Loading...
HomeMy WebLinkAboutBLD08-014nr rty BUILDING PERMIT City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Projectlnformation Permit# BLD08-014 Permit Type Residential - Single Family - New Project Name WADE VAUGHN Site Address 1977 EDDY STREET Parcel # 944700101 Project Description New SFR at corner of Howard/20th, access from Wade Vaughn Ave Names Associated with this Project License Type Name Contact Phone # Type License # Exp Date Applicant Tierra Investments Llc Owner Tierra Investments Llc Contractor Reality Homes Inc Jared Baeher (253) 926-6822 CITY 5102 12/31/2008 Contractor Reality Homes Inc Jared Baehmer (253) 926-6822 STATE REALIH1984CI02/15/2010 Z. —75 2 011 J * * * SEE ATTACHED CONDITIONS * * * Call 385-,2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of X80 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true a ,d accurate to the best of any knowledge. I further certify that i am the owner of the property or authorized agent of the owner, Print Name Date Issued: 02/22/2008 �r Issued By: SFOSTER Project Information BUILDING I ING ERMI " City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Permit Type Residential - Single Family - New Site Address 1977 EDDY STREET Project Description Permit # BLD08-014 Project Name WADE VAUGHN Parcel # 944700101 New SFR at corner of Howard/20th, access from Wade Vaughn Ave Names Associated with this Project Type Name Contact Applicant Tierra Investments Llc Owner Tierra Investments Llc Contractor Reality Homes Inc Jared Baehmer Contractor Reality Homes Inc Jared Baehmer License Phone # Type License # Exp Date (253) 926-6822 CITY 5102 12/31/2008 (253) 926-6822 STATE REALIHI984CI02/15/2010 * * * SEE ATTACHED CONDITIONS * * * Call 385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify that I am the owner of the property or authorized agent of the owner. Print Name Date Issued: 02/22/2008 Issued By: SFOSTER BUILD- NG PERMIT City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Project Information Permit # BLD08-014 Permit Type Residential - Single Family - New Project Name WADE VAUGHN Site Address 1977 EDDY STREET Parcel # 944700101 Project Description New SFR at corner of Howard/20th, access from Wade Vaughn Ave Fee Information Project Details Dwellings — Type V Wood Frame Project Valuation $181,177.16 Private Garages— Wood Frame Site Address Fee 3.00 Building Permit Fee 1,452.95 Energy Code Fee - New Single 100.00 Family Unit Mechanical Permit Fee per Dwelling 150.00 Unit - New Residential Plan Review Fee 944.42 Plumbing Permit Fee per Dwelling 150.00 Unit - New Residential State Building Code Council Fee 4.50 Technology Fee for Building Permit 29.06 Record Retention Fee for Building 10.00 Permit Total Fees $2,843.93 1,788 SQFT 440 SQFT Call 385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify that I am the owner of the property or authorized agent of the owner. Print Name Date Issued: 02/22/2008 Issued By: SFOSTER BUILDING PERMIS" City of Port Townsend W. Development Services Department AWA . 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Project information Permit # BLD08-014 Permit Type Residential - Single Family - New Project Name WADE VAUGHN Site Address 1977 EDDY STREET Parcel # 944700101 Project Description New SFR at corner of Howard/20th, access from Wade Vaughn Ave Conditions 10. Property corner survey pins must be located at time of f000ting inspection to verify setbacks. 