HomeMy WebLinkAboutBLD07-165 Oversize drawings not scanned)')
BUILDING PERMIT
City of Port Townsend
Development Services Department
250 Madison Street, Suite 3, Port Townsend, WA 98368
(360)379-s09s
Project Information
PermitType CommercialMiscellaneous
Site Address 830 WATER ST
Project Description
Fire Alarm System
Permit #
Project Name
Parcel #
BLD07-165
Fire Alarm System
989704106
Names Associated with this Project
Type Name
Applicant Cracker Factory Llc
Owner Cracker Factory Llc
Contact Phone #
License
Type License # Exp Date
Fee Information
Project Valuation
Building Permit Fee
Plan Review Fee
State Building Code Council Fee
Technology Fee for Building Permit
Record Retention Fee for Building
Permit
3 10.00
210.50
4.50
6.20
10.00
Total Fees $s41.20
Call 385-2294 by 3:00pm for next day inspection.
Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180
days. Work is verified by obtaining a valid inspection.
Thegrantingofthispermitshallnotbeconstruedasapproval toviolateanyprovisionsofthePTMCorotherlawsorregulations. Icertiff
that the information prov of the application for this permit is true and accurate to the best of my knowledge. I further certifu
authorized agent ofthe owner.that I am the owner
Datelssued: 081071200"1
Issued By: SFOSTER
Print Name
asa
I
)
Permit # BLD07-165
1. Contractors working on this project are required to have a Labor & Industries contractor's registration
number and a City business ficense. Failure to provide proof of this documentation prior to work may
result in job shut down while this is accomplished.
2. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
3. Re-inspection is required after inspection report corrections are completed.
4. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call38{2294. A
minimum of twentv-four hours notice is required. Public Works approval must be received prior to
schedulins the Building Denartment's final inspection.
5. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-
residential project.
6. All building permits expire if no progress has been made within six monthsn or if no inspections are done by
the Building Department within one year. Call for at least one inspection per year to keep your building
permit active.
7. Revisions require submittal & approval prior to making changes in the field. Contact the Development
Services Department @37y5095 prior to making changes to the approved plans.
8. POST THIS PERMIT ON-SITE WITII THE APPROVED PLAI\S.
GENERAL CONDITIONS
'. \
CITY OF PORT TOWNSEND
PERMIT ACTIVITY LOG
PERMTT #BLDO7- bS DATE RECEIVED 8-7-o7
SC OF WORKa #,fva (=l
DATE ACTION INITIALSa-a-b4 ENTERED INTO CHET =rCA - to Planning - No evidence
CHECKED FOR COMPLETENESS
B-A-Og.C)nEC-K b;LL be- n0: LaI lvT-;D L/3=
I
8 -/b -07 Aln GEKT4 7D b4a'ua i,tt o6/ ol //,a/1/5 6a,4 5FL;71r S)aal-otsl 4n be ldfr ra/ 6t'?sth?-'4
f
\
)
Development Servfces
Co ntact/Representative:
Name:
Address:
City/SUZip:
Phone
Email:
250 Madison Street, Suite 3
Port Townsend WA 98368
Phone: 360-379-5095
Fax: 360-344-4619
www.cityofpt.us
Lender lnformation:
Lender information must be provided for projects
over $5,000 in valuation per RCW 19.27.095.
Name:
Project Valuation:$
Construction Type
Occupancy Rating:_
Building lnformation (square feet):
1"t floor
2nd floor
3'd floor
Restrooms
Deck(s):_
Storage:_
Basement:_ ls it finished? Yes No
Other:
New tr Addition tr Remodel/Repair n
Change of Use tl
Total Lot Coverage (Building Footprint):
Square feet:_ %
lmpervious Surface:
Square feet:_
Gommercial Building Permit Application
) Applications accepted by mail must include a check for initial plan review fee of $150
F See the "Commercial Building Permit Application Requirements" for details on
plan submittal requirements.
Property
Name:
Owner:9.. *=Q.Ze AL
Address:
City/SUZi
Phone
Email:
Contractor:
Name: T?ila:+SYsttns Zttc
Address : <7otr S, ?--,un AX
C
Phone
Enail: 0 P!- e-'TE;r4 P*Sysrriu^savLc_b yL
State Licens e #: l.OLLlq fl q e^p, 7'N
City Business License #:
I hereby certify that the information provided is correct, that I am either the owner or authorized to act on behalf of the bwner
and that all activities associated with this permit will be in accordance with State Laws and the Port Townsend Municipal Code
Print Name:
Project Address & Zoning District:
#
c."83a t<srlrE (3-
4/ /o
Legal Description (or Tax #)
Addition:
Block
Lot(s)
Project Description
Office Use Onlv
D,/ - lLs
Associated Permits:
Permit
Signature:
B*"e
Date: K-TD?
,.)
COMMERCIAL BUILDING PERMIT APPLICATION
CHECKLIST
This checklisf is for new construction, additions, and remodels. The purpose is fo show what
you intend to build, where it will be located on the lot, and how it will be constructed.
. ' Commercial building permit application.
f Non-Residential Energy Code forms: * Lighting * Mechanical # Envelope
I Three (3) sets of plans with North arrow and scaled, no smaller than 1/o" -- 1 foot'.
I Title Page/Cover Sheet:
1. Project identification
2. Project address, legal description, location map, tax parcel numbe(s)
3. All design professionals identified including addresses and phone numbers4. Name, address, and phone number of person responsible for project coordination5. Design criteria, including occupancy group, construction type, allowed floor area vs.
proposed, occupant loads, height and number of stories, deferred submittals, etc.6. Designate compliance with all applicable codes
I A site plan showing:
1. Legal description and parcel number (or tax number),
2- Property lines and dimensions
3. Setbacks from all sides of the proposed structure to the property lines in accordance with a
pinned boundary line survey
4. On-site parking and driveway with dimensions
5. Street names and any easements or vacations6. Location and diameter of existing trees7. Utility lines
B. lf applicable, existing or proposed septic system location
9. Delineated critical areas boundaries and buffers
I Foundation plan:
1. Footings and foundation walls
2. Post and beam sizes and spans3. Floor joist size and layout
4. Holdowns
5. Foundation venting
I Floor plan:
1. Room use and dimensions
2. Braced wall panel locations
3. Smoke detector locations
4. Attic access
5. Plumbing and mechanicalfixtures
6. Occupancy separation between dwelling and garage (if applicable)
7. Window, skylight, and door locations, including escape windows and safety glazing_l
Wall section:
1. Footing size, reinforcement, depth below grade
2. Foundation wall, height, width, reinforcement, anchor bolts, ahd washers3. Floor joist size and spacing
4. Wall stud size and spacing
5. Header size and spans
6. Wall sheathing, weather resistant barrier, and siding material
7. Sheet rock and insulation
B. Rafters, ceiling joists, trusses, with blocking anb positive connections9. Ceiling height
)
)
Permit # BLDO7-165
CITY OF PORT TOWNSEND
PERMIT AND INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 lor lnspection
PermitNumber BLD07-165 lssued_Q@ ParcelNumber 989704106
Job Address 830 Water Street. El Zoning Q!!!
Nature of wort< lnstall Fire Alarm Svstem occupancy-Sfllf$!
owner Ritch Sorqen Gontractor Techna Svstems lnc.602219379
****See attached Fire Dep ***
Site Inspection
Mounting Heights - manual device mounted 42 - 48
inches abovefloor
Date
Svstem Tests
Annunciator Panel
Duct Smoke Detector Activation Signal
Acceptance Tested by Code Official
Date
tIt
Contractor's Material & Test Certificate T/lrr"'Dl*
As-Built Plans filed with Owner & Plan Box
@ FACP (24 x 36 maximum format)
Inspector
Date
Date
t
Fire Department Final Inspection Approval
Date
^) ) Q,' Jo - /D 4/4
TLS
CITY OF PORT TOWNSEND
DEVELOPMENT SERVICES DEPARTMENT
INSPECTION REPORT
For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want
the inspection. For Monday inspections, call by 3:00 PM Friday.
DATE OF'INSPECTION:
SITE ADDRESS: 936
?-K-or PERMIT NUMBER: BDOT ^ lLf
h)revL SC
PROJECTNAME: CU+t*u furc,zV <tTSONTRACTOR: 1&tfis4 9fSZttrs-7l'<-
CONTACT PERSON: 3. f,,4usg+ R*tq*r- PHONE: tlZf- S8 -Af:O
TYPE OF INSPECTION:rP
5z sas
5
6 /a-
ru"t.fi',
N APPROVED ! NOTAPPROVED
checked at next inspection
Call for re-inspection before
proceeding.
Date
and permit card must be on-site and available at time of inspection. A re-inspection fee may
be assessed if work is not readyfor inspection.
')
City of Port Townsend
Fire Department
Offrce of the Fire Code Official
Fire Protection Svstgm Inspection Chepklist:
.dutomatic Fire Alarm Svstem
/., o+- tbrGeneral. Building PermitNo.:. Facility Owner/Mgr.:. Facility Address:. Facility Name:. Facility Contact No.:
Svstem:
EI Manual fl Automatic
Panel Reset Code
' Code Number:
)
E Voice E Monitored EI Graphic E Stand Alone
ffi ERateofRise 6t{^ru" ,z/*'o* -,ffomlStrobe
ln:'
1, Egress Control ,dVanualPull-station -Ef Strobe /fi,zd),r-.t,E Monitoring Agency Test E Emergency Power Source'.f,' Fve Alarm System Inter-tie with Sprinkler System Test (Tampe): 7Z Secs.
Elements:
E Heat El Rate of Rise E Smoke
tr Coiling Door El Manual Pulls E Duct
Co+tractor's State License [& NICET]:
Plan Review
tr Plans Received [Date:tr Mfr. Specifications of individual elements
tr Floor Plan(s) complete
tr Battery Calculations, wring types and sizes.
tr Power connection, Emergency Power Source
Site Inspection
tr System installation/location check-off
tr Panel Location
tr Remote Annunciation
tr Access Keys
tr Labeling
tr Operatinglnstructions.
tr Tools
9q4fractoros Matefiql & Test Certifiqate;
Aq-BUllt PlansAnstructions in Plan Box @ FACP:
Monitoring Agencv. Name:. Address:. Contact Number:. Account Number:
El Hom tr Horn/Strobe El Strobe
E Egress Control E Damper El Other:
Inspector Int. & Dt.:
lnspector lnt. & Dt.:
Inspector Int. & Dt.:
Int. & Dt.:
Inspector Int. &
Inspector Int. & Dt.:
/a*
?
/^/*/-/
Fire Denartment Apnroval. Inspector:. Date:. Filed w/Bldg. Official:
C:\Documents and Settings\TomMy Documents\Business\City Contract\Forms & Templates\Fire Alarm System\Fire Alarm System InspectionChecklist.doc 8113/07
)
Thomas L. Aumock
Consulting Fire Code Official
2303 Hendricks Street Port Townsend, WA 98368
Office : (360) 385-3938 Emait taumock@cablespeed.com Cell: (360) 643-0272
TO:
FR:
DT:
RE:
FIRE ALARM SYSTEM PLAII REVTEW MEMORAI{DUM
Jan Hopfenbeck, Development Services
Thomas L. Aumock, Asst. Firen@flL6&-elf
Fire Alarm System, Eisenbeis Bldg., 830 Water Street
This consulting Fire Code Official is in receipt of the set of plans for the above-referenced proposal from
your office.
The above-reference proposal was reviewed relative to the International Fire Code U.F.C.], 2003 Edition,
and Washington State Amendments, and the following constitutes this plans examiner's findings and
detGrminations based upon the plans of record submitted.
