CITY OF PORT TOWNSEND
BUILDER'S PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 before 3:00 p.m. for next day Inspection
Permit Number: BLD(I$-227 Issued: 12/30/05 Parcel Number: 931401 801
Job Address: 2911 20th Street Zoning: P-1 Occupancy: NA
Nature of Work: Reaair and maintenance of Wireless facility for Cinaular Wireless
Owner: City of Port Townsend/CInQUIar Wireless Contractor: TBD -see Condition #1
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
ELECTRICAL (WA State Labor and Industries)
NOTE: Sp ecial Inspection reauired for the use of High-streneth bolting per IBC 1704.3.
Special Ins pection Reports shall indicate compliance with the plans and specifications and
shall be co pied to the Building Department in a timely manner Permit Holder or Permit
Holder's A gent shall review and oversee correction of any and all deficiencies noted by
required special inspections.
RF.nTTTRFT) TNSPF,CTTnNS APPROVED/DATE
All new steel shall be minimum Grade 60
Any new horizontal reinforcing steel shall be supported
on chairs or dobies
COAX SUPPORT RACK CONNECTION
Connection bolts shall be A325 per plans -special
inspection required
Wedge anchors, 3/8" dia. A307 bolt, into concrete with
minimum 1 ''/z" embedment; call for inspection to
verify embedment prior to placement
Catl 48 hours before you dig for utility locates
1-800-424-5555
Page 1 of 2
k
Building Permit#BLDOS-l9l
CABINET ANCHORING
3/8"A307 threaded rod, embed 3" minimum into slab;
secure with HILTI HYI50 Injection Adhesive; call for
inspection to verify embedment and adhesive prior to
placement
FINAL INSPECTION
GENERAL CONDITIONS
Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a Citv business license. Failure to provide proof of this
documentation prior to work may result in job shut down while this is accomplished.
2. A sepazate electrical permit is required for any electrical work.
3. Re-inspections are required after any corrections are complete.
4. Final Inspections and approvals are required.
5. All Building Permits expire if no progress has been made within six months or, if no
inspections have been made by the Building Department within one yeaz. Call for at least
one inspection per yeaz to keep your permit active.
6. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-3208 prior to making changes to the approved plans.
7. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
APPLICANT SIGNATURE DATE
Ca1148 hours before you dig for utility locates
1-800-424-5555
Page 2 0[ 2
of pOPT Tp~
A, ~ CITY OF PORT TOWNSEND
o DEVELOPMENT SERVICES DEPARTMENT
~;;:
"' INSPECTION REPORT
~~ WAS
For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want
the inspection. For Monday inspections, call by 3:00 PM Friday.
DATE OF INSPECTION: o ~ D ~ PERMIT NUMBER: `~ I.,I;~ (~ ~ - ,~~~
SITE ADDRESS: aq ~ I ~-J~'~}'
PROJECT NAME: ~,I ~/;( ~g,~ CONTRACTOR:
CONTACT PERSON: ~ ~~~ PHONE: ~Z~ - Q 7 f - (~ ~f (pO
TYPE OF INSPECTION: }--I Yl L"LI
~., ~-
`:
O
^ APPROVED
,_ _ _ _..
'~
.~ / /
Inspector /~ ~ ' `~ ~
C APPROVED WITH
CORRECTIONS
Ok to proceed. Corrections will be
checked at nextinspection
Date
C NOT APPROVED
Call for re-inspection before
proceeding. ~
7%f ~ ,/
Approved plans and permit card must be on-site and available at lime of inspection. A re-inspection fee may
6e assessed if work is not ready for inspection.
FIELD REPORT NO: 72277
~~~~ & ASSOCIATES,INC.
GE OiECHNICAI ENGINEERING • ENVIRONMENiAi ENGINEERING
CO NSi RU CiION TESTING & INSPECTION
DATE: April 13, 2007
PROJECT #: 106-07
Penn
LOCATION• 450 Firs Street Pt Townsend WA JuRls~lc I IUN: Jefferson t;ounty
KRAZAN PROJECT MANAGER: JONB WEATHER: Overcast TEMP: 46°
Inspected completed installation of 3/8" expansion anchors for equipment cabinet. Verified anchor size
and embedment conformed to design drawings. Verified installation torque met manufacturer's
requirement.
Visually inspected ice bridge support clamps. All piles of galvanized U-bolt bracket and nut assembly
appear to be drawn fully together in a snug tight condition.
The above work is acceptable to the best my knowledge, information, and belief, based on the extent of
services performed and that all work has been completed and is in accordance with the contract
documents, and design requirements as noted in the site construction drawings.
,~
rj r i
• ~
7o my best of knowledge, the above WAS/WAS NOT performed in accordance with the approved plans, spedfications, and regulatory
requirements.
SuperintendenURepresentative: Technician: r
~~ ~
Serving the Western United States
1501 Kidd /igxx0.dx Re~i,inn 1
le(Arire lknr:5'i 0>
II-f nn mpr 'liur rAi.-nynr i., pr.pum,U ~'~-I.u,.ro/h l t!!ao'eprvvun,'nnNrnlnrnl ~l nAru,n~, hf.,e lOnrp,r 7ledinu lk- nn A'dwx mu.
~oF~onrrO"% CITY OF PORT TOWNSEND
g DEVELOPMENT SERVICES DEPARTMENT
"`~ INSPECTION REPORT
~-_
~~~ For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want
the inspection. For Monday inspections, call by 3:00 PM Friday.
DATE OF INSPECTION: -I PERMIT NUMBER: Igo O(o ' ~..27
SITE ADDRESS: ~`~ ,~~'~}e~~ r iC k S
PROJECT NAME: CONTRACTOR: ~~ Mh(' L ~ ' (~1'V~ I S
CONTACT PERSON: ~l CIC__`` PHONE: c~(~ ~ /^4 ~q
TYPE OF INSPECTION: ~ Ir'r"Qr2.I~Q.~I r)pCU(`DL~(~~n-~ `~ / ~ ~~ /l`
,'
j,
_ ___
-- -- ,
,~ , d ~ ~~:
^ APPROVED ^ APPROVED WITH ^ NOT APPROVED
CORRECTIONS
-z~._.-_-___-_-___ _. _..
_-- "- Ok to proceed. Corrections will be Call for re-inspection before
checked at next inspection proceeding.
..- ~~ .__
Inspector °r' `' _._ Date `~ t i i
Apyroved plans and permit ca~'d must be on-site and available at time of inspection. ^ re-inspeclion fee may
be assessed if x~ork is not ready for- inspection.