20. Temp. erosion control measures must be installed and maintained prior to approval of any building inspections. 30. Street and ultility improvements must be installed and approved prior to final occupancy. Call 385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify that I am the owner of the property or authorized agent of the owner. Print Name Date Issued. 02/22/2008 Issued By: SFOSTER CITY OF PORT TOWNSEND PERMIT ACTIVITY LOG PERMIT SCOPE OF WORK: DATE RECEIVED LL LL O ❑w W H Z Cl)0 caO Fn ❑ W Z = Q W Z Z no Q W w J Q J wa r••� °O o 'a U m 00 WIL F - z Z Q Z� 3 WZ Z ❑ a LU a G� C W W J > o Q a J a L zQ O D ❑ „� a+ w a I' M 0 Q Q Lu U F- 0 O z O O y Z � ❑ > O a. a. U LQ N z0 � z ao J OJ m CO w O F=- U Z V z O � 00 W = Q r� Q Q W F - z Q 40 �a a c w 0 m W L O O N O (E 00 Q O 0 >E Z O Q LU CL a) pU o U Z N O O N m -O ' M x W O 2 0 LU W O C) U Z N 0 (6 N V LL N U) 0 Z Z O w U cl O Q J ❑ 0- 0 - � LU W Of D U co w c ❑ U it 0 - co co 0 J m 0 0 O �I v�O O Z J W Q a U J J U) W z Of 2 U) U) i > ❑ Z w Q cr) W w F-' w LU W Z Q O U _Z U) w 2i O S I ~ w Q. O F- 9 F - Z O U z w O U z O U W a z U) z LU O U w a ❑ IL CO z Z O F- U W a N Z Q X� W N O oo LL CO) �a vo 0 J M QO U F - Z M 02 ~a U Wp IL Cl)> ?w Z U Q w F- W U) m LU W D w E ON LU C'! LU w z O F- U W IL Z I - > Applications accepted by mail must iV-1C-fade a check for,irvja14 plan )'eview fee of $15() > See the "Residential Building Permit ^PPlication Requirements,, for details on plan submittal requirements. ContactlReprese tta ive., Name:— (Z, Address: - Citylstlzip,—A-25��L414n,L. eop— 91`722,9 Phone: �17 Contractor: [""11 S me aOwner Name:--.— M,1" e-:5 Address: City/SVzip:— Phone � q7-1�— Coy?— Z— Email: re— 0( e4 State License #:ff A.�Jlkj City Business License #,, U1 e Port Townsend WA98365 Phone360-379-5o95 Faix� 360-344.4619 Wwwxjtyofotu"; Building Information (square feet): 1 sr floor I Garage: nd -4io- 4 floor Deck(s: .3rd floor Porch(es), Basernent:. Is it finished? Yes No Carport: Manufactured Home Other: --- ADU I New Addition T Remodel/Repair T Total Lot Co ver)a3g e *(Building Footpr int) Sq(mre feet: % ILmpervious Surface* quare feet:7 16Total existi- ,* aro edj An:yknow:nwetlands on the Property? y ,.)? Y Any ste:ep slopes (>Is%)? y I hereby certify that the information provided i's Correct, that I am either the and that all activities associated with thh�d"�a9r��" 'I owner 01" authorized to act on behalf of the owner I Mit Will be in accordance with State Laws'prid the Port Townsend Municipal Code, Print Name* flet.—e-al _T17 VMTS7�4ex4r LL(, Signature: Date: O"R CITY OF PORT TOWNSEND Building and Community Development BILLING STATEMENT" �la (Name) (Address) (Date) (Phone) $ REINSPECTION FEES R-2040 ❑ C-2041) (moi' $ (g) PLAN REVISION FEE (❑ R-2030 ❑ C-2031) ($50.00/hour, minimum $25.00) $ RESIDENTIAL T. C. 0. INSPECTION (R-2020) ($97.00) $ COMMERCIAL T. C. 0. INSPECTION (C-2021) ($147.00) $ SPECIAL INSPECTION (C ($47.00/hour, 1 hour minimw $ OTHER (❑ TOTAL DUE $ Revised 116100 NBcd permitslformslBILISTMT.doc (Permit Number- if applicable) REVISIONNUMBER: $ Revision Valuation $ Original Permit Valuation $ Total Valuation (a) $ Fees due based on Total Valuation (ate+c) (b) $ Building Permit Fee Message For ..- rrmssage rruu�rk�.Fti,.�'..,,,,�.. ��,�"� �.�-�,� ...'�"' P�. rTYC .,f-.... .�•�.- r awe .