Loading...
HomeMy WebLinkAboutBLD07-201City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-s0es BUILDINGPERMIT Project Informution Permit Type Residential - Addition/Remodel Site Address 739 TAYLOR ST Project Description Addition of second floor bath and dormer Permit # Project Name Parcel # BLD07-201 ADD BATHIDORMER 988800106 Names Associated with this Project Type Name Applicant Saul Bryan N Owner Saul Bryan N Contact Phone # License Type License # Exp Date Fee Informution Project Valuation Building Permit Fee PRF-REVISION Plan Review Fee Technology Fee for Building Permit State Building Code Council Fee Record Retention Fee for Building Permit Total Fees Project Details Entered Bid Valuation Units: Bedrooms: Bathrooms Heat Type: Construction Type: $8,000.00 t53.25 135.05 99.61 5.00 4.50 7.75 8,000 DoL[ $ 40s.16 Occupancy Type: n 'D /vl(/tl-:v /x pt?ro ,NE€'b To /(ro ( ToB F/Al Conditions 10. Property corner survey pins must be located at time of foooting inspection to veri$z setbacks. *;Y i) i1,"i,,il' Gvo t j.L{ pr F*, I d-Ll-ry *"-'-,F-'_'- c a,, 3 s s _;;:; :; {ffx:: ;?:::,:{;i ^ p.. ti o,, Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certifu that the information provided as a part of the application for this permit is true and accurate to the best of my knowleage. t furttrer certiff that I am the owner ofthe property or authorized agent ofthe owner. DateSignature Print Name Datelssued: l0/16/2007 Issued Byl FRONTDESK Date Expires: 06/17 /2014 0( I BIJILDING PERMIT City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-s09s Proiect Information Permit Type Residential - Addition/Remodel Site Address 739 TAYLOR ST Proiect Description Addition of second floor bath and dormer Permit # Project Name Parcel # BLD07-201 9888001 06 Names Associated with this Project Type Name Applicant Saul Bryan N Owner Saul Bryan N Contact Phone # License Type License # Exp Date Fee Information Proiect Details Entered Bid Valuation 8,000 DoL[ Project Valuation Plan Review Fee Building Permit Fee State Building Code Council Fee Technology Fee for Building Permit Record Retention Fee for Building Permit s8,000.00 99.61 t53.25 4.50 5.00 1.15 Total Fees $270.1I Conditions 10. Property comer suruey pins must be located at time of foooting inspection to verify setbacks *** SEE ATTACHED CONDITIONS *X* Call 385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this pernrit shall not be construed as approval 1o violate any provisions of the PTMC or other lau,s or regulations. I certify that the infonralion provided as a part of the application for this permit is true and accurate to the bcsl of my knorvledge. I further certify that J arn the own Print Name Datelssued: l0ll612007 lssued B1': FRONTDESK er ol the OT agent ofthe owner CO N S T R U C T I O N PR O G R E S S RE C O R I ) CI T Y OF PO R T TO W N S E N D De v e l o p m e n t Se r v i c e s De p a r t m e n t 25 0 Ma d i s o n St r e e t . Su i t e 3. Po r t To w n s e n d . WA 98 3 6 8 PO S T TH I S CA R D IN A SA F E , CO N S P I C U O U S LO C A T I O N . PL E A S E DO NO T RE M O V E TH I S NO T ] C E UN T I L AL L RE Q U I R E D IN S P E C T I O N S AR E MA D E AN D SI G N E D OFF BY TH E AP P R O P R I A T E AU T H O R I W AN D TH E BU I L D I N G IS AP P R O V E D FO R OC C U P A N C Y , ST A M P E D AP P R O V E D PL A N S MU S T BE AV A I L A B L E ON TH E JO B S I T E . PA R C E L NO . 