Findings. Determinations. and Requirements:
l. The proposal was reviewed as a Group B and Group R occupancies; and,
2. An fire detection alarm system is required for this occupancy and is subject to Section 907 of the
International Fire Code in conjunction with the provision of automatic sprinkler system approved under
BLD06-198; and,
3. The fire alarm system plan is found to be designed by a licensed alarm technician under the
provisions of National Fire Code 72 and related sections; and,
4. The fire alarm system shall be installed by a licensed alarm technician under the provisions of
National Fire Code 72 and related sections; and,
5. Visible alarm devices shall be located in all public common areas [IFC Chapter 907.2.1.1]; and,
6. Manual fire alarm devices shall be mounted at least 42 inches and not more than 48 inches above the
floor [IFC 907.4.2f; and,
7. The annunciation panel and associated controls shall lock-in until the system is reset and shall not be
canceled by the operation of an audible-alarm silencing switch [IFC 907.9.1]; and,
8. Any provision of Group Rl accessible sleeping units shall be provided with a visible and audible
alarm notification appliance, activated by both the in-room smoke alarm and the building fire alarm
system [IFC Section 907.10.1.3, based upon the number required under Table 907.10.1.3]; and,
' 9. Elevator detection and shunt trip shall comply with ASME A17 .3, and;
10. The system may be monitored by an approved remote agency [IFC 907.151; and,
11. The fire alarm system shall be acceptance-tested in the presence of the Development Services
Department representative IFC 907 .l7l; and,
12. A formal confidence test report shall be provided for this system after satisfactory acceptance testing,
[copy attached] IIFC 907.18]; and,
13. A complete set of as-built drawings of the completed system shall be provided on-site in a formal
plans box adjacent to the FACP, submitted on a24 x 36 inch maximum size format, and an architectural
CD provided for emergency response use, if available UFC 907.191.
Any other applicable or relevant sections of said Code not covered herein shall nonetheless apply to this
proposal.
1.5 hours time was consumed in the review of this proposal
It is the recommendation of this plans examiner that the proposal be approved subject to the aforesaid
requirements.
Citv of Port Townsend
Fire Alarm Plan Review Checklist
NT'PA 72
Building
Address:
Permit #
Name:ffiEE
Date:?8ry+eCZlaT
fnshllation Co.Installer Name:
Reviewer: T
Instructions: Answers shall be circled or written in whichever applicable.
t. Manufactur er: ?tz.av/ A/td+/6,nt ^.6"1 ZVrZzt P4ta6r€#3larm panel
and components (provide copy of spec sheets) Choices: okay, need, or N/A.
Equipment is listed for use. Choiceq(t6}needn or N/A.
A. Equipment/symbol legend. Choices:@eed,or N/A.
B. Total number of devices Choices z@need, or NlA.
C. Device location (provide ceiling sectional when detectors are used). Choices: @eed,
or N/A.
D. Type of devices (detail device wiring: detector, horn, flow, tamper, etc...) Choices: @
need, or N/A.
E. FACP location (remote annunciator to be located near main entrance or
per AHJ) Choices:
F. FACP is in a protected area (
or N/A.
-
i"""i,ffi*:*q-m fr nrt fr e e Emo*4tll
G. Typ" #. A-U%-FA and gauge(s)
-
or wire or cable. choices:
@o"eoif-o. N/A.
I. Riser diagrams with: # and type of devices per circuit, zoneID.,l20 dedicated batteries,panel,
etc... Choicesz(@, need, or N/A.
Drawing:
2. Three sets of drawings.
3. Floor plan showing: scale:
(Also: label the rooms and provide
or N/A.
room dimensions ).
use one of the following: %,@8, Ul6
Choices: dffi)eeO, or N/A.
4. Point to point system wiring diagram: Choicesld@, need, or N/A.
A. Interconnected of identified devices and controls. Choices: (FlPzneedo or N/A.
B. Indicate number of conductors in each run. Choices: okayn need, or N/A.
C. Identify zonelcircuit and EOL's. Choices7@needo or N/A.
circuit load consumption of circuits on drawing (showing voltage drop)5. Alarm
needo or N/A.
A.of signaling devices on most demanding circuits and current consumption. Choices:
n need, or N/A.
Length of longest circuit and resistance of wire (use NEC resistance specs of provide
manufacturer spec sheet). Choices: @, need, or N/A.
no. Choices:okay, needo or@C. Show formula servlce:yes
6.24 flgur monitoring service: yes
orf@
no. Choices:okay, need,
21. Battery calculation sheet showing:
A, Standby power consumption of all current drawing devices times the hours required by
NVPA (24 or 60 hours) including power consumption of the control panel modules. Choices:
@"i"d, or N/A.
7. Transmittfurg device detailed and spec sheet provided for 24 hour monitoring. Choices: okay,
need, o"l@."
8. Show detector protection on airlheat ducts and their air change per minute rating. Choices:
okay, need, or ffi,.
9. Show means of activation of magnetic door-releasing hardware and /or
Ventilation shutdown. Choices: ohy, need, or@.
10. Show placement of HVffiir supply/return ceiling vents if detectors are in close proximity.
Choices: okay, need, or W(M
11. Show that the audible evacuation devices will activate by operation of the sprinkler system
and/or the sprinkler supervisory switch is to be connected to the fire alarm system (#Il & 12 are
to be separarc signals; i -S.+. S. C hoicesz,@oneed, or N I A.&z- aO* - Z e d
12. Sprinkler tamper switch is to cause troubJe light and buzzer indication at the annunciator
panel only. Choigss2 r{Q,needr or Wnr.4ea"/aza-/"9
13. Fire alarm warning devices shall be audible throughout the occupancy at least a minimum of
15dB's above am-lient noise level or 5 dB's above maximum noise level (will verifu during field
test). Choi""*, @ needo or N/A.
14. ADA waming devices (strobes) are provided. Choices: $f,VJ""d, or N/A.
15. Show two sources of electrical power. Choiceszrd?need, or N/A.
16. Show that the main powq-supply for the fire alarm is on a dedicated branch circuits and
properly signed. Choices: ffineed" or N/A.
17. Manual pull stations are to be installed at eaoh exit or stairway or other areas as required, not
exceeding 200' travel distance. Choices: @need, or N/A.
18. Show location of fire alarmfire emergency phone jacks. Choices: okay, need, or@.
19. W:yrua Wflr#lare connected to FACP. Choices : p*# need, or N/A.
20. Speaker amplifier and tone generating equipment integrity is monitored. Choices: okay,
needo offi.
B. Power consumption ofra{
detectors, etc. Choicesz ffiz!,
C. Alarm power consumptions of all-current drawing devices times the minutes required by
NFPA (5 or 15 minutes) Choices: &j,need, or N/A.
D. Formula format for battery calculations. Choices: 6rneed, or N/A.
devices on standby power, including door holders, relays, smoke
need, or N/A.
Date:
Date:Disapproved:
Review Comments:
CITY OF PORT TOW}{SEND
Development Services l)epartment
F'IRE ALARM SYSTEM INSTALLER MATERIALS & TEST CERTIF'ICATION
Address: 33O h),*n*a-$,-.Business Name
Representative:
Location of Plans
Location of s Manual:
Permit #Date: ?-7*4?
Tvne of Svstemlsl or Service
f NFPA 72
Art,760 of NEC
Manufacturer' s Instructions
Other (specifu: FM, UL, etc...)
ControlUnitManufacturer: S'lZF.anf PNI eVf Model No. { 7OO
Circuit System:
Number of Circuits
Software / Version:4.,rt&z
-f - e-trLoq* 't7*veaInstaller:
Supplier:7k r+AlA wgrt4ras, it-tt'
System Details
Ll Manual n Automatic n Voice tr Monitored
Alarm *Initiating Devices and Circuit fnformation
Quantity Circuit Style
is-AxilfiE$tuAc€
n Graphic n Stand Alone
"7 /AparESAScE
Abaf,,g<,t+jg.E
A^}ile\*&tt
Manual Fire Alarm Boxes
Ion Detectors
Photo Detectors
Duct Detectors
Heat Detectors
Transmitters
Egress Control
Water Flow Switches
Supervisory Switches
/4
--T-
JIB
Other: Specifu
Other: Speci$'
Alarm Notilication Appliances and Curcuit fnformation
Quantity Circait Style
Bells
Horns
Horns / Strobe Combination
Chimes
Strobestf
Speakers
Other: Speciff
Other: Specifu
C:\Documents and Settings\TomMy Documents\Business\City Contract\Templates\Fire Alarm Systems\City Fire Alarm System Materials & Test
Cert..doc 3D8AOO7 1
--
Sisnalinq Line Circuits
Quantrty
Quantity
and stvle of sienalins line-circuits"4 connected to system fsee NFPA 7Z,Table 6.6.11
Circuit Style I
Svstem Powef Supply:
Primary [Main]
Amps:2a
Amps:ti)
Nenr ?'b fi4cf,.
Disconnecting Means Location: Ctn ot.r* I €
Secondary [StandbyJ
Storage Battery:4 x -7t* I7.tx<-
Calculatod capacity to operate system:24 hours:
Battery
Emergency or Standby System PeTNFPA 70:
Site Iletails
Remote Annunciation Location[s]ll4Art (lrs*rac, ^EPwy i FAoP
Access Keys:kttOX I erl
Amp Hour Rating:
60 Hours
Operating Instructions: fuci F**g'C
Tool forManual Pull Station Reset: p(C/ PaF'ga
Svstem Test(s)
Type
Control unit
Interface Equipment
Lamps / LED's
Fuses
Primary Power Supply
Trouble Signals
Disconnect Switches
Ground Fault in Monitoring
Secondary Power
Battery Condition
Load Voltage
Discharge Test
Charger Test
Specific Gravity
Transient Suppressors
Remote Annuanciators
Notification Appliances
Type. Audible. Visual. Speakers. Voice Clarity
FunctionalVisual Comments
fi-
F-
W-&
Fl-
g-
Fa
g-
Functional
F:
E*-
ts*&
&
E"
h
w
r
6.
W
n
bF-
&
B
u
n
w
Visual
&-
EJ-*
*
Comments
C:\Documents and Settings\TomMy Documents\Business\City Contract\Templates\Fire Alarm Systems\City Fire Alarm System Materials & Test
Cerl..doc 3/28/2007 2
Initiatins and Supervisory Device Tests and Inspections
Location & S/N Device Visual Functional
Type Check Check
Comments:
Factory
Setting
Measured
Setting
tr
n
!
!
!
I
u
I]
n
!
n
n
Emerggncv CommFnications Eq uinment
Type Visual
Phone Set n
Phone Jacks F-
Off-hook Indicator B'*
Amplifier[s] n
Tone Generator[s] n
Call-In Signal W
System Performance W
Interface Equipment
Visual
ISpeci$,]
ISpeciS,]
ISpecifl']
ISpecifu]
Special Hazards Svstems
ISpecify]
ISpecifi,]
ISpeci$]
Special Proceduresl
Functional Comments
!
E-
a=
!
t:]
h
E-
Device
Operation
n
!
!
!
u
tJ
tr
Simulated
Operation
!
tr
!
n
!
!
n
n
n
tl
{]
u
u
n
Comments:
Supervipins Station Monitorins
Alarm Signal
Alarm Restoration
Trouble Signal
Supervisory Signal
Supervisory Restoration
$upervisins Station Monitorins Contact. Name:. Address:. Contact Number:. AccountNumber:. System Code Number:
No
tr
ll
tr
n
u
Yes
Et-
,a*&
E<
W
Time Comments
C:\Documents and Settings\Tom\My Documents\Business\City Confiact\Templates\Fire Alarm Systems\City Fire Alarm System Materials & Test
Cert..doc 3128/2007 3
-",-'
--,-
Certificatipns & Annrovpls
Certification of System Installation: This system installation was installed, inspected, and tested
to comply wi installation requirements of:
NFPA 72
Art,760 ofNEC
Manufacturer' s lnstructions
Other (specifu: FM, UL, etc...)
