HomeMy WebLinkAboutBLD04-282Waterman & Katz Auilding
181 Quincy Street, Suite 301
Port Townsend, WA 98,368
I'honc: (360) 3Q4-3057 Fax: (360) 385-7G75
CYTY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD04-282 Issued: 11/15/04 Parcel Nnmber: 94$ 303 106
Jab Address: 442 W. Sims Way Zoning: C-II Type: T e III-B s rinklered Occupancy: B (inside M)
Nature of Work: Bank Tenant Im rovement inside Safewa Occupant Load: 400 s . ft. 1/100 = 4 occ.
Owners: American Marine Sank Contractor: Elite Commercial Contracting - ELITE00020CD
GENERAL CONllITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS RE UIRED:
Sign Permit -contact lean Walat @ 3$5-0544
Fire Sprinkler System -for alterations, contact Suzanne Wassmer @ 344-3057
Electrical Permit -contact Labor & Industries @ 350-417-2702
DEFERRED SUBMITTALS:
HVAC, VIAQ and NREC compliance
NREC Lighting compliance, Daylight Zones, Controls, etc.
RF.(l>(TTRF,11 iN~PFC'TI(1N~
APPROVED/DATE
DEMOLITION
Materials from site demolition shall be deposited in Jefferson
County Landfill or to other approved areas off=site that meet all
state and local laws
MECHANICAL.
Source Specific Fans at bathrooms: ducting (with backdraft
dampers), insulation (R-4) and terminus (located three feet from
openings into building)
HVAC, NREC and VIAQ compliance shall be deferred
Submittals
Call 48 hours before you dig for utility line locates
1-800-424-SS55
Page 1 of 1
Permit # BLD04-282
RF.(1TTTRFT) TN~PFf'TT(lNS
APPROVED/DATE
FRAMING
Walls
Bracing
Positive Connections
Fire Blocking
Air Seal (if applicable)
Safety Glazing (if applicable)
DRYWALL/NAILING (if applicable)
Walls
Ceiling
SUSPENDED CEILING
Frame & Supports
(Inspect prior to ceiling the installation)
LIGHTING -deferred submittal
Power Allowance, Daylight Zones, Controls and Switches per
NREC 1513
FINAL
Sign Permit Approval
Fire Department Sign-Off
Electrical Sign-Off
Mechanical
Certification letter from installer stating compliance with fresh
air requirements
Coordinate balancing of system with Safeway
Vapor Barrier Certificate
Barrier-Free Access
Thresholds
Door Clearances
Lever Hardware
Final -Building
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
ptrmi[ # BLD04-282
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fenerng and graveled
construction entrance. Adjacent rights-of--way shall be kept free of dirt & debris. Soils exposed during
construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is
responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
S. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection an your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
schedulin the Buildin De artment's final ins ection.
7. Final Inspections are required prior to occupancy. A Certificate of Occupancy is required far a non-
residential project.