98 8 8 0 0 1 06 PE R M I T NO BL D 0 7 - 2 0 1 IS S U E D DA T E 10 t 1 6 t 2 0 4 7 P( P I R A T I O N DA T E AD D R E S S 73 9 TA Y L O R ST CO N S T R U C T I O N TY P E OC C U P A N T LOAD OW N E R SA U L BR Y A N N PR O J E C T DE S C R I P T I O N Ad d i t i o n of se c o n d fl o o r ba t h an d do r m e r CO N T R A C T O R LE N D E R IN S P E C T I O N IN S P DA T E COMMENTS0411312008 IN S P E C T I O N IN S P DA T E CO M M E N T S ,N S p E c , , o N * = n r = r 1 3 f i i8 Y ? T # f f E5 ? l 3 t ' # l i l T ' f :' d f ii - ' D A y r N S p E c ' o N SE T B A C K S SU R V E Y PI N S FR A M I N G PL U M B I N G ME C H A N I C A L SH E A R WA L L IN S U L A T I O N GW B SM O K E DE T E C T O R S FI N A L BU I L D I N G \ITY OF PORT TOWNSEND )PERMIT ACTIVITY LOG PERMIT # BI AD7.ol SCOPE OF WORK: DATE RECETVED 9 - pr -a7 DATE ACTION INITIALSq-2D-D7 ENTERED INTO CHET CA - to Planni ng - No evidence qHECKED FOR COMPLETENESSt) l,r'l ea -SL)t S /v rA Jla t (gc"d aQlfi /^,'l '*t*, QichxJ 6el"4- OK" c"-/ {47 iri K'1n r o qt'n a t g! S O 3F T L lZ -tz- r,r I L o >F l r- tt-tz lJ*vffi +F I )') City of Port Townsend Development Services Department 250 Madison Street, Suite 3 Port Townsend WA 98368 (360) 344-30s7 FAX (360) 344_461e December 12,20ll Mr. Bryan Saul 739 Taylor Street Port Townsend, WA 98368 SUBJECT: BLD07-201 Mr. Saul, According to our records, your building permit (BLD07-201 for second floor bath and dormer addition) has been expired since January l, 2009. The office copy of the approved construction plans for this project will be disposed of 30 days after the date of this notice. Be aware that our records will show that this permit did not receive a final inspection. Please contact the Development services Department with any questions concerning your permit or this notice. I can be reached at 360-j79-505g. Regards, tuAffi- Fred Slota, CBO Building Official 3 1 +. +. )o I ( 6. )t\ aa % 1S TA X 5 (N 7 ) 2 - .o I I 5 +. or o j a b- 03 o Cify of Port Townsend Development Services 250 Madison St. , Suite 3, Port Townsend, WA 98368 (360) 379-3208 FAX (360) 344-4619 November 6, 2008 Mr. Bryan Saul 739 Taylor St. Port Townsend, WA 98368 SUBJECT: Building Permit Extension - BLD07-201 Dear Mr. Saul I received your note indicating that you would be beginning this project on the first of this month. The permit was issued on 10/1612007 and could be considered to be expired. However due to the limited nature of the project and your funding difficulties an extension of time for this permit does seem in order. Please arrange to have a valid inspection prior to the end of the year to maintain the permit. Sincerely, Development Seruices A NATIONAL MAIN STREET COMMUNITY WASHINGTON'S HISTORIC VICTORIAN SEAPORT ,-)tolasloe ) f 't ,,"*ord. 'b be11tw ra6hz-'g Ru P'B*,to o9'ao1 d(g,nnt1g A/ov a o?0o8. aie d"Gy b eke pqJ-.t' Nqs duu b $r,'d,q -t sk 6 - ocT 2 I 2008 t-nlEI \f SENDNTO\I!PORlOFCITY DSD Parcel Details Page 2 of 2 http ://www. co j efferson.wa.us/assessors/parcel/parcel detai l. asp 1012812008 49 t h st L(P O RT ldentified Parks, Sr ldentified Licensed Other Potential lde 1000 Foot Buffer Other Potential Bu'Business Park Manufacturing Zon Commercial Zoninri-i ,.i----]tr i fl |J \ I i l i I' i I fhrc]uul { r*u( d /i L" tu rtactlv^ft +(;e rurlany' perr^it as oq3,"? .p[o^rr-d. I Cd",r,lo n*[*il @ 3/6- q44S vltv\tl fW,+- /V t t iw'yorl*-rl kuln (h* d^rL'b C-LIP** in Vu>L t'\/- rn/,r.