Signed:
Instal ler's S ign at ure :
Print Name/Co.
Date: 5Y" t?-1)V
Certification of System Operation: All operational features and functions of this system were tested and
found to be properly in accordance with the requirements of:
NFPA 72
International Fire Code, 2003 Edition [with Wa. State Amendments]
Manufacturer' s Instructions
Other (specifr: FM, UL, etc...)
AHJ Approv ing Inspector's S ig nat ure :
Print N 'T/a/1485 L ,frirn a'eAL
Signed:Date
Notes
C:\Documents and Settings\Tom\My Doouments\Business\City Contract\Templates\Fire Alarm Systems\City Fire Alarm System Materials & Test
Cert..doc 3t28D007 4
l"'r I -t )))
Techna Systems Inc.
5205 South2nd Ave
Everett, Wa 98203
425-2s8-8053
Proj eot:EISENBEIS &SONS BLDG.
Address: 830 WATER ST. PORT TOWNSEND, WA.
Please contact:DoMINIC CARBELLo when completed @ 4zs-50s-0803
Comments:
Perm
Building Official
CITY OF PORT TOWNSEND
l
\
I
I
I
I
I
I
t
i,lAtl - 6 'iua]
V
@
g
J
.
a
o
d
r
v
t
f
l
f
'
7
q
e
l
,
v
f
f
i
q
?
?
,
v
t
€
1
9
A
'
?
d
l
a
d
'
t
r
-
?
'
^
7
1
2
a
l
t
g
f
z
r
t
"
t
q
?
l
w
r
?
'
t
?
1
3
,
i
z
t
w
7
a
,
s
b
h
s
z
l
h
{
N
N
h
l
(
(
s
'
Y
,
t
3
s
/
A
!
r
r
t
-
r
r
{
T
?
,
0
4
\
)
)I')a
W
ffi<
€rgrrjc>
H6AIJ s-rges€ - Svsrca+ s€}rse&dgrt- pe€}
*6rns*g a'rirY * .Sy$?-grur s*'d/#'"g iGs -S{fl\
- Fa& kJp)
- UJuxr*e*?aoor f-foq'd SraoEe - €#to*prt ;1" nr#e" & (6H
* FtseN - s*€rceu #elsr,t€' tf>A -t'{tu}e}t.- \r tsa *9s +'$l
- ltAnPt't *t flog'€ Fur{'*'*rt#t''3 -*;L&Nf 6'l"tt{*tl
I dE*f**'d.ftn)
4ope*ss*gte trJgrl{', nnouur'€ * sf t8#r g&rfs's
(ga aw - 4**)
-A&se"€ss*{stg
Rgai4Y gw*b*q& - Sl {d*'r" g#rg'vr-
Cs* s^*s * 4P$)s -hctr#&$"$q6{f
S$aos'g I}€T*c'rr'W* - St #a'q taN t6 tt'r
e,"rd r
h$
- PeYrrwY ft*t[tttlet frroL"ste-€Nr *,Ptt&ttr ( gg**)
- Fttsg flt'PGM e[:nhi'A*L fu-FJS t,,- st Lt/.]r #Nt &Nr d s zao )
.^ ad -" .1* f[Soe$ lg$F$r'f c l'6 Sceg^ff #NtaEf {x w**}
f\4rat tM
f
I
I
R
*A
r ftil
Global Project Values:
Projeci Name:EISENBEIS & SONS BLDG.Standby
Project lD B3O WATER ST Alarm Min
Prepared Derating
Voltage Drop Waming
Threshold o/o
Fanel lD:
Location:
5700
BASEMENT
Model: 5700 Add. Fire Alarm Control Panel
Volts; 24 VDC
Max NAC Current: 2.5 Amps
Max Panel Cunent 2.5 Amps
TECHNA
31212007
ckt.#Circuit Name Qiy uurrent uraw WireAWG
& Tvoe
Ohms Per
1 000 Ft.
Length(tt)
One-Wav
.Actual Volts @
EOL %DropStandbv Alarm Ohms
5700 5700 CTRL Panel 1 0,206 0.356
SLC.DEV Addrsbl SLC Devices 30 0:002 O,017
5860 LCD Remote Annunc 1 0.020 0.025
5824 Serial/Parallel Module 0.000 0.000
5496 Power Expander 0:000 0.000
5865-4 LED Annunciator (4G)0:000 0,000
5865-3 LED Annunciator (3G), 0,000 0.000,:'
5880 LED Driver Module 0.000 0;000
Other ' 0:000',0.000 ,,
Other ,:0:000 0,000
SD-Duct Duct Hsg w/Relay ,0.000 0.000
5883 Relay Module 0,000 0,000
PGM-|/O#1 HORN BOOSTER INIT 0.000 0.000 #12 Solid 0:00%
PGM-I/O #2 Notification Aool Circuit 0:000 0.000 #12 Solid 1_5S 0.00e/o
Total Standby Current {Amps)0.228 ,0.398 Total Alarm Cunent {Amps'}
Standbv Time ln Hours 0.083 Alarm Time ln Minutes / 60 (5 Mins)
13 65q n n??Total Alarm AH Reouired
Total Combined AH Resuired
Multiolv Bv The Deratino Fastor 1.24
Minimum Batterv AmpHours Required
Command Shortcuts
Configure Circuits Print Page
SILBNT
I(NIGHT
5495 Power Expander Calculations
Global Project Values:
Project Name:
Project lD:
Prepared By:
Date:
EISENBEIS & SONS BLDG
B3O WATER ST
TECHNA SYSTEMS INC.
Alarm Mins:
Deraiing Factor:
60
1.2
3t2t2007 Voltage Drop Warning
Threshold %10
Wire resistances are based upon an ambient temperature of 72 degrees F. Because of
the minimal difference between solid and stranded wire no differential was made,
Wire resistances are based upon an ambient temperature of 72 degrees F, Because of
the minimal difference between solid and stranded wire no differential was made,
5
Panel lD:
Location:
5495(1 )Model: Silent Knight 5495 Power Expander
Volts: 24 VDC
Max Circuit Current: 3 Amps
Max Panel Current: 6 AmpsBASEMENT
cK.#Circuit Name Cunent Draw
Standby Alarm
Wire AWG
& TYPe
Ohms Per
1000 Ft.
Length(ft)
One-Way
Aclual
Ohms
Volts @
EOL %Drop
I BSMT & 1ST FLOOR 0.000 1.028 #16 Solid 4.02 200 l.o I 18.75 8.1070
2 MEZZANINE LEVEL 0,000 0.548 #16 Solid 4.02 200 r.o I 19.52 4.32o/o
J 2ND FLOOR 0.000 0.380 #16 Solid 4.02 200 1.61 19.79 3.00%
3RD FLOOR 0.000 O:427 #16 Solid 4.02 200 1.61 19.71 3.370
Aux 5495(1 ) Aux Power Out 0,000 0:000 #16 Solid 4.02 0.00 20.40 0.000/o
5495 5495 Power Expander 0.075 0.205 2.383.,(Amps) Total Output Power Required
Total Standby Cunent (Amps)0.075 2.588 Total Alarm Cunent (Amos)
Standby Time ln Hours 60 0.083 Alarm Time ln Minutes / 60 (5 Mins)
Total Standbv AH Reouired 4_500 0,216 Toial Alarm AH Reouired
Total Combined AH Required 4.72
Multiolv Bv The Deratinq Factor 1.20
Minimum Batterv AmoHours Required 5.66
Panel lD:
Location:
5495Q\Model: Silent Knight 5495 Power Expander
Volts: 24 VDC
Max Circuit Current: 3 Amps
Max Panel Current: 6 Amps
ckr.#Circuit Name Cunent Draw
Standbv Alarm
Wire AWG
& Tvpe
Ohms Per
1000 Ft.
Length(ft)
One-Way
Actual
Ohms
Volts @
EOL %Drop
I 5495(2\ Circuit '1 0.000 0.000 #12 Solid '1.59 0.00 20.40 0.00%
5455(2\ Circuit 2 0.000 " 0,000 #12 Solid 1.59 0.00 20.40 0.00%
a 5495(2) Circuit 3 0.000 0.000 #16 Solid 1.59 0.00 20.40 0.00%
4 5495(2) Circuit 4 0.000 0,000 #16 Solid 1.59 0.00 20.40 0.00%
Aux 5495Q\ Aux Power Out 0,000 0,000 #16 Solid 1.5S 0.00 20.40 0.00%
54S5 5495 Power Expander 0.075 0.205 0.000 (Amps) Total Output Power Required
Total Standbv Cunent (Amps)0.075 0.205 Total Alarm Current (Amos)
Standbv Time ln Hours 60 0.083 Alarm Time ln Minutes / 60 (5 Mins)
Tnial Standhv AH Renrrired 4.500 0.017 Total Alarm AH Reouired
Total Combined AH Required 4.52
Multiply By The Deratino Factor 1.20
Minimum Battery AmpHours Required 5.42
GHT FIRE ALARM CONTROL PANEL
lnrelliKnighr@ Model 57oo
Single Loop Addressable
Fire Alarm Control System
The affordable addressable fire alarm
control panel solution.
lntelliKnight Model 5700 is a 50 poini class leading single loop
addressable fire alarm control/communicator system. 5700 provides you
with the revolutionary value and performance of addressable sensing
technology combined with exclusive, built-in digital communication,
distributed intelligent power, that includes an easy to use interface. Powerful features such as drift gompensation
and maintenance alert are delivered in this powerful FACP from Silent Knight.
For more information about the lntelliKnight system, or to locate your nearest source, please call
1-800-446-6444, or in Minnesota, call 763-493-6435.
Description
5700 performs drift compensation and
calibration checks on each of the
sensors in the system.
The basic lntelliKnight 5700 system
can be enhanced by adding modules
such as 5860 remote annunciator,
5824 serial/parallel printer interface
module (for priniing system reports),
and 5496 intelligent power module.
5700 also features a powerful buift-in
dual line fire communicator that allows
for reporting of all system activity to a
remote monitoring location.
Features
. Up to 50 addressable points. Up to 125 zones and 125 output
groups. Uses standard wire-no shielded or
twisted pair required. Built-in digital communicator.. Central station reporting by point or
by zone. Supports Class B (Style 4) and Class
A (Style 6 or 7) configuration for SLC. Distributed, intelligent power. Drift compensation. 13 pre-programmed output cadences
(including ANSI-3.41) and 4
programmable outputs. Notification circuits configurable as 1
Class A (Style Z) or 2 Class B (Style
Y), or auxiliary power for resettable,
constant, or door holder power. Built-in synchronization foTAMSECO,
Gentex@, Faraday, System Senso@
and Wheelock@ appliances. Built-in annunciator with 8O-character
LCD display
. RS-485 bus provides communication
to system accessories. Upload or download programming,
event history or detector status
onsite or from a remote location
using a PG and 5660 Silent Knight
Software Suite (SKSS). lmprovements in SKSS deliver five
times faster upload/downloads. Built-in RS-232 interface for
programming via PC. Built-in Form C trouble relay rated at
2.5Aat 27.4VDC. Two built-in Form C programmable
relays rated at 2.5A at 27.4 VDC. Programmable date setting for
Daylight Saving Time
Electrical Specifications
PrimaryAC: 120 VAC,60 Hz, 1.5A
Total Accessory Load: 2.54 @ 27 .4
VDC
Notification Power: 2.54 @ 27 .4 VDC,
power-limited
Standby Current: 200 mA
Alarm Current: 325 mA
Notification/Aux Power Circuits:
2.5A @ 27.4 VDC per circuit,
power-limited
Battery Charging Capacity: 7.0-35.0 AH
Battery Size:7 AH max. allowed in
FACP cabinet. Larger capacity
batteries can be housed in an RBB
accessory cabinet.
