHECK
1596
$ 423.88
Total: $423.88
genpmtrreceipts Page 1 of 1
BLD09-016
CHECK
959700302
1567
Plan Review Fee
Total:
$ 50.00
$50.00
Receipt Number:
$50.00 $50.00
Total: $50.00
$0.00
genpmtrreceipts Page 1 of 1