(.,1 t � C 5d best cal back turn, ...... day q _ "'VES r Building and Permit Fees THANK YOU! Page 1 of 1 Scottie Foster From: Scottie Foster Sent: Friday, February 15, 2008 9:24 AM To: 'tierrainvestments@yahoo.com' Subject: BLD & MIP PERMIT FEES DUE Attachments: 20080215091638.pdf Pete, I received your check for the two permits and the amount is incorrect. I do not know how I calculated that figure I gave you and I apologize. Attached are two invoices. One for Bld08-014 and one for MIP08-007. The total amount due for the two permits that are ready to issue, and including the $5 for shipping the permits and plans to you should be: $2,764.93. On your direction, I can either destroy the old check or send it back to you. Again, I am sorry if this causes you any inconvenience. Scottie Foster Administrative Assistant Development Services Department 2/15/2008 City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Application No BLD08-014 Project: WADEVAUGHN Application Type Residential - Single Family - New Parcel # 944700101 Subdivision: COLUMBIA PARK Block/Lot Site Address: 1977 EDDY STREET Description Fee Amount Paid/Credit Balance Due Site Address Fee $3.00 WOO $3.00 Building Permit Fee $1452.95 $0,00 $1452.95 Energy Code Fee - New Single Family Unit $100.00 $0,00 $100.00 Mechanical Permit Fee per Dwelling Unit- $15000 WOO $150,00 New Residential Ran Review Fee $944.42 $150,00 $794.42 Plumbing Permit Fee per Dw elling Unit - $150,00 $0.00 $150,00 New Residential State Building Code Council Fee $4,50 $0.00 $4.50 Technology Fee for Building Permit $2906 $om $29.06 Record Retention Fee for Building Permit $10,00 $0.00 $10.00 Total Fee Amount: $2843,93 Total Paid/Credits: $15000 Balance Due: $2693.93 Payment due within 30 days Invoice Date: 15 -FEB -08 Invoice # 262 /X/ V'q, at/A .2 /') *2 7-9 4� DDS V 1zl, 4- a z, �G /� /) '0 I b p "r-' . 7 fly 7, City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 I MAJ W41 Will 0 141 Lai MUM M� Application No MIP08-007 Project: Wade Vaughn Application Type Minor Improvement Permit Parcel # $66.00 Subdivision: Block/Lot Site Address: 1977 EDDY STREET Description Fec Amount Minor Improvement Permit $100,00 SDC - Water $2522,00 SDP Inspection $66.00 SDC - Sewer $2331.00 Water Connection $135,00 Technology Fee for Minor Improvement $5,00 Permit $5.00 Record Retention Fee for Minor $500 Improvement Permit $0-00 Invoice Date:: 15 -FEB -08 Invoice 263 Paid/Credit Balance Due $100.00 $0.00 $000 $000 $2522.00 $66.00 $0.00 $2331,00 Loll $0.00 $135.00 $5.00 $0.00 F45. $5.00 $0-00 S7 —S () Total Fee Amount: $5164.00 Total Paid/Credits: $110.00 Balance Due: $5054.00 Payment due within 30 days Appl # 1i1)08-01 Date Issued Applicant IMMA DIMESTMnTTS LLC Typ e B LD - Mi - SF P. ...... .. ....... . . . . . . . ....... . Expiration Date M1612008 r . ............... . .... payrej # f944700 10 1 parent Re -issue Date f...... . . .... ....... . ....... Site Add ress I 7'1'-,7'DD Y STBE Fr Date Submitted �O I I Sr, -'008 Date Closed fioje .. .......... . . ........... ct N ante iADF VAUGIDT Techrdcaft Complete' Last Action hm4kg 1 R-11 Date Approved .... . ...... . . Status Date Status IPEIAI'Tin,3 Ove de Expire?[- Gov-Prmui[ent7f_ New Permit Query hint Forra Letters C" o py Site Address, I F Notes? s, to stn�6t Oultrrwtin ., " M n F . Ao"49"Utik Foe; Ov*etid A E D .used 04 Qmantity—, quau4�, � , :" I "', ejlire�>$ Urjf 1 . . . . ... ........... ..... . . .......... ... . $0 , 100 '),00 1, 1A 5,19 5 BPF -P511, 7 T Iv,alua6m, i's "'16 I M I' 81177,16 01,100 T 10" "0, 0 PF ­­­� ............. .. .. ... ....... . 