Mechanical Specifications
Dimensions:
12.75"Wx15.2"Hx3.4"D
(32.39 W x 38.42 H x 8.57 D cm)
Weight: 11.5 lbs. (5.2 kg)
Color: Red
Model 5700
Telephone Requirements:
FCC Part '15 and Part 68 approved
Type of Jack: RJ3'1X (two required)
Approvals
NFPA 13, NFPA 15, NFPA 16, NFPA
70, & NFPA 72: Central Station;
Remote Signalling; Local Protective
Signalling Systems; Auxiliary Protected
Premises Unit; & Water Deluge
Releasing Service. Suitable for
automatic, manual, waterflow, sprinkler
supervisory (DACT non-coded)
signalling services.
Other Approvals: UL Listed;
CSFM 7170:0559:144:
MEA429-92-E Vol. XVl.
SIIENT
KNIGHT
by Honeywell
INTELLIKN IGI{T FIRE ALARM o
SLG Detectors
sD505-APS
Addressable photoelectric smoke detecior.
SD5O5.AIS
Addressable ionization smoke detector.
SD5O5-AHS
Absolute temperature heat detector that
goes into alarm imnrediately if the
temperature exceeds the programmable trip
point. Trip point range from 135oF-150oF
(o"c*37oc).
sD505-64B
Six inch base for use with detector heads
SD505-APS, SD505-AlS and SD505-AHS'
SD5054AB
Four inch base for use with detector heads
SD50S:APS, SD505-AlS, and SD505-AHS.
sD50s-6sB
Six-inch sounder base for use with existing
sensor and base. Operates in single and
mulii-station modes and/or as a system
sounder. Requires 2 additional wires for
power.
sD505-61ts
Short circuit isolator base for SD505-AHS,
SD505-APS, and SD505-A|S detectors.
SD5O5-6RB
Six-inch relay base for use with existing
sensor and base. Provides one Form C
contact.
SD5O5-ADH
Duct housing that detects smoke in HVAC
ducts.
SD5O5-ADHR
Duct detector base with relay. Provides
Form C alarm contact. For use with
SD505-APS and SD505-A!S sensors.
Compatible with SD505-DTS remote test
switch.
SD5OO.PS/SD50O-PSDA
SD500-PS is a single action pull station and
, SDSOO-PSDA is a dual action pull station.
Model SD500-l\lM
Dry contact input module for use with
normally open dry contacts. lt features an
indicator LED to show alarm status.
SDSOO-MIM
Mini dry contact input module is a small
version of the SD500-A|M. For use with pull
stations and other normally open dry contact
inputs.
SD5OO-ANM
Addressable notification module providing a
single Class A or Class B notification circuit
on the SLC.
SD50O-ARM
Addressable relay module that features two
Form C output relays. Provides indicator
LED to show output status.
SD5OO-SDM
Two-wire detector input module. Allows for
the connection of conventional 2-wire
detectors on the SLC loop. Requires two
additional wires for power.
SD50O-LIM
A short circuit isolator module for SLC
devices. When a short occurs on the SLC
loop, it is detected as a trouble, but all SLC
devices protected by the isolator module
continue to operate.
SD50O-LED
An LED driver capable of driving B0 LEDs
through the SLC loop. Up to 40
SD50O-LEDs can be used Per system.
S-BUS Accessories
5860/R Remote Fire Annunciator
Features the same B0 character backlit LCD
display keypad and fireflghter's key switch
as the 5700. The system can be fullY
programmed and operated from any 5860.
5860 is gray and 5860R is red.
5496 lntelligent Power Module
A 6 amp notification power expander that
provides four additional power-limited
notification appliance circuit outputs.
5880 LEDI|O Module
Features 40 LED
outputs; B normally
open dry contact inPuts
and one piezo output.
5865-3 and 5865-4
Remote LED
Annunciator
Features 30
Programmable LED (15
red and 15 yellow) outputs and a piezo
sounder. The 5865-4 adds a silence and
reset switch to the package.
5883 Relay Board
Features 10 general purpose Form C relays.
Used with 5BB0 module.
5824 Serial/Parallel Printer
lnterface Module
Provides one parallel and one RS-232 serial
port for connecting a printer to 5808. Use to
print a real-time log of system events,
detector status reports, and event history.
lnterfaces with building control system.
Miscel laneous Accessories
5660 Silent Knight Software Suite
User-friendly Windows software for remote
programming of 5700s using a PC. Upload
and view panel account information, event
history, and detector status.
5670 Silent Knight Softwdre Suite
End-user facility management software
allows viewing of detector status and event
history via modem or direct connection.
RBB
Remote Battery BoxAccessory Cabinet. Use
if backup batteries are too large to fit into
FACP cabinet. Dimensions:
16"Wx10"Hx6"D
(406 mm W x 254 mm H x 152 mm D)
SD5O5-DTS
Remote test switch that provides remote key
operated test function and annunciation of
detector alarm with SDsos-ADHR.
SLC Modules
:as{e sgNtp &Ma$ s*}s
S **{ea*S
r-----*-*l !
I h r a&, *r*'1,.ct r l- J
k 4r-fb-4t*4 I
1*... I
@ ff. * -s--S
5700 5496
gILENT
KNIG}TT
This document is not intended to be'used for installation purposes' We try to
keep our product information up-to-date and accurate. We cannot cover all
specific applications or anticipate all requirements. All specifications are
subject to change without notice. For more informaiion, contact Silent Knight
7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927.
Phone: (800) 328-0103, Fax: (763) 493-6475.
lntelliKnight & JumpStart are Registered Trademarks of Silent Knight- Flexput is a Trademark of Silent Knight
MADE IN AMERICA
FORM# 350392 Rev. D, 04/06
Copyright O 2006 Silent Knightby Honeywell
oo oa FIRE SYSTEM ACCESSORY
Model 5495
Distributed Power Module
ln an emergency,
you need maxirnum power.
The 5495 Distributed Power Module by Silent Knight is the most powerful and
cost-effective power supply available today. lt delivers 6 amps of notification
appliance circuit power and built-in synchronization for appliances from
System Sensor@,Gentexo, AMSECO@, Wheelock and Faraday - what you need to drive power-hungry
components like ADA notificaiion appliances. The 5495's advanced microprocessor design is years ahead of the
competition. lts switch mode power supply design is up to 50% more efficient than competitive linear mode
power supplies. And, ADA retrofits are easier and less expensive with the 5495 because it integrates into current
systems without the costly investment in new components.
For the most sophisticated and cost-effective notification power supply available, you need the 5495. Call Silent
Knight today for more information at 1-800-446-64M.
Model 5495
Distributed Power Module
The 5495 is a 6 amp notification power
expander that provides its own AC
power connection, battery charging
circuit, and backup battery for use with
fire and security controls such as the
Silent Knight Model 5208 Fire Control
/Communicator. The 5495 is the cost-
effective solution for powering
notification appliances required by the
Americans with Disabilities Act (ADA).
The 5495 has built-in ANSI cadence
pattern, which can upgrade older
control panels that lack cadence
capability.
Features. UL Listed for 6 amps of notification
power
. Power supply's advanced switch
mode design reduces damaging
heat and manages power up to 50%
more efficiehtly than other systems
. Dip switches allow for easy
reconfiguration
. 24VDC filtered output voltage
. Four power-limited notification
outputs; 2 Class A or 4 Class B, or 1
Class A and 2 Class B
Additional continuous auxiliary
output
3 amps per output circuit
2 inputs; 2 Class B or 2 Class A
Ground fault detector/indicator
. lndependent trouble relay
. AC loss delay option shuts off power
to non-essential high-current
accessories like magnetic door
holders
. Built-in synchronization for
appliances from System
Sensor@,Gentex@, AMSECo@,
Wheelock and Faraday
. Stand alone operation
. Lightweight design adds io ease of
installation and reduces shipping
costs
. Operates with most polarized, UL
Listed notification devices
. UL 864 & 1481 listed
. CSFM approved
. ANSI Cadence pattern output
capability built-in
Connection to Local Fire Control
The 5495 may be connected to a local
fire control which utilizes Class A or
Class B type notification circuits
operating between 9 and 32 VDC. The
control panel's notification circuit is
connected to one of the inputs on the
5agS. the control panel's notification
circuit end-of-line resistor is also
connected across two terminals on the
5495, which provides supervision
between the 5495 and the fire conirol
panel. Polarized audible and/or visual
notification devices are then connected
to the 5495 signal circuits using the
Model 5495
Distributed Power Module
4.7kQ end-of-line resistors provided.
Since the 5495 draws very little power
from the control, it is possible to
connect one 5495 to each notificaiion
circuit on ihe control panel and still
provide full supervision of the
notification circuits all the way back to
the control panel.
SILENT
KNIGHT
o
by Honeywell
FIRF SYSTEM ACCESSORY o ll
Model 5495
Distributed Power Module
Supervision
The 5495 supervises a variety of
functions including:
. Low AC power
. Low battery condition. Earth ground fault. Auxiliary output power limit
condition. EOL supervision trouble or
power limited condition at an
output
When a trouble condition occurs,
the 5495 creates a trouble
condition on the host control signal
circuits to which it is connected. the
5495 still maintains the ability to be
activated by the host control. ln
addition, the 5495 provides a Form
C trouble relay output as an
alternative to using the notification
circuit trouble.
Electrical Specification
AC input: 120 VAC at 2 amps
Output: 24 VDC at 6 amps
75 mA
175 mA
2 Class A (Style Z)
4 Class B (Style Y)
(1 Class A &
2 Class B)
3.0 (6.0 amps total)
20.41o 27.3VDC
@ 3.0 amps each,
4.7 kf) EOL
resistor required
on each Class B
circuit
2
2 Class B or 2
Class A
lnput
voltage range: 9 - 32 VDC
Battery charging
capacity: 33.0 AH
Ambient temp.: 32' lo 120" F
0" to 49' C
Mechanieal
Dimensions: 12.25" Wx 16" H x
3" D (30.88 cm W
x4A.64 cm H x
7.62 D cm)
lndicator Lights
AC power on : Green
Battery trouble: Yellow
Ground fault: Yellow
Aux trouble: Yellow
Output
troubles (1-4): Yellow
Approvals:
UL: 864 & 1481
NFPA: 72
CSFM
Current:
Standby
Alarm
Auxiliary
power circuit:
Notification
circuits:
Output
configuration:
Amps per
output circuit:
Notification
circuit output:
No. of inputs
lnput
configuration
4
Model 5495 Block Diagram
all
Trouble Output
{Alternativ€ to notification
circuit trouble.!
Signal 1
Signal 2
Signal3
$ignal4
Aux, Power
lnput
(0ptional)
*tA ItA r^
lnput
$ignal2
Distributed
Power
Module 5it95
$ignal Gircnit Output
$ignal Circuit Output
Local Fire Gontrol
SILENT
K}[TGI{?
This document is not intended to be used for installation purposes, We try io
keep our product information up-to-date and accurate. We cannot cover all
specific applications or anticipate all requirements. All specifications are
subject to change without notice. For more information, contact Sileni Knight
7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927.
Phone: (800) 328-0103, Fax: (763) 493-6475.
MADE IN AMERICA
FORM# 350395 Rev B,12105
Copyright @ 2005 Silent Knightby Haneywell
i}ro INTELLIKN IGHT ACCESSORY
5860 Remote Annunciator
Bring the power to control an lntel I i Kn ight
fire alarm control panel to every area
with in your fac i I ity.
Now you can operate and program your lntelliKnight system from up to
eight locations throughout your facility. The 5860 remote annunciator
provides the same advanced, easy-to-use interface found on the
lntelliKnight panel's built-in annunciator. The 8O-character display and
ergonomically designed keypad allow for simple and error-free system operation. All operations-including reset,
silence, detector status checking, fire drill, and programming-are identical.