8. All building permits expire if na progress has been made within six months, or if na inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-8U0-424-SSSS
Page 3 of 3
~, ,
CITY OF PORT TOWNSEND
Waterman & Katz Buildng
181 Quincy Street, Suite 301
PaM Townsend, WA 98368
1'honc: (360) 344-3057 Fax: (360) 385-7675
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLD04-282R-~ lssued: 03/04/OS Parcel Number: 948 303 106
Job Address: 442 West Sims Way Zaning: C-II Type: Type III-B surinklered
Occupancy: B (inside M) Occupant Load: 400 sp. ft. (a7 1/100 = 4 occupants
Nature of Work: Mechanical Improvement for Bank Tenant iuside Safeway store
Owner: American Marine Bank Contractor: Aire Pro Inc - ATREPI*032RU
GENERAL CONDITIONS APPLY ~-SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Sign Fermit -contact Jean Walat @ 385-0644
Fire Sprinkler System -- far alterations, call Suzanne Wassmer @ 344-3057
Electrical Permit -contact Labor & Industries @ 360-417-2702
DEFERRED SUBMITTALS:
NREC Lighting compliance, Daylight Zones, Controls, etc. by Hanson Electric
See also original inspection record BLD44-282
RE UIRED INSPECTIONS APPROVED/DATE
MECHANICAL.- Refer to Sheet M1.1 of original plan set
NREC Temperature Zones
Thermostat Controls
Deadband Control
Night Setback with 7 different day setback and shutoff
controls
Dampers @ outside air intakes and exhaust outlets
"Thermostat Interlock
Heat Source Equipment and Controls
Eff ciency
CONTINUED ON NEXT PAGE
Ca1148 hours before you dig for utility line locates
1-800-424-SSSS
Page 1 of 1
Pcnnit # BLD04282R-1
RFOY7IRFD INSPECTIONS
APPROVED/DATE
MECHANICAL Continued
Duct Sealing -duct tape prohibited as a primary sealant
Duct Insulation -- R-7
Supports - @ 10' maximum or per manufacturer's
installation instructions
Diffusers -per IMC 603.17 install per manufacturer's
installation instructions; balancing dampers or other
air supply adjusters shall be provided in the branch
ducts or @ each diffuser
LIGHTING
Lighting power allowance per NREC and Daylight Zones
and Switching as deferred submittal
FINAL
Balancing and Commissioning Report shall be submitted to
the City for review and approval prior to final
GENERAL CONDITIONS
1, Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed an-site and inspected prior
to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled
construction entrance. Adjacent rights-of--way shall be kept free of dirt & debris. Soils exposed during
construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be
permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is
responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca113$5-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
schedulins the Building Department's final inspection.
CaII 48 hours before you dig for utility tine locates
1-800-424-SSSS
Page 2 of 2
Permit. M ALI)04282R-1
7. Final Inspections are required prior to occupancy. A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
Look Up a Contractor, Electrician or Plumber License Detail
Topic Index ~ Contact Info
Page 1 of 2
~_~: Search
„w.., ... Po.,,.,,.,, ~
~ .~~>: Nvrne Safety Clairrtx ~ insurance W+ori~cplace Ri~ht~ Trades l;t Lic+~nsig
Find a Law or Rule Get a Form or Publication
Look Up a Contractor, Electrician or Plumber
<General/Specialty Contractor
'A business registered as a construction contractor with L&I to perform construction work within the scope
of its specialty. A General or Specialty construction Contractor must maintain a surety bond or assignment ~+.
of account and carry general liability insurance.
License Information
License AIREPI*032RU
Licensee Name AIRS PRO INC
Licensee Type CONSTRUCTION CONTRACTOR
UBI 601771753 rif _WorkeCS Comg Premium
51r_atus
Ind.lns. Accoula 95617800
Business Type CORPORATION
Address 1 1112 5 344TH ST 5TE 303
Address 2
City FEDERAL WAY
County KING
State WA
Zip 98003
Phone 2539427028
Status ACTIVE
Specialty 1 AIR HEAT,VENTILATION,EVAPORAT
Specialty 2 OTHER (SPECIFY)
Effective Date 12/31/1997
Expiration Date 3/18/2006
Suspend Date
Separation Date
Parent Company
Previous License AI.REP**040P4
Next License
Associated
License
.. ~,,,,
Business Owner Information
https://fortress.wa.gov/lni/bbip/Detail.aspx?License=AIREPI*032RU 3/4/2005
Waterman & Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: (360) 3643057 Fax: (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca1138S-2294 for Inspection
Permit Number: BLD04-282R-1 Issued: 03/04/OS Parcel Number: 948 303 106
Job Address: 442 W. Sims Wa Zoning: C-II Type: Tyne III-B snrinklered Occupancy: B (inside M)
Nature of Work:Bank Tenant Mechanical Im rovement inside Safewa Occupant Load: 400 sq. ft._
1/100 = 4 occ.
