Loading...
HomeMy WebLinkAboutBLD06-072• 0 PORT r0 CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT PERMIT NUMBER: O(Z2 Q �� SITE ADDRESS: CONTRACTOR: DATE OF INSPECTION: WORKSITE OR CELL PHONE (D433__ TYPE OF INSPECTION REQUESTED: For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. APPROVED ❑ APPROVED WITH CORRECTIONS Cl NOT APPROVED NOTED BELOW CALL FOR RE- INSPECTION BEFORE PROCEEDING Approved pla a d permit card st be on -site and available at time of inspection. A re- inspection fee may be a es cif work is U�7;dy or inspection. r Inspector Date N Date . Ll Acknowledge , i .��_� • )q ry) poRr ro �qF CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT PERMIT NUMBER: 13 (J) C7 Cp `-` Q "7 Z_ SITE ADDRESS: CONTRACTOR: t� / DATE OF INSPECTION: WORKSITE OR CELL PHONE #:( Al TYPE OF INSPECTION REQUESTED: �� 1 L 4 1L1 � V__ For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. ❑ APPROVE 0 APPROVED WITH CORRECTIONS NOTED BELOW 0 NOT APPROVED CALL FOR RE- INSPECTION BEFORE PROCEEDING T 7- Approved plans and permit card must be on -site and avai a e f inspection. A re- inspection fee may b ssess�edd�if work is not ready for inspection. Inspector Jt r J V t/ - Date Acknowledged kh ci;fL. (r/�.! .�% Date • poor ra Fyn CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT PERMIT NUMBER: LD C20 SITE ADDRESS: rn CONTRACTOR: DATE OF INSPECTION: `7 WORKSITE OR CELL PHONE #: �JCo -� 1 TYPE OF INSPECTION REQUESTED: For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. ❑ APPROVED 0 APPROVED WITH CORRECTIONS ❑ NOT APPROVED \ NOTED BELOW CALL FOR RE- INSPEC'T'ION BEFORE PROCEEDING. EE Approved plans and permit card must be on -site and available at time of inspection. A re- inspection fee may be sessed ifwork is not ready for inspection. / 2ZI Inspector C �� L. 1 ! ��. - Date _ ;f Acknowledged \' ,,' `Zl f _T �A i : �� Date • A OAT r °,sue CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT PERMIT NUMBER: 5 L. D OL - 61a SITE ADDRESS: 02 lily CONTRACTOR: DATE OF INSPECTION: WORKSITE OR CELL PHONE #: Lc�e__[Q ��Dq J 1 TYPE OF INSPECTION REQUESTED: For inspections, call the Inspection Line at 360 -385 -2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. APPROVED ❑ APPROVED WITH CORRECTIONS ❑ NOT APPROVED NOTED BELOW CALL FOR RE- INSPECTION BEFORE PROCEEDING 1 ZI Approved pla and permit card must be on-site and available at time of inspection. A re- inspection fee may be s ssed if work of ready for inspection. Inspector L '% Date Acknowledg Date !7 _ 0 Development Services Department 250 Madison Street, Suite 3 Port Townsend, WA 98368 Phone: (360) 379 -3208 Fax: (360) 344 -4619 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE For Next Day Inspection Call 385-2294 Before 3P.M. Permit Number: BLD06-072 Issued: 5/19/2006 Parcel Number: 957 - 607 -006 Job Address: 2219 E. Sims Way Zoning: C -II Type: V -B Occupancy: B Nature of Work: Tenant Improvement for Country Wide Loans Occupant Load: 13 Owners: No Wine Left LLC Contractor: Drury Construction — DRURYC *233L0 GENERAL CONDITIONS APPLY — SEE LAST PAGE SEPARATE PERMITS RE UIRED; Plumbing Mechanical Lighting Exterior Signage Electrical — Contact Labor & Industries @ 360 -117 -2702 NOTE: DEFERRED SUBMITTALS INCLUDE PLUMBING, MECHANICAL, LIGHTING PLANS. NOTE: ACQUAINT YOURSELF WITH THE LISTED REQUIRMENTS TO RECEIVE FINAL BUILIDNG INSPECTION PRIOR TO THE START OF CONSTRUCTION AND PRIOR TO YOUR REQUEST FOR FINAL INSPECTION. * ** All elements of engineering including holdowns, framing, nailing and other engineering connections require inspection prior to cover. * * * 121Wn'FT1121F]1 T1V1QPF.("Tl1nNC APPROVVD /PATE PLUMBING DEFERRED SUBMITTAL MECHANICAL DEFERRED SUBMITTAL LIGHTING DEFERRED SUBMITAL FRAMING — all members and connections require inspection prior to cover Demising Wall = 6" metal studs (20 gage) @ 16" oc attached to existing slab w/ 2 - #S power driven ins. Studs attached at top to Call 48 hours before you dig for utility line locates 1 -800- 424 -5555 Page 1 of 3 0 0 Permit #BLD06 -072 4" 20 gage x 8" studs w/ 3 #8 screws to track & 3 #8 screws to 6" bracing studs. Diagonal 6" 20 gage studs one pair to existing every 2nd TH w/ 8 — 8 gage screws Partition Walls = 3 5/8" metal studs (20 gage) @ 16" oc Plumbing Walls = 5 '' /z" metal studs (20 gage) @ 16" oc Windows Doors Safety Glazing Air Seal Fire Blocking SUSPENDED ACOUSTICAL CEILING BRACING — TO BE INSPECTED PRIOR ACOUSTICAL TILE INSTALLATION Cross bracing @ 12' oc both ways w/ No. 12 gauge wires. Horizontal restraint point placed no more than 12' oc in both directions w/ 15t point w /in 6' from each wall. Non - combustible struts\ 12 gauge vertical hanger wires @ 4' oc Lateral force bracing 4 each 12 gauge wire secured to main runner w /in 2" of cross tee intersection @ splayed 90" from each other @ 12' oc both directions w/ I" point w /in 4' from each wall. INSULATION Restroom Walls - Acoustical Insulation Ceiling — Acoustical Insulation Demising Wall — Sound Batt Insulation DRYWALL Demising Wall = 5/8 Type X GWB each side to underside of roof structure. Penetrations to be fire taped & sealed. Partition Walls = 5/8" GWB each side to 6" above highest adjacent ceiling w/ acoustical insulation in restrooms. Water resistant GWB in restrooms. FIRE DEPARTMENT FINAL BUILDING FINAL Electrical Final Plumbing Mechanical Lighting Address Numbers — 5" minimum Grab Bars Exit Signs Interior Signage Call 48 hours before you dig for utility line locates 1- 800 - 424 -5555 Page 2 of 3 0 0 Permit #BLD06 -072 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on -site and inspected prior to beginning construction; call 385 -2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights -of -way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re- inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385 -2294. A minimum of twenty -four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379 -3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON -SITE WITH THE APPROVED PLANS. _31e, C APPLI NT SIGNATURE DATE Call 48 hours before you dig for utility line locates 1 -800- 424 -5555 Page 3 of 3