Access to the system is through a firefighter's key or an access code. For security, a special installation code is
needed for programming functions. The 5860 connects to the lntelliKnight panel via the RS-485 system bus.
Wire runs can be up to 6000 feet from the panel.
For more information about the lntelliKnight system, or to locate your nearest source, please call
1-800-446-6444, or in Minnesota, call 763-493-6435.
Description
Features include an 80-characier
backlit LCD providing easy-to-
understand system messages. The
annunciator is ergonomically
designed with over-sized buttons
for the most frequently used
feaiures, like Reset and Silence.
ln addition to status messages
displayed on the LCD, there are
five LEDs for alarm, supervisory,
trouble, silence, and AC power
status.
The annunciator is available in gray
to match virtually any decor and
red for applications where the
annunciator must stand out. The
annunciator enclosure can be
surface or flush mounted. A trim
ring kit is available for surface
mounting.
Features. 80-character backlit LCD display
(4 lines with 20 characters on
each line)
. Tactile and audible feedback
. Accepts user codes or fire
flghter's key. Larger keypad buttons for system
reset and silence. lnstall up to eight 5860s per
FACP
. Available in red or light gray
. Support for simultaneous use of
multiple 5860s. RS-485 interface to panel
. Operation and appearance is
identical to 5860 built-in
annunciator
. On-board piezo sounder audibly
indicates alarms, troubles, and
supervisories. Five status LEDs for alarm,
supervisory trouble, silence and
AC power conditions
. Wiring lengths up to 6000 ft. from
the FACP (depending on wire
gauge and number of devices on
SBUS). UL listed, complies with NFPA 72
. CSFM approved
Electrical Specifications
Operating Voltage: 24 VDC
Standby Current: 20 mA max
Alarm Current: 25 mA
Wiring Distance: 6,000 max. from
FACP (depending on wire gauge
and number of devices on the
SBUS)
Max Per System: 8
Mechanical Specifications
Physical 9.1'W x7.4" H x 1.5" D
(23.1 Wx18.8Hx3.8Dcm)
Shipping Weight: 2.8 lbs (1.3 kg)
Color
5680R: Red
5680: Gray
Environmental
Operating Temperature'. 32oF -
1200F (ooc - 49oc)
Humidity: 10% - 93% non-
condensing
Approvats
NFPA 72; UL Listed;
CSFM 7'170-0559: 135;
MEA 429-92-E Vol. lX;
FM Approved
SIIENT
KNIGHT
by Honeywell
,I,NTELLIKNIGHTACCESSORY O O ao
5860 Remote Annunciator
Eng i neeri ng Spec ifications
The main control must have a built-in annunciator and must support up to eight remote annunciators. Remote
annunciators shall have the same control and display layout so as to match the appearance of the built.in
annunciator. Remote annunciators shall be available in two colors, red or light gray.
Remote annunciators shall have identical functionality and operation as the built-in annunciator. All annunciators
must have an B0-character LCD display and must feature five LEDs for: GeneralAlarm, Supervisory System
Trouble, System Silence, and System Power.
All controls and programming keys are silicone mechanical type with tactile and audible feedback. Keys have a
travel of .040 inches. No membrane style buttons will be permissible.
The annunciaior must be able to silence and reset alarms through the use of a code entered on the annunciator
keypad or by using a firefighter's key. The annunciator must have two levels of user codes that will limit the
operating system programming to authorized individuals. The control panel must allow all annunciators to
accommodate multiple user input simultaneously.
Wire Runa Up to 6000 fe€t From FACP
5860 58SC
lJp to Eight 5860s Per System
Compatible
5S6B
!&::::
Gompatibility
lntelliKnight 5820X1 FACP
lntelliKnight 5808 FACP
lntelliKnight 5700 FACP
Ordering lnformation
5680R Remote Annunciator
Four line LCD annunciator with 20
characters per line. Red.
5680 Remote Annunciator.
Four line LCD annunciator with 20
characters per line. Gray.
Accessories
5860TR Red Trim Ring
For sudace mounting.
5860TG Gray Trim Ring
For surface mounting.
SILENT
KNIGI'{T
This document is not intended to be used for installation purposes. We try to
keep our product information upto-date and accurate. We cannot cover all
specific applications or anticipate all requirements. All specifications are
subject to change without notice. For more information, contact Silent Knight
7550 Meridian Circle Suite 100, Maple Grove, MN 55369-4927.
Phone: (800) 328-0103, Fax: (763) 493-6475.
MADE IN AMERICA
FORM# 350224 Rev C, 05/06
Copyright @ 2006 Silent Knightby l"lnneywell
INTELLIKNIGHT ACCESSORYlr
Addressable
Photoelectric Type
Srnoke Detector
Detect smoldering fires quickly and get
help fast with lntelliKnight@ photoetectric
smoke detectors.
lnielliKnight addressable photoelectric smoke detectors are the clear choice for commercial settings where
smoldering flres are a threat. In addition to accurately detecting a smoldering fire, each SD505-APS
photoeleciric detector has a unique address, which is recognized by the lntelliKnight panel. No precious seconds
are wasted in determining location of an alarm.
The SD505-APS compensates automatically for contamination in the environment. And detector testing is
simple-even from a remote site. Like other lntelliKnight detector models, the SD505-APS offers a low profile for
pleasing aestheiics. The lntelliKnight family of deiectors has been designed to use a common base, Model
SD505-6A8, allowing complete application and placement flexibility. Combine all this with the features you've
come to expect from Silent Knight smoke detectors-easy installation, stable operation, RF/transient protection,
and vandal-resistant locking-and it adds up to a flexible solution for all your fire protection needs.
ModelSDS0S-APS
Analog / Addressable
Photoelectric Type
Smoke Detector
The SD505-APS is particularly
suited to detecting dense smoke
typical of fires involving materials
such as soft furnishings, plastic,
foam or other similar materials
which tend to smolder and produce
large visible particles.
The detector features automatic
compensation for contamination
and a simple detector calibration
test procedure that can be run from
the panelor remotely (using the
WindowsrM based downloading
software).
Operation
The SD505-APS units made up of
an LED light source and a silicon
photo diode receiving element. ln a
normal standby condition, the
receiving element receives no light
from the pulsing light source. ln the
event or fire, smoke enters the
detector and light is reflected from
the smoke particles to the receiving
element.
The light received is converted into
an electronic signal. Under normal
conditions, the status LED blinks
approximately every 15 seconds,
indicating that the head is
communicating with the loop. The
LED lights continuously during the
alarm period.
Features. Low profile, 2 inches, including
base. Simple and reliable addressing
without mechanical switches. Automatic compensation for
sensor contamination. Buillin fire test feature. Simple detector calibration
testing through the control panel
or remotely through a
Windowsrv based computer
software.. Vandal-resistance locking
features. Field cleanable. UL listed, meets NFPA 72 Ch7
requirements. CSFM approved. MEA approved. FM Approved
SD505-APS Smoke Detector
Specifications
Operating Voltage: 17-41 VDC
Current Consumption:
Standby: .55 mA
Alarm: .55 mA
Ambient Temperature: 32oF to 120oF
(OoC to 49oC)
Mounting 4" Square,4"
OCT, Single
gang mud ring
Relative Humidity:850
noncondensing
Air Velocity:0 - 300 FPM
CompatibleBases: SD505-6AB
(Sold Separaiely) (6" Base)
SD5O5-4AB
(4" Base)
SILENT
KNIGHT
by Honeywell
tNrELLlKNtcHrAccESSoRY I r to
Model SD505-APS
Addressable Photoelectric Type
Smoke Detector
Engineering Specifications
The contractor shall furnish and install where indicated on the plans, addressable photoelectric smoke detector
Silent Knight SD505-APS. The combination detector head, and twist-lock base, shall be ULo listed compatible
with Silent Knight's lntelliKnight fire control panels.
The base shall permit direct interchange with Silent Knight SD505-A|S lonization Smoke Detector, or SD505-
AHS Heat Detector. Base shall be the appropriate twist-lock base SD505-6A8.
The smoke detector shall have a flashing status LED for visual supervision. When the detector is actuated, the
flashing LED will latch on steady. The detector may be reset by actuating the control panel reset switch.
The calibration of the detector shall be capable of being selected and measured by the control panel without the
need for external test apparatus.
The vandal-resistant, security locking feature shall be used in those areas as indicated on the drawing. The
locking feature shall be field selectable as required.
The SD505-APS shall automatically perform a functional test of the detector. The test method shall simulate
effects of products of combustion in the chamber to ensure testing of detector circuits.
Diameler r 3-15116"
H*ight - 2 inches,
includi*g base
Model SD505-6AB Detector Base
(front view)
Model SD505-APS Detector Head
(front view)
1..*rt
lE-srn.rr=]ildlll'*"j
$ItENT
KNIGHT
This document is not intended to be used for installation purposes. We try to
keep our product information upto-date and accurate. We cannot cover all
specific applications or anticipate all requirements. All specifications are
subject to change without notice. For more information, contact Silent Knight
7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927.
Phone: (800) 328-0103, Fax: (763) 493-6475.
MADE IN AMERICA
FORM# 350225 Rev C,. 05/05
Copyright @ 2005 Silent Knightby Honeywetl
lo lo INTELLIKNIGHT ACCESSORY
SD500-PS and SDS0O-PSDA
Addressable Pull.Station
!ntelliKnight's addressable putl stations
combine fast response with pin-point
location ID.
The SD500-PS and SD5O0-PSDA are a single action or dual action addressable manual fire alarm pull station
for use with Silent Knight's lntelliKnight fire control panel. Extremely easy to operate, the SD500-PS/PSDA
provides a fast and practical means of manually initiating a fire alarm signal. The IntelliKnight panel recognizes
each manual pull station by its specific address saving precious seconds in determining the location of an alarm
The SDSOO-PS/PSDA mounts to a single gang box and features a rugged metal construction that lasts and
lasts.
Combine allthis with the features you've come to expect from Silent Knight - easy installation and stable
operation - and it adds up to a flexible solution for all your fire protection needs.
Model SD500-PS &
SDsOO.PSDA
Addressable Pull
Station
The SD500-PS is a single action
addressable fire pull station, and
the SDSO0-PSDA is a dual action
addressable fire pull station. The
SDSOO-PS/PSDA featu re rugged
metal construction A terminal strip
on back of the pull station allows
interconnection of the pull station to
the SLC of an lntelliKnight control
panel. The SDSO0-PS/PSDA is
designed for indoor use in non-
explosive environments. The
normally open initiating point
contacts are gold-plated to avoid
risk of corrosion. The SD500-
PS/PSDA has been tested by UL
for compliance to the requirements
of ihe Americans with Disabilities
ACT (ADA).
Features
. UL Listed
. CSFM listed
. ADA compliant
. Key reset (Same key as Silent
Knight enclosures)
. Surface mount back box
available
. Terminals - accept up to 14
gauge wire
. Extremely easy to operate
. Corrosion-resistant gold-plated
contacts.
. Reflective label makes it easier
to locate in low light
Operation
The SD500-PS/PSDA single action
pull stations are operated by a pull
on the front pull cover of the
station. A plunger switch, wired to
a self contained addressable
module, is released as the pull
station opens to initiate the alarm.
Once operated, the cover hangs
dswn and can be seen up to 100
feet away. The pull station is reset
by returning the front cover to the
normal upright position and
relocking the station wiih a reset
key. The reset keys are the same
keys used on Silent Knight
enclosures.
The SDS0O-PS/PSDA includes a
status LED which blinks, indicating
that the addressable module is
communicating with the loop. The
status LED lights continuously
during an alarm. A dip switch on
the addressable module is used to
set the unique address.
