HomeMy WebLinkAboutBLD04-183
Waterman and Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: (360) 379-3208 Fax: (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDU4~183 Issued: 07/28/04 Parcel Number: 992 300 049
Job Address: 4360 San Juan Ave. Zoning: R-II Type: V-N Occupancy: R~3
Total Occupant Load: 3 Nature of Work: Construct Single-family Dwelling.
Owner: Bret Sukert Contractor: Bret Sukert Construction BRETSC*981DF
GENERAL CONDITIONS APPLY: See last a e
SEPARATE PERMITS REQUIRED:
Electrical Permit _ Contact WA State Dept. of Labor & Industries 360-417-2702
RF.(1><T><RF.11 ><N~PF,(~'T><f1NS
APPR(~VEn/nATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS
Setbacks
Footings
Forms
Reinforcement
Interior Footings
Porch footings
UFER
FOUNDATION
Stem Wall
Forms
Reinforcement
Anchor Bolts & Washers
Post to Foundation Wall Positive Connection
Holddowns -per architect's design
Vents - 7 Required
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Building Permit #BLD04183
RF.nIT><RFn ><N~PF(''TT(7NS APPROVED/DATE
FLOOR FRAMING
NOTE: Engineered BCI floor plan on-site and
available to the Inspector at inspection time
Girders
Joists
Blocking
Post to Foundation Wall Connection
Positive Connections
Treated Waod to Concrete
Anchor Bolts & Washers
Holddowns -per architect's design
PLUMBING
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrestors
Hose Bibbs - backflow protection required
Pipe Insulation (R-3)
Pressure Reduction Valve if ~ 80 psi
Water Heater
R-10 under if electric
Seismic Restraint - 2 places,
Pressure Relief Valve drain to exterior, terminate
6" -24" above ground
Licensed Plumbing Contractor's Signature &
License Number:
Sign here
MECHANICAL
Source Specific Exhaust Fans @ bathrooms (SOcfm),
laundry room, (50 cfm) and kitchen (100 cfm)
Environmental Air Exhaust ducting (w/ backdraft
dampers), insulation (R-4) and terminus (located 3'
from openings)
Whale house fan -Laundry
Call 48 hours before you dig for utility line locates
1-500-424-5555
Page 2 of 4
Building Permit #BLU04183
RF(IITIRF,n INSPECTIONS APPROVED/DATE
FRAMING
Prescriptive & designed braced wall panel sheathing
& nailing must be inspected prior to cover
Fasteners, hangers etc. in contact with treated material
must be hot dipped galvanized
Flaar -Engineered BCI plan to be on site at inspection
Walls
Halddowns
Shear walls -per architect's design
Shear Panel Blocking
Roaf -Engineered truss plan to be on site at inspection
Attic venting -ridge & eave
Posts, beams and headers
Windows -escape
Windows -safety glazing
Window U-factor - 0.40 or better
Door U-factor - 0.20 or better
Skylight U-factor - 0.58 or better
NFRC sticker. must be on windows, doors & skylights
at time of inspection
Air Seal
Fresh Air Intake - window ports
Fireblocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
Walls (R-2I )
Ceiling (R-38, attic; R-30, vault)
Baffles
Vapor Barrier -paint
DRYWALL NAILING
Walls
Ceiling
FINAL
Note: prior to final all landscaping, including an
irrigation system, must be installed or bonded for per
the approved landscaping plan; a fence or hedge of
36" or less in height shall be installed to separate each
private open space from the commou open space.
See next page
Ca1148 hours before you dig for utility line locates
1-800-424-SSSS
Page 3 of 4
Building Permit #BI,D04183
arrKu
FINAL continued
Public Works Sign-off
House Numbers -- 5" numbers
Plumbing
Mechanical/Heating
Insulation Certificate
Smoke Detectors
Stairs, Decks & Landings
Final -building
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
rerstration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing
and graveled construction entrance (see attached details). Adjacent rights-of way shall be kept free
of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching,
plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc.
once construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twee -four hours notice is re aired. Public Works a royal must be received rior
to schedulin the Buildin De artment's final ins ection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
$. All building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year to
keep your building permit active.
9. Revisions require review and approval prior to making changes in the field. Contact the Building
Department at 379-5086 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig far utility line locates
1-800-424-5555
Page 4 of 4
cF poar rod
City of Port Townsend ~ tiN~x
- - Development Services Department .._ °
Waterman-Katz Building `~ ~`} ~"
181 Quincy Street, Suite 301 A, Port Townsend WA 98368 ~` ~wns~""
(360) 379-3208 FAX (360) 385-7675
CERTIFICATE OF OCCUPANCY
Permit Numbers: BLD04-179, BLll04-1$0, BLD04-1$1, BLD04-1$2, BLD04-183
Owner: Bret Sukert
Addresses: 4360, 4370, 4380, 4390 San Juan Avenue
Location: Fort Townsend, WA 9$36$
Building/Use: Four Single Family Residences (Cottages A-D)
and Shared Storage Building
The above-referenced building or partian complies with the applicable requirements of the Port
Townsend Building Cade (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
Approved:
~~.. W a2~0 j"-"~' Apri128, 2
assurer, Permit Technician Date