Loading...
HomeMy WebLinkAboutBLD06-225 • • City of Port Townserd Development Services Department 250 Madison Street,Suite 3 Port Townsend,WA 98368 Phone(360)379-5095 Fax(360)3444619 CITY OF PORT TOWNSEND PERMIT AND INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 by 3:00 PM for Next Day Inspection Permit Number BLD06-225 Issued 12/13/06 Parcel Number 101351001 Job Address 200 Battery Way, Bldg 353 Zoning P/OS Occupancy V/B Nature of Work Install Fire Alarm System Use of Building Rental Owner Washington State Parks Contractor Isaacson Electric, Inc. ****See attached Fire Department memo dated 12/11/06**** Site Inspection Inspector_? Mounting Heights-manual device mounted 42-48 Date /x/1 7a inches above floor System Tests Inspector 1 L/r#1' Annunciation panel and Controls lock-in Date e& Duct smoke detector activation signal Acceptance Tested by Code Official Contractor's Material & Test Certificate Inspector QV Date As-Built Plans filed with Owner& Plan Box FACP Inspector j//4 (24 x 36 maximum format) Date Fire Department Final Inspection Approval Inspects Date y Page 1 of 1 Permit#BLDO6-225 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor& Indistries contractor's registration number and a City business license.Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 3. Re-inspection is required after inspection report corrections are completed. 4. Revisions require submittal& approval prior to making changes in the field. Contact the Development Services Department @ 379-5095 prior to making changes to the approved plans. 5. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. //9 / 7 Applicant Signa re Date Page 2 of 2 • Thomas L. Aumock Aumock Designworks Consulting Fire Code Official 2303 Hendricks Street,Port Townsend,WA 98368 (360)385-3938 Email:taumock@cablespeed.com Cell:(360)643-0272 FIRE ALARM SYSTEM PLAN REVIEW MEMORANDUM TO: Jan Hopfenbeck,Plans Examiner, DSD FR: Tom Aumock,Consulting Fire Code Officia DT: 11 December 2006 RE: BLD06-225,Fire Alarm System,Fort Worden State Park,Bldg.353 This code official is in receipt of the set of plans and equipment specifications for the above-referenced proposal from your office. The above-reference proposal was reviewed relative to the International Fire Code [I.F.C.], 2003 Edition, and Washington State Amendments, and the following constitutes this code official's findings and determinations based upon the plans of record submitted. Findings,Determinations,and Requirements 1. The proposal was reviewed as a Group R occupancy; and, 2. An automatic fire detection alarm system is a required installation for this occupancy under Section 907 of the International Fire Code; and, 3. The fire alarm system is found to be designed by, and shall be installed by, a licensed alarm technician conforming to the provisions of National.Fire Code 72 and related sections;and, 4. Manual fire alarm devices shall be mounted at least 42 inches and not more than 48 inches above the floor[IFC 907.4.2]; and, 5. The basement main floor support beam exceeds the Code depth threshold that requires that a smoke detector be placed for each"area"created thereby. The added smoke detection device is approved for the FACP coverage in that area. 6. The annunciation panel and associated controls shall lock-in until the system is reset and shall not be canceled by the operation of an audible-alarm silencing switch[IFC 907.9.1];and, 7. The system may be monitored by an approved remote agency [IFC 907.15]; and, 8. The fire alarm system shall be acceptance-tested in the presence of an approved code official [IFC 907.17];and, 9. A formal confidence test report [Approved City of Port Townsend form attached] shall be provided for this system after satisfactory acceptance testing, and filed with the City building permit and the building owner[IFC 907.18];and, C:\Documents and Settings\Tom\My Documents\Businees\City Contract\Plan Review&Correspondence\BLD06-225 Fort Bldg.353 FA System_doc12/11/06 10. A complete set of "as-bl�ilt" drawings of the completed system shbe provided to the building owner[IFC 907.19]. Any other applicable or relevant sections of said Code not covered herein shall nonetheless apply to this proposal. 1.0 hours time was logged in the review of this proposal, and 0.75 hour was logged in the initial system inspection. Final inspection should log an additional 0.75 hour. It is the administrative determination of this plan examiner that the proposal be approved subject to the aforesaid requirements. Two sets of approved plans and specifications are to be returned to the applicant together with the formal building permit. Attachmenst: 1. Contractor's Material&Test Certificate 2. Plan Review Checklist C:\Documents and Settings\Tom\My Documents\Business\City Contract\Plan Review&Correspondence\BLD06-225 Fort Bldg.353 FA System.docl2/11/06