Specifications
Ooeratino Voltaoe: 24VDC
Standby Current:55mA
55mA
SD5OO.PS
Ambient Temperature: 32'F to 120'F
(0"C to a9'C)
Mounting: Single gang
box -
Opiional Red Suface Mount Box PS-SMBB
HNTfiHT
STTENT
Alarm Current:
Al*.tr.*iffi
]NTELLIKN IGHT ACCESSORY t ot
SDSOO-PS and SDSOO.PSDA
Addressable Pu I l-Station
Engineerin g Specif ications
Manual pull station shall be addressable Module SD500-PS/SD500-PSDA. Equipment shall be made of 14
gauge C.R.S.(Cold Rolled Steel), painted with a red enamel . The label shall contain the words Fire Alarm and
be made of a reflective material embossed text 3/8 inches tall. Operating instruction shall be clearly visible on
the same label. Manual station Shall contain a key operated test and reset lock using a lock plate actuator, the
key shall match the control panel.
Manual station shall contain four terminal blocks with two connected to the addressable module and two connect
to the SLC loop. Manual station shall provide data to the control panel with an lD address programmed by dip
switch settings .
Manual stations shall be Underwriters Laboratories lnc. lisied and installed within the limits defined in the
American Disabilities Act.
FJ4(JP
':*
*a
H
5IffilFi $tt , e&in€i!.(6-d.?rt{j Gtt;*$:liill 6i,i -
t-5il^
Wiring
Mounting to Single
Gang Electrical Box
Mounting to Optional
Surface Mount Box
SDsOO.PSDA
t l,{6-
lnstalling SD500-LK Dimensions
t-*--------i
(i!slric!! $ar Rillt h{
ri*at I'}n'Dcp
SiLENY
KHIGHY
;i !r; y:i* :rrrti$)i
7550 Meridian Circle, Maple Grove, MN 55369-4927
800'446-6444 or in Minnesota 763-493-6435
FAX: 763-493-6475
World Wide Web: http://www.silentknight.com
MADE IN AMERICA
FORM# 350342, Rev 09/03
Copyright @ 2003 Silent Knight
ot la INTELLIKNIGHT ACCESSORY
SDsOO-AIM & SD.sOO.MIM
Addressable I nput Mlodu les
lntelliKnight's addressable contact monitor
modules combine fast response with plnpoint
location lD. A combination that saves lives and
property.
The SD500-AlM and SD500-MlM are addressable input modules for use
with Silent Knight lntelliKnight fire alarm control panels (FACP). The
SD500-A|M and SD500-MlM are designed to be used with pull stations,
water flow switches, and other applications requiring dry contact alarm initiation devices.
The SD500-A|M addressable input module mounts to a 4"-square box. The SD500-MlM mini input module fits
inside a single gang box. The modules are supervised, single input contact monitors. Using an EOL resister,
they monitor for alarm contact closures and for open circuit wiring fault conditions.
The SD500-A|M and SD500-MlM offer a compact design for adaptability and pleasing aesthetics as well as easy
installation and stable operation-a flexible solution for all your fire protection needs.
For more information about the lntelliKnight system, or to locate your nearest source, please call
1-800-446-6444, or in Minnesota, call 763-493-6435.
Description
The SD500-A|M and SD500-MlM are
addressable input modules for use with
the lntelliknight fire alarm control
panels (FACPS). The SD500-A|M
addressable input module mounts to a
4"-square box. The SD500-MlM mini
input module fiis inside a single gang
box. Both input modules are designed
to be used with pull stations, water flow
switches, and other applications
requiring dry contact alarm initiation
devices.
These modules are supervised, single
input contact moniiors. Using an EOL
resistor, they monitor for alarm contact
closures and for open circuit wiring
fault conditions. lf a fault occurs in the
wiring, the module alerts the FACP.
Each addressable input module is
programmed with a unique signal line
circuit (SLC) loop address.
Features. Single contact monitor
. Support for Class A (Style 6 & Style
7) or Class B (Style 4) wiring
. Attractive ivory cover plate with the
SD5OO-AIM
. Small and lightweight size allows for
flexible mounting options with the
SDsOO-MIM
. DIP switch programmable for fast
installation
. Up to 2500 ft wiring distance from
either input module to contact
. Use up to 14 gauge wire
. UL listed
Electrical Specifications
Standby Current: 0.55 mA
Alarm Current: 23 mA max for one
device; 46 mA max for two devices;
0.55 mA for each additional device
Line Resistance: 50Q max
Mechanical Specifications
SD500-AlM Physical Description
Dimensions:
4.9.Wx4.9"Hx1"D
(12.4Wx 12.4 Hx2.5Dcm)
Weight: 3.6 oz (120.1 g)
Color: lvory cover plate
SD500-MlM Physical Description
Dimensions:
1.5"Wx2.5"Hx0.7"D
(3.8 W x 6.4 H x'1.8 D cm)
Weight: 1.6 oz (45.4 g)
Environmental
Operating Temperature:
32oF - 120oF (0"C - 49"C)
Humidity:
10% - 93'/" non-condensing
Approvals
NFPA71 & NFPA72
UL 864
CSFM 7300-0559: 132
MEA 429-92-E Vol. lX
FM Approved for use with the 5820XL
SILENT
KNIGHT
$ c'H
ffi'mc"ff# girtr#ll*""
SDSOO.AIM
ffi%
SDSOO.MIM
by Honeywell
INTELLIKNIGHT ACCESSORY t oa
SDSOO.AIM & SD5OO-MIM
Addressable lnput Modules
Eng i neeri ng Spec ifications
The contractor shall furnish and install where indicated on the plans, addressable input modules Silent Knight
SD500-AIM or SD500-MlM. The modules shall be UL listed and compatible with Silent Knight's lntelliKnight
FACPS.
The SD500-M|M shallfit inside a single gang electrical box. The SD500-A|M shall be supplied with a plastic
cover and shall be suitable for mounting to a 4"-square or double gang electrical box. The SD500-A|M
addressable input module must provide a monitor LED that is visible from outside the cover plate
#
ilffiIt tsffl*d{
i4b$ ftriaSF*
Arl tiliifind i$.$speryk6d
9ffi6f Liddlsd
{,:trfal
4'@
r#
ilffitLk#
T0 sntsct
ttsiog rutrqi
dill
i-i $,
liq
Compatibility
lntelliKnight 5820 FACP
lntelliKnight 5808 FACP
lntelliKnighi 5700 FACP
Ordering lnformation
SD500-AlM lnput Module
Addressable input module with ivory
cover plate.
SD500-M|M Mini lnput Module
Addressable mini input module.
SILENT
KNIGHT
This document is not intended io be used for installation purposes. We try to
keep our product information upto-date and accurate. We cannot cover all
specific applications or anticipate all requirements. All specifications are
subject to change without notice. For more information, contact Silent Knighi
7550 Meridian Circle Suite 100, Maple Grove, Mn 55369-4927.
Phone: (800) 328-0103, Fax: (763) 493-6475.
MADE IN AMERICA
FORM# 350231 Rev.C, 05/06
Copyright @ 2006 Silent Knightby Honeywell
I INTELLI KNIGHT ACCESSORY
IUlodel SD500-ARM
Addressable Relcy Module
PlEce reloy upplicctions $nywhere on the
lntelliKnight loop with the SD500'ARM
Addressqble Reloy lVlodule.
The SD500-ARM is an addressable device that adds great flexibility to the lntelliKnight system.
Providing two Form C contacts rated at 2.0 amps @ 30 VDC or .6 amp @ 120 VAC. The SD500-ARM
allows you to control a wide variety of normally open and normally closed applications, including
elevator recall, door closing, fan operation, and auxiliary notification. And, because the relay module is
addressable, these applications can be located at any point in the signaling line circuit.
Like other tntelliKnight SLC devices, the SD500-ARM is compact for adaptability and pleasing
aesthetics. Combine this with the features you've come to expect from Sileni Knight fire protection
devices-easy installation and stable operation-and it adds up to a flexible solution for all your fire
protection needs.
ModelSD500-ARM
Addressoble Reluy Module
The SD500-ARM provides two
Form C contacts rated at 2A @
30 VDC or .6,4 @ 120 VAC.
These contacts can be used for
virtually any normally open or
normally closed application.
0perolion
Each relay module is
programmed with a unique SLC
loop address. When an event
ihat controls the relay module
occurs, the relay is triggered by
the lntelliKnight panel.
Feotures
Two sets of Form C contacts.
Contacts are rated at 2A @ 30
VDC or .6A @ 120 VAC.
Up to 127 relays can be used on
each SLC loop.
Relay programming is
completely fl exible-can be
mapped to zone conditions.
Polling LED visible through
cover plate.
UL listed, complies with NFPA
72.
CSFM approved
MEA Approved, 429-92-E, Vol. 9
FM approved
SILENT
KNIGHT
Model SDSOO-ARM
r1
'I .i
Specificolions
Contact Rating:Form C
24 @ 30 vDC
.6A @ 120 vAC
Siandby Current:
Alarm Current:
.55 mA
.55 mA
Ambient
Temperature
32oF to 120oF
(OoC to 49"C)
Mounting 4-square electrical box
.!NTETLIKNI GHT ACCESSORY I o
llodel SD5OO-ARil
Addressqble Relcy lf,odule
Engineering Specif icctions
The contractor shall furnish and install where indicated on the plans, addressable relay
modules, Silent Knight SD500-ARM. The modules shall be UL listed compatible with Silent
Knight's lntelliknight FACPS.
The relay module must provide two Form C dry contacts rated at 2.0 amps at 30 VDC or .6
amp at 120 VAC.
The relay module must be suitable for mounting'in a standard 4-square electrical box and
must include a plastic cover plate. The relay module board must provide an LED that is
visible from the outside of the cover plate.
The relay must be fully programmable for such applications as are required by the
installation.
FRONT VIEW
i'::l: :;
SIITNT
XNIGHT
€i
4-718"1t4',
aa
1
lllodel SD500-ARI|I Addressqble Reloy ttodule Dimensions
SILENT
KNIGHT
7550 Meridian Circle, Maple Grove, MN 55369-4927
800-446.6444 or in Minnesota 763-493-6435
FAX: 763-493-6475
World Wide Web: http://wwirv.silentknig ht. com
MADE IN AMERIGA
FORM# 3s0218, Rev. 11l01
Copyright @ 2001 Silent Knight
s: Svsrerwi$ Sewson
Selectable Output
Horns, Strobes, and
Horn/Strobes
Spect rAl ert^ Adva n ce sel ectab I e- outp ut ho r n s, strob es,
and horn/strobes are rich with features guaranteed to
cut installation times and maximize profits.
The SpectrAlert Advance series of notification appliances is
designed to simpli{y installations, with features such as plug in
designs, instant feedback messages to ensure correct installation of
individual devices, and 1 1 field-selectable candela settings for wall
and celling strobes and horn/strobes.
When installing Advance products, flrst attach a unlversal mounting
plate to a four-inch square, four-inch octagon or double-gang
junction box. The two-vvire mounting plate attaclres to a single-gang
junction box.
Next, connect the notification appliance circuit wiring to the SEMS
terminals on the mounting plate.
Finally, attach the horn, strobe or horn/strobe to the mounting plate
by inserting the product's tabs in the mounting plate's grooves.The
device will rotate into position, locking the product's pins into the
mounting plate's terminals. The device will temporarily hold in place
with a catch until it is secured with a captured mounting screir.
The SpectrAlert Advance series includes outdoor notification
appliances. Outdoor strobes and horn/strobes (two r,vire anC four
wire) are available for wall or ceiling. Outdoor horns are available for
wall only. All System Sensor outdoor products are rated betr,veen
minus 40 degrees Fahrenheit and 151 degrees Fahrenheit in wet or
dry applications.