-l n^5t- bL C-hL {e fta4t{wl< Av (* *\h", r\L fv&<v Pe7 fuu'4') lnla.n t(u {*, tS Development Services Residential Building Permit Application ) Applications accepted by mail must include a check for initial plan review fee of $150) See the "Residential Building Permit Application Requirements" for details on plan submittal requirements. Prooertv Owner: Name: '-RRrt)v AJ., SAtIL Ad City/SUZip Phone:t Email a Total Lot Coverage (Building Footprint) Square feet: b&SCt %ff lmpervious Square feet: Surface: xla Any known wetlands on the property? Y 6D Any steep slopes (>15%l? Y69 I hereby certify that the information provided is correct, that I am either tfe owner or authorized to act on behalf of the owner and that all activities associated with this permit will be in accordAncd wrln [$ta$i!--irws and the Port Townsend Municipal Code. Print Name: Contractor Name:OAf,trER Address: City/SUZip: Phone: Em State License #:_Exp:_ City Business License #: Project Address: \Sq'rAvtf,A -fl Parcel u qB gg oor-ot, Legal Description (or Tax #): Ad d itio n : PJU ml,.ecls Oir.cjr nert'liru+{&O Block: ,t Lot(s):I Proiect Descriotion: .Ser.,n"rt {/,o- Rxrt.r t()ourp Atlin.t,n,n Lender lnformation: Lender information must be provided for projects over $5,000 in valuation per RCW 19.27.O95. Name Project Valuation:8oo6 Co ntacURepresentative : Name: RflJrruu N, SR tle Address: 1sc4 .rAYLoS sr PhA lv-lvar,e @ olrturovs" Agt City/SUZip: Phone Email: Building lnformation (square feet) 1't floor 2nd floor 3'd floor lLlsc.^ Basement: 75O N/fi , N/*/4..3r" Garage: Deck(s) Ca Manufactured Home n New I Addition ! Porch(es) ls it finished? Yes (No) Other: ADU ! Remodel/Repair tt/n { Signature:Date oY /;zo lov RESIDENTIAL BUILDING PERMIT APPLICATION CHECKLIST This checklist is for new dwellings, additions, remodels, and garages. The purpose rs fo show what you intend to build, where it will be located on your lot, and how it witt be constructed. I Residential permit application. I Washington State Energy & Ventilation Code forms I T.wo (2) sets of plans with North arrow and scaled, no smaller than Ta" = l foot: X A site plan showing: 1. Legal description and parcel number (or tax number), 2. Property lines and dimensions 3. Setbacks from all sides of the proposed structure to the property lines in accordance with a pinned boundary line survey 4. On-site parking and driveway with dimensions 5. Street names and any easements or vacations 6. Location and diameter of existing trees7. Utility lines B. lf applicable, existing or proposed septic system location 9- Delineated critical areas boundaries and buffers I Foundation plan: 1. Footings and foundation walls 2. Post and beam sizes and spans 3. Floor joist size and layout 4. Holdowns 5. Foundation venting I Floor plan: 1. Room use and dimensions 2. Braced wall panel locations 3. Smoke detector locations 4. Attic access 5. Plumbing and mechanical fixtures 6. Occupancy separation between dwelling and garage (if applicable) 7 - Window, skylight, and door locations, including escape windows and safety glazing I Wallsection: 1. Footing size, reinforcement, depth below grade 2. Foundation wall, height, width, reinforcement, anchor bolts, and washers3. Floor joist size and spacing 4. Wallstud size and spacing 5. Header size and spans 6. Wall sheathing, weather resistant barrier, and siding material 7. Sheet rock and insulation 8. Rafters, ceiling joists, trusses, with blocking and positive connections 9. Ceiling height 10.Roof sheathing, roofing material, roof