1811­716� 181177W . ............. EVEP,G Y,STR ­­ sluo,�),D .. . ..... . .. .. . . ...... .. ... 0,00 DAECH.-IT. FEW -RES f"17 IfAwic $1 4) oo 000 $1 5­c','� oo r PI.M.-NEW.RS T- ':­­� ;'�­ xj . .. . .. ..... . ........ . ­­­­ . ..... . 00 1 5 O.Ool PPJF F, f, V- W a o ri 8,1177 16 . .. . . ..... . 181177,16 ii5om, $944142 Fee Descripti4nZat, tai fats ss Fee B150,00 8431913' C,twrent AdqvA,(.ash Receipts� flistoi AnalwatDuelf VP93 93 71 ", ( al �Oq �'o$ N YCypm, City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 TIERRA INVESTMENTS LLC 7327 SW BARNES ROAD#308 PORTLAND OR 97225 Application No MIPOB-007 Project: Wade Vaughn Application Type Minor Improvement Permit Parcel # $0.00 Subdivision: Bloc k/Lot Site Address: 1977 EDDY STREEr Invoice Date: 07 -FEB -08 Invoice # 251 Description Fee Amount Paid/Credit BWaance Due Minor Improvement Permit $100.00 $100.00 $0.00 SDC- Water $2522.00 $0.00 $'2522.00 SDP Inspection $66.00 $0.00 $66,00 SDC - Sewer $2331.00 $0.00 $2331,00 Water Connection $135.00 $0.00 $135,00 Technology Fee for Minor Improvement $5.00 $5.00 $0.00 Permit Record Retention Fee for Minor $5.00 $5.00 $0.00 Improvement Permit Total Fee Amount: $5164.00 Total Paid/Credits: $110.00 Balance Due: $5054.00 Payment due within 30 days Page 1 Aar t ) r 4A A'v W ,4 6L®.. 0P-"' O(rj v vv.^ - 6r - 47, Pe4 4L.- C4 d J, � 5-4�rl- / .. ofie, "ef � A., O'f i k-le� 1A, IA �U3 '18 2008 JAN COOF PUMTCIVVN�E­i'i-D DSD W Z W W a�� _ I z W c � L' i CMZ ti Om0 _ �V? dv�o (ZS 3D, w z o � w Q pp DIY QQ .-N r'�F--rtm V7 Q SL/ -7 N.13g d NVADND V�ds�Vg NOTE CIS 4,I a 7MH r�xxaaur°W 1 .,°la ""-a �} �- ��AI,Ztro88SR L A Y i a i 1 .......... Li Z w...¢ ru W Ji t r`I.wl%f V C.l� r-� 1 ' �, C� `,I�:..\ a .... .. _. _. hW.i.., (Y w _ CU II Vi rteoi -; C,.i I X a; tp 2 / �. �"'•� � _ � I !/ � \, V�y;r N � m i LLJ \ r ._. w W ._ ..� _ ,_. _., Y H to V) N o t LY - 1 3 ��Gtr '82R" S ✓ .r o� i Q r rmm. P W W ;o r T ; V o� air Iain zw "*✓ � i o I U �' � k �' _._. ._" _._,_. i ¢ p t1 - i �� to clu ----------- - c CD y flLn LLJ '��,.�4R I� v I Vl W F— • 8 �7 h-- i b i Y I 3 w dlS SSI>fc- C1 CT l 1 w o pR Cdr j. —�z z LJ Q z ti LLJ / I �zzwn Is R CL O UO W W" R i W W 6W 1 L.� �O�dz a z °N 1 0 z z r o o -i d I ( n, Q'_ W ]� Q W 3 :; F z z Ij U 1 d� ^'�pl �� <F-uVSOCL N g ml 1 L7 X31 NI/\3>1 w XI 0l ... Li WWI I t fC w U O R w �. P ,............. ._........�! -s SL'89t i P I co WER =0 3NI-I iHOli z 0 GPVMOH CY) U) < 0 (Y n ry 0 [if x 0 LL- zttz n U) z 0 GPVMOH A NONEXCLUSIVE LICENSE AGREEMENT Thank you for choosing Hodge Engineering Inc. for your engineering needs. Upon receipt of payment this engineering is licensed by Hodge Engineering Inc. to you the purchaser for your one time use only according to the terms set out below and by any additional agreements between you and Hodge Engineering Inc. Please read the following terms and conditions carefully and if you do not agree you should not use this engineering. By using the engineering herein for your structure, you agree to be bound by the terms listed below and in Hodge Engineering's service agreement. License - Hodge Engineering hereby agrees to grant you, upon receipt of payment and your acceptance of