SPECTNfrrcruffi
Features
. Electrically compatible wlth existing SpectrAlert products
' Automatic selection of 12- or 24-volt operation at 15 and 15175
candela
.Plug-in design
. Field selectable candela settings on wall and ceiling units: 15,15/75,
30,75,95,1 10, 1 15, 1 35, 1 50, 177,185
.5ame mounting plate for wall- and ceiling-mount units
. Shorting spring on mounting plate for continuity check before
installation
. Tamper resistant construction
. Outdoor wall and ceiling products rated from -40'F to 151"F
. Design allows nrininral intrusion into the back box
. Horn rated at 88+ dbA at 1 6 volts
. Rotary switch for horn tone and three riolume selections
. Outdoor products UL listed to UL 1638 (strobe) and UL 464 (horn)
outdoor requirements
.Outdoor products rainproof per UL 50 (NEMA 3R)
.Compatible with MDL sync module
Listi
stct{AUt{G
MEA@
usTElr
5401 l
555t:
s:593
approved
))
i:i
tr
e:
i-a
I
APPROVED
302157:lr'ltA4 5l-15-E
@
Tllitii:-1:l M (rndoor !rcbe5]
?llx!!6:llSi a.urdoor srobei)
7 ll5-14;5::rlg (horr/srob?t,
(hime/inobet
7l l5-l lis}lA9 ihoms, chines)
.}'-)
32'F to 1 20"F (0"C to 49"C)
SpectrAlert Advance Specifications
General
SpectrAlert Advance homs, strcbes and horn/strobes shall nrount to a siandard 4 x 4.x 1rlz-inch back box, 4-incir octagon back box or double-gang back
box.Tlvo-wire products shall also nrount to a single-gang 2 x 4 x 1%-inch back box. A unhrersal mountinq plate shall be used for mounting ceiling and wall
used with rhe -sync.Circuit lviodule, 1 2-volt rateci noiihcation appliance circuit outputs shall operate between nine and 'l 7.5 volts; 24-vclt rated notincaticn
appliance circuit outputs shall operate between 1 7 and 33 volts. lndoor SpectrAlert Advance products shall operate beiween 32 and 1 20 degrees Fahrenheit
75,95, 1 10, 1 t5,',] 35, 1 50, 1 77, 1 B5.
Strabe
The strobe shall be a Sysrem Sensor SpectrAlert Advance lr4odel
-
listeil to UL I 971 and shall be approved for frre prutecti\ie service.The strobe shali be
1 Hz over the sirobe! entire cperating voltage range.The strobe light shall consist of a xenon flaslr tube arrd associated lenslreflector s1,stent.
l-lorn/Strobe Combination
Tlre honr/strobe shall be a System Sensor SpectrAlert Advance Mocel _ ljsted to LjL 1 97 1 and UL 454 and shall be approved for fire protective service.
The horn/strobe shall be wired as a primary-signaling notilication appliance and comply wirh rhe Americans wiilr Disabilities Act requiremetrts for visible
signaling appliances, flashing at 1 Hz over the strobe's er'lthe operating voltage range,The strobe light slrall consist of a xenorr flash tube and associated
lens/reflector s),stem-The horn shall have three audibility oplion, unO urr option to s\ryitch between a temporal thtee-pattern and a non-temporal (continuous)
pattern.These options are set by a multiple position switch. On four-wire products, the strobre shall be powered inciependently of the sounder.The horn on
horn/strobe models shall operate on a coded or non-coded porarer supply.
O$td06r Products
SpectrAlen Advance outdoor horns, strobes and horn/strobes shall be listed for outdoor use by UL and shall operate between minus 40 degrees and 151
degrees Fahrenheit. The products slrall be listed for use \ /ith a Systern Sensor outdoor/weatherprcof back box with half inch and three-fourths inch conduit
entries.
Synchronization Module
The mocule shall be a System Sensor Sync.Circuit model MDL listed to UL 454 and shall be approved for fire protective service.The module shall synchronize
SpectrAlen strobes at 1Hz and horns at temporal three. Also, while operating the strobes, the module shall silence the horns on horn/strobe models over a
single pair of wires.The module shall nrount to a 4t%6 x 41tAaxZ1,/e-inch back box.The module shall also control two Style Y (class B) circuits or one Style Z
(class A) circuit.The rnodule shall synchronize multiple zones. Daisyr chaining two or more synchronization modules together will synchronize all the zones they
control.The module shall not on a coded power
Standard 0perati$ g Temperature
K Series Operating Ternperature -40"F to 1 5 1'F (-40t to 66"C)
Humidity Range 'I 0 to 93% non-condensing (indoor products)
Strobe Flash Rate 1 flash per second
f{crninal Voltage Requlated 'l2DC/FWR or regulated 74DC|rlNRl
Operating Voltage Range?8 to 17.5 V (1 2V nominal) or 16 to 33 V (24 nominal)
input terminal wire gauge 12to 18AWG
Ceiling mountdimensions {including lens}6.8"diameter x 2.5-hiqh (i 73.mm diameter x 64 mrn high)
Wall mount dimensions {including lens}5.61.x47W x2.5D (142 rnm Lx 119 mmW x 64 nlm D)
Horn dirnensions 5.61 x4.7'W x 1.3'D (142 mnrL x 119 mmW x 33 mrn D)
Wall-nrount back box skirt dimensions i*85-?, BBSW-2)5.9a x s.C'lV x 2.2'D (l5l mm L x 128 mmW x 56 ntm D)
Ceiling-mount back box ski* dimensions {BgSC-z, BBSCW-2)7.1'diameter x 2.25" hlgh (180 rnm diarneter x 57 mm high)
Wall-nrount weatherproof back box dimensions (5A-WBB)5.7-L x -q.1'!V x 2.0D (l 45 rnnr L x 1 30 mm W x 5l nrm D)
Csiling-mount weatherproof badk box dimensions {SA-WBBC)7.1"Ciameterx2.0-hiqh (180 mm diametc.rx5l mm hiqh)
Notes:
'1. Full \ttave Rectified (FWR) voliage is a non-regulated, time varying po\i/er source that is used on some pc\^/er supply and panel outcuts.
2. P S, PC, and SC prociucts r,vill operate ai 1 2 V nominal only for 15 and 15/75 cd.
AS5-0395-i!tl
1a
UL Current Draw Data
B-17.5 Volts i 6-33 Volts
FWR DC fWR Sound Fattern dB
8-17.5 Voltr '16-33 Volts
Candela DC DC FWR DC FWR
15*123 128 66 71 Ternporal High 57 55 69 75Standard
Candela Range 15/75* 112 148 77 ot Temporal Medium 44 49 58 69
30*NA NIA 94 96 Temporal Low 38 44 44 48
75"NA NA 158 153 Non-ternporal Hiqh 57 56 69 75
95"NA NA i81 176 Non-temporal fuledium 42 50 60 69
1',]0 NA NA 202 195 Non-temporal Low 41 44 50 50
115 NA i{A 210 205 Coded lligh 57 ss 69 75
135 NA NA 228 207 Coded Medium 44 )t 56 69High
Candela Range 150 NA 40 46 52 50NA2461)i Coded Low
177 NA NA 281 251
185 NA NA 286 258
8-17.5 Volts 1 6-33 Volts
DC lnput 15 15/75 15 15175 30 1E 95 110 115
Temporal High 137 147 79 90 176 194 212107 218
Temporal lr4edium 132 144 bv 80 97 182 201 210
Temporal Low 132 143 66 77 93 154 179 198 207
Non-temporal Fligh 141 152 91 100 '1 16 176 201 221 229
Non-temporal Medium 133 145 85 102 163 187 207 216
Non-temporal Low 131 144 68 79 96 t5b 182 201 210
FWR lnput
Temporal l-liqh 136 t55 88 97 112 168 190 210 718
Temporal li4edium 129 152 103 1607888 1U 202 206
Temporal Lornl 129 151 76 86 10'1 160 184 194 201
Non-temporal High 142 '161 'r03 112 126 181 203 221 229
Non-temporal lt4edium 134 155 85 95 110 166 189 208 216
Low 132
16-33 Volts
154 80 90 105
150 177 135 FWR lnput
tot 184 202 211
1 6-33 Volts
DC lnput 135 135 150 177 185
Temporal Hiqh 145 259 290 297 Temporal High 215 231 258 265
Temporal il4edium 235 253 288 297 Temporal Medium lno 7)1!250 258
Temporal Lotnr 232 251 26t 292 Temporal Low 207 221 248 256
Non-temporal High 255 270 303 309 Non-temporal Hiqh 233 248 )75 281
Non-temporal Medium 242 259 293 299 Non-temporal Medium 219 232 262 267
Non-temporal Lo\^i 1ao 254 291 295 Non-temporal Low 214 229 256 262
Candela Derating
For K series products used at low temperatures, listed candela
ratings must be reduced in accordance with this table.
Listed Candela Candela at -40'F
Horn Tones and Sound Output Data
8-17.5
voltj
1 6-33
Volts
24Volt Nominal
Switch
Position Sound Pattern dB
Revevberant Anechoic
DC FWR DC FWR DC FWR trC FWR
15
r15
'1s/75
30
75
95
I10
Do not use below 32"F
44
70
1r0
115
135
150
177
2 Temporal
1
Temporal High 78 78 84 84 88 88 99 .98
Tempoi'al Mediurn 74 74 80 80 86 86 96 96
4
Low 71 73 76 76 83 80 94 89
No1-temporal High 82 82 88 88 93 92 100 100
Non-temporal Mediurn 78 78 85 85 90 90 98 985
6 Non-ternporal Low 75 75 81 81 88 84 96 92
82 82 88 88 93 92 101 iOt7r Coded High
'r35
150
8t Coded Medium 78 78 85 85 90 90 97 98
9i Cocled Low 75 75 81 81 88 85 'o5 92
177
185 185
tsettings 7, B, and 9 are not available on 2-wire horn/strobe.
AC5{1395-001
'-)l
SpectrAlert Advance Dimensions
5.6"
Wall-mount hornlstrcbes
7.r'
Dia.
Wall back box skirt Ceiling back box skirt
SpectrAlert Advance O lnformation
Wallweatherproofbackbox (eilingweatherproofbackbox
Ceilinq Horn/Strobes (cont'd.)
{eiiing-mount horn/strobes
Dia.