pitch, attic ventilation ll Exterior elevations (all four) with existing slope of the land in relation to all proposed structures I lf architecturally designed, one set of plans must have an original signature -J lf engineered, one set of plans must have one original signature I For new dwelling construction, Street & Utility or Minor lmprovement application Page 1 of2 Suzanne Wassmer From: Richard Berg [richard@richardbergarchitects.com] Sent: Tuesday, October 02,2007 6:06 PM To: Suzanne Wassmer Subject: Re: Dormer for the Sauls Hi Suzanne, The site plan that was turned in with the Saul's plans is accurate. The wall of the house where the dormer is located is 17' from the lot line between Lots 6 and 8. This is measured from a survey pin at the far side of our property, Lot 6, which is 55' wide. We would have no problem allowing access across our property to the pin for the inspector. I doubt that Joann and Bryan have had their lot surveyed. Richard Richard Berg, Principal Architect Richard Berg Archit,ects, PC 7i-9 Taylor Street Port Townsend, WA 98368 360-379-8090 Suzanne Wassmer wrote Hi Richard, I'm reviewing the plans for zoning setbacks. Our ArcReader program isn't entir If so, may I get a copy to show that the dormer is not in the 5' slde setback? Thank you, Suzanne Suzanne Wassmer Land Use DevelopmenE Specialist City of Port Townsend 250 Madison Street, Suite 3 Port Townsend, WA 98368 Phone: 360) Ses-0644 Fax: (360) 344-461,9 r01312007 Page2 of2 r013t2007 2006 WASHINGTON STATE ENERGY CODE City of Port Townsend Development Services l)epartment 250 Madison Street, Suite 3, Port Townsend WA 983,68 (360) 379-5095 Fax (360) 344-461,9 Washington State Energy Code 2006 Edition Climate Zone 1 - Type R-3 and R-4 Changes for Single Family and Duplex Construction The following is a list of code changes that will effect construction of single family and duplex homes in Climate Zone 1. This is not a comprehensive list of changes. To see all the changes, download a new copy of the code and look for a vertical bar in the margin indicating a change in the code. Building Envelope: Prescriptive Options Table 6-1. Option l, the U-factor for windows changed to U-.032. Glazing is limited to 10% of floor area. Option ll, the U-factor for windows changed to U-.035.. Option lV, the U-factor for windows changed to U-.035. There may be an increased use of window U-factor averaging when using the prescriptive method. Applicants may show compliance by providing area weighted average U-factor for all of the windows. With a more stringent standard the use of averaging may increase. The applicant must submit a detailed window schedule demonstrating compliance. Component Performance Table 5-1. The target window U-factor changed to U-.035. The target wall U-factor changed to U-.057. Doors: 602.6 Exterior Doors. One unregulated door up to 24 square feet is still allowed.. Glazed doors are considered to be windows.. All opaque doors must meet the door U-factor requiremenl. ln the past, any door could be called a window when included in the glazing percentage. Now, when using the prescriptive options, opaque doors must meet the U-0.20 requirement. An insulated fiberglass or thermally broken steel door will usually meet the U-factor requirement. Single Rafter Joist: Table 6-1, footnote 3 Table 5-1, footnote 3r lf there is room in the joist for R-3B insulation, R-38 is required. This applies to allsingle rafter joist 