CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDOS-OO7 Issued: 10/13/05 Parcel Number: 989 705 203
Job Address: 300 Block of Monroe Street Zoning: P/OS(B)
Nature of Work: Construct skateboard park, locate minimum (1) accessible restroom and construct
restroom shelter, provide accessible route of travel to picnic table area. Construction shall proceed
with intent of plans dated 03/02/05 by Robert Droll, Landscape Architect. Minor field chances in
design and location (see 8/23/05 plans by Dreamland Skateparks) approved in concept by above
Landscape Architect. Submit as-bunts upon proiect completion.
Owner:
Permit Approved
.;~,.. ~S
P
NOTE: Hours of construction are limited to 7 a.m. to 6 p.m. Monday through Friday
and prohibited on weekends and national holidays.
**** No heavy equipment or construction materials may be stored or parked on any
nearby beaches or below the Ordinary High Water Mark (OHWM)****
RE UIRED INSPECTIONS
APPROVED/DATE
TESC
Temporary erosion and sediment controls shall be installed per
the approved plan and inspected prior to commencing
construction activity
DEMOLITION
Materials from demolition shall be taken to an approved
disposal facility in accordance with all state and local laws and
regulations
FOOTINGS -all concrete speed at 3500 psi; 3000 psl for
picnic table footing
Footing Drains
Forms -heel, toe, width
Reinforcement -minimum grade 60
Retaining Wall Footing -refer to sheet l3/I9
Reinforcement
Verts and L Dowels
Call 48 hours before you dig utility line locates: 1-800-424-5555
Page I of 1
i . Permit # B6DOS007
RFnTTTRF.D TNSPF,CTTnNS
APPROVED/DATE
STEM WALL -see plans for varying details
12" typical U.N.O.
Reinforcement -minimum grade 60
RETAINING WALL -refer to sheet 13/19; reinforcement
#5 typical
Heel Reinforcement -
Toe Reinforcement
Verticals
L Dowels
SLAB
Thickened Footings
Positive Connections
Speed Dowels - 18" #4 bar @ 24" o.c. U.N.O.
STAIRS A-I & A-2
Reinforcement
Rise-4"-7"
Run - 11" minimum
Nosings - %z" max. typical
Grooves for slip-resistance typical all stairs
Slope -'/4":12" typical all stairs
STAIRS B
Reinforcement
Rise
Run
Nosings
Grooves
Slope
Handrails
FENCE INSTALLATION
Refer to Sheet 14/19 0 Z
LANDSCAPING AND IRRIGATION
PARKING
PARK USE AND RULES SIGNAGE
FINAL -per architect design
Public Works Approval
Stairs & Handrails ^ -
Accessible Route of Travel to facility/picnic bench area - > . -
AccessibleRestroom ~~~'~^~%"-~
Fence -painted per HPC requirements
Final -building
Call 48 hours before you dig utility line locates: 1-80D-424-5555
Page 2 of 2
•
• Permit # fl[,DOS007
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; ca11385-2294. Measures shall include installation of
silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way
shall be kept free of dirt debris. Soils exposed during construction shall be temporarily
stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding,
plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass £inal inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received
prior to scheduling the Building Department's £mal inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year
to keep your building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the
Building Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig utility line locates: 1-800-424-5555
Page 3 of 3