the terms of this agreement, a nonexclusive license to use the enclosed engineering, subject to the terms and restrictions as set out in this license agreement. Copyright - The material contained herein is copyrighted by Hodge Engineering Inc. You may not copy or otherwise reproduce the content or any portion thereof except as expressly provided by Hodge Engineering Inc. You may, however, make copies as required for your subcontractor's use provided that you reproduce all copyright notices and other proprietary legends on such copies. Restrictions on Use and Transfer - This engineering may only be used by the license purchaser in connection with a single site. You may not distribute copies of the engineering to others. The license may not be assigned, sublicensed or otherwise transferred by you without the prior written consent of Hodge Engineering Inc. Limited Warranty - Hodge Engineering will use the degree of care and skill ordinarily exercised for similar projects by members of the engineering profession in this area. No other warranty either expressed or implied is made in connection with the engineering or engineering services. For any dispute, claim, or action arising out of the engineering, Hodge Engineering shall have liability limited to the amount of the engineering fee. Defect — If any conflict or defect in this engineering is discovered the user must immediately notify Hodge Engineering Inc. so that it can be addressed. Except as expressly provided above Hodge Engineering makes no warranties either expressed or implied with respect to the engineering, or its fitness for a particular purpose. our use of this engineering acknowledges that you have read this nonexclusive license cement and agree to its terms. 4.24.2006 Hodge Engineering, Inc. .John E. Hodge P. E. 26oi Jahn Ave NW Ste. At Gig Harbor, WA 98 335 Oak'- (253) 857-7055 Fax (2 53) 857-7599 ow 4 r III 1.. WA A�NFhWMH P � � W uwd�Yl(afYi W1Vgp�, ^ ,. 7 mw'Wrp ; rye6�ma:� uw `� ww wwwt �r �'� "ro m ,+b1pw R.o&o: rmip�Nu�^m�m�u'.11sp Too ll� ,yy � ,nr y, Mirks ,r irr�m irk �rrMN 400 � i r rw tiro , ,fir r x N'pk9Nrn 9�PVa'.!r6KK' p �r 6d�A25�1 *4" qr M w x a,ym, rt,.l� 1�IY6XN n1+' url^k vrr N , a y; "" Ali oil rio n^aror c, J arW q+r r "y WW""�,,' ��' '°rc qui"# yt r' Icon c = , i� u¢ r w� � � � � � � �, � �FAYflnw�R � � r� �� d f "M r to r r IA Conterminous 48 States 2006 International Building Code Latitude = 48.114559 Longitude = -122.784549 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.298 (Ss, Site Class B) 1.0 0.473 (S1, Site Class B) Conterminous 48 States 2006 International Building Code Latitude = 48.114559 Longitude = -122.784549 Spectral Response Accelerations Ss and S1 Ss and S1 = Mapped Spectral Acceleration Values Site Class B - Fa = 1.0 ,Fv = 1.0 rm Data are based on a 0.05 deg grid spacing Period Sa (sec) (g) 0.2 1.298 (Ss, Site Class B) XXX 20th St. Port Townsend, WA 4of12 �_........ ........... ....... ..... 0WoodWorks@ Shearwalls SOFTWARE FOR WOOD DESIGN _-.................................... _...._. .... Lateral Analysis.wsw WoodWorks® Shearwalls 7.01 Jan. 9, 2008 12:41:14 Level 1 of 1 - -- - F . -a �- i M0 —52.1 82,11 � M0 5, NN �� ��.141l 9 / �i = - 14160" - a �......o.... - -- 320 1 ��,� � ,� �� , q � P v c U-1 �. �..., ' ,52.5' -- 50, ( ry _ i 45r 40 Cd ro5r v= 3.5 50, - 275 F _ t 3950 w '-1 Cj 102 22:5" } s tl 04 Cu 17.5' 165 . 