Loading...
HomeMy WebLinkAboutBLD04-040Waterman & Katz Building 181 Quincy S[reet, Suite 301 Port Townsend, W A 98368 Phone: (380) 379-37A8 Fu: (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BI.D04-O4OR-I Issued: 04/28/04 Parcel Number: 989 700 611 Job Address: 639 Water Street Zoning: C-III Type: VV=N Occupancy: N/C Total Occupant Load: N/C Location: N.D. Hill Building Nature of Work: Structural upgrades to Parapet Owners: Donna and Christoaher Sudlow Contractor: Olvmuic Masonry Restoration - OLYMPMR044CZ (360)385-5757 GENERAL CONDITIONS APPLY -SEE LAST PAGE NOTE: Any change in exterior paint colors is subject to Historic District Design Review approval PRIOR to beginning any paintwork (application required). If the new exterior paint colors are selected from the City's Historic Paint Palette, please complete an Exterior Paint Registration form available from BCD. Stuctural on-site welding to be performed by WABO Certified welders please submit certifications to BCD for verification prior to welding. REOUiRED INSPECTIONS APPROVED/DATE SEDIMENT CONTROL Sweep Concrete & Paved Surfaces during construction as needed PEDESTRIAN PROTECTION - Install barrier around area of work to prevent pedestrian access. Provide Protection per UBC as required. Inspection required prior to beginning work. MASONRY -see attached engineering 4000 psi grout for regrouting 5 mortar joints @ anchor height full width of face brick MC8 X 18.7 Channel attached to masonry face with 3/4" X 12" threaded rod epoxied into wall @ 18" o.c. Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 1 of 3 PemJ[N HLD04040R-1 REOUiRED INSPECTIONS APPROVED/DATE FRAMING -see attached engineering 2X4 Walls @ 24" o.c. below bracing 1-1/8" X 36"plywood between roof joists attached to roof sheathing w/36 l Od's @ 4" o.c. Angle connection w/2 -angle %z" X 2-1/2" X 3/16" attach to plywood and joist with 6 -''/o" SDS screws into each member MT5 18 straps at roof joists to wall studs Angle braces at sheathing- 2- 4 X 4 X '/4" or 1- SXSXS/16" Angle braces to wall and sheathing connections FINAL Building Number Final -Building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, haldowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is reouired. Public Works auaroval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 3 Perrtdtm BLD00.-040R-I 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval rior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLAN5. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 W atermen & Kalz Building I&l Quincy Streel, Suite 301 Part Townsend, WA 98368 Phone: (360)379-3208 Fax: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: $LD04-O40 Issued: 02/27/04 Parcel Number: 989 700 611 Job Address: 639 Water Street Zoning: C-III Type: VV=N Occupancy: N/C Total Occupant Load: N/C Location: N.D. Hill Building Nature of Work: Exterior reaair/renovation -See attached scone of work. Structural upgrades to be issued as Revision #1 after en2ineerine is received. Owners: Donna and Christopher Sudlow Contractor: Olvmaic Masonry Restoration (360)385-5757 GENERAL CONDITIONS APPLY -SEE LAST PAGE NOTE: Any change in exterior paint colors is subject to Historic District Design Review approval PRIOR to beginning any paintwork (application required). If the new exterior paint colors are selected from the City's Historic Paint Palette, please complete an Exterior Paint Registration form available from BCD. REQUIRED INSPECTIONS APPROVED/DATE SEDIMENT CONTROL Sweep Concrete & Paved Surfaces during construction as needed PEDESTRIAN PROTECTION - Installbarrier around area of work to prevent pedestrian access. Provide Protection per UBC as ;'' j / L. / `~ required. Inspection required prior to beginning . 7 ~~, ' ~ C1- work. L ` MASONRY All masonry repairs per attached scope of work. FINAL Building Number Final -Building Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 2 Pertnit# BLD04-040 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-Four hours notice is required. Public Works aoaroval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-500-424-5555 Page 2 of 2 F ~I,~ './~ ~/ ~~ ~D ~1. °``°p"°""~sF CITY OF PORT TOWNSEND PUBLIC WORKS BUILDING AND COMMUNITY DEVELOPMENT ~°.wAS~~~° INSPECTION REPOR/T' PERMIT NUMBER: ~ ~ ~~ Q'l Ci' ~~ ~ 1 Address Contract Owner Date of Inspection `~ `-~ ~ - ~%~ Worksite or Cell Phone# ~~ ~ ~ ~S ^ Erosion/Sedimentation U Plumbing/Top Out ^ Drywall/Fire Wall ^ Setbacks/Footings/LIFER ^ Gas Pipe/Pressure Test ^ Gas/Wood Appliance ^ Foundation Walls ^ Propane Tank/Line ^ Manufactured Home Set-up ^ Slab Interior Footing/Insulation ^ Mechanical ^ Public Works Groundwork/Plumbing Test ^ Framing Other/Consultation Underfloor Framing ^ Insulation ~~tSVYI l~ ^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail ~NAL If corrections required, re-inspection must be done prior to covering or concealing areas of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZ EI;),BY BUILDING AND, IF APPLICABLE, PUBLIC WORKS. ^ VIOLATION ~~APPROVAL ^ CORRECTION REQUIRED Approved ~I/an„s, and permit card must be on-site and available at time of inspection. Inspector s'~ ' _ _ Date ~' ~ _ ~.