HomeMy WebLinkAboutBLD04-207Waterman and Ka[z Building
I81 Quincy Street, Suite 307
Port iownsen4 WA 96368
Phone: (360)379-3208 Fax: (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO4-2O7 Issued: 07/27/04 Parcel Number: 989 713 507
Job Address: 1031 Lawrence Street Zoning: C-III Type: VV=N Occupancy: M
Total Occupant Load: N/C
Nature of Work: Demo subfloor for discovery: replace subfloor and ioists as needed: install
new French doors to replace existing door, insulate ceiling, build landing,
steps, handrail for new french doors for "Petals Flower Shop"
Owner: Malcolm Dorn Contractor: Enterlight ENTER**06501
GENERAL CONDITIONS APPLY: See last page
SEPARATE PERMITS REQUIRED:
Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702
Sign Permit -contact Jean Walat @ 385-0644
RE UIRED INSPECTIONS
APPROVED/DATE
DEMOLITION
Materials from demolition shall be taken to the Jefferson
County Landfill or other approved location
FLOOR FRAMING
Joists -pressure treated required within 18" of
earth; hot dipped galvanized fasteners to be used
in contact with pressure treated wood
Blocking
Positive Connections
6 mil black poly on ground in under floor space
FRAMING
Doors -''/2" maximum threshold
Lever Hazdware
Air Seal
Door Safety Glazing
Landing/Steps-pressure treated wood or wood of natural
resistance to decay required
Handrail
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Building Permit#BLD04207
RE UIRED INSPECTIONS
APPROVED/DATE
INSULATION -existing conditioned space
Floor -Insulate exposed floor cavities
Ceiling - R-19 per attached calculations
Baffles with 1" air above
DRYWALL NAILING (if applicable)
Wa11s
FINAL
Building Numbers -minimum 5" numbers
Fire Department Sign Off
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries
contractor's registration number and a City business license. Failure to provide proof of
this documentation prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include
installation of silt fencing and graveled construction entrance (see attached details).
Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible far protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced
wall panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies
noted by required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public
Works requirements have been completed and inspected. For Public Works inspection call
385-2294. A minimum of twenty-four hours notice is required. Public Works approval
must be received prior to scheduling the Building Department's final inspection.
Final Inspections are required prior to occupancy; A Certificate of Occupancy is required
for anon-residential project.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
Building Peimi[ NBLD04207
8. All building permits expire if no progress has been made within six months, or if no
inspections are done by the Building Department within one year. Call for at least one
inspection per year to keep your building permit active.
9. Revisions require review and approval prior to making changes in the Tield. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERNIIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
YQOflTTOk
~ ~s
i F
U O
-- -` ~o:
~~ WA`+M~
PERMIT NUMBER:
Site Address
Contract~•
Owner
Date of li
Worksite or Cell Phone#
^ Sewer Main /Manhole
^ Side Sewer
^ Water Main
^ Street Prep
CITY OF PORT TOWNSEND
STREET & UTILITY INSPECTION REPORT
^ Street Paving
^ Driveway Prep /Installation
^ Storm Drainage /Culvert
^ Trail(s)
^ Erosion /Sediment Control
^ Hydrant
^ ROW Landscaping
^ Temporary Occupancy
^ Final Infrastructure
Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message
Line at (360) 385-2294 prior to 8:00 AM. (NO OCCUPANCY UNTIL APPROVED BY DSD.)
^ APPROVED ^ APPROVED WITH CORRECTIONS NOT APPROVED
SEE BELOW SEE COMMENT(S) BELOW
~bN- Z~ ^7
Approved
Inspector
Acknowle
s and permit card must
by
on-site a d available at time of inspection.
~~~ Date g` ~ ~
Date
°~"~p'T°""~s~ CITY OF PORT TOWNSEND PUBLIC WORKS &
U DEVELOPMENT SERVICES DEPARTMENT
~;°:. , °_
'' - " U~ INSPECTION REPORT
eOFwnsN`a
PERMIT NUMBER: ~~--.~~~~~~ ^ ~~' 7
Address ~ ~~ ~ I C~Lr,'t~"'~'4n (~% ~ ( `
~n~
Contractor
Owner
Date of Inspection
Worksite or Cell Phone#
Erosion/Sedimentation
Setbacks/Footings/LIFER
^ Foundation Walls
^ Slab Interior Footing/Insulation
^ Groundwork/Plumbing Test
^ Underfloor Framing
^ Shear Wall/Holdowns
~~~
i;~ ~
rcl s~ ~ r'
bt~'
Z ~~5
Plumbing/Top Out ^ Drywall/Fire Wall
Gas Pipe/Pressure Test U Gas/Wood Appliance
Propane Tank/Line ^ Manufactured Home Set-up
Mechanical
Framing
Insulation
^ Interior Shear/BWP Nail
Public Works
OtheriConsuflation
FINAL
If corrections required, re-inspection must be done prior to covering or concealing areas
of construction. Additional fees may be assessed for multiple re-inspections.
For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM.
NO OCCUPANCY UNTIL FINALIZED~ B~Y ~BUILDING AND, IF APPLICABLE, PUBLIC WORKS.
:J VIOLATION ~.9^PCF'F'ROVAL ^ CORRECTION REQUIRED
^ APPROVED WITH CORRECTION '^ NEED APPROVED PLANS & PERMIT ON SITE
Approved playz%, ark permit card
be on-site and available at time of inspection.
Inspector ~~'~r~' ~ ~r ~ ~.r/ Date ~ '-~ ~~ ~F
~i `
•B•