0" " � - : e 730 All - �.. C & 117.4 y . _ �20, 80.5 �_80�8 � 53.5 53:5 53.5 20.0 7;5' 0" 12'.5" Fal ' fore (Gb�) ed" hol i for: (lbs) Qnfac ored�apped shear bad (ply Unfac,or S deadCoad (plf,lbs) 11 I i p, � G o cession fora exl Its"� f (p s)` .. Uplift �rirrd �+�f ' 'If„Ib' �. _0" rk I 4Ede ' d"1, Applied poi t load or force (lbs �' �F L•oadk” 1�1 .7,� 1 1 5 1 1 5 20 2 .5s 25127.5 3b' 3 3'5' 37.5'4* ¢ " 42,.5" 4;5" 47.5' S0' 5 .5' 3NX 20tH St. Port Townsend, WA 5of12 WoodWorks@ Shearwalls SOFTWARE FOR WOOD DESIGN Lateral Analysis.wsr WoodWorks® Shearwalis 7.01 Project Information Jan. 9, 2008 13:22:55 COMPANY AND PROJECT INFORMATION Company Project Hodge Engineering, Inc. 88013 GOUGHNOUR 2601 Jahn Ave. Ste. NW 1-A Exposure B Gig Harbor, WA 98335 Seismic Category D 253-857-7055 2006 IBC DESIGN SETTINGS Design Code Wind Standard Seismic Standard IBC ASCE 7 All heights ASCE 7 _..-..._ ....... _..._ ......... Wind Capacity Increase Load Combinations Building Code Capacity Reduction Shear C&C Panels 0.70 Seismic Wind Seismic 1.40 1.60 1.00 Wind 1.00 1.00 ............. - .............. _. _.... Nail Withdrawal Modification Max Shearwall Offset [ft] Duration Temperature Moisture Content Plan Elevation Factor Range Fabrication Service (within story) (between stories) 1.60 T<=100F Dry Dry 4.00 - �.. ._WWW......._ .-...._._ Maximum Height -to -width Ratio Plywood Fiberboard Lumber Gypsum Wind Seismic Wind Seismic Blocked Unblocked 3.5 3.5 Shearwall Relative Rigidity: Designed capacity using flexible distribution Hold-down Forces: Based on applied shearline force Seismic Materials: Ignore gypsum for exterior walls Case 2 rigid diaphragm load distribution: 75% loads, torsional moment SITE INFORMATION ...-......... m. ..... __ IBC Occupancy ASCE 7 Equivalent Category II - All others Category II - All others _._.. _ ._...... ...... Wind Seismic ASCE 7 General analytic method for all bldgs ASCE 7 Equivalent lateral force procedure Design Wind Speed 85mph Use Group I Exposure Exposure B Design Category D Enclosure Enclosed Site Profile Class D ......... Topographic Information [ft] Spectral Response Acceleration Shape Height Length S1:0.473g Ss:1.298g - _ Fundamental Period E -W N -S Site Location: - T Used 0.0883 0.0883 Approximate Ta 0.088s 0.088s Maximum T 0.105s 0.105s Response Factor R 6.50 6.50 XXX 20th St. Port Townsend, WA 6 of 12 WoodWorks® Shearwalls Lateral Analysismsr Jan. 9, 2008 13:22:55 Structural Data STORY INFORMATION Story Floor/Ceiling Wall Elev[ft] Depth in Hei httt Ceiling 10.83 0.0 v Level 2.83 10.0 8.00 Foundation 2.00 BLOCK and ROOF INFORMATION Block Rood Panels Dimensions IM Face T e Sloe Overhang Block 1 t Story N -S Ridge Location X,Y = 0.00 12,00 North Gable 90.0 1.00 Extent X,Y = 43.00 46.50 South Gable 90.0 1.00 Ridge X Location, Offset 21.50 0.00 East Side 30.0 1.00 Rid a Elevation, Height 23.25 12.41 West Side 30, 0 1.00 Block 2 1 Story N -S Ridge Location X,Y = 21.00 0.00 North Joined 90.0 1.00 Extent X,Y = 22.00 12.00 South Gable 90, 0 1.00 Ridge X Location, Offset 32.00 0.00 East Side 30.0 1.00 Ridge Elevation Height 17.18 6.35 West Side 30, 0 1.00 XXX 20th St. Port Townsend, WA 7of12 WoodWorks@ Shearwalls Lateral Analysis.wsr Jan. 9, 2008 13:22:55 MATERIALS WALL GROUP Wall Sheathing [in] Fasteners Spcg [in] Framing Members [in] Apply Grp Surf Material Thick Orient , Size T Ed g Fid I Blkq Scies G S