HomeMy WebLinkAboutBLD06-009A
Development Services Department
250 Madison Street, Suite 3
Port Townsend, WA 98368
Phone: (360) 379 -3208 Fax: (360) 344 -4619
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
For Next Day Inspection Call 385 -2294 Before 3P.M.
Permit Number: BLD06 -009 Issued: 11/13/2006 Parcel Number: 948 324 901 & 902
Job Address: 651 Cleveland Street Zoning: C -II Type: V -B Occupancy: RR =1
Nature of Work: Convert garage to two bungalows
Owners: Freeland Investments Inc. dba Manresa castle Contractor: Owner
i
GENERAL CONDITIONS APPLY —SEE LAST PAGE o ka7t) C[ / ��
SEPARATE PERMITS REQUIRED: L
Electrical — Contact Labor & Industries @ 360 -417 -2702
NOTE: ACQUAINT YOURSELF WITH THE LISTED REQUIRMENTS TO
RECEIVE FINAL BUILIDNG INSPECTION PRIOR TO THE START OF
CONSTRUCTION AND PRIOR TO YOUR REQUEST FOR FINAL INSPECTION.
* ** All elements of engineering including holdolvns, framing, nailing and other engineering connections
require inspection prior to cover. * **
RF 111IRFI) INfiPFCTI0NS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving the site
PLUMBING:
Rough -In (D -V -T & Clean outs)
Water Supply
Water Hammer Arrester (on dishwasher, ice maker & clothes
washer)
Hose Bibs (backflow protection required)
Pipe Insulation (R -3)
Pressure Reduction Valve required
Water Heater
Seismic Restraint — strap tank @ 1/3 points
Pressure relief valve drain to exterior, terminate
6" — 24" above ground
Expansion tank
Call 48 hours before you dig for utility line locates
1- 800 - 424 -5555
Page 1 of 3
Permit #BLD06 -009
MECHANICAL
Whole House Fan W/ 24 hour timer
Kitchen/Bath/Laundry Fans
Environmental Air Exhaust ducting (w/ back draft dampers),
Insulation (R -4) (on ducting in unheated space)
FRAMING — all members and connections require inspection
prior to cover
Fasteners hangers etc in contact with treated material must be
hot dipped galvanized
Rafters (hurricane clips)
Roof Venting — eave and ridge vents
Smoke detectors (bedrooms, outside bedrooms and each floor)
Safety Glazing
Windows U factor - .40 or better
Doors U- factor - .20 or better
NFRC window sticker must be on window, skylights & doors at
insp. time.
Air Seal
INSULATION
Walls (R-2 1)
Vault (R -30)
Attic (R-30)
Vapor Barrier: paint for walls and ceiling
Baffles
DRYWALL
FIRE DEPARTMENT
Fire sprinklers
PUBLIC WORKS FINAL
Public Works Sign-Off (prior to building final
FINAL
Mechanical/Heating
LPG
Vapor Barrier Paint Certificate
Smoke Detectors
Final — Building
Call 48 hours before you dig for utility line locates
1 -800- 424 -5555
Page 2 of 3
Permit #BLD06 -009
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may result in
job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on -site and inspected prior to
beginning construction; call 385 -2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights -of -way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is
responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP)
require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re- inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works requirements
have been completed and inspected. For Public Works inspection call 385 -2294. A minimum of twenty -four
hours notice is required Public Works approval must be received prior to scheduling the Building
Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non - residential
project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done by the
Building Department within one year. Call for at least one inspection per year to keep your building permit
active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379 -3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON -SITE WITH THE APPROVED PLANS.
APPLICANT SIGNATURE DATE
Call 48 hours before you dig for utility line locates
1- 800 - 424 -5555
Page 3 of 3