13" or greater in depth.. R-30 single rater joist now limited to 500 square feet of roof area. Additional rafter area must use R-38 insulation, The following table shows typical insulation requirements for single rafter joist, lf the table notes R-38, then R-38 is required. Footnote 3, Table 6-1 or 6-2 Prescriptive Rafter lnsulation Based on Fiberglass Batts Nominal Actual Max depth with 1 " ventilation First 5OO SF Over 5OO SF R-value R-value 2X10 91t4"B 114"R-30 HD2 Note 1 2X12 11 114"10 114"R-30 R-38 HD2 2X14 13114"131t4"R-38 R-38 l-Joist 9112"B 112"R-30 HD2 Note 1 l-Joist 117t8"10 7t8"R-30 R-38 HD2 l-Joist 14"13"R-38 R-38 l-Joist 16"15"R-38 R-38 Note 1 HD2 Upsize joist or provide an alternative method meeting U-.027 Refers high densily fiberglass batt or equivalent. A take off noling rafter area will be required. ldentical rules are included in 5-1. They will be incorporated into the UA trade off spreadsheet. 502 -4 -4 Recessed Lighting Fixtures Must now be tested for air leakage using ASTM E2B3 A gasket or caulking must seal the fixture to the drywall Other options for fixture air sealing, including field inspection and a sealed box have been deleted. This has been an option in Washington since 1991. California mandated testing for air tight can lights two years ago. Since tl'ren, every major manufacturer has come on board. The fixtures are readily available. Look for the label in the can. lf the can is not labeled, it does not comply. 505.3 Outdoor Lighting: . Requires high efficiency lighting or controls for all porch lighting. High Efficiency Luminaire is defined in Chapter 2. Typically requires a pin based compact fluorescent fixture ' As an exception to the High Efficiency Luminaire, a motion sensor + photo daylight control may be used. 505.4 Linear Fluorescent Fixtures: This rule applies to typical fluorescent tube fixtures Linear fluorescent fixtures must be fitted with T-8 (1" diameter) or smaller lamps (but not T 10 orT-12lamps) a a a O ) Ghapter 9 Prescriptive Space Heating System Sizing Deleted. See IRG Ml401.3.. 503.2.2 Size limited to 150% of heating load Replaced by IRC Section M1401.3. Heating and cooling equipment shall be sized based on building loads calculated in accordance with Air Conditioning Contraclors of America Manual J or other approved heating and cooling calculation methodologies. Manual J is a heating and cooling heat load calculation method. This method takes some training. See their web site for details. httn://www. acca .orq/tech/manualii WSU has developed a spread sheet for WSEC Chapter 5 code qualification. We call this the CPworksheet. This spread sheet will also provide a simple heating system size calculalion that is roughly equivalent to manual J. Limit the use of this spread sheet to electric resistance or combustion equipment sizing. Do not use this spread sheet to size heat pumps or air conditioners. This spread sheet is available on our web site. Washington State University Extension Energy Program Energy Gode Support Email: enersvcode@energy.wsu.edu Phone: 360 956-2042 Gary Nordeen Mike McSorley Chuck Murray Residential Energy Code Support. Energy and Ventilation Code Text. ResidentialComponentPerformanceWorksheets. ResidentialBuilders Field Guide http ://www.energv.ws u. ed ulcode/code s u pport.cf m For Non residential energy code support, Visit the NEEG web site. http :lAruww.neec.neUresou rces/resou rces. htm I a Option Glazino Areatol % of Floor