Loading...
HomeMy WebLinkAboutBLD05-007Waterman & Katz 181 Quincy Street Suite 301 Port Townsend, WA 98368 Phone (360) 344-3057 Fax (360) 385-7fi75 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDOS-OO7 Issued: 10/13/05 Parcel Number: 989 705 203 Job Address: 300 Block of Monroe Street Zoning: P/OS(B) Nature of Work: Construct skateboard park, locate minimum (1) accessible restroom and construct restroom shelter, provide accessible route of travel to picnic table area. Construction shall proceed with intent of plans dated 03/02/05 by Robert Droll, Landscape Architect. Minor field chances in design and location (see 8/23/05 plans by Dreamland Skateparks) approved in concept by above Landscape Architect. Submit as-bunts upon proiect completion. Owner: Permit Approved .;~,.. ~S P NOTE: Hours of construction are limited to 7 a.m. to 6 p.m. Monday through Friday and prohibited on weekends and national holidays. **** No heavy equipment or construction materials may be stored or parked on any nearby beaches or below the Ordinary High Water Mark (OHWM)**** RE UIRED INSPECTIONS APPROVED/DATE TESC Temporary erosion and sediment controls shall be installed per the approved plan and inspected prior to commencing construction activity DEMOLITION Materials from demolition shall be taken to an approved disposal facility in accordance with all state and local laws and regulations FOOTINGS -all concrete speed at 3500 psi; 3000 psl for picnic table footing Footing Drains Forms -heel, toe, width Reinforcement -minimum grade 60 Retaining Wall Footing -refer to sheet l3/I9 Reinforcement Verts and L Dowels Call 48 hours before you dig utility line locates: 1-800-424-5555 Page I of 1 i . Permit # B6DOS007 RFnTTTRF.D TNSPF,CTTnNS APPROVED/DATE STEM WALL -see plans for varying details 12" typical U.N.O. Reinforcement -minimum grade 60 RETAINING WALL -refer to sheet 13/19; reinforcement #5 typical Heel Reinforcement - Toe Reinforcement Verticals L Dowels SLAB Thickened Footings Positive Connections Speed Dowels - 18" #4 bar @ 24" o.c. U.N.O. STAIRS A-I & A-2 Reinforcement Rise-4"-7" Run - 11" minimum Nosings - %z" max. typical Grooves for slip-resistance typical all stairs Slope -'/4":12" typical all stairs STAIRS B Reinforcement Rise Run Nosings Grooves Slope Handrails FENCE INSTALLATION Refer to Sheet 14/19 0 Z LANDSCAPING AND IRRIGATION PARKING PARK USE AND RULES SIGNAGE FINAL -per architect design Public Works Approval Stairs & Handrails ^ - Accessible Route of Travel to facility/picnic bench area - > . - AccessibleRestroom ~~~'~^~%"-~ Fence -painted per HPC requirements Final -building Call 48 hours before you dig utility line locates: 1-80D-424-5555 Page 2 of 2 • • Permit # fl[,DOS007 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass £inal inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's £mal inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig utility line locates: 1-800-424-5555 Page 3 of 3