Wall Horn/5trobes
ICI
oq
o
o
D
b
o o
o
o
b
q
o
o
P2R*1 2-urire Horn/Strobe, Standard cd+, Red PC2W*i 2-wire Horn/Strobe. Standard cd, White
P2RH. 2-urire Horn/Strobe, Hiqh cd, Red PC2WH.r 2-wire Horn/Strobe,cd,White
P2RK{ 2-wire Horn/Strobe, Standard cd, Red, Outdoor PC4R 4-wire Horn/Strobe,Standard cd, Red
P2RHK. 2-urire Horn/Strobe, Hiqh cd, Red, Outdoor PC-4RH 4-wire Horn/Strobe, High cd, Red
P2Vv. 2-rarire Horn/Strobe, Standard cd, White PC4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor
P2\,VH* 2-wire Horn/Strobe, Hiqh cd,White PC4RHK 4-wire Horn/Strobe, High cd, Red, Outdoor
P4R*4-urire HornAtrobe, Standard cd, Red PC4Vf 4-wire Horn/Strobe,Standard cd, White
P4RH{ 4-wire Horn/Strobe, High cd, Red PC4'V'I/H 4-wire Horn/Strobe, H h cd, White
P4RK 4-wire Horn/Strobe, Standard cd, Red, Outdoor Ceiling Strobes
P4RHK 4-urire Horn/Strobe, Hiqh cd, Red,Outdoor SCR-Strobe, Standard cd, Red
P4'v'V* 4-wire Horn,/Strobe, Standard cd, White C'DU*Strobe, Hiqh cd, Red
P4WH" 4-wire Horn/Strobe, High cd,White SCRK Strobe, Standard cd. Red, Cutdoor
Wall Strobes SCRHK Strobe, High cd, Red, Outdoor
5R*i Strobe, Standard cd, Red SC\,'V"t Svobe, Standard cd, White
SRH.' Strobe, High cd, Rcd SCVvH*i Strobe, High cd, White
SRK Strobe, Standard cd, Red, Outdoor Horns
SRHK Svobe, High cd, Red, Outdoor HR Horn, Red
5Wn Strobe, Standard cd, $/hite HRK Horn, Red, Outdoor
S\ /H" Strobe, High cd, White HW Horn, White
Ceiling Horn/Stobes Accessories
PC2R* 2-wire Horn,/5irobe, Standard cd, Red DD)-Z Back Box Skirt, Wall, Red
PC2RH* 2-wire Horn/Strobe, High cd, Red BBSW-2 Back Box Skirt, Wall, White
PC2RK 2-urire HornAtrobe, Standard cd, Red, Outdoor BBSC-2 Back Box Skirt, Ceiling, Red
PC2RHK 2-v.rire Horn/Sirobe, High cd, Red, Outdoor BBSCW-2 tiack Box Skirt, Ceiling, White
Not6s:
" Add'rP"to model number for plain housing (no "FIRE'nrarkirrg on cover), e.9.. P2R-P
1 Add'-SP-to model numl:er for "FUEGO" markino cn cover, e.g., P2R-SP
*"Standardcd,'referstostrobesthatincluclel5,15/75,30,75,95,110,and115candelasettings.'llighccli'referstostrobesthatincltrdel35,l50,lTT,ancll85
candela sertirrgs.
All oirtdoor urrits ending in "Kinclude a s/eatherplooiback box.
3825 Ohio Avenue. S'., Charles, lL 60174a+ -r Swsrgtwt;*v Sewsoa"Phone: 800-5ENSORZ. i av,: 630-377 -6495
O:,ma rvrrinr Sflrscr.
Produc sir€cfrcaion3 suEea tc (hange ti:houi non.e v5[ asiemsensorco4r ior
cJxsl prcdJil iiiofiErjo[ induding*re |tlsl le{i3il ciilisdal3 silel
405-0395{10t. 1246'{1676
?*
S
AUDIBL 'SIBLE 'V
tlt F I c A r t o,v
Minl-AIert'*
Sounders
Susrerw
SENSoR'
Mini-Alert Sounders
Red
PA4OO
PA4OOR-F
EeigeWhite
PA4OO
PA4OOB-F
PA4OOW
PA4OOW-F
Product Overview
AZ end 24V operation
l-,S cd asldon strobe available
Mini-Alert Sounder Specifications
g effi@u':F
$ystem $ensor's Mini.Alert sounders ard sounder/strobes are suited to provide
prirnary asid secondary sigftaling for fire and seeurlty applicatio*s.
System Sensor's PA400 Series \4ini-Alert sounders operate at 24 volts ancl are
ideal for hotel, motel or residential fire system applications, where a smaller
notification device is desired. The PA400 sounders are available with or with-
out FIRE identification and are offered in red, beige, and white.
Engineering Specifications
Mini-Alert Sounders shall be a System Sensor \4odel
-
63p4!lg of operating at
24VDC. Sounder shall be listed to Underrvriter's Laboratories Srandard UL464
for fire protective signaling systems. Sounder shall have an operating tempera-
ture betq'een 14"F and 140"F.
Qt/2tt y 23/atty !7/e't
Weight
2.4 oz. (159 g)lirirul. T--!'nrirals
12 to 18 AWG0perating V.ritage
24VDC FWR unfillered*
*Actual 24V operating voltage cannot be less than 18VDC or greater than 33VDC.
Ordering lnformation/Current Draw
tieC White
PA4OOR
PA4OOR-F PA40OB.F PA40OW-F
Dirnen s ion s
*! Sound output varies depending upon voltage and sound selected.
System Sensor Sales and Service
MauntingSurface Single gang back boxFlush 4" x 4" BBD deep back box (23lr"deep)
(iperat:ng Tenrpera:ure iiange
14" to 140"F (-10'to 60"C)
tulax. Operating
Crirroilt @ 12V
i\4ax. Qpcraiini)
Curferit @-1 24V
47.4 mAMini-Alert sounder ("FlRE" identification)a2/24VDC 20.8 mA 82
l\4in!Alert sounder 24VDC nrA 47
System Sensor Headquarters
3825 Ohio Avenue
St. Charles, lL 60174
Ph: 800/SENSOR2
Fx:630/377-6495
www.systemsensor.com
System Sensor Canada
Ph:905.812.0767
Fx: 905.812.0771
System Senso! Europe
Ph:44.1403.891920
Fx: 44.1403.89r92L
System Sensor in China
Ph: 86.29.8832.0119
Fx: 86.29.8832.5110
System Sensor in Singapore
Ph: 65.6273.2230
Fx: 65.6273.2610
System Sensor - Far East
Ph: 85.22.191-9003
Fx:85.22.736.6580
System Sensor - Australia
Ph: 613.54.28]-.142
Fx: 673.54.28L.172
System Sensor - lndia
P n: 97.1,24.637 .L7 7 O x.27 0O
Fx: 91.124.637.3118
System Sensor - Russia
Ph: 70.95.937.7982
Fx:70.95.937.7983
02004 System Sensor. The company reserves the right to change product specifications without notice.A05034G001.5/04.#1213
t 1, /\
Rechargeable Sealed Lead-Acid Battery
PS-12120
12Yolt 12.0 Amp. Hrs.
Features:
o Absorbent Glass Mat (AGM) technology for
superior performance.o Valve regulated, spill proof construction
allows safe operation in any position.
o Power/volume ratio yielding unrivaled
energy density.. Rugged ABS plastic case and cover. Approved fortransport by air. D.O.T., l.A.T.A.,
F.A.A. and C.A.B. certified.o U.L. recognized underfile number MH 20845.
ffi
PERFORMANGE SPECIFICAT]ONS
Nominal Capacity
Approximate Wei9ht............ .....................j........ 8.5 pounds (3.86 kg)
Energy DensitSr (20 hour rate)..'1.69 Watt-hours/cubic inch (1 03.6 Watt.hours/l)
36 amperes
120 amperesMaximum Short.Duration Discharge Current ( S 10 Sec.)...
Terminal configurations ......,..-.."F2": Quick disconnect tabs, 0.250" x 0.032'- Mate with AMp INC FASTON "250" series
Shelf Life - % of nominal capacity at 68. F (20" C)
Operating Temperature Range
N
5'C
- (41"F)-
40'c
.(104"F)_
30'c
_ (86"F)
20"c
- (68"F)-
I
TECHNICAL DATA:PS-12120
40"c (1fi'F)
20ec (68eF)
0"c (szeF)
Shelf Life and Storage
100
ne€ssary unless
100%of capacity
before
use is,ne€ssary
to help remver
full
Do nol
reacfl
0 2 4 6 8 1012 14161820
Standing Period (Months)
Life Characteristics in Stand-By Use
Ambient Temperature 20:C
ttrl
Float Charging Voltage
2.25 -2.30Vlgell
2 3
Years
Ltfe Characteristics in Cyclic Use
0 200 400 600 800 1000 1200
Number of Cycles
CIjARGING
Cycle Applications: Limit initial current to 3.64. Charge until battery
voltage (under charge) reaches 14.40 to 14.70 volis at 680F (20oC). Hold
at14.40to14.70 volts until cunentdrops to approximately 120mA. Baftery
is fully charged under these conditions, and charger should either be
disconnected orswitched to "float" voltage.
"Float" or "Stand-By" Service: Hold battery across constant voltage
source of 1 3.50 to 13.80 volts continuously. When held at this voltage,
the battery will seek its own current level and maintain itself in a fully
charged condition.
NOTE: Due to the self-discharge characteristics of this type of batiery it
is imperative thatthey be charged after 6-9 monihs of storage, otherwise
permanent loss of capacity might occur as a result of sulfation.FgffiWffi
SALES & MARKETING
3106 Spring Street
Redwood City, CA 94063 USA
Tel: 650-364-5001 Fax: 650-366-3662
n ati o n a I -sa I es@ powe r-so n i c. com
Discharge Characteristics
Ambient Temperature 20"C {68"F
\A
6A
2.44
Final
Voltage 1"
t4A
't.2 2.4 6 12 24 36481 2 4 6 810 20 40
min.-*-- hrs.
Discharge Time
Discharge Time vs. Discharge Catent
(v)
14.0is not
13.0
$ tz.o
E
s 11.0
E ro.o
Eb e.oF
8.0
80
60
40
0
s
o
6u
o
o
oE
=or!o.
Go
00
80
60
40
20
1s
=o(!
(Eo
o
o
ox.
120
^ 100
E
F80(,
(g
o-l!60(J
€40
o
&. 20
20
15
10
5
P.t1
Iol.E)k 1Flo{.
PE:o
o
.9o
10
410
0.6 1.2 2.4 6 12 24
Discharge Current (A)
Physical Dimensions: in. (mm)
@
Terminals: F2 (mm)
T
j
1,,
PoraEE Eiifrir.
\g MOOEL PS-12120 F2
'#p,;
5.e5 (t5l)------+]
:-0.8
T I5
=
Fi
III
Tolerances are +/- 0,04 in. (+/- I mm) and +/. 0.08 in. (+/- 2mm) for height dimensions.
All data subject to change without notice.
ffi ISO 9001-2000
FM39170
CUSTOMERSERVICE
7550 Panasonic Way
San Diego, CA 92154 USA
Tel: 619.661.2030 Fax: 619-661-3648
c u sto m e r-s e rv i c e @p owe r-s o n i c. co m
\
10.5V
ge
,.*];\
9.r \
l' '3'0v*--8
Discharge
Depth 100%
I
uFcnarge
Depth 50%
I
Dlscharge
Depth 30%
3. Ambient Temperature: 20"C to 25'C (68'F to 77'F)
1. Discharge Current 0,2C
2. Charge Current: 0.1 C
PRINTED IN T] S A
www.power-son ic.com
11t04 1M
BUSINESS LICENSE
The person, firm or corporation named below, whose residence or place of business is
located as shown, having this day paid all required fees, is hereby granted license to
engage in the business, profession, occupation, trade, or exhibition named, in the City of
Port Townsend, for the period Townsend, for the period indicated.
BUSINESS NAME: Techna Systems, lne
BUSINESS LOCATION: 5205 S 2nd Ave
Everett, WA 98203
TECHNA SYSTEMS, INC
5205 S 2ND AVE
EVEREfi, WA 98203
POST IN A CONSPICUOUS PI-ACE AT BUSINESS LOCATION
CITY UF PORT TOWNSEND
250 Madison Street, Suite 1
Port Townsend, Washington 98368
Business License Number: 007{45
Date lssued: August 08, 2007
Expiration Date: December 31,2007
?1ttilael
NOT TRANSFERABLE
Receipt Nunber:
BLD07-165
BLD07-165
8LD07.165
BLD07-165
BLD07-165
989704106
989704106
989704106
s89704106
989704106
$210.50
$6.20
$4.50
$310.00
$to.oo
Total
$210.50
$6.20
$4.50
$310.00
$10.00
$0.00
$o.oo
$0.00
$0.00
$0.00
Plan Review Fee
Technology Fee for Building Permit
State Building Code Gouncil Fee
Building Permit Fee
Record Retention Fee for Building P
$541.20
HECKG 13752 $ 541.20
Total $541.20
genprntrreceipts l%ge 1 of 1