Loading...
HomeMy WebLinkAboutBLD06-116± Development Services Department 250 Madison Street, Suite 3 Port Townsend, WA 98368 Phone: (360) 379 -5095 Fax: (360) 344 -4619 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE For Next Dav Inspection Call 385 -2294 Before 3P.M. Permit Number: BLD06 -116 Issued: 07/25/2006 Parcel Number: 955- 900 -034 Job Address: 2123 Shasta Pl. Zoning: R -I Type: V -B Occupancy: R -3 Nature of Work: Construct 2 story single- family Residence - Lot #34 Owners: KCCHA - Whippl e Contractor: Owner GENERAL CONDITIONS APPLY — SEE LAST PAGE SEPARATE PERMITS RE UIRED: Electrical — Contact Labor & Industries @ 360 -417 -2702 NOTE: ACQUAINT YOURSELF WITH THE LISTED REQUIRMENTS TO RECEIVE FINAL BUILIDNG INSPECTION PRIOR TO THE START OF CONSTRUCTION AND PRIOR TO YOUR REQUEST FOR FINAL INSPECTION. * ** All elements of engineering including holdowns, framing, nailing and other engineering connections require inspection prior to cover. * * * 1?Fn1Tr121FD 1IVCPF.CT1nXV% APPROWD DATE TEMP EROSION & SEDIMENT CONTROL — call Francesca at 385 -2294 for inspection See General Condition No. 2 Silt Fence as needed Gravel drive off mat to restrict sediment from leaving the site; 4" not required Wheel wash as needed FOOTINGS Setbacks — 10' from Shasta Pl. p /1, 5' from side p /1's, 10' from rear p /l. Footings Forms Reinforcement UFER Ground (tied to footing rebar steel) Interior Pads Call 48 hours before you dig for utility line locates 1- 800 -424 -5555 Page I of 5 REQUIRED INSPECTIONS Permit #BLD06 -116 FOUNDATION WALLS Reinforcement Foundation Vents Hold Downs Anchor Bolts & Washers Holdowns — must be tied in place at time of inspection; no wetsticking GARAGE SLAB Floor to be sloped towards garage door opening for drainage FOUNDATION DRAIN Stormwater Master Plan requires directing water to street drainage facilities; applicant will install 6" pipe in ROW outside of pavement for connection to street catch basin and tight line 4 inch pipe from homes for both foundation drainage and roof run -off to direct stormwater to catch basin. Must a inspected prior _ r to covering ditch & pipe PLUMBING: Rough -In (D -V -T & Clean outs) Water Supply Water Hammer Arrester (on dishwasher, ice maker & clothes washer) Hose Bibs (backflow protection required) Pipe Insulation (R -3) Pressure .Reduction Valve required Water Heater Seismic Restraint — strap tank @ 1/3 points Pressure relief valve drain to exterior, terminate 6" — 24" above ground Expansion tank Licensed Plumbing Contractor's Signature & License Number: Sign here FLOOR FRAMING CALL FOR INSPECTION BEFORE COVER Joists Double joists/Block under Braced Walls --- double BCIs require faller block Girders Posts Hangers Block joists ends & at intermediate supports Positive Connections Treated Wood to Concrete Pressure treated plate connections Call 48 hours before you dig for utility line locates 11- 800 - 424 -5555 Page 2 of 5 REQUIRED INSPEC.TIO S 1 J Permit #BLD06 -116 SHEAR WALL NAILING (Inspection and approval required prior to cover — may require several inspections) — See plans for appropriate shear wall details. Standard Braced Wall Panels — exterior panels may be placed vertically or horizontally. Interior panel sheathing shall be placed vertically. ABWP 1s` story of 2 requires two inspections; vertically sheathed on both sides with structural sheathing. SW -1 SW -2 requires structural sheathing to be placed vertically. WINDOW FLASHING/BUILDING PAPER Inspection of window flashing required prior to cover with building wrap; wrap shall be lapped per code and manufacturer's instructions at vertical and horizontal joints and under window flashing at bottom of window MECHANICAL Whole House Fan W/ 24 hour timer; window or wall ports required Kitchen/Bath/Laundry Fans Environmental Air Exhaust ducting (w/ back draft dampers), Insulation (R -4) (on ducting in unheated space) FRAMING — all members and connections require inspection prior to cover Fasteners han ers etc. in contact with treated material must be hot ditzyed galvanized Walls Headers Rafters (hurricane clips) Trusses Roof Sheathing Joists (hangers) Blocking Stairs Roof Venting — eave and ridge vents Windows - escape Smoke detectors (bedrooms, outside bedrooms and each floor) Safety Glazing Windows U factor - .40 or better Doors U- factor - .20 or better NFRC window sticker must be on window, skylights & doors at time of inspection Air Seal Fire Blocking Weather Resistive Barrier Call 48 hours before you dig for utility line locates 1 -800- 424 -5555 Page 3 of 5 0 RVOITIRED INSPFCTIONS Permit #BLD06 -116 APPROVED /DATE INSULATION Floor (R -30) Walls (R -21 Attic (R -38; blown in requires thickness and R -value markers installed for every 300 feet, facing attic access, affixed to trusses, and marked with thickness of installed insulation with numbers a minimum of I inch) Vapor Barrier: paint for walls and ceiling Baffles DRYWALL SEE PLANS FOR SHEETROCK ORIENTATION ON SHEAR WALLS Garage/House Separation —from plate to peak at common wall per plans or, with architect's permission, on walls and ceiling ofgarage (no attic access allowed in garage if sheetrock is not installed the full height of the common wall) PUBLIC WORKS FINAL — MIP06 -060 Public Works Sign -Off (prior to building final) FINAL Parking — 2 space required House Numbers — 5" minimum Plumbing Mechanical /Heating Vapor Barrier Paint Certificate Insulation Certificate Smoke Detectors Final — Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on -site and inspected prior to beginning construction; call 385 -2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights -of -way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. Call 48 hours before you dig for utility line locates 1- 800 - 424 -5555 Page 4 of 5 0 Permit #BLD06 -116 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re- inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385 -2294. A minimum of twen -four hours notice is re wired. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non- residential project. 8. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379 -5095) prior to making changes to the approved plans. 9. POST THIS PERMIT ON -SITE WITH THE APPROVED PLANS. zz- APPLICANT SIGN URE OATE Call 48 hours before you dig for utility line locates 1- 800 - 424 -5555 Page 5 of 5 0 0 ponrro� CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT a LNSPECTION REPORT For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. / DATE OF INSPECTION: 1 �z r'-6 / PERMIT NUMBER: SITE ADDRESS: 21-4,5 PROJECT NAME: /a CONTRACTOR:f�� CONTACT PERSON: K/� PHONE: TYPE OF INSPECTION: /�iQl..• 4 � ❑ APPROVED ~', ❑ APPROVED WITH ❑ NOT APPROVED CORRECTIONS Ok to proceed. Corrections will be Call for re- inspection before �- checked at next inspection proce ding. Inspector Date ' Approved plans and permit card must he on -site and available at time of inspection. A re- inspection fee may be assessed if work is not ready for inspection. 69fE912010 21:36 1360732 P.O. Box♦*" insulation Certiricate Of slow It La-r 3 PAGE 01 ate. i 0 p�poRTTQ� CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT " INSPECTION REPORT For inspections, call the Inspection Line at 360- 385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: ��� PERMIT NUMBER: SITE ADDRESS: a2. I j s5 knas` m - PROJECT NAME: CONTRACTOR: CONTACT PERSON: Q r\ PHONE: TYPE OF INSPECTION: G ❑ APPROVED ❑ APPROVED WITH CORRECTIONS Ok to proceed. Corrections will be checked at next inspection 7 NOT APPROVED Call for re- inspection before proceeding. Inspector ALR—Y. Date 2 k� 0, < < Approved plans and perr�2it Gard musThe on -site and available at time of inspection. A re- inspection fee may be assessed if work is not ready,for inspection. �3q i... i_..I 4 I BUILDING OWN R I/✓f/� Gr ADDRESS_ PLUMBING CONTRACTOR CITY OF PORT TOWNSEND L ELOPMENT SERVICES DEPART&T 181 Quincy Street, Suite 301A, Port Townsend WA 98368 1PLUMBING CERTIFICATION PRESSURE TEST PERMIT # ) tk DATE OF TEST LICENSE # GROUND WORK ROUGH -IN PLUMBING FINAL DWV Air PSI Water ! F Head Time Minutes WATER SERVICE Air 75 PSI Water Working Pressure Time Minutes NOTE: TESTING REQUIREMENTS (SECTION 318 UNIFORM PLUMBING CODE) MINIMUMS: Water Test — 10' Head — 15 Minutes Test at Working Presure Air Test — 5# PSI — 15 Minutes 50# PSI — 15 Minutes I hereby certify the information provided above is the result of the Plumbing System pressure test conducted by the undersigned at the indicated address and date. Misrepresentation of this certification is a gross misdemeanor under RCW.9A.72.04 subject to a two -year statute of limitation. VISUAL SYSTEM INSPECTION IS REQUIRED BEFORE COVER. I A Signature C r Date CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT M s INSPECTION REPORT Ewa For inspections, call the Inspection Line at 360 - 385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: 4 a PERMIT NUMBER: SITE ADDRESS: PROJECT NAME: CONTRACTOR: �- CONTACT PERSON: PHONE: TYPE OF INSPECTION: r PPROVED ❑ APPROVED WITH U NOT APPROVED CORRECTIONS _.._......