HomeMy WebLinkAboutBLD06-0760 0 o�pogxr °� CITY OF PORT TOWNSEND n DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3 :00 PM Friday. / DATE OF INSPECTION: Z, Le P-ERMIT NUMBER: l-�_ �(9 — SITE ADDRESS: "T fJ Ee_7__ PROJECT NAME: CONTRACTOR: CONTACT PERSON: PHONE: TYPE OF INSPECTION: ❑ APPROVED / ❑ APPROVED WITH LJ NOT APPROVED CORRECTIONS Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding. Inspector ZLtz-', . L-6i/�__. Date Z 8. Approved plans and permit card must be on -site and available at time of inspection. A re- inspection fee may be assessed if work is not ready for inspection. Inspection Report Project * w Permit # D6 — 0 76 P pORTr °`� CITY OF PORT TOWNSEND c3 DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: PERMIT NUMBER: SITE ADDRESS: PROJECT NAME: CONTRACTOR: CONTACT PERSON: PHONE: TYPE OF INSPECTION: - -- N H - ......__...__ F1 APPROVED ❑ APPROVED WITH KNOT APPROVED CORRECTIONS Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding. Inspector _j _ Date r Approved plans and permit card must he on -site and available at time of inspection. A re- inspection fee may be assessed i f work is not ready, for inspection. poRTTp� CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT a INSPECTION REPORT q"wn For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: I PERMIT NUMBER: SITE ADDRESS: C 3 PROJECT NAME: W 1 CONTRACTOR: O CONTACT PERSON: PHONE: TYPE OF INSPECTION: to ❑ APPROVED X_ APPROVED WITH ❑ NOT APPROVED CO ECTIONS Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding. Inspector Date 6--1 -(2? Approved plans and permit card must he on -site and available at time of'inspection. A re- inspection, fee may be assessed if work is not ready for inspection. 0 • p�VoRTr °w CITY OF PORT TOWNSEND �p DEVELOPMENT SERVICES DEPARTMENT x INSPECTION REPORT TWA For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: 2. U PERMIT NUMBER: 13 t r) O p - o7 SITE ADDRESS: PROJECT NAME: ONTRACTOR: CONTACT PERSON: PHONE: TYPE OF INSPECTION: n APPROVED \ ❑ APPROVED WITH ❑ NOT APPROVED _ CORRECTIONS ��. Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding. t:= ! 4` Date Inspector - -- Approved plans and permit card must be on -site and available (it time of inspection. A re- inspection fee may be assessed if work is not ready,for inspection. 9 0 ,pow'rr CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT awn For inspections, call the inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. PERMIT NUM_ ER:^�` DATE OF INS PECTION: SITE ADDRESS: PROJECT NAME: CONTACT PERSON: TYPE OF INSPECTION: APPROVED CONTRACTOR: PHONE: C) uokj ❑ APPROVED WITH L] NOT APPROVED CORRECTIONS Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding Inspector u C Date Approved plans and permit card must he on -site and available at time of inspection. A re- inspection fee may be assessed if work is not ready fbr inspection. o� poar rod ¢wn CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: PERMIT NUMBER: I 00 SITE ADDRESS: PROJECT NAME: �A�� I I Gtf' _CONTRACTOR: J21� rrU CONTACT PERSON: ffia�,tPHON E: 36 TYPE OF INSPECTION: ��I1 J I Y Y o " U APPROVED r,,:, CJ APPROVED WITH U NO'I A 4-11. CORRECTIONS ft3k to proceed. Corrections will be Call for re -in ., c CORRECTIONS • - ,,:r��''� �' ' �, section before r l checked at next inspection procceding�° Inspector r. f + Date'+ a Approved plans and permit card must be on -site and available at time of inspection 14`t be assessed if work is not ready -for inspection. I . .I '�v. ,r may 0 0 9oaxro�r CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT ` INSPECTION REPORT For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: ` "T l i< PERMIT NUMBER: P� �— SITE ADDRESS: ;i j PROJECT NAME: t' `- ' " z CONTRACTOR: CONTACT PERSON: TYPE OF INSPECTION: PHONE: ❑ APPROVED ❑ APPROVED WITH CORRECTIONS i1 Ok to proceed. Corrections will be a checked at next inspection Inspector w Date zf ❑ NOT APPROVED Call for re- inspection before proceeding. Approved plans and permit card must he on -site and available at time of inspection. A re- inspection fee. may be assessed if work is not ready for insl)ection. o� VORT rod CITY OF PORT TOWNSEND c DEVELOPMENT SERVICES DEPARTMENT s INSPECTION REPORT �wa For inspections, call the Inspection Line at 360 -3$5 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: 2 C,)7 PERMIT NUMBER: 15 SITE ADDRESS: ' PROJECT NAME: !; LIt) _f_P `D 1+\4 P_-FIP� CONTRACTOR: CONTACT PERSON: TYPE OF INSPECTION: PHONE: `- t 1,9 t, AFR_ - ❑ APPROVED �Ad ❑ APPROVED WITH ❑ NOT APPROVED N µ CORRECTIONS Ok to proceed. Corrections will be Call for re- inspection before checked at next inspection proceeding. Inspector r Date ._ 1 Approved plans and permit card must be on -site and available at time of inspection. A re- inspection fee may be assessed if work is not reac�v for inspection. !. Development Services Department 250 Madison Street, Suite 3 