Owners: American Marine Bank Contractor: Air Pro
Scott Reader 253-709-3485
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Sign Permit -contact Jean Walat @ 385-0644
Fire Sprinkler System -for alterations, cantact Suzanne Wassmer @ 344-3057
Electrical Permit -contact Labar & Industries @ 360-417-2702
DEFERRED SUBMITTALS:
NREC Lighting compliance, Daylight Zones, Controls, etc.
RE UIRED INSPECTIONS APPROVED/DATE
See also original Inspectian Record
Ca1148 hours before you dig for utility line locates
1-SOQ-424-SSSS
Page 1 of 1
.. ~ Permit # BLD04282
MECHANICAL -refer to sheet M1.1 of original plan set
NREC Temperature Zones
Temperature Controls
Deadband Control
Night Setback/Seven different day Setback and Shut-off
Controls
Dampers (@ outside air intakes and exhaust outlets)
Thermostat Interlock
Heat Source Equipment and Controls
Efficiency
Duct Sealing -- duct tape prohibited as primary sealant
Duct Insulation - R-7
Supports - @ 10' maximum or per manufacturer's installation
Instructions
Diffusers -per IMC 603.17 install per manufacturer's installation
instructions; balancing dampers or other air supply adjusters
shall be provided in the branch ducts or @ each diffuser
LIGHTING
Lighting Power Allowance per NREC and Daylight Zones and Switching as deferred submittal
MECHANICAL FINAL
Balancing and Caminissioning Reports shall be submitted to the City for review and approval
prior to final
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2
r ~ f
,/J
f ` j ..,.~
r r D ~
(7 ~~. ~ 1 C,' -ti's-.~ ~. C~~,... `,k~ ~ ~ V~ C: ~.
• I ~..
,~_:
~..
"r~ ~ Ct .
-~ r S// C C J
,, .~
...._..
~ ~,,~..~
..
~- ~~ .,,
1
~~ ~,,
._ . ,,
T --
._
~ ~ ~ ~ ~-
.~ ~, ~.,
' ~ C~~. ~ 1
-~ .i
.-.~~~.
... ~~.
~.~.~
~o~QORrrow~~m CITY OF PORT TOWNSEND PUBLIC WORKS &
= ~ DEVELOPMENT SERVICES DEPARTMENT
7' n ,.
~~~WASH~~~ INSPECTION REPORT
PERMIT NUMBER:
---
`,a Address (~,~
~_
... ;\
~~.
((____ L
Contractor ~~~- ~,, ,_. t `'t--~_ ~ ,~: "+!°P`~~•~~:_.c/ ~ ~ ~": - ~..
~.. ~.5
'^^1!y .~
Owner ~F c:...~~-~; ~ ~ ~ r P -^--~ i~ ,. ~~,~,L.. s~ ~ ..~ ~"~.•~?,E.~./~.
----
°~`~ Date of Inspection ~_____ ~ ~ (,~' ~
~.
,~-
- ~,
Worksite or Cell Phone# ~ ~~ ~• ~ ~~ ~ ~~ ~~ ~~~~
-~`
^ Erosion/Sedimentation ^ Plumbing/Top Out U Drywall/Fire Wall _
^ Setbacks/Footings/LIFER ^ Gas Pipe/Pressure Test U Gas/Wood Appliance
^ Foundation Walls ! 1 Propane Tank/Line ^ Manufactured Home Set-up
^ Slab Interior Footing/Insulation ^ Mechanical ~..1 Public Works
^ Groundwork/Plumbing Test LI Framing ^ Other/Consultation ...a~~`
.-~-~- ~
^ Underfloor Framing G Insulation -~, ~ , ,..r`7~~''1 ~ M
^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail -FINAL -""~ ~ ~ ,~^-'.~"~`~ n
~~
If corrections required, re-inspection must be done prior to covering or concealing areas !'~,1,~.
of construction. Additional fees may be assessed for multiple re-inspections.
For Re-inspection, calf Inspection Message Line at (3fi0) 385-2294 prior to 8:00 AM.