Glazinq U-Factor Door s U-Factor Ceilin92 Vaulted Ceiling3 Wall12 Above Grade Wall. inta Below Grade Wall. .4EXI Below Grade Floor5 Slab6 on GradeVerticalOverheadl 1Oo/"0.32 0.58 0,20 R-38 R-30 R15 R-15 R-10 R-30 R-10 ll,*15%0.35 0,58 o.20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 Iil.25% Group R-1 and R-2 Occupanci es Onlv 0.40 0.58 o.20 R-38 / U=0.03'l R-30 / U=0.034 R-21t U=0.057 R-15 R-10 R-30 / U=0.02I R-10 IV Unlimited Group R-3 and R-4 Occupanci es Only 0.35 0.58 o-20 R.38 R-30 R-21 R-21 R-10 R-30 R-'10 V Unlimited Group R-1 and R-2 Occupanci es Onlv 0.35 0-58 4.20 R.3B / U=0.031 R-30 / U=0.034 R-2'l I U=0.057 R-15 R-10 R-30 / U=0.02I R-10 TABLE 6.1 PRESCRIPTIVE REQUIREMENTSOJ FOR GROUP R OCCUPANCY CLIMATE ZONE 1 " Reference Case 0. Nominal R-values are for wood frame assemblies only o5 assemblies built in accordance with Section 601.1. l. Minimum requirements for each option lised. For example. if a proposed design has a glazing ratio 1o the conditioned floor area of 13oh, it shall comply with all of the requirements of the l5%o glazing option (or higher). Proposed designs which carmot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3- 'Adv'denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than I 2 inches and (b) there is a minimum 1-inch vented airspace above the insulation. Other single rafter'or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet ofceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10, or on the interior to the same level as walls above grade. Exterior insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to themanufacturer's specifications. See Section 602.2. 5. Floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturer's specifications. See Section 602.4. 7. lnt. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation, 8. This wall insulation requirement denotes R-l9 wall cavity insulation plus R-5 foam sheathing. 9. Doors, including all fire doors, shall be assigned default U-factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value. Overhead glazing with U-factor of U-0.40 or less is not included in glazing area Iimitations. 11. OverheadglazingshallhaveU-factorsdeterminedinaccordancewithNFRCl00orasspecifiedinSection502-1 .5. 12. Log and solid timber walls with a minimum average thickress of 3-5" are exempt fiom this insulation requiremenl. Receipt Number:ffi BLD07-201 BLD07-201 BLD07-201 BLD07-201 BLD07-201 988800106 988800106 988800106 988800106 988800106 Plan Review Fee Technology Fee for Building Perm it State Building Gode CouncilFee Building Perm it Fee Record Retention Fee for Building P $99.61 $5.00 $4.50 $153.25 $7.75 Total $99.61 $5.00 $4.50 $153,25 $7.75 $0.00 $0.00 $0.00 $o.oo $0.00 $zzo.r t CHECK 1241 $ 270.11 Total $270.11 genprntrreceipts Page 1 of 1 1 Receipt Number:i .,, r.ri,ii I i i r, t-}1 )t:t Ii..1;i,'i : t.:iia,::.'ii:).)!;:tj |r;.l,jl1iy,1,'1 ,::1;1,,t.r1;1i; j1.'';,r,vr.11/f 1,r.or I I t)l:iill r; illilll I :;1 I r'l,j1ir lir ,ii),ir,,ji,,i.1 ir1 :: l.