HomeMy WebLinkAboutBLD05-183Permit mBLD05-183
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: $I~D~S-1g3
Issued: 11/02/05
Job Address: 825 Washington St.
Total Occupant Load: 6
APPROVED BY: DATE:
Parcel Number: 989-704-109
Zoning: C-IH Type: VV=B Occupancy: R3
Nature of Work: Interior remodel for 3 condominium units
Owner: Ritch Sorgen & Marlies Egberding Contractor: Newland Construction Co. Inc. -
NEWLAC*343L0
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF.nTTTRFI) TNCPF.('TTfINS
APPRnVF.1)/nATF,
DEMOLITION
All materials to be dis osed o in an ap roved land all.
"SPECIAL INSPECTION REQUIRED FOR EPOXY
SETS" -The owner shall employ one or more special
inspectors to provide inspections during construction on the
type of work listed here. The special inspector shall be a
quaked person who shall demonstrate competence, to the
satisfaction of the building official, for inspection of the
particular type construction requiring special inspection.
Submit reports to the Ci of Port Townsend - Buildin De t.
PORT TOWNSEND HISTORIC PRESERVATION
COMMITTEE REQUIRES SUBMISSION & APPROVAL
OF NEW OVERHEAD SPECIFICATIONS PRIOR TO
INSTALLATION.
PORT TOWNSEND HISTORIC PRESERVATION
COMMITTEE REQUIRES SUBMISSION & APPROVAL
OF CHANGED WINDOWS ALONG ALLEY/DRIVEWAY
PRIOR TO FABRICATION & INSTALLATION.
PORT TOWNSEND HISTORIC PRESERVATION
COMMITTEE REQUIRES SUBMISSION & APPROVAL
OF DETAILS & SPECIFICATIONS FOR AWNING
ABOVE MAN-DOOR ALONG WASHINGTON STREET.
Pemtic MBI.DOS-183
FIRE DEPT. REQUIREMENT
3rd Party Review for automatic fire detection alarm system -
alterations must comply w/ NFPA. Fire Dept. shall approve
alterations prior to commencing work.
Fire Extinguishers @ stair foyer of each floor level.
Afl other re uirements of Plan Review memo dated 10/21/05.
CMU
New Openings - 3 - %z" thru rod epoxy set into existing CMU
wall
CMU Inf-ll
2 - #4 vert & 2 - #4 horiz. 48" o.c. 2 places min.
Epoxy dowel
PLUMBING
Rough-in (D-V-T & cleanouts)
Water Supply
Water Hammer Arrester
Pipe Insulation (R-3)
Drain, waste & vent
Water supply - R-3 insulation outside of conditioned space
Pressure Reduction Valve required
Water Heater
Strap @ 1/3 points
Pressure Relief Valve drain to exterior, pointed down,
terminate 6" - 24" above ground
Appliances
Licensed Plumbing Contractor's Signature & License
Number
Signature•
MECHANICAL
Bathroom/Kitchen/Laundry Room Fans
Whole House Fans
Environmental Air Exhaust ducting (w/ back draft dampers),
insulation (R-4) and terminus located 3' from o enin s)
FRAMING -per design details on plans
PLS Beams
Grout Dam
Bond Beam
Hangers
Grout
Walls
Ceiling
Posts, Beams & Headers
Positive Connections
Plates
Fresh Air Intakes
Windows -egress
Safety Glazin
Permit ABL~OS-183
Walls
Air Seal
Fire blockin
INSULATION -DEFERRED SUBMITTAL
Walls
Ceiling
Floor
Vapor Barrier: paint for walls & ceiling
FINAL
Building Numbers -minimum 5"
Historic Preservation Committee
Fire Department
Electrical (L & I)
Plumbing
Mechanical
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Final -Building
Permit #SLDOS-l83
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department 344-3057 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
~~