HomeMy WebLinkAboutBLD04-121W alerrnan ~ Katz Building
I81 Quincy Street, Suit; 3U1
Por[ Townsend, WA 98368
Phone:(360)379-3208 Fax: (360)385.7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BiI,DQ4-~ 21 Issued: 05/10/04 Parcel Number: 9S9 704 401
Job Address: American Legion Parking Lat (a, Manroe Street Zoning: CIII Type: V-N Occupancy: U-1
Nature of Work: Temporary Structure-]2'x 20' carport-tyue metal building erected for Kiwanis Club
event for 48 hours during the Rhododendron Festival
Owner: Kiwanis Club
Rich Gastfield @ 385-3300
Contractor: Same as owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
REQUIRED INSPECTIONS
FRAMING/FINAL
Framing Inspection maybe done at Final
Inspection if all elements of framing are
visible.
Engineered pre-fabricated metal carport
Positive connection to ground per plans
Jefferson County Health Department will
inspect kitchen during the event
Final -Fire Department (See attached Fire
Department memo dated 5/12/02)
Final -Building Department
U
Ca1148 hours before you dig for utility line locates
1-$00-424-5555
Page 1 of 2
a
Pcrmit # BLD04- 121
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Adjacent rights-of--way shall be kept free of dirt debris. Any soils exposed during construction
shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently
stabilized with seeding, plantings, sodding, etc. once construction is eomplete. Applicant is
responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
S. Re-inspection is required after inspection report corrections are completed.
6. For inspection ca1138S-2294. A minimum of twenty-four hours notice is required.
7. A11 building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year
to keep your building permit active.
$. Revisions require review and approval prior to making changes in the field. Contact the
Building Department at 379-5086 prior to making changes to the approved plans.
9. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-SSSS
Page 2 of 2