Loading...
HomeMy WebLinkAboutBLD06-101o�VORT °� CITY OF PORT TOWNSEND u� DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT Ewa For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. f DATE OF INSPECTION: 7 - PERMIT NUMBER: �- -r 4 SITE ADDRESS:? — PROJECT NAME: \Z `'t� I� ` CONTRACTOR: c. CONTACT PERSON: t PHONE: TYPE OF INSPECTION: ALL, ❑ APPROVED ❑ APPROVED WITH ❑ NOT APPROVED .. CORRECTIONS == •= w = "'�� Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding. Inspector _ Date r' f Approved plans and permit card must be on -site: and available at time of inspection. A re- inspection fee muy be assessed ij'work is not ready for inspection. o� poRT v WA 0 CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360- 385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: PERMIT NUMBER: SITE ADDRESS: fiH PROJECT NAME: CONTACT PERSON: TYPE OF INSPECTION: CONTRACTOR: PHONE:�I _ ❑ APPROVED ❑ APPROVED WITH CORRECTIONS a U NOT APPROVED Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection pr�o^ceeding..7 Inspector Date f / Approved plans and permit card must he on -site and available at time of inspection. A re- inspection fee may be assessed if work is not ready for inspE:ction. 0 o� poRr CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: PERMIT NUMBER: SITE ADDRESS: =� PROJECT NAME: CONTRACTOR: CONTACT PERSON: PHONE: TYPE OF INSPECTION: 1^n w, t ...._• . PROVED (. V, p Inspector c' o7 (,_ /1) APPROVED WITH ❑ NOT APPROVED CORRECTIONS Ok to proceed. Corrections will be Call for re- inspection before ,,checked at next inspection proceeding. Date Approved plans and permit card must be on -site and availahle at time of insj)eciion- A re- insI)eclion fee mazy be assessed if work i.s not ready.for inspection. a..A. 0 o poRT row 0 =w PERMIT NUMBER: SITE ADDRESS: CONTRACTOR: DATE OF INSPECTION: r J L CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT WORKSITE OR CELL PHONE #: TYPE OF INSPECTION REQUESTED: 010 For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. ❑ APPROVED ❑ APPROVED WITH CORRECTIONS ❑ NOT APPROVED CALL FOR RE- INSPECTION NOTED BELOW ••..� BEFORE PROCEEDING VA... Approved plans and permit card must be on-site and available at time of inspection. A re- inspection fee may be sessed if work is not ready for inspection. Date Inspector �f � �' Date Acknowledged' G:__- LJ pOgT Tp CITY OF PORT TOWNSEND y "n DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT PERMIT NUMBER: SITE ADDRESS: F- "S,,5 5� '5r H CONTRACTOR: I DATE OF INSPECTION: WORKSITE OR CELL PHONE #: TYPE OF INSPECTION REQUESTED: f) h , t' For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. ❑ APPROVED ❑ APPROVED WITH CORRECTIONS 0 NOT APPROVED NOTED BELOW CALL. FOR RE- INSPECTION BEFORE PROCEEDING 4 �, .- 1 �. i,�1Cr c � A pp roved plans and permit card roust be on -sttc and available at time of inspection. A re- inspection fee may be, ssessed if work is not ready for inspection. C� Inspector Date Acknowledged :_, ., ; - °/ Date O�pOAT WA PERMIT NUMBER: CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT SITE ADDRESS: CONTRACTOR: DATE OF INSPECTION: WORKSITE OR CELL PHONE #: TYPE OF INSPECTION REQUESTED: A X.� For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. ❑ APPROVED,, ❑ APPROVED WITH CORRECTIONS 11 NOT APPROVED NOTED BELOW CALL FOR RE-INSPECTION BEFORE PROCEEDING 4 7-1 Approved plans and pen-nit card must be on-site and available at time of inspection. A re-inspection fee may be messed if work is not ready for inspection. Inspector-/-"-, C.. Date Acknowledged',/ Date Development Services Department 250 Madison Street, Suite 3 Port Townsend, WA 98368 Phone: (360) 379 -3208 Fax: (360) 344 -4619 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE For Next Day Inspection Call 385-2294 Before 3P.M. Permit Number: — BLD06 -1Q1 Issued: OS -21 -2006 Parcel Number: 972- 903 -605 Job Address: 855 55th St. Zoning: R -II Type: V -13 Occupancy: R -3 Nature of Work: Place double wide manufactured home on lot & construct attached breezeway and garage Owners: Kenneth Mikkelsen Contractor: Owner GENERAL CONDITIONS APPLY – SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical – Contact Labor & Industries @ 360- 417 -2702 NOTE: ACQUAINT YOURSELF WITH THE LISTED REQUIRMENTS TO RECEIVE FINAL BUILIDNG INSPECTION PRIOR TO THE START OF CONSTRUCTION AND PRIOR TO YOUR REQUEST FOR FINAL INSPECTION. * ** All elements of engineering including holdowns, framing, nailing and other engineering connections require inspection prior to cover. * * * RE UIRED INSPECTIONS APPROVED/DATE TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site MANUFACTURED HOME - FOOTINGS Setbacks – 1.0' from 55`h St. p /I, 5' from side p /l, 10' from rear p/1 Footings Forms Reinforcement Interior Pads GARAGE FOOTING Footing Rebar Holddowns Call 48 hours before you dig for utility line locates 1 -800- 424 -5555 Page 1 of 1 Permit #BLD06 -101 GARAGE - FOUNDATION WALLS Rebar Hold Downs Anchor Bolts & Washers Foundation drain Must be inspected prior to back -fill of foundation MANUFACTURED HOME Blocking Tie -downs Vapor Barrier GARAGE - Shear wall nailing ALTERNATE BRACED WALL PANEL (MUST BE INSPECTED PRIOR TO COVERING) GARAGE FRAMING — all members and connections require inspection prior to cover Fasteners hangers, etc. in contact with treated material must be hot dipped jzalvan ized Walls Headers Rafters (hurricane clips) Roof Sheathing Joists (hangers) Blocking Roof Venting — eave and ridge vents Safety Glazing Fire Blocking DRYWALL PUBLIC WORKS FINAL — SDP06 -038 Public Works Sign -Off (prior to building final) FINAL Parking — 2 space required House Numbers — 5" minimum Skirting Landings Final — Building Call 48 hours before you dig for utility line locates 1 -800- 424 -5555 Page 2 of 2 0 0091 pt= r r� Permit #BLD06 -101 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on -site and inspected prior to beginning construction; call 385 -2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights -of -way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re- inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385 -2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection_ 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379 -3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON -SITE WITH THE APPROVED PLANS. ,r _0 APPLICANT SIGNATURE DATE Call 48 hours before you dig for utility line locates 1- 800 - 424 -5555 Page 3 of 3