\:,r i..j L I,.j; i ,r"lit;"tIi:,, r:il.:: ',,,: ,rli j'i i,i.., i'r.t:ii,l r, i,,1ii i.t i,I i r r,r.il BLD07-201 988800106 PRF-REV|S|ON $135.05 $135.05 total: $1OSOS $0.00 CHECK 3069 $ 135.05 Total:$135.05 Notes: 07-0840 07.0840 07-0840 07-0840 07-0840 09120t2007 0912012007 09t24t2007 0912012007 a912012007 Building Permit Fee Plan Review Fee Record Retention Fee for Building Permit State Building Code Council Fee Technology Fee for Building Permit $153.25 $9e.61 $7.75 $4.50 $5.00 BLD07-20r BLD07-201 BLD07-201 BLDo7-201 BLDo7-201 ,./.,rli rf(,1!irrl ii)J:!.1Ixl,iairl ifi 1, j:i fi r 1 1;si1,1, , ,,.,, ,a);!l i :' l, t,'|r,i t,'l tt (, i' ) :\,r,,: it'it l. l it'ii : " | 1 i., ;,,1:,:1,',t 1 i, r'.t i )t: t: til, t il l (J) r ,r.r, l.rli)1..1 :i:r,i rli'ji iir):!i:l"'1,rli"li, ! rl,, i;l i.l: genpmtneceipts Page '1 of 1 @ RIoHARD BER6 ARcHffEcrg,2001 A REVODEL FOR JOAI\I\ AI{P ERYAI\ 3AUL ciiy 13q TAYLCR STREET POR.T TOANSENP v\A qbSbb PARcEL # qbbboolcb PROJEOT PES6RIPTION, aECOND TLOOR BATH ANP DORMER ADDITION, NO CHAN6E9 TO IMFERVIOU' SURFACE OR LOT COVERAOE. THIg PROJEoT gHALL COMPLY IAITH THE FOLLOAINe CODE1' 200b LR.c.,200b ytgEc,200b vlAa PLUMMER'g ADPITION 9LK I LOT b R-lLzoN 5665 t l?ic!-ll.F'_1 C. 1* I I r' '-r' # F t+i.*riil'i I i I itT.fr i:: *ilb ,/att- /^J frKrsWutQ /S€bp{,_c, rr?\ 4LlA FHU{ :f|oo AAE IQE \ gHEET INPEX I, PROJECT INFORMATION,gITE PLAN AND gHEET INDEX 2. PRO?O5ED aECOND FLOOR PLAN 3. PRO?O^ED ROOFINo PLAN 4. gECTIONS 5. ELEVATIONS NOTE5 TO ONNERS, CONTRAoTORS ANP BUILDINE OFFICIALS' I, THESE PLANg ARE INTENDED 10 CONTAIN ALL INFORMATION REdUIRED TO DEMONgTRATE COMPLIANoE I,,IITH APPLIOABLE BUILDINO AND ZONINO CODE1, IN CA^E OF ANY INFORMATION THAT APPEARs TO tsE LA6KINE, PLEASE CONTACT THE AR6HITE6T IMMEDIATELY. 2, THEsE PLANS cONTAIN THE MAJORITY OF THE INFORMATION REOUIRED TO EUILD THE 9TRUCTURE 5HO'I'{N ON THE PLAN5, HOI^{EVER, IT 19 NOT PO11IBLE TO ANTIoIPATE EVERY PIECE OF INFORMATION NEEDED FOR CON'IruCTON. THE ARCHIIECTS HAVE MADE A OOOD FAITH EFFORT TO gTRIKE A REAgONABLE BALANCE BETI,'{EEN PROVI9ION OF INFORMATION AND COST OF THE PLANg, THE PLANg NILL INEVITABLY cONTAIN MINOR PI9CREPAN6IE9 AND AREA5 LACKINo IN 9PE6IFIC INFORMATION. DURINO THE COURSE OF cONSTRUCTION, A5 THEgE AREAS EMER6E, THEY hIILL REOUIRE ATTENTION AND RESOLUTION. THE BEgT REgOLUTION OF I95UE9 OF 1HI3 TYPE 19 MOgT OFTEN ACHIEVED THROUEH A JorNr DEctstoNMAKrNa pROcEse rNffi&.Sr@ffir* ? Q oNNERg, AR6HITE6T AND 6oNTRAqoE$). oxr, o4/11/o1 gCALE,l/4" = l''O I f UPTOAN PROJE6T 5l1E t Fermit Byr TCIWNSEND 96ALE' NT9 () 5 o{\s$(o i-j ,$nx$ u sHs$ 3 PsBt* 9YEF EFxT$ afL (J-)F\)tuF =\)M \DvtLtco Aw =\) a. zc>< ll-- u_ll $etljl -__n il-- ILU [U - xj_jtz.T{tn ___-t ^al t-)*z F-j {[- c.n-L J 1',-b' \ EXI9TIN6 RESIDEN6E --t NE}^,IDORMER o -tro I lfi oIbc.l ,-o| llo'-o' V' ,s {. to LINCOLN gTREET c- ) r) n r)111"7 \/,- r (- \J t-vlil LINcOLN gTREET ALLEY EXI9TINA PARKIN6 9PACE VJ TIlA6 Ftulu E(') MoJ F o _lrf)M\ a96ALE' I"20' a\srosj\rin<v.<qn JZ. KHl- z. H6r-F FvotL l { s.r)z Mm Dz zz {c voIL tu\)ztuA6tuv OF 5 \) ' t-o t-r g 10 [ A I ( ts iO l{ _ t> {r l I iN i lr o iF l7 b \- > i/l' -F- l i r- L -{ l AJ I b'5 J1 rZ , lr r ,< Ir te l I l( > er r+ IJ ln G rg i_ , \ J f+ t f l$ l $ z.a)c\-3 z rn er o z {=q o g ul >c l u ) o- < 3 c! - o P 5! D n dF F -o o F $i l x 3q S qf ; F +F € -n -H ^v c\7l -1 1 b. > 8F 9t n (F -< n9 br n 'r = F L 7 7.:s (h z -n A rn L cr o z -l z q o c (F t- t-6 z z rn T- r-=-- t - ur I rT t z c\c\o rc ct z c\ rn l*X lt n t{tz o l>t>It - t- n o ci \$o z 'l I x o $o s o (' . r -n rn t-f' C\o n z rn ^|E r t-L)1-o c\o 3 -t r r t l\ )o o $ n cr s.o !