HomeMy WebLinkAboutBLD05-094~ s
CITY OF PORT TOWNSEND
peveloproent Services Geparhnent
250 Madison Street, Sui[e 3
Port Townsend, WA 98368
Phone: (360) 379-3208 Pax: (360) 344-0619
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
For Next Day Inspection Ca11385-2294 Before 3P.M.
~. ~,
Permit Number: BLDOS-094 Issued: 9/7/06
Job Address: 1703 Taylor Ln. Zoning: RR^II
Nature of Work: Construct single-family residence
Owners: C.L. Flint/Garrison
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
Parcel Number: 970 101 101
Type: VV=B Occupancy: R-3
Contractor: Need
NOTE: ACQUAINT YOURSELF WITH THE LISTED REQUIRMENTS TO
RECEIVE FINAL BUILIDNG INSPECTION PRIOR TO THE START OF
CONSTRUCTION AND PRIOR TO YOUR REQUEST FOR FINAL INSPECTION.
*** Al[ elements of engineering including holdowns, framing, nailing and other engineering connections
require inspection prior to cover. ***
RF.IIiiiRFTI iNCPFf'TiONS
APPRnVF,D/DATF.
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving the site
FOOTINGS
Setbacks
Footings
Reinforcement
Holdowns MUST BE TIED IN PLACE
NO WET STICKING)
Anchor Bolts & Washers
LIFER Ground (tied to footing rebar steel)
Interior Pads
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page t oT 4
Permit #BLDOS-094
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrester (on dishwasher, ice maker & clothes
washer)
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve required
Water Heater
Seismic Restraint -strap tank ~ 1/3 points
Pressure relief valve drain to exterior, terminate
6"-24" above ground
Expansion tank
Licensed Plumbing Contractor's Signature & License
Number•
Sign here
Shear wall nailing (TO BE INSPECTED &
APPROVED PRIOR TO COVERING)
MECHANICAL
Whole House Fan W/ 2A hour timer
Kitchen/Bath/Laundry Fans
Environmental Air Exhaust ducting (w/ back draft dampers),
Insulation (R-4) (on duating in unheated space)
LPG Tank
LPG Piping
LPG Stove
LPG Heater
FRAMING -alt members and connections require inspection
prior to cover
Fasteners hangers etc. in contact with treated material must be
hot dipped galvanized
Walls
Headers
Rafters (hurricane clips)
Roof Sheathing
Joists (hangers)
Cable X-Bracing
Blocking
Stairs
Roof Venting - eave and ridge vents
Windows -egress
Smoke detectors (bedrooms, outside bedrooms and each floor)
Safety Glazing
W indows U factor - .40 or better
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
i
Permit #BLDOS-094
Doors U-factor-.20 or better
NFRC window sticker must be on window, skylights & doors at
insp. time.
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R-10)
Walls (R-21)
Vault (R-30)
Vapor Barrier: paint for walls and ceiling
Baffles
DRYWALL
PUBLIC WORKS FINAL - SDP06-050
Public Works Si n-Off rior to buildin final
FINAL
Parking-2 space required
House Numbers - 5" minimum
Plumbing
Mechanical/Heating
LPG
Vapor Barrier Paint Certificate i
Insulation Certificate
Smoke Detectors
Final -Building
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
Permit#BLDOS-094
CFNERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
9. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
APPLICANT SIGNATURE
DATE
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
i ~
of°~pTrOw CITY OF PORT TOWNSEND
o DEVELOPMENT SERVICES DEPARTMENT
'"_" INSPECTION REPORT
~ • `
~~wn
Far inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before yon want
the inspection. For Monday inspections, call by 3:00 PM Friday.
DATE OF INSPECTION: PERMIT NUMBER: ~ - ~
SITE ADDRESS: r ~
PROJECT NAME: T~ ~ l y1 j-- CO`N~RACTOR:
CONTACT PERSON: V (? r h PHONE: ~-] q ~, ~j ~~
TYPE OF INSPECTION: 1~~~ ~,~( ~
___
~ ~ i ,
- - ~
,i_ ~r ~, /
C APPROVED ^ APPROVEDW'ITH ^ NOT APPROVED
CORRECTIONS
- - Ok to proceed. Corrections will be Call for re-inspection before
checked at nextinspection proceeding.
.r _ ~
Inspector r Date _ ' ~'_ j
Approved plans and permit card must be on-site and availahle at time of inspection. fl re-inspection fee may
be assessed if work is not read}~ for inspection.