Port Townsend, WA 98368 Phone: (360) 379-3208 Fax: (360) 344-4619 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE For Next Dav Inspection Call 385 -2294 Before 3P.M. Permit Number: BLD06 -076 Issued: 10/10/2006 Parcel Number: 972- 903 -006 Job Address: 1361 54th St.. Zoning: R -I Type: V -B Occupancy: R -3 Nature of Work: Construct single- family residence over garage & home occupation offices Owners: Matthew Wallace & Loni Neff Contractor: Owner GENERAL CONDITIONS APPLY — SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical — Contact Labor & Industries @ 360 -417 -2702 NOTE: ACQUAINT YOURSELF WITH THE LISTED REQUIRMENTS TO RECEIVE FINAL BUILIDNG INSPECTION PRIOR TO THE START OF CONSTRUCTION AND PRIOR TO YOUR REQUEST FOR FINAL INSPECTION. * ** All elements of engineering including holdowns, framing, nailing and other engineering connections require inspection prior to cover. * * * T)Y,+l1TTT"Irl " 1rXTQ1D- f "'TTf1XTQ A PPI20VF,D1n ATF TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks — 20' from p/I on 54th St. -- 5' from East p /1 -10' from Hendricks St. p/I — 10' from south p/I Footings Forms Reinforcement Interior Pads UFER Ground (tied to footing rebar steel) FOUNDATION WALLS Reinforcement Hold Downs — MUST BE TIED IN PLACE — NO WET Call 48 hours before you dig for utility line locates 1- 800.424 -5555 Page I of 4 r Permit #BLD06 -076 STICKING Anchor Bolts & Washers PLUMBING: Rough -In (D -V -T & Clean outs) Water Supply Water Hammer Arrester (on dishwasher, ice maker & clothes washer) Hose Bibs (backflow protection required) Pipe Insulation (R -3) Pressure Reduction Valve required Water Heater Seismic Restraint — strap tank @ 1/3 points Pressure relief valve drain to exterior, terminate 6" — 24" above ground Listed expansion tank Licensed Plumbing Contractor's Signature & License Number: Sign here FLOOR FRAMING CALL FOR INSPECTION BEFORE COVER Joists Girders Posts Hangers Blocking Positive Connections Treated Wood to Concrete Pressure treated plate connections Anchor Bolts & Washers Hold downs Shear wall nailing & hold downs EXTERIOR & INTERIOR BRACED WALL PANELS (MUST BE INSPECTED PRIOR TO COVERING) 0 Story to be sheathed with wood structural panel — both interior & exterior braced wall panels. 2 °d story can be sheathed with gypsum wallboard MECHANICAL Whole House Fan Kitchen/Bath/Laundry Fans Environmental Air Exhaust ducting (w/ back draft dampers), Insulation (R -4) (on ducting in unheated space) LPG Heating Stove LPG Tank Gas Piping Call 48 hours before you dig for utility line locates 1- 800 - 424 -5555 Page 2 of 4 E 0 Permit #BLD06 -076 FRAMING — all members and connections require inspection prior to cover Fasteners hangers, etc. in contact with treated material must be hot di pyed galvanized Walls Headers Rafters (hurricane clips) Roof Sheathing Joists (hangers) Blocking Roof Venting — eave and ridge vents Windows - egress Smoke detectors (bedrooms, outside bedrooms and each floor) Safety Glazing Windows U factor - .40 or better Doors U- factor - .20 or better NFRC window sticker must be on window, skylights & doors at insp. time. Air Seal Fire Blocking Weather Resistive Barrier INSULATION Floor (R -10) Walls (R -LI) Ceiling - attic (R -30 vault) Attic (R -38) Vapor Barrier: paint for walls and ceiling Baffles DRYWALL PUBLIC WORKS FINAL (SDP06- 034) Public Works Sign -Off (prior to building final) FINAL Parking — 2 space required House Numbers — 5" minimum Plumbing Mechanical /Heating Vapor Barrier Paint Certificate Insulation Certificate Smoke Detectors Final — Building 1. Contractors working on this project are required to have a Labor & Industries contractor's re ,aistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. Call 48 hours before you dig for utility line locates 1- 800 - 424 -5555 Page 3 of 4 Permit #BLD06 -076 2. Temporary erosion and sediment control (TESC) measures shall be installed on -site and inspected prior to beginning construction; call 385 -2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights -of -way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re- inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385 -2294. A minimum of twenty -four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non- residential project. 8. All building permit expire if work is not begun within 180 days of issuance, or if the work authorized by the permit is suspended or abandoned for a period of 180 days after the work is begun. The building official may grant a one -time 180 day extension if a request in writing, and the lack of progress occurred for a justifiable cause. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379 -3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON -SITE WITH THE APPROVED PLANS. lwr "y. 64& �o /i�lZ.00(v APPLICANT SIGNATURE DATE Call 48 hours before you dig for utility line locates 1- 800 - 424 -5555 Page 4 of 4