- )o \' | \-/ =r :f . c) s1 z Xz . Ui r In {. >Zs a) t T- n z rn rn r t- tc l t>t{ l- r z o r m q cr o c z. -{ rn ^€ (!nt r o J tH $T oE uo u o &c\-n U ut rn A ql fr c\ I {rn c\{(' r N o o J ) ( b> < x ro 9 * Y6 $ F$ ; X- o t r *5 # oj =o 'r n -r &F P9 nl $ t:z. rn o -n n o o -n rn rn ul m r o I -o t-=rn o -i l c\m t-z o ul o rn i -o rn X (t r -{z o x z m m r J*{-o rn X (t r -{=Ct Cr =i -l l :g F rg /q @ cC &as .9 t rI l l' r t l) tr t r Fi r - r : H$Fg u{ -O 6J RI o H A R P BE R 6 AR C H I T E C T S , ?, C ll q TA Y L O R gl R E E T PO R T TO t $ r S E t O , M q b * D fl + o t E , (w ) 3 1 q - h a 4 0 Fr x , F6 d f l q - A 9 2 4 ri c h a d Q r i c h w & e r E r c h i l e c l s . c a n PR . C P E s E D SE E E N D TL E E R . PI A N RE S I D E N c E FO R . AN N AN P BR Y A N 5A U Eq TA Y L O R 5T . PO R T TO n N 9 E N p , r. l A qb 3 b b (' |-rn rn { It " . t ) o -n \t l (t l -nr m {(t r 56 6 s I ))@ RrcHARp BER6 AR6HTTE6 ,. I L)\o\o tl) NOTE' REFER TO DETAILg I AND 2 afrEET 4 FOR 6ONNE6TOR 6ALL OUTg, 8Lg{t?- zo" 2001 & l;.t (: t* trJl*(.., (rd DAIE, oq/n/ol gc/i-je'l/4'= |'O s$$ -E$xE EeH$$ 5Hsfi* E FHr$ \)fL trtF\)luF =\) D/. \DwItlco Av. :r\) w I' it il II \ v I 4XI2 6ONTINUOU9 HEADER EXI9TIN6 RAF1ER9 2'X4'NET.NEI E 24" o.c.,x?. 4XIO DORMER RID6E FEAM (3) 2XIOMAIN ROOF * U, * Jr*, I PORMER 16'o.c. otrT oul (3) ExrsTrl{o RooF RAFIERs BRA6E TO NEI,^I4xil2 HEADER AND EXrsTrNa EXTERTOR l^lALL TOP P\ATE.lr z __$ D_ frs {.f) -o>D_{OMMTLLu_ooM s\$rna bxol<qD J-kgt-z s5t- F.- F v_o TL ={\nz M 0n Dz zz vo[L tu\)zluA6tuv 9HEET'4 OF 5 gHEETS 7t 04/t1/o1 l/4" = I @) RICHAR' BER6 AR6HIIE6T:.2001 f]lil r) Yf, Y)lf, c,lti.. &t: L q.i C1 Cra ? l,:l A:" !,t. gIMPgON L3O ANOLE EACH 3}DE OF EX{gTINO RAFTER 4XIO OORI"IER RIP@E EEAM 6ONNE6TED TO 4XI2 HEADER ,',llTH 3|MF9ONU4lO'3RID6E \ENT 4XIO PORMER RID6E BEAM - (3) 2XIO MAIN ROOF RAF]ER BEYOND, CONNECTED TO 4XI2 HEADER lrIITHU2IO.T T 2XIO DORMER RAFTER5 cONNECTEP IQ 4XIO DORMER RIOOE BEAM,^tlTH 9ll"'lPgON 'RR' HAN6ER9 DORMER ROOF ,.iooD g{lll€/LFlg10 \4ATCH EXlgTlNe 15 LB. EUILDINo PAPER I/2'COX 9HEATHIN6 2XIO RAFTER9 Ib' O.C, I,'I/ SIMPSON 'RR, HANOERS R-3O HIOH DENSITY EATTIN9 l/2' OYP$M I,^,IALLEOARP I^.I/ LOI^.I.PERM FRIMER ROOF CONT VENT, EACH gIPE l2 4Xl2 HEADER 6ONgTRUOTION TO EXISTIN6 NINDOIa| ROOF TO MAT6H EXI9TIN6 (z d.9d NDO'4 STYLE AND l.llNDOl^{ TRIM TO MAT6H EXI9TIN6 ATTA6H'gKIRT' RAFTERg TO 18 PLATES l,.l/ HURRIcANE TIE5, EXI9TIN6 ROOF TO REMAIN, MATCH EXISTINo PETAILg n .56s-f Eo 3s13\S$t{} *l -I$xE Ue-H$'$ E URs$ ' P;ES EFFrt \)fL f;F\)LttF =\)v- (DwilI6 hv. :t\)e Hg(nno= pH l/2'oY?g)t"1 R-2t 15 LB. l/2" l'-ou INgJLATION Nl PRIMER OR NALL' EXI9TINO NA PAPER gHEATHIN@ lb'o.c. "ll lNTERlt i' 6YFfll"1YlN-ffiD Z'6YP9UM I{AI )R lr.hLL.-- LBOARD >i lb' o.c. ,, ,LBOAW-lttN6 )oR (3) 2XtO NEr,l RAFTERS UNDER PORMER CHEEK MLL3, EACHSIDE. l \f)z { M-m Gz zz { s\$roo t_js- ist <M<Ort--) -ks|- z. H6F- l-- Fvo TL votL rf)tu v_ AND 'IDE ROOF VANITY CABINET o) 2X4glUD'sELOl'! TRIPLE RAFTERg, PROVIDE %LID LOAD PATH UNDER POINT LOADS TO FOUNDATION BELOII B) zxto L30 RAFlER CONNECTED TO TOP PLATE }^{ITH 9HEET, 1 OF 5 +4EET5 90ALE,l/2" = l'-O"SCALE' l/2" = l''O"4t,.tqi?-ze ur C| I-In $lt -I o o 7 o T n (J $rT l n q)n c\ I {rn c\ -l !i * l\ )o o J ,g H .i ' + \J !E : Ga c 56 6 s li t n I ie i r I t l" . l f i: .: Ri C H l o r ' PR E P C S E D SE ' T C N S o -n \I T LT I AN N AN P BR . Y A N 5A U Tq TA Y L O R 9T . PO R T TO l , . l N g E N D , l, { A qb S b b RE g I P E N C E FO R . RI C H A R P 9E R 6 AR 6 H I T E 6 T 5 , P. 6 1I q TA Y L O R gT R E E T PO K r ro f f i . l g E N p , Mq f f i b b fl w E , (% o ) f l q - ^ a o rl x , eb d 71 4 - b 3 2 4 ri c h a &r l c l n r Mr E* ch l t e cl s cq t r $i rr n rn <o al t tt { -O IJ o Lt ,,is jyf.'i{57