- Ok to proceed. Corrections will be Call for re- inspection before f� checked at next inspection procce ing. Date Spector �. _ __ -- Approved plans and permit card must be on -site and available at time of inspection. A re- inspec-•tion fee may be assessed if work is not ready fnr inspection. 9 0 o�p�prr °� CITY OF PORT TOWNSEND c; DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: O (7 PERMIT NUMBER: L_ SITE ADDRESS: PROJECT NAME: �kAlo e_ CONTRACTOR: J CONTACT PERSON: PHONE: TYPE OF INSPECTION: nS 1 I /� Pf11 mow_......,. � +�•1 9 i ❑ APPROVED } ❑ APPROVED WITH CORRECTIONS Ok to proceed. Corrections will be checked at next inspection f. �r Inspector —....- Date ❑ NOT APPROVED 1...17. Call for re- inspection before procccliing. Approved plans and permit card must he on -site and available at time of inspection. A re- inspection fee may be assessed if work is not ready,/or inspection. {QE PoRn. O 0 For DEVELOPMENT SERVICES OF PORT r0 inspections, call the ► WNSFND IDEPARTMEIV DATE the inspection ection Line at 360-385-229 C7'IO REP T S'T OE INSPECTION: `� For Monday inspections, by 3:op pM the day N ART E ADDRESS: { y 3:oo PM Frid before you meant T RMIT C NTAC FAME: aY CT PERSON: TYPE 0F'NSP CONTRACTOR: ECTZON: PRONE: PROVED APPROVED WITH CORRECT►O Ok R to NS Proceed. Correction [] NOT APPROVED Checked at next inspection s will be Call for re -ins 'tor I � � � pectin proceeding, n before 'd plans and �� Date k is rant reacYfur n -site aracl avcailcrhle 7e[tin. ct tune f ns F ee"Oa. A re_i"SPectiOrz fee ztaa Y L.] 9 �poRT CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT +� INSPECTION REPORT c►"w For inspections, call the Inspection Line at 360 - 385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: ) -1 () PERMIT NUMBER: ` SITE ADDRESS: 2 PROJECT NAME: CONTRACTOR: PHONE: CONTACT PERSON:, TYPE OF INSPECTION: 10 (Ilk, ❑ APPROVED ❑ APPROVED w1TH ❑ NOT APPROVED CORRECTIONS Ok to proceed. Corrections will be Call for re - inspection before checked at next inspection proceeding. Inspector 1 C L - -- Date r Approved plans and permit card must be on -site and available at time of inspection. A re- inspection fee may be assessed if work is not, ready for inspection. 'M • 1 0 of VoFkT r °� CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT ¢WA For inspections, call the Inspection Line at 360- 385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: LQ9 ()t12 PERMIT NUMBER: L `Q 040 1) ta- SITE ADDRESS: '' _c� hQ_at PROJECT NAME: bA I nb I P_ , CONTRACTOR: CONTACT PERSON: K 0_n PHONE: TYPE OF INSPECTION: ❑ APPROVED Inspector: F1 APPROVED WITH CORRECTIONS Ok to proceed. Corrections will be checked at next inspection Date Ll NOT APPROVED Call for re- inspection before proc ding. qIN- Approvedplans and permit card must be on -site and available at time of inspection. A re- inspection fee may be assessed if work is not ready for inspection. CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360- 385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION; � (.1 S!2 PERMIT NUMBER: � oI SITE ADDRESS: PROJECT NAME: ���T CONTRACTOR: [C C_L �f� CONTACT PERSON: n PHONE: _A �O_-- ,S 1111V�RI1].➢lI►6YZ�L�]1YI11� l f� \�.T � ❑ APPROVED ❑ APPROVED WITH ❑ NOT APPROVED =* „... _...... CORRECTIONS Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding. Inspector 1 Date Approved plans and permit card must he on -site and available at time of inspection. A re- inspection fee may he assessed ij'work is not ready for inspection. O� PORT TOE • CITY OF PORT TOWNSEND DEVELOPMENT SER vI PE D ON REPORT For inspections, call the Inspection Line at 360- 385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. 1� DATE OF INSPECTION: PERMIT NUMBER: ZZ SITE ADDRESS: CONTRACTOR: PROJECT NAME: PHONE: - CONTACT PERSON: TYPE OF INSPECTION: ❑ APPROVED n j Inspector h / ❑ APPROVED WITH ❑ NOT APPROVED CORRECTIONS Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding. �. Date Approved plans anti permit card must be on -site and available at time of inspection. A re- inspection fee may be assessed if work is not ready.for inspection.