Loading...
HomeMy WebLinkAboutAdams Street Addendum to the Geologic Hazard Assessment for Jefferson Street - 2019.05.17Stratum Group File: 4.1.19 1 STRATUM GROUP P.O. Box 2546 Bellingham, WA 98227 May 17, 2019 Brandon Maxwell and Samantha Harper City of Port Townsend- Public Works Department 250 Madison Street Port Townsend, WA 98368 Re: Addendum to Geology Hazard Assessment Jefferson Street – Taylor Street to Washington Street TIB Project No. P-W-151(P07)-1 Dear Mr. Maxwell and Ms. Harper: Stratum Group previously completed a geologic hazard assessment for two proposed electric utility vaults as part of the Jefferson Street - Taylor to Washington Street Transportation Investment Board (TIB) project. It is our understanding that the proposed locations for the vaults have changed. The new location for both of the vaults is within the Adams Street right-of-way near the base of a gentle cut slope below the Adams Street trail that links Jefferson Street to Washington Street. This area was included as part of our previous geologic hazard assessment (Stratum Group 4.11.18). Figure 1. Proposed location for two electric utility vaults. Stratum Group File: 4.1.19 2 May 17, 2019 Jefferson Street – Taylor Street to Washington Street TIB Project No. P-W-151(P07)-1 Addendum to Geologic Hazard Assessment We visited the new vault location on April 4, 2019 with Public Works staff and determined that it is not located within a geologically hazardous area. As described in our previous report (Stratum Group 4.11.18), the gentle slopes below the Adams Street trail do not meet the criteria for a geologic hazard area per PTMC 19.05 and are not at risk of landslides or erosion. Furthermore, the proposed electric utility vaults will not increase the risk of landslides or erosion on or off the site as long as the recommendations of our previous report (Stratum Group 4.11.18) are followed. Several portions of the slope below Jefferson Street do meet the criteria for geologically hazardous areas per PTMC 19.05.100B5 but they are located over 50 feet from the new proposed vault location. The slopes below Jefferson Street are characterized in detail in our previous report (Stratum Group 4.11.18) and are not at risk of landslides or erosion. Stratum Group appreciates the opportunity to be of service to you. Should you have any questions regarding this assessment please contact our office at (360) 714-9409. Sincerely yours, Stratum Group Dan McShane, L.E.G., M.Sc. Geoff Malick, G.I.T. M.Sc. Licensed Engineering Geologist Geologist-in-Training