Loading...
HomeMy WebLinkAbout12-025 Adopting a Resource Management Plan and PolicyResolution 12 -025 Page I of 2 RESOLUTION NO. 12 -025 RESOLUTION OF THE CITY COUNCIL OF THE CITY OF PORT TOWNSEND, WASHINGTON ADOPTING A RESOURCE MANAGEMENT PLAN AND ESTABLISHING A RESOURCE MANAGEMENT POLICY FOR DAILY OPERATIONS WHEREAS, The City of Port Townsend recognizes it has a leadership role in the responsible use of natural resources; and 2. Consumption of natural resources has come under increasing concern for all individuals, businesses, private groups and public entities, due to factors such as: A. Costs — wasteful and inefficient consumption reduces funding for other activities and programs important to the mission of The City of Port Townsend, and B. Sustainability, such as 1) Climate Change - consuming resources, especially fossil fuels for energy production, has been shown to increase levels of green house gasses and contribute to climate change, and 2) Environmental Stewardship — irresponsible consumption of resources can cause environmental degradation, harm to our quality of life and a burden to future generations; and The City of Port Townsend desires to be responsible, efficient and financially prudent in its use of resources necessary for daily operations; and 4. The City of Port Townsend, along with four other local jurisdictions, signed an Interlocal Agreement for Resource Conservation Management Services on June 14, 2010, to participate in and fund a Resource Conservation Management Program; and 5. The City of Port Townsend desires to establish a Resource Management Policy to direct responsible, efficient and financially prudent use of resources necessary for daily operations. 6. The Resource Conservation Manager has collaborated with City Department Heads to craft a Resource Management Plan for the City which includes: A. A summary of energy use, costs and recommended targeted savings B. A recommendation of, and incentives for staff from key departments who will participate in the Plan's implementation C. A recommendation of how and by whom resource accounting will be used to track and monitor energy usage costs Resolution 12 -025 Page 2 of 2 D. A recommendation of steps to take and incentives to involve employees throughout the organization to actively participate in energy and resource conservation E. A recommendation of no- to low -cost resource use guidelines that address: 1) Heating and cooling set points 2) Lighting guidelines 3) Guidelines for use of electrical appliances and equipment 4) Domestic hot water set points and operating schedules 5) Domestic water and irrigation standards 6) Solid waste and recycling NOW THEREFORE BE IT RESOLVED, that 1. The City of Port Townsend is committed to leadership in the responsible use of natural resources; and 2. The Resource Management Plan dated April 16, 2012 (Exhibit A) is hereby adopted and staff is hereby directed to work with the Jefferson County Resource Conservation Manager to implement the plan as resources allow; and 3. The City of Port Townsend hereby establishes a Resource Management Policy (Appendix A of Plan) for Daily Operations that directs responsible, efficient and financially prudent use of resources by all employees. ADOPTED by the City Council of the City of Port Townsend at a regular meeting thereof, held this 18th day of June 2012. Attest: Pamela Kolacy, MMC� t City Clerk l David King, Mayor Approved as to form: John P. Watts City Attorney Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 1 of 14 4 f IN ' :I iai it ii -- Resource Management Plan City of Port Townsend April 16, 2012 Executive Summary In 2010, the City of Port Townsend signed an interlocal agreement with four other local jurisdictions to fund a Shared Resource Conservation Manager (RCM) in Jefferson County. The RCM is tasked with making recommendations on reducing cost and resource use in the City facilities. This Resource Management Plan provides guidelines to assist the RCM, Facilities Managers and City Staff in reducing energy, water and solid waste related operating costs through optimization of building systems and occupant behavioral changes. The goal of the program is to reduce resource use by 10% over three years. If we are able to meet this goal, we will save over$34,000 in annual utility costs and cost avoidance, based on the 2010 baseline numbers. And these savings continue in subsequent years. Implementation of this Plan will also help the City of Port Townsend meet the substantial greenhouse gas reduction goals outlined in the City of Port Townsend &Jefferson County 2011 Climate Action Plan. Facility Overview The City of Port Townsend (referred to as "City") facilities include staff offices, maintenance shops, City parks, public rental spaces, a swimming pool, compost facility and wastewater treatment plant. Utilities are provided by Puget Sound Energy (electricity), the City of Port Townsend (water) and private companies (garbage, propane and heating oil). A list of the facilities included in the RCM program is shown in Appendix B. Most of the buildings use electric resistance or heat pumps for heating, with the exception of City Hall (propane), Mountain View and the Equipment Shop (heating oil). Mechanical air conditioning is found in City Hall; all others rely on natural ventilation for cooling. Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 2 of 14 Resource Use Summary The following figures summarize the current resource use in the City. For more details on overall and site resource usage, refer to the RCM Year 1 Summary report. With electricity accounting for 52% of the City's utility bills in 2011, the greatest opportunities for savings are in the electrical area. This includes space heating and cooling, lighting, pumping, hot water production and plug loads. Mountain View uses a large amount of energy (in the form of electricity and heating oil) to heat the building and swimming pool, so proper operation of this building will yield significant payback. Electric demand charges are based on the maximum electrical draw during the month. A single electrical spike can cost the City hundreds of dollars. That is why it is important to stage electrical equipment (especially electric heaters during the morning warm-up period) to prevent these costly spikes. Water use was greatly reduced in 2011, due to irrigation reductions and construction project completion. Solid waste pickup costs are only 5.3% of total utility costs, which is very good when compared to other county government agencies. City of Port Townsend 2011 Utility Cost $19,446,5% 37,392 $16,875,5% 10% ■ Electric ■ Heating ail Propane $192,306,5, $102,938,28% ■Water Refuse Figure 1: In 2011, electricity use, which includes space heating, lighting, pumping, hot water production, and plug loads, accounted for 52%of the$369,000 City utility expenditures. Over Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 3 of 14 half of the electricity was used at the Waste Water Treatment plant. Mountain View accounts for most of the Heating OR cost, and there are potential savings in proper operation of this facility. Energy Use Graph - City of Port Townsend 1,500 1,000 500 0 01/09 04/09 07/09 10/09 01/10 04/10 07/10 10/10 01/1 1 04/11 07/11 10/11 01/2009 thru 10/2011 1 Electricity 1 Fossil Fuels *Annual Trend .........,r.—,.1,za .1 4.am Figure 2:Aggregate energy consumed by City facilities since January, 2009. This includes electricity, propane and heating oil. Energy Cost Graph - City of Port Townsend 40,000 30,000 20,000— t 10,000- 0 01/09 04/09 07/09 10/09 01/10 04/10 07/10 10/10 01/1 1 04/11 07/11 10/11 01/2009 thru 10/2011 1 Electricity 1 Demand 1 Fossil Fuels ♦Annual Trend Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 4 of 14 Figure 3:Aggregate monthly energy costs for City facilities since January, 2009. The rising cost of heating oil and propane is pushing energy costs higher, despite optimizing heating schedules. Water Use for City of Port Townsend 600,000 500,000 400,000 D t? 300,000 ■ Nov 09 to Oct 10 200,000 ■ Nov 10 to Oct 11 100,000 0 Nora Dec Jan Feb Mar Agar May Jun Jul Aug Sept Oct Month in period Figure 4: Water use in the City is split evenly between irrigation and potable (sinks, toilets, swimming pool). Reduced irrigation at Pope Marine and Mountain View, coupled with completion of downtown construction projects, has resulted in a large decrease in water use in 2011. Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 5 of 14 Solid Waste Removal Cost for City of PT $3,000 -- ti'� v $2,500 0 U 3 $2,000 0 E $1,500 a ■Nov 09 to Oct 10 a $1'000 ■Nov 10 to Oct 11 ?� $500 0 $0 Nov Dec Jan Feb Mar Apr May Jun Jul Aug Sept Oct Month in period Figure 5:Solid waste removal cost is 5.3%of the total utilities, and has remained constant over the past couple of years. Note the rate increase in August of 2011. The bump in September 2010 was likely due to construction hauling costs. Utility Accounting The City of Port Townsend is a member of the Shared RCM program, which uses a third party software package, Utility Manager, for resource accounting purposes. It is the responsibility of the RCM to enter all monthly utility billing information into the database, including usage, itemized costs, and updated facility and account information. This database has been populated for historical data dating back to 2009, and will be maintained by the RCM throughout the contract period. The RCM will also rank facilities by the Energy Use Index (EUI, defined as kBTU/ft2/year) in order to determine which facilities use the most energy per area. Energy consumption trending will be analyzed by the RCM, and findings will be shared with City staff. This data will be used to evaluate which facilities need more significant improvement than others, and to measure the effectiveness of resource conservation programs. In addition to Utility Manager, Puget Sound Energy (PSE) provides an online tool that captures electric meter readings at 15 minute intervals. This service, the Energy Interval Service, allows for the determination of the peak electric demand at a site, and is instrumental in reducing monthly demand charges. Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 6 of 14 City Resource Management Leadership Team Putting City resource management programs into motion requires support from leadership. The following City leaders agree to the principles outlined in the City Resource Conservation Management Policy and agree to be stewards of the RCM program. City Manager— David Timmons Public Services Director— Rick Sepler Public Works Director— Ken Clow Capital Projects Director— David Peterson Finance Director— Michael Legarsky Police Chief— Conner Daily Operations Manager—John Merchant Staff Participation There are several key components to engaging City staff in the RCM program. An outline follows: 1. Facility Charettes Transforming recommendations into action is a key to the success of any RCM program. City staff, in partnership with the RCM, will host a number of facility charettes, where interested staff will discuss recommendations for optimizing building performance and conserving resources. The outcome of these meetings will be prioritized lists for behavioral or capital investment projects that will result in resource savings and attractive return on investment. 2. Network-Based Bulletin Boards Communicating via electronic media allows efficient sharing of information to a wide audience. The following online sites are recommended for distributing the resource conservation message to the community, staff and visitors. • Quarterly Green newsletters • City web site • RCM web site 3. Media/Community Outreach The community funds the City government and wants to know that their tax dollars are being spent effectively and responsibly. Resource conservation practices that save money and reduce environmental impact present a positive outreach message to the community. Common outreach mechanisms include: • Community newsletters • Programming on local radio stations • Articles in local newspapers Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 7 of 14 4. Key Staff Communication Administrative Staff— Resource management best-practices should be clearly communicated to administrative staff in all departments. It is recommended that resource conservation becomes a standing agenda item in all staff meetings. Facilities/Maintenance Staff—Verification of enacted best-management procedures will often be the responsibility of facilities or maintenance staff. The RCM must clearly communicate objectives and obtain continual feedback from these departments. Resource Management Policy The RCM, in collaboration with other City staff, has developed a Resource Management Policy(Appendix A). The Policy will be presented to the City Council on June 18, 2012. Following is a list of staff involved in the development and implementation of the Policy: City Manager— David Timmons Public Services Director— Rick Sepler Public Works Director— Ken Clow Operations Manager—John Merchant IT Manager— Mark Peil Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 8 of 14 Appendix A City of Port Townsend Resource Management Policy Purpose and Intent The purpose of this policy is to establish protocols for the conservation of resources in the work place. The policy recognizes that each employee can take actions to avoid unnecessary utility costs and to contribute to energy efficiency in the City of Port Townsend ("City"). The implementation of the following measures will result in an immediate and significant operational cost savings and will help the City meet the substantial greenhouse gas reduction goals outlined in the City of Port Townsend &Jefferson County 2011 Climate Action Plan. Scope This policy applies to all City facilities and management procedures. The policy actions are divided into two sections: 1. City Facilities & Management 2. City Staff Policy Actions - City Facilities & Management A. FACILITY LIGHTING 1. Replace all incandescent lighting over time with energy efficient alternatives, while maintaining historical standards. 2. In overlit areas, remove lamps in existing light fixtures, while maintaining reasonable lighting levels. The following recommended lighting levels were extrapolated from the Washington State Energy code standards. Space Description Recommended Lighting Level (footcandles) Private office, reading area 40 Kitchen prep area 30 Library 30 Meeting room 30 Gymnasium 30 Maintenance shop 20 Hallway, lobby 20 Restroom 10 Store room, stairway 10 Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 9 of 14 Egress I >1 3. Minimize decorative lighting in all facilities. Decorative lighting includes upward-facing fixtures that don't provide light to the working area. 4. Convert all incandescent interior "Exit" signs to LED to save energy and reduce maintenance. 5. Develop a City-wide fluorescent bulb recycling protocol and educate custodial staff on procedures for safe bulb disposal. 6. Where applicable, install occupancy sensors and ambient light sensors in buildings. Utilize occupancy sensors in public areas such as meeting rooms, break rooms and bathrooms, where occupancy averages less than 75%. Install light sensors in hallways and rooms with ample exposure to daylight. 7. Install high efficiency, low ballast factor fluorescent ballasts in new construction and renovation. Utilize programmed start ballasts anywhere lighting control systems could be considered. 8. Night custodians should only turn on lights in the immediate area in which they are working. 