1. ~ ..~
NO OCCUPANCY UNTIL FINALIZED B BUILDING AND, IF APPLICABLE, PUBLIC WORKS. r
^ VIOLATION APPROVAL ^ CORRECTION REQUIRED r,,F?~~; ~-
^ APPROVED WITH CORRECTION l.J NEED APPROVED PLANS & PERMIT ON SITE ~; ~ ~
--- ~M~-a~_ _ ~
Approved pla ar~`ci;permit car m
Inspector _ ~ '~~ ~~-
----
_ _ ----
st be on-site and available at time of insp ctiion.
~~
- 4_ ___.... -.__ Date ~ -
~o~Q°RTr°"'a~~y CITY OF PORT TOWNSEND PUBLIG WORKS &
DEVELOPMENT SERVICES DEPARTMENT
~dFWASH~~~~ INSPECTION REPORT
PERMIT NUMBER: ~ ~- ~,~
Address
Contractor
Owner
Date of Inspection
Worksite or Cell Phone#
^ Erosion/Sedimentation
U Setbacks/Footings/LIFER
^ Foundation Walls
V Slab Interior Footing/Insulation
^ Groundwork/Plumbing Test
V Underfloor Framing
^ Shear Wall/Holdowns
^ Plumbing/Top Out ^ Drywall/Fire Wall
^ Gas Pipe/Pressure Test V Gas/Wood Appliance
V Propane Tank/Line U Manufactured Home Set-up
^ Mechanical ~ ~ ! ^ Public Works
U Framing ~ ,~,~ ~~~ Other/Consultation
^ Insulation -•~
CJ Interior Shear/BWP Nail J FINAL
If corrections required, re-inspection must be done prior to covering or concealing areas
of construction. Additional fees may be assessed for multiple re-inspections.
For Re-inspection, call Inspection Message 'eat (360) 385-2294 prior to 8:00 AM.
NO OCCUPANCY UNTIL FINALIZED BY LDING AND, IF APPLICABLE, PUBLIC WORKS.
^ VIOLATION r PPROVAL ^ CORRECTION REQUIRED
^ APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SITE
Approved plar~¢ permCard must be on-site and available at time of inspection.
'r,
~I~' l_ ~ ~-
;~
Cyr ~~. ~~
2
Inspector w ~ _~M _ Date ~. ~--'~ ~
~o~QOArrogh~~z CITY OF PORT TOWNSEND PUBLIC WORKS &
DEVELOPMENT SERVICES DEPARTMENT
'~~fiWASN~~`~~ INSPECTION REPORT
~~ll _
PERMIT NUMBER: _ ~ ~~V~~~~ ~ ~-~~
Address _ t f ~ ICJ ~ f ~~.5' ~~.~~,•/
Contractor ~~ '~~ ~ ~" (t ~ ~
Owner
Date of Inspection
~ v ~ J ~~
J(~~
Worksite or Cell Phone# l «`tj / - L"'--' /
^ Erosion/Sedimentation ^ Plumbingrfop Out :Drywall/Fire Wall P"~ C~. L~~, ~~
^ Setbacks/Footings/LIFER ^ Gas Pipe/Pressure Test ^ Gas/Wood Appliance 1.=~G-~.r~~~ ~
^ Foundation Walls ^ Propane Tank/Line ^ Manufactured Home Set-up `~`'
^ Slab Interior Footing/Insulation a Mechanical a Public Works ~ t ,~
^ Groundwork/Plumbing Test G1 Framing U Other/Consultation
^ Underfloor Framing ^ Insulation ~~~______..
^ Shear Wall/Holdowns ^ lnterior Shear/BWP Nail ^ FINAL
If corrections required, re-inspection must be done prior to covering or concealing areas
of construction. Additional fees may be assessed for multiple re-inspections.
For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM.
NO OCCUPANCY UNTIL FINALIZED BY BUILDING AND, IF APPLICABLE, PUBLIC WORKS.
^ VIOLATION OVAL U CORRECTION REQUIRED
^ APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SITE
Approved pl a d permit card st be on-site and available at time of inspection.
p ~~ ~ _ Date , ~ / ~{ A 6 c
Ins ector