HomeMy WebLinkAboutBLD06-079p ° "rT °w T CITY OF PORT TOWNSEND
DEVELOPMENT SERVICES DEPARTMENT
e = F INSPECTION REPORT
For inspections, call the Inspection Line at 360 - 385-2294 by 3:00 PM the day before you want
the inspection. For Monday inspections, call by 3:00 PM Friday.
1 14 DATE OF INSPECTION: _ , PERMIT NUMBER: -t] dC6e ] L --b / 7
SITE ADDRESS: /ZO3�
PROJECT NAME: C-7C � e1 G K CONTRACTOR:
CONTACT PERSON: rY1 Igo-(e 11e___ E`er'_ PHONE: '7 �7
TYPE OF INSPECTION:
2 �Q �54
I �r
❑ APPROVED WITH NOT APPROVED
CORRECTIONS
Ok to proceed. Corrections will be Call for re- inspection before
checked at next inspection proceed' g.
Inspector Date r
Approved plans and permit card must e n -silo and available at time of inspection. A re- inspection fee may
be assessed if work is not ready for inspection.
Development Services Department
250 Madison Street, Suite 3
Port Townsend, WA 98368
Phone: (360) 379 -3208 Fax: (360) 344 -4619
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
For Next Day Inspection Call 385-2294 Before 3P.M.
Permit Number: BLD06 -079 Issued: 05/11/2006 Parcel Number: 936 -902 -405
Job Address: 720 53rd St. Zoning: R -I Type: V -B Occupancy: R -3
Nature of Work: Enclose exiting carport for bedroom & remove three interior walls for remodel
Owners: Frederick John
Contractor: Owner
GENERAL CONDITIONS APPLY — SEE LAST PAGE
SEPARATE PERMITS REQUIRED_
Electrical — Contact Labor & Industries @ 360- 417 -2702
NOTE: ACQUAINT YOURSELF WITH THE LISTED REQUIRMENTS TO
RECEIVE FINAL BUILIDNG INSPECTION PRIOR TO THE START OF
CONSTRUCTION AND PRIOR TO YOUR REQUEST FOR FINAL INSPECTION.
* ** All elements of engineering including holdowns, framing, nailing and other engineering connections
require inspection prior to cover. * * *
_REQUIRED 1.NV WEC'1'1QNS
FRAMING — all members and connections require inspection
prior to cover
Fasteners hap ers etc. in contact with treated material must be
hot dipped galvanized
Walls
Headers
Beams - 6 x 10 DF #1 or better
Positive Connections
NEED 14.4 sq. ft. of Natural Lighting in new bedroom
Windows - egress
Smoke detectors (bedrooms, outside bedrooms and each floor)
Windows U factor - .40 or better
NFRC window sticker must be on window, skylights & doors at
insp. time.
Air Seal
Fire Blocking
Weather Resistive Barrier
AY.VKU V ED /DA'I' -L
Call 48 hours before you dig for utility line locates
1- 800 - 424 -5555
Page I of 3
90
*0
Permit #BLD06 -079
INSULATION
Walls (R -21)
Vapor Barrier: paint for walls and ceiling
FINAL
Address Numbers -- 5" minimum
Heating
Smoke Detectors
Guardrails
Final — Building
Call 48 hours before you dig for utility line locates
1- 800 - 424 -5555
Page 2 of 3
Permit #BLD06 -079
00 GENERAL CONRLTLM
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on -site and inspected
prior to beginning construction; call 385 -2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights -of -way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re- inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385 -2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection..
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379 -3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON -SITE WITH THE APPROVED PLANS.
APPLICANT SIGNATURE DATE
Call 48 hours before you dig for utility line locates
1- 800 - 424 -5555
Page 3 of 3