HomeMy WebLinkAboutBLD97-135City of Port Townsend Po TownsendeWA 98368
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
• THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Ca11385-2294 For Inspection
Site Address: 343 33RD
Parcel No: 991100006
Project:
-CONTRACTOR/OWNE
FRED KIMBALL
151 FREDERICK STREET
PORT TOWNSEND, WA 98368
Issued: 1114/97
Lot: Block:
PERMIT # BLD97-00135
WNE
LEONARD MANDELBAUM
PO BOX 25526
SEATTLE WA 98125
Residential -Construction of a new house with 2341.5 square feet of living space, 151.5 sq. ft. of porches, 75 sq. ft. of
decks and a 64 sq. ft, garden shed.
City Contact: JLZ Construction TypelOcc UselOcc Load
Type of work: NEW Construction Occupancy
Type of use: SF Type 1: SN Group 1: R-3 Load 1: 8
Census Category: 101 Type 2: Group 2: Load 2:
Estimated Value: 5175,000.00
Type 3: Group 3: Laad 3:
Zoning: PUD
SI Code: Type 4: Group 4: Load 4:
SPECIAL CONDITIONS/RESTRICTIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
Inspection Date Inspector Inspection Date Inspector
Insp-See Special Conditions # Insp-See Special Conditions
Insp-See Special Conditions ~ Insp-See Special Conditions
TEMP EROSION & SDM'T CON Insp-See Special Conditions #~ ~~• / 'q7 t2S
Insp-See Special Conditions ~~ -Stem Wall ~:
GROUNDWORK PLUMBING I I i ~ , -Forms
FOOTINGS ` C ~ eh C -Reinforcement
-Setbacks ~ -Anchor Bolts
-Footings ~ -Waterproofing
-Forms SLAB
-Reinforcement Insp-See Special Conditions ~
-Porch/Deck Bay Piers ~ -" -Monolithic Slab/Fdn ~f/Cp
-LIFER -Interior Footing
w .
DATION f C~. ~ ~f -Insulation
U
Call 48 hours before you dig for utility line locates
1-800-424-5555 ~ ~ rl f~l.l/~L~~~~I
Page 1 of 4 ©~ ~ ~~-
City of Port Townsend P rtrow~~~d wasases
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8~ APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME •
Call 385-2294 For Inspection
Site Address: 343 33RD
Parcel No: 991100006
Project:
Issued: 11/4/97
Lot: Block:
PERMIT # BLD97-00135
Inspection Date Inspector Inspection Date Inspector
-Anchor Bolts S-f3W~ -Alternate Braced Wall Panel 5/J8~ y a.$ ~`~$ (,
-Alt BWP Holdown Hdwr yygp -Ceiling
FLOOR FRAMING -Roof
Insp-See Special Conditions #8 -Attic Venting
-Joists -Windows: Egress
-Blocking -Window UValue - ~
-Int. Braced Wall Supports -Window Safety Glazing
-Treated Wood to Concrete -Air Seal
-Anchor bolts & Washers -Fresh Air Intake (Wall Ports)
PLUMBING -Door U Value ~-
Insp-See Special Conditions ¢~9 -Fire Blocking
-Rough-In (D-V-T & Cln Outs) -Weather Resistive Barrier ~
-Water Supply INSULATION 'o
-Gas Supply ~ jC. ~ ~ .t b 6 Insp-See Special Conditions ~~~,
-Hose Bibs (bckflw pro. regd) -Slab (R10)
-Pipe Insulation -Wall (R-22)
-Water Heater -Ceiling (R-38) `r
-Seismic Restraint -Ceiling (R-30)
MECHANICAL -Baffles
-LPG Heater VAPOR BARRIER
-Whole House Fan (.L o k,,( G -Paint
-Souroe Specific Fan ~'~ -n't~ DRYWALL NAILING aY , S~
-Environmental Air Exhau -Walls
FRAMING ~ L a r ~ ~ -Ceiling
{nsp-See Special Conditions ~f ~Q -Interior Braced Wall Panels
Insp-See Special Conditions ,~~~ -Enclosed Space Under Stairs
-Walls DRAINAGE
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
J
City of Port Townsend
-~ Building and Community Development
540 Water Street
Port Townsend, WA 98368
BUILDER'S PERMIT AND INSPECTION RECORD
• THIS CARD & APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 343 33RD
Parcel No: 991100006
Project:
Inspection Date Inspector
Insp-See Special Conditions ~~3
-Per Master Plan
FINAL
Final-House Number
Final-Plumbing
Final-Mecha nicallHeating
Final-Insulation Certificate
Final-Vapor Barrier Cert.
Final-Smoke Detectors
F' I-Public Works Sign-Off
LPG (Fire Dept.) rf y~ ~~ ~~ .
Final -Building
Issued: 11/4!97
Lot: Block:
PERMIT # BLD97-00135
~S
SPECIAL CONDITIONS !RESTRICTIONS
1 . Outdoor construction activities shall be limited to the hours of 7:00 a.m. to 6:00 p.m. Monday
through Friday and prohibited on weekends.
2. All elements of braced wall panels (BWP, ABWP 8 IBWP) require inspection pricrto cover.
3. TESC: Contractor shalt use Best Management Practices to control erosion during construction
including but not limited to : graveled construction entrance, silt fencing, covering exposed
soils, etc.
4. FOUNDATION: Interior Braced Wall Panel (IBWP) locations require anchor bolts at 4' o.c..
5. FOUNDATION: See sheet 6/6 of plans for PHD 5 holdown locations.
6. FOUNDATION: See sheet 5l6 of plans for horizontal anchor bolt wood-to-concrete wall
connections.
7. SLAB: Monolithic slab for garden shed; all elements of alternate braced wall panels require
inspection prior to cover.
8. FLOOR FRAMING: See sheet 6/6 for second floor PHD2 holdown connection locations.
9. PLUMBING: If water pressure exceeds 80 psi, pressure reducing valve required.
10. FRAMING: See sheet 6/6 for specified nailing of holdown wall panels: Sd @ 4" o.c.
FRAMING: See sheet 4/6 for studio roof framing: 2 x 8 construction @ 12" o.c.
INSULATION: Below grade walls require R-21 insulation.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
City of Port Townsend 540 Water Street
Port Townsend, WA 96366
Building and Community Development
BUILDER'S PERMIT AND INSPECTION RECORD
THIS CARD 8. APPROVED PLANS MUST BE ON CONSTRUCTION SITE AT INSPECTION TIME
Call 385-2294 For Inspection
Site Address: 343 33RD Issued: 1114197
Parcel No: 991100006 Lot: Block:
Protect: PERMIT # BLD97-00135
SPECIAL CONDITIONS /RESTRICTIONS
13. 6RAINAGE: Contractor shall ensure that stormwater run-off is directed to approved Rosewind
drainage system.
GENERAL CONDITIONS
1. A separate electrical permit is required for any electrical work.
2. Reinspections are required after any corrections are complete.
3. Final Inspections and approvals are required prior to occupancy.
4. All building permits expire if no progress has been made within six months, or if no inspections have
been made by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS
Call 48 hours before you dig for utility line locates
1-800-424-5555
•
t
Page 4 of 4