HomeMy WebLinkAboutBLD02-107 (2)` Waterman ~ Katz Buildio8
181 Quincy Sued, Suite 301
Port Towmend, WA 98368
phone: (360) 379-3208 Fax (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
TffiS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD02-1~7 Issued: 10/03/02 Parcel Number: 989800066& 989800067
Job Address: 884 West Park Zoning: M-C Type: V-N Occupancy: B
Total Occupant Load: 117 Nature of Work: Construct 4676 sa. ft. addition
Owner: Jefferson Mental Health Service Contractor: Little and Little Construction
LIIIZLC157C5
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMTTS REOUIItED:
Mechanical -Heat Pump Units and Ducting as Deferred Submittal
Lighting -Revision required for Daylight Zones & Controls
Electrical -Contact Labor & Industries @ 360-417-2702
Street & Utility Development Permit -contact Francesca Franklin @ 379-5093
Signage must conform to City regulations -contact Jean Walat @ 360-385-0644
RF.(1TTTRF.T) TNCPF.C'TT[~N~ APPROVED/DATE
TEMPORARY EROSION & SEDIMENT CONTROL
Temporary erosion and sediment control measures shall be
installed on-site as needed during construction to contain dirt
and sediment on-site. Adjacent rights-of--way shall be kept clean
through sweeping of paved surfaces, tire wash, etc.
l~~ ~..._/~_
l
FOOTINGS
Setbacks
~ /~/~~-
Concrete Plinth Footings
Forms
Vertical Resteel
Horizontal Ties
Treated Sill
Anchor Bolts
Engineered Holdown Hardware
GROUNDWORK PLUMBING
Pressure Test
IG~Z~OZ-
Pipe Joints Exposed
Pipe Bedding
Trap Seal Protection
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 5
Permit A.
MONOLITHIC SLAB
Forms
Reinforcement
Anchor Bolts
Treated Wood to Concrete
R-10 @ perimeter
Engineered Holdowns
UFER
PLUMBING: Barrier-Free Compliance Required
D-W-V Rough-In
Water Supply
Water Hammer Arrestors
Floor Drains -crap seal protection required
Pipe Insulation - R-3
Hose Bibbs - backflow protection required
Hot Water Heater
Seismic Restraint
PTR Valve Drain to exterior
MECHANICAL
HVAC -Heat Pump/Furnace Units & Ducting as deferred
submittal
NREC Temperature Zones
Thermostat Controls
Deadband Control
Setback with 7 different day types
Microprocessor controls with heat indicators
Dampers
Duct Insulation and Sealing
TE
(~lf~ov ~/
~-, ~- _ ~~~,~ (rata ~
~~°~
Call 48 hours before you dig for utility tine locates
1-800-424-5555
Page 2 of 5
t
~~ uB~ao~
72T11TT7T2Fil TNCPFf'TTf1NC APPROVED/DATE
'~
., _
FRAMING
Walls -Engineered Shear Walls --
l ~Z(p/d ~
Roof -Engineered truss plan to be on-site at time of
Inspection
Blocking .
Roof Drains
Attic Venting -plans. show gable enc~ ridge & eave
Window Safety Glazing
Window U-factor - .40 or better
Doors - . 60 or better
Air Seal
Rafter & Truss Positive Connections
Fire Blocking
Draft Stop
Weather Resistive Barrier 1 ?
~ ` ~ ~~
INSULATION
Walls - R-19
Roof - R-38 attic
Baffles
Vapor Barrier required - 4 mil poly, vapor barrier paint, etc.
R 10 @ slab perimeter `~/~~
DRYWALL
Walls
Ceiling
r//~ 03
LIGHTING -revision required to include dRVliQht zones
and controls
Exterior Lighting per NREC
High- or low-sodium tights recommended; metal halide
discouraged
Call 48 hours before you dig for utility line locates
1-800-4245555
Page 3 of 5
r ~ ~
Permit #BLD02-107
RF.(~T1TRF.n TNSPF.C.TTONS APPROVED/DATE
PARKING -Barrier Free required
(1) Van Accessible Space -tactile and visual detectable
warnings required where space crosses vehicular way
Accessible path of travel required from bus stop to main
entrance
LANDSCAPING
Contact John McDonagh @ 379-5085 for inspection
FINAL
Property address posted -min. 5"numbers
Public Works Department Sign-Off
Fire Department Sign-Off
Electrical Sign-off (L & I)
Barrier Free access
Plumbing -Barrier Free Required
Mechanical
Heating
WSVIAQ
Certification letter from installer stating compliance with
fresh air requirements
Restroom wall and floor covering per UBC 807
Insulation Certificate
Door panic hardware Main exit may have key locking
device with sign at exit: "THIS DOOR TO REMAIN
UNLOCKED DURING BUSINESS HOURS"
with 1" high letters on contrasting background
Exit Signage
Exit Illumination
Occupant Load Posted in A Occupancy
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 5
~- - • ~ ~
Permit #BLD02-107
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contracto.r's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 5 of 5
wataman dt t:atz suila;ug
tst Q~ stmt, sum Sot
Pat Tmvasmc~ WA 98368
PLone:(360)379-3208 Fax: (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD02-107R-1 Issued: 11/25/02 Parcel Number: 98980t~66 & -67
Job Address: 884 West Park Avenue Zoning: PUD .Type: V N Occupancy: B
Total Occupant Load: NA Nature of Work: Install Mechanical Svstem (heat pumps) and Ducting
Owner: Jefferson Mental Health Services Contractor: Poulsbo Sheet Metal - POULSSM032C0
GENERAL CONDITIONS APPLY -SEE LAST PAGE
IlVJY1:C;'1'1
MECHANICAL
Exhaust Vent Termination
Heat Pumps & Air Handler
Factory Applied Nameplate
Manufacturer's Operation Instructions Attached
Unit ID'ed for area served
Access and work space for maintenance
Disconnect
Condensate Drain
NREC Temperature Zones
Thermostat Controls
Deadband Control ~ ~~0 ~~
Night Setback with 7 different day types
IViicroprocessor controls
Dampers
Duct Insulation & Sealing
FINAL -see also original building permit #BLD02-107
Mechanical
WSVIAQ
Certification letter from instadder stating compliance with
fresh air requirements
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2