HomeMy WebLinkAboutBLD04-019Waterman & Katz Building
181 Quincy Street, Suite 30l
PoR Townsend, WA 98368
Phone: (360) 379-3208 Fex: (360) 385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO4-O19 Issued: 02/03/04 Parcel Number: 974 700 404
Job Address: 2321 Sims Way Zoning: CC=II Type: VV=N Occupancy: M; accessory B & S-1
Total Occupant Load: No Chance
Nature of Work: TI: Remove non-load bearing walls; new demising walls; accessible restroom
Owner: Westbay Auto Parts Contractor: Little & Little Construction LITTLLCI57CS
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPROVED/DATE
DEMOLITION -see permit #MISO4-001
Materials from construction shall be deposited in approved
areas off-site in accordance with all state and local laws
and ordinances.
MECHANICAL
Bath Fan -minimum 50 cfm
Environmental Air Exhaust ducting (with backdraft
damper), insulation (R-4) and termination (3 feet from
openings into building)
PLUMBING -Barrier-Free Compliance
Drain, Waste & Vent Rough-In
Water Supply
Pipe Insulation - R-3
Hose Bibbs - backflow protection required
Hot Water Heater (if installing new)
Seismic Restraint
PTR Valve drain to exterior
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
• • Permit #BLD04-019
RF,OUIRED INSPECTIONS APPROVED/DATE
FRAMING
Walls
Beam
Beam Pockets
Curtain Wall
Positive Connections
Lever Hardware required on doors
Thresholds-maximum %z"
Fireblocking
Maneuvering Clearances @ doors (for new installations)
DRYWALL
Walls
Curtain Wall
Ceiling
INSULATION
Fill exposed exterior wall cavities
LIGHTING
Prescriptive -replace less than 60% of fixtures
FINAL
Property address posted -min. S"numbers of contrasting
color posted near the main entrance of the building and
~
visible from the street per City ordinance. !
';
Electrical Sign-off (L & I) ~ ~`f
: ~'~~~
Fire Department Sign-Off ~
.
~!
Barrier Free Access ~
"'
Thresholds u
Door Clearances ~?''
Lever Hazdware t^. ~,
Final -Plumbing; barrier free required
Final -Mechanical ~? . ~
~
Final -Building %" ~
~ ~
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 3
• • PermilfiBLD04-019
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduline the Buildine Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
City of Port Townsend
Building & Community Development
Waterman & Katz Building
181 Quincy Street
Port Townsend, WA 98368
(360)379-3208 Fax: (360)385-7576
Permit Number:
Owner(s):
Address:
Building (or portion):
Use(s) permitted:
CERTIFICATE OF OCCUPANCY
BLD04-019
West Bay Auto
2321 Sims Way
Port Townsend, WA 98368
Retail Auto Parts Business
M, Accessory B and S-1
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and maybe used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
Approved: ~~rl~'~j "~'"`r`~. Vl/~4~ 3 2 S%a
Suzanne assurer, Permit Technician Date