9. All exterior lights will be turned off during daylight hours, utilizing photo sensors where applicable. Exterior building and parking lot lights should be scheduled off between 11:00 pm and 6:00 am (or 15 minutes after facility is secured and 15 minutes prior to first staff arrival). Safety lighting will be operated at required minimum to protect from vandalism. B. ELECTRICAL APPLIANCES AND EQUIPMENT 1. Energy Star rated appliances should be used in all facilities. Energy Star is a well-known joint program between the US EPA and DOE that certifies products that use less energy than average. 2. Common copiers will be set to energy saving mode. 3. Turn off vending display lights and install Vending-Miser sensors on all vending machines. C. HEATING, VENTILATION,AND AIR CONDITIONING 1. In order to balance occupant comfort and energy savings, the following heating and cooling set points (degF) will be used as a starting point. These setpoints are based on averages for buildings in the PNW, as recommended by the WSU Energy Extension Service. Since Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 10 of 14 facilities differ in design and space conditioning equipment, exceptions to this policy are at the discretion of the facilities staff. Area Occupied Set Points * Unoccupied Set Points Heating Cooling [1] Heating Cooling [1] Office 68 76 55 85 Meeting Room 68 76 55 85 Staff Lounge & Lunchroom 68 76 55 85 Equipment Shop 65 76 55 85 Locker Room 68 76 55 85 Work & Copy Room 67 76 55 85 Restroom 65 76 55 85 Hallway & Common Area 65 76 55 85 Computer Server Room 55 75 55 75 Storage Room 62 78 55 85 [1] where mechanical cooling is available *Slight variations may be allowed per the following: • Optimum start/morning warm-up control • In areas where a single sensor or thermostat serves multiple spaces, to provide a reasonable level of comfort throughout all areas served. • In areas with temperature-sensitive materials (solvents, artifacts, art work) 2. Outside air should be minimized during heating months to reduce energy use, while maintaining healthy air quality. CO2 levels in all occupied areas should be maintained in the 800-1000 ppm range to balance fresh air with energy savings. 3. During cold weather events, building maintenance will be responsible for ensuring that freeze-protection set points are reasonable and are returned to standard set points once the danger of sustained freezing temperatures has passed. 4. Building managers shall make efforts to group after-hour activities into a specific HVAC zone such that minimal system energy is required. 5. If specific areas are occupied by regularly assigned staff during unoccupied periods, zone heating and cooling shall be used rather than conditioning the entire building. HVAC settings for zoned areas shall be per normal operation. 6. All systems shall remain in UNOCCUPIED mode during non-scheduled work hours. 7. Thermostat programs and battery backups should be checked a minimum of two times yearly. It is recommended that this be scheduled during daylight savings time change. Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 11 of 14 8. Exhaust fans shall be turned off during UNOCCUPIED periods. 9. Air conditioning shall not be used in unoccupied rooms during the summer months. Some variations may be allowed based on specific HVAC system and specific facility needs (such as computer server rooms). D. WATER MANAGEMENT 1. Building plumbing and irrigation equipment leaks are to be reported and repaired as soon as possible. A small leak can result in significant waste (and cost) if left unattended. 2. Landscaping will use drought-tolerant design and native plants whenever possible. These areas will not be irrigated once established. 3. Irrigation months shall be limited to May through September, with exceptions for severe drought years and establishing new vegetation. 4. Irrigation timers will be programmed for the most efficient watering schedule for a specified landscape and soil type. Irrigation control systems will only be operated by City staff and City-hired contractors. 5. All outdoor watering will be scheduled to minimize evaporation, prevent disease, and protect irrigation equipment. 6. Thermostats for water heaters servicing washrooms will be set not to exceed 115°F. 7. Only low-flow toilets and urinals (using 1.2 gallons of water per flush or less) may be used in new construction or renovation projects. 8. Implement water-conserving retro-fit kits and/or other modifications on existing high- volume toilets, sinks, urinals, and shower facilities. E. SOLID WASTE MANAGEMENT 1. Reducing waste is the overall goal. Reusing and recycling materials are better than sending material to the landfill, but are inferior methods to reducing waste. 2. The Resource Conservation Manager and interested staff members will partner in the development of a comprehensive material reduction and recycling program for all facilities, and will support staff training regarding appropriate and efficient waste sorting and handling methods. 3. The custodial staff will monitor the quantity in the garbage and recycling dumpsters. Dumpster size and frequency of pick-ups will be adjusted according to need and cost economy. Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 12 of 14 4. Environmentally preferable products will be purchased by the City purchasing agents and include the highest practicable recycled content and recyclability in order to reduce the amount of solid waste produced by City facilities. 5. All waste, recycling, and food-waste containers will be located near one another and clearly labeled to simplify waste handling and sorting. F. COMMUNITY LEADERSHIP 1. The City shall consider renewable energy technologies in all new construction and renovation projects whenever technically and economically feasible. 2. The City leadership shall work with the RCM to acknowledge sustainable behavior through annual awards that recognize environmental stewardship among staff. Policy Actions - City Staff A. FACILITY LIGHTING 1. Natural light should be utilized whenever possible. Leave artificial lights off or use multi- level lighting when natural light is adequate. 2. Use compact fluorescent (CFL) or LED task lighting at desks. Consult with your building manager for recommendations, and to see if they have replacement lamps in stock. 3. Turn off lights in offices, shops and meeting rooms when the room will be unoccupied for 5 minutes or longer. 4. For activities, events, and facility use beyond normal business hours, utilize necessary lighting in occupied areas only. B. ELECTRICAL APPLIANCES AND EQUIPMENT 1. Because personal space heaters can interfere with building heating systems and can be a fire hazard, they should be used as a last resort. Work with your building manager to explore other options for heating your work area. In work areas that require additional heat, radiant panel heaters are more efficient than traditional space heaters and have far less impact on the surrounding occupants. 2. Personal appliances (coffee pots, microwave ovens, toasters, or refrigerators) are prohibited where common area appliances are available. Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 13 of 14 3. Staff should turn off computers, monitors, and peripherals at the end of each work day. If possible, equipment must be turned completely off and not left in standby mode. Peripherals include, but are not limited to: printers, copiers, scanners, desk lights and display lights. C. HEATING, VENTILATION,AND AIR CONDITIONING 1. Groups who use the facilities after-hours shall review and sign an "After-Hour Use Agreement" that outlines their responsibility for energy and water conservation and solid waste management. 2. Staff shall keep exterior doors and windows closed when mechanical heating and cooling is on. 3. Operable windows can be used for passive ventilation and cooling, with the knowledge that this will increase the introduction of pollen, dust and insects into the workplace. 4. Staff members are responsible for closing windows, blinds, drapes, and shades in their individual work spaces at the end of each day to minimize heat transfer. D. WATER MANAGEMENT 1. Building plumbing and irrigation equipment leaks should be reported immediately. A small leak can result in significant waste (and cost) if left unattended. 2. Appliances that use water (dishwashers, washing machines) should be run with full loads only, and use water miser settings. E. SOLID WASTE MANAGEMENT 1. Reducing waste is the overall goal. Reusing and recycling materials are better than sending material to the landfill, but are inferior methods to reducing waste. 2. The Resource Conservation Manager and interested staff members will partner in the development of a comprehensive material reduction and recycling program for all facilities, and will support staff training regarding appropriate and efficient waste sorting and handling methods. Exhibit A—Resolution 12-025 Resource Management Plan 04/16/12 Page 14 of 14 Appendix 8 City of Port Townsend — RCM Program Facility List Site ID Site Name Address City Facility Size (Sq. Ft.) CPT001 City Hall Annex 250 Madison St Port Townsend 11,795 CPT002 Historic City Hall 540 Water St Port Townsend 11,795 CPT004 Library Pink House 1256 Lawrence St Port Townsend 2,070 CPT005 Water Quality/Housing 5210 Kuhn St Port Townsend 1,443 CPT006 Cotton Building 607 Water St Port Townsend 4,018 CPT007 Mountain View 1925 Blaine St Port Townsend 27,600 CPT008 Mountain View Modular B (YMCA) 1925 Blaine St Port Townsend 2,400 CPT009 Mountain View Modular A (Radio) 1925 Blaine St Port Townsend 1,050 CPT010 Pope Marine 50 Water St Port Townsend 1,500 CPT011 Biosolids 603 Landfill Road Port Townsend 200 CPT012 Chetzemoka Park Office Jackson St Port Townsend 797 CPT013 Haller Fountain Taylor& Washington Port Townsend CPT014 Chetzemoka Park Restroom Jackson St Port Townsend 500 CPT015 Kah Tai Lagoon Nature Park 12th & Landis Port Townsend 250 CPT016 WWT plant 5300 Kuhn St Port Townsend 2,700 CPT017 Equipment Repair Shop 1800 Redwood St Port Townsend 6,100 CPT018 Equipment Repair Shop#3 1818 Beech St Port Townsend 4,017 CPT019 Equipment Repair Shop#2 1818 Beech St Port Townsend 3,225 CPT020 Maintenance Shop Modular#1 1818 Beech St Port Townsend 860 CPT021 Maintenance Shop Modular#2 1818 Beech St Port Townsend 860