Loading...
HomeMy WebLinkAboutBLD05-238Waterman & Katz Building l8l Quincy Street, Suite 301 Port Townsend, WA 98368 Phone: (360) 344-3057 Fax: (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLD05 -238 Issued: 12120105 Parcel Number: 989 700 807 Job Address: 106 Tavlor Street Zoning: C-III Bldg. Type: V-N Occupancy:l!! Nature of Work: Construct strip footings. cribbing and iackscrews. and protective fencing to temporarilv stabilize and sunport the Surf Restaurant building Owners: Hastings Estate Company, Inc. Contractor: Affordable Services AFFORS*06503 Haruy Dudley 301-5488 Jay Ketchum 360-477-2646 Contact: Dave Clevenger 732-0477 GENERAL CONDITIONS APPLY - SEE LAST PAGE SEPARATE PERMITS REOUIRED: Electrical - Contact Labor & Industries @360-417-2702 WDF&W HPA Control #103679-l Shoreline Permit Exemption #LUP 05-129 NOTE: Weekly inspections shall be conducted of the temporary cribbing by a structural engineer to ensure the continued structural integrity of the temporary shoring. Inspection reports shall be submitted to the City for review. RE INSPECTIONS VED/DATE Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 3 RIGHTS-OF.WAY & TIDAL WATERS Any damage to rights-of-way caused by contractor during the course of construction, loading, staging, etc. shall be restored to pre-existing, or better, condition at contractor's expense. Storage of materials in City rights-of-way or on the beach is prohibited at all times without prior permission/permits from the City. No equipment shall be operated on the beach. NOTICE OF ACTIVITY The applicant shall be responsible for notifuing all neighboring businesses ond/or residents of the scope and timing of the approved and pending work andfor securing ony necessary rights-of-access acros s intervening properties Pemit # BLD05-238 UIRED S APPR GENERAL CONDITTONS 1. Contractors working on this project are required to have a Labor & Industries contractor's resistration number and a Citv business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished" 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. Call48 hours before you dig for utility line locates 1-800-424-5555 Page2of 3 iPlrc't't()v l,DtDA'l't STRIP FOOTINGS - minimum 4,000 psi concrete is required; no special inspection is required per David Pierce, engineer of record, but contractor shall provide written verification of high strength concrete mix at time of pour Forms - minimum 10" deep per engineered design Lining -forms shall be linedwith material to prevent direct contact of the concrete with shoreline bed Reinforcement- grade 60; #5 @ 12" o.c. eachway TOWER CRIBBING Positive Connections - red head expansion anchors are proposed; engineer to specifu anchor length; stampings on the exposed end shall be preserved to provide for subsequent embedment v e r ifi c a t i o n ; ins t al I p e r m anufa c tur er' s ins t all at i o n ins tr uc t i o n s using carbide tipped hammer drill bits. FENCING Details for the plastic fencing including scope of work, means of installation, timing, etc. shall be submitted to the City for review and approval a minimum of 48 hours prior to beginning the proposed work FINAL Weekly inspection reports by structural engineer shall be copied to the City. The temporaryfootings shqll be removedfrom the beach and disposed of upland to prevent re-entry into State waters within one year ofplacement. 'a Pemit # 8LD05.238 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call385-2294. A minimum of twentv-four hours notice is reoui Public Works annroval must be received nrior to schedulins the Buildins Departmbntos final insnection. 7. final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department Q79-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON.SITE WITH THE APPROVED PLANS. Applicant Signature Date Call48 hours before you dig for utility line locates r-800-424-5s55 Page 3 of 3 CITY OF PORT TOWNSEND PERMIT ACTIVITY LOG PERMIT # 6 - z5g SCOPE t- DATERECEIVED: lZ - I 5 - Os JMN t2-t5 Entered into TRIPS 5FESA-to Planning -no evidence of ESA- Vested Date Checked for Completeness 17-. \\Bcdjermits\forms\BUllDlNG\permit Activity Log. doc