HomeMy WebLinkAboutBLD05-227 ~. City of Port Townsend I81 Quincy Stree[ Su¢e 301 Port TownsenQ WA98368 Phone (360) 344-3057 Fax (360) 385-7675 CITY OF PORT TOWNSEND BUILDER'S PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 before 3:00 p.m. for next day Inspection Permit Number: BLD(I$-227 Issued: 12/30/05 Parcel Number: 931401 801 Job Address: 2911 20th Street Zoning: P-1 Occupancy: NA Nature of Work: Reaair and maintenance of Wireless facility for Cinaular Wireless Owner: City of Port Townsend/CInQUIar Wireless Contractor: TBD -see Condition #1 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: ELECTRICAL (WA State Labor and Industries) NOTE: Sp ecial Inspection reauired for the use of High-streneth bolting per IBC 1704.3. Special Ins pection Reports shall indicate compliance with the plans and specifications and shall be co pied to the Building Department in a timely manner Permit Holder or Permit Holder's A gent shall review and oversee correction of any and all deficiencies noted by required special inspections. RF.nTTTRFT) TNSPF,CTTnNS APPROVED/DATE All new steel shall be minimum Grade 60 Any new horizontal reinforcing steel shall be supported on chairs or dobies COAX SUPPORT RACK CONNECTION Connection bolts shall be A325 per plans -special inspection required Wedge anchors, 3/8" dia. A307 bolt, into concrete with minimum 1 ''/z" embedment; call for inspection to verify embedment prior to placement Catl 48 hours before you dig for utility locates 1-800-424-5555 Page 1 of 2 k Building Permit#BLDOS-l9l CABINET ANCHORING 3/8"A307 threaded rod, embed 3" minimum into slab; secure with HILTI HYI50 Injection Adhesive; call for inspection to verify embedment and adhesive prior to placement FINAL INSPECTION GENERAL CONDITIONS Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a Citv business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. A sepazate electrical permit is required for any electrical work. 3. Re-inspections are required after any corrections are complete. 4. Final Inspections and approvals are required. 5. All Building Permits expire if no progress has been made within six months or, if no inspections have been made by the Building Department within one yeaz. Call for at least one inspection per yeaz to keep your permit active. 6. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 7. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. APPLICANT SIGNATURE DATE Ca1148 hours before you dig for utility locates 1-800-424-5555 Page 2 0[ 2 of pOPT Tp~ A, ~ CITY OF PORT TOWNSEND o DEVELOPMENT SERVICES DEPARTMENT ~;;: "' INSPECTION REPORT ~~ WAS For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: o ~ D ~ PERMIT NUMBER: `~ I.,I;~ (~ ~ - ,~~~ SITE ADDRESS: aq ~ I ~-J~'~}' PROJECT NAME: ~,I ~/;( ~g,~ CONTRACTOR: CONTACT PERSON: ~ ~~~ PHONE: ~Z~ - Q 7 f - (~ ~f (pO TYPE OF INSPECTION: }--I Yl L"LI ~., ~- `: O ^ APPROVED ,_ _ _ _.. '~ .~ / / Inspector /~ ~ ' `~ ~ C APPROVED WITH CORRECTIONS Ok to proceed. Corrections will be checked at nextinspection Date C NOT APPROVED Call for re-inspection before proceeding. ~ 7%f ~ ,/ Approved plans and permit card must be on-site and available at lime of inspection. A re-inspection fee may 6e assessed if work is not ready for inspection. FIELD REPORT NO: 72277 ~~~~ & ASSOCIATES,INC. GE OiECHNICAI ENGINEERING • ENVIRONMENiAi ENGINEERING CO NSi RU CiION TESTING & INSPECTION DATE: April 13, 2007 PROJECT #: 106-07 Penn LOCATION• 450 Firs Street Pt Townsend WA JuRls~lc I IUN: Jefferson t;ounty KRAZAN PROJECT MANAGER: JONB WEATHER: Overcast TEMP: 46° Inspected completed installation of 3/8" expansion anchors for equipment cabinet. Verified anchor size and embedment conformed to design drawings. Verified installation torque met manufacturer's requirement. Visually inspected ice bridge support clamps. All piles of galvanized U-bolt bracket and nut assembly appear to be drawn fully together in a snug tight condition. The above work is acceptable to the best my knowledge, information, and belief, based on the extent of services performed and that all work has been completed and is in accordance with the contract documents, and design requirements as noted in the site construction drawings. ,~ rj r i • ~ 7o my best of knowledge, the above WAS/WAS NOT performed in accordance with the approved plans, spedfications, and regulatory requirements. SuperintendenURepresentative: Technician: r ~~ ~ Serving the Western United States 1501 Kidd /igxx0.dx Re~i,inn 1 le(Arire lknr:5'i 0> II-f nn mpr 'liur rAi.-nynr i., pr.pum,U ~'~-I.u,.ro/h l t!!ao'eprvvun,'nnNrnlnrnl ~l nAru,n~, hf.,e lOnrp,r 7ledinu lk- nn A'dwx mu. ~oF~onrrO"% CITY OF PORT TOWNSEND g DEVELOPMENT SERVICES DEPARTMENT "`~ INSPECTION REPORT ~-_ ~~~ For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: -I PERMIT NUMBER: Igo O(o ' ~..27 SITE ADDRESS: ~`~ ,~~'~}e~~ r iC k S PROJECT NAME: CONTRACTOR: ~~ Mh(' L ~ ' (~1'V~ I S CONTACT PERSON: ~l CIC__`` PHONE: c~(~ ~ /^4 ~q TYPE OF INSPECTION: ~ Ir'r"Qr2.I~Q.~I r)pCU(`DL~(~~n-~ `~ / ~ ~~ /l` ,' j, _ ___ -- -- , ,~ , d ~ ~~: ^ APPROVED ^ APPROVED WITH ^ NOT APPROVED CORRECTIONS -z~._.-_-___-_-___ _. _.. _-- "- Ok to proceed. Corrections will be Call for re-inspection before checked at next inspection proceeding. ..- ~~ .__ Inspector °r' `' _._ Date `~ t i i Apyroved plans and permit ca~'d must be on-site and available at time of inspection. ^ re-inspeclion fee may be assessed if x~ork is not ready for- inspection.