CITY OF PORT TOWNSEND
DEVELOPMENT SERVICES DEPARTMENT
INSPECTION REPORT
3 %~ f
,,F ~` __
- - - - --
Contractor ~ ~ ~ "` "`-
Owner
Date of Inspection
Worksite or Cell Phone#
l 1. , . t k:~ ....
^ Erosion/Sediment Control
^ Setbacks/Footings/LIFER
^ Foundation Walls
^ Footing Drainage
^ Slab/Interior Footing/Insulation
^ Groundwork/Plumbing Test
^ Underfloor Framing
^ Ext. Shear Wall/Holdowns
Plumbing/Top Out
^ Propane Pipe/Pressure Test
^ Propane Tank/Line
^ Mechanical
C~' Framing
Insulation
^ Interior Shear/BWP Nail
Drywall/Fire Wall
^ Propane/Wood Appliance
Manufactured Home Set-up
Fire Department
^ Temporary Occupancy
^ Fees Paid
^ 1`inal Occupancy
:=1 Other/Consu Itation
Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message
Line at (360) 385-2294 prior to 8:00 AM. (NO OCCUPANCY UNTIL APPROVED BY DSD.
_- - - OCCUPANCY REQUIRES WRITTEN APPROVAL BY DSD.)
^ APPROVED ^ APPROVED WITH CORRECTIONS ^ NOT APPROVED
~~ SEE BELOW SEE COMMENT(S) BELOW
1
i f,
I
4 i~{ Viz:;
Approved pans and permit ca~ryd' must be on-site and available at time of inspection.
Inspector ~ - ~};~' - Date %~` ~ r-
Acknowledged by ~ ~ Date
Wazertnao & Katz Building
ISI Quincy Street, Suite 301
Potl Townsend, WA 96368
Phona: (360) 379-3208 Fax: (360) 3857675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: $LDOS-O71 Issued: 04/19/05 Parcel Number: 989 704 001
Job Address: 225 Taylar Street Zoning: C-III Type: VV=B Occupancy: A_2
Total Occupant Load: NA Nature of Work: Renair rear stairs for use by dining establishments.
Owner: (Sam Kvlel Mount Baker Block Corporation Contractor: Same as Owner
GENERAL CONDITIONS APPLY -SEE PAGES 2 & 3
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360.417-2702
RFnTTTRF,D TNRPF.C'TTnNS
APPRnVF,D/DATE
DEMOLITION -Demolition materials shall be transported to
the Jefferson County landfll or other approved location in
accordance with all state and local laws and ordinances
Remove and dispose of unused electrical wires, nails, conduit,
eta (Item #2 of plans)
FRAMING -per design details; all details require inspection
prior to cover
Stair Stringers (Item #3 of plans)
Posts -all posts shall be true and plumb; straighten post west of
stairs (Item #4 of plans)
Closure Panel -provide 2 x 12 treated panel @ top riser of
Landing (Item #4 of plans); provide closure for other treads as
open risers are not permitted
Positive Connection @ each post and roof beam -Simpson AC
or ACE @ each side of connection (Item #5 of plans)
Replace dry rot post @ east corner, upper floor level below
deck -replace minimum top 10" of post with new treated 4" x
6" post; provide Simpson BC460 connector between new and
existing; install 1" x 6" splice plates @ two sides (Item #6 of
plans)
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 1
Pumit kBLD05071
RF,OiJiRED INSPECTIONS APPROVED/DATE
Slip-Resistant Surface @ stairs, decks and landings (Item #7)
Stringer Supports -add (2) treated 2" x 10" @ ends to restrain
stringer supports from moving (Item #8 of plans)
Post to Column Supports -add 2" x 12" with (6) 10d
galvanized nails to each column (Item #9 of plans)
Guardrail Supports -provide (2) 3/8" x 6" Titen masonry
anchors with 2" washers at each support (Item #10 of plans)
Postto Deck Connection -provide (2) Simpson A33 angles at
sides of column base (Item #11)
Preservative Treatment - as existing stairs are constructed of
untreated wood, apply bituminous coating at lower 6" of each
post (columns, landings, etc.). In addition, anoil-based
preservative coating (e.g. Cabot's Bleach-tox) shall be applied
over all other wood to reduce dry rot and deterioration (Item
#1 of plans
Exterior landing shall have maximum slope of/4":1 foot
Guardrails shall be minimum 36" in height
Intermediate rails at maximum 4" o.c. spacing
Handrails shall be minimum 30" high; provide grippable
surface
FINAL
Final -Building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
re¢istration number and a City business license. Failure to provide proof of this documentation prior to
work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Soils exposed during construction shall be
temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with
seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
Permit #BLDOS07l
5. Re-inspection is required after any corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294; a
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-STTE WITH THE APPROVED PLANS.