Loading...
HomeMy WebLinkAboutBLD04-183 Waterman and Katz Building 181 Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: (360) 379-3208 Fax: (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDU4~183 Issued: 07/28/04 Parcel Number: 992 300 049 Job Address: 4360 San Juan Ave. Zoning: R-II Type: V-N Occupancy: R~3 Total Occupant Load: 3 Nature of Work: Construct Single-family Dwelling. Owner: Bret Sukert Contractor: Bret Sukert Construction BRETSC*981DF GENERAL CONDITIONS APPLY: See last a e SEPARATE PERMITS REQUIRED: Electrical Permit _ Contact WA State Dept. of Labor & Industries 360-417-2702 RF.(1><T><RF.11 ><N~PF,(~'T><f1NS APPR(~VEn/nATE TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks Footings Forms Reinforcement Interior Footings Porch footings UFER FOUNDATION Stem Wall Forms Reinforcement Anchor Bolts & Washers Post to Foundation Wall Positive Connection Holddowns -per architect's design Vents - 7 Required Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 Building Permit #BLD04183 RF.nIT><RFn ><N~PF(''TT(7NS APPROVED/DATE FLOOR FRAMING NOTE: Engineered BCI floor plan on-site and available to the Inspector at inspection time Girders Joists Blocking Post to Foundation Wall Connection Positive Connections Treated Waod to Concrete Anchor Bolts & Washers Holddowns -per architect's design PLUMBING Rough-In (D-V-T & Clean outs) Water Supply Water Hammer Arrestors Hose Bibbs - backflow protection required Pipe Insulation (R-3) Pressure Reduction Valve if ~ 80 psi Water Heater R-10 under if electric Seismic Restraint - 2 places, Pressure Relief Valve drain to exterior, terminate 6" -24" above ground Licensed Plumbing Contractor's Signature & License Number: Sign here MECHANICAL Source Specific Exhaust Fans @ bathrooms (SOcfm), laundry room, (50 cfm) and kitchen (100 cfm) Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Whale house fan -Laundry Call 48 hours before you dig for utility line locates 1-500-424-5555 Page 2 of 4 Building Permit #BLU04183 RF(IITIRF,n INSPECTIONS APPROVED/DATE FRAMING Prescriptive & designed braced wall panel sheathing & nailing must be inspected prior to cover Fasteners, hangers etc. in contact with treated material must be hot dipped galvanized Flaar -Engineered BCI plan to be on site at inspection Walls Halddowns Shear walls -per architect's design Shear Panel Blocking Roaf -Engineered truss plan to be on site at inspection Attic venting -ridge & eave Posts, beams and headers Windows -escape Windows -safety glazing Window U-factor - 0.40 or better Door U-factor - 0.20 or better Skylight U-factor - 0.58 or better NFRC sticker. must be on windows, doors & skylights at time of inspection Air Seal Fresh Air Intake - window ports Fireblocking Weather Resistive Barrier INSULATION Floor (R-30 ) Walls (R-2I ) Ceiling (R-38, attic; R-30, vault) Baffles Vapor Barrier -paint DRYWALL NAILING Walls Ceiling FINAL Note: prior to final all landscaping, including an irrigation system, must be installed or bonded for per the approved landscaping plan; a fence or hedge of 36" or less in height shall be installed to separate each private open space from the commou open space. See next page Ca1148 hours before you dig for utility line locates 1-800-424-SSSS Page 3 of 4 Building Permit #BI,D04183 arrKu FINAL continued Public Works Sign-off House Numbers -- 5" numbers Plumbing Mechanical/Heating Insulation Certificate Smoke Detectors Stairs, Decks & Landings Final -building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's rerstration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twee -four hours notice is re aired. Public Works a royal must be received rior to schedulin the Buildin De artment's final ins ection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-residential project. $. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Ca1148 hours before you dig far utility line locates 1-800-424-5555 Page 4 of 4 cF poar rod City of Port Townsend ~ tiN~x - - Development Services Department .._ ° Waterman-Katz Building `~ ~`} ~" 181 Quincy Street, Suite 301 A, Port Townsend WA 98368 ~` ~wns~"" (360) 379-3208 FAX (360) 385-7675 CERTIFICATE OF OCCUPANCY Permit Numbers: BLD04-179, BLll04-1$0, BLD04-1$1, BLD04-1$2, BLD04-183 Owner: Bret Sukert Addresses: 4360, 4370, 4380, 4390 San Juan Avenue Location: Fort Townsend, WA 9$36$ Building/Use: Four Single Family Residences (Cottages A-D) and Shared Storage Building The above-referenced building or partian complies with the applicable requirements of the Port Townsend Building Cade (PTMC 16.04), has passed all required inspections and may be used and occupied in the use and manner indicated above. This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not be removed except by the Building Official. Approved: ~~.. W a2~0 j"-"~' Apri128, 2 assurer, Permit Technician Date