Notes 1 Ext Struct Shthg 7/16 Vert 8d Nail 6 12 yes Hem -Fir 0.43 16 1,3 2 Ext Struct Shthg 7/16 Vert 8d Nail 4 12 yes Hem -Fir 0,43 16 1,2,3 Grp - Wall Design Group; Surf - Exterior or interior surface of exterior wait, Spcg - Edge or field nail spacing; BIkg - Blocked; G - Specific gravity, Spc - Wall stud spacing XXX 20th St. Port Townsend, WA 8 of 12 WoodWorks@ Shearwalls Lateral Analysis.wsr Jan. 9, 2008 13:22:55 SHEARLINE, WALL and OPENING DIMENSIONS North-South Type Wall Location Extent [ft] Length FHS Height Shearlines Group(s) X EM Start End ft ft ft] Line 1 Level I Line 1, Level 1 Seg 1 0.00 12.00 58.50 46.50 36.50 8.00 Wall 1-1 Seg 1 0.00 12.00 58.50 46.50 36.50 Opening 1 21.00 26.00 5.00 8.00 Opening 2 44.00 49.00 5.00 8.00 Line 2 Level Line 2, Level 1 Seg 1 21.11 0.00 58,50 58.50 22.00 8.00 Wall 2-1 Seg 1 21,00 0,00 12,00 12.00 12.00 Wall 2-2 Seg 1 21.25 12.25 22.25 10.00 10.00 Line 3 Level Line 3, Level 1 Seg 1 43.00 0,00 58,50 58.50 48.50 8.00 Wall 3-1 Seg 1 43.00 0,.00 58.50 58,50 48.50 Opening 1 25.00 30.00 5.00 8.00 Opening 2 35.50 40,50 5.00 8.00 East-West Type Wall Location Extent [ft] Length FHS Height Shearlines Group(s) YUft Start End ft Line A Level Line A. Level 1 Seg I 0,00 21.00 43.00 22.00 6.00 8.00 Wall A-1 Seg 1 0.00 21.00 43.00 22.00 6.00 Opening 1 24.00 40.00 16.00 8.00 Line B Level Line B, Level 1 Seg 2 12.00 0.00 43.00 43.00 7,00 8.00 Wall B-1 Seg 2 12.00 0.00 21.00 21.00 7.00 Opening 1 3.00 13.50 10.50 8.00 Opening 2 17.50 21.00 3.50 8.00 Line C Levell Line C, Level 1 Seg 1 22.25 0.00 43.00 43.00 15.25 8.00 Wall C-1 Seg 1 22.25 27.75 43.00 15.25 15.25 Line D Level Line D, Level I Seg 1 58.50 0.00 43.00 43.00 24.00 8.00 Wall D-1 Seg 1 58.50 0.00 43.00 43,00 24.00 Opening 1 2.00 7.00 5.00 8.00 Opening 2 12,50 16.50 4.00 8.00 Opening 3 25.50 33.50 8.00 8.00 type - eg = segmentea, ,parr = periorarea, rvsw = non-sne twaff, Location - atmension perp. to wali, I -HS - length of full -height sheathing; Well Group(s) - refer to Materials by Wall Group table, refer to Shear Results tables for each design case if more than one group XXX 20th St. Port Townsend, WA 9 of 12 Woo dWorks®Shearwalis Lateral Analysis.wsr Jan. 9, 2008 13:22:55 Flexible Diaphragm Wind Design SHEAR RESULTS North-South W For Shear Force [plf] Allowable Shear [plf] Crit Shearlines Gp Dir Ld. Case V Ibs VIL VIFHS Int Ext Co C Total V lbs ___Resp. Line 1 Level 1 Lnl, Levl 1 Both 1 851 18.3 23.3 339 1.00 S 339 12356 0.07 Line 2 Ln2, Levl 1 Both 1 2814 48.1 127.9 339 1.00 S 339 7447 0.38 Wall 2-1 1 Both 1 1535 - 127.9 339 1.00 339 4062 0.38 Wall 2-2 1 Both 1 1279 127.9 339 1.00 339 3385 0.38 Line 3 Ln3, Levl 1 Both 1 1072 18.3 22.1'' 339 1.00 S 339 16418 0.07 East-West W For Shear Force [plf] Allowable Shear [pif] Crit Shearlines Gp Dir Ld. Case V Ibs WL V/FHS Int Ext Co C Total V[lbs] Resp. Line A Level 1 LnA, Levl 1 Both 1 730 33.2 121.7 339 1.00 S 339 2031 0.36 Line B LnB, Levl 2 Both 1 1651 38.4 235.8 495 1.00 S 495 3463 0.48 Line C LnC, Levl 1 Both 1 3950 91.9 259.0 339 1.00 S 339 5162 0.77 Line D LnD, Levl 1 Both 1 3209 74.6 133.7 339 1.00 S 339 8124 0.40 W Grp - Wall group as listed in Materials table; For Dir - force direction, always "boln ' ; H/W tactor - t -actor clue to snearwalt neignmo-wiotn ratio tear interior and exterior wall sheathing; V - Factored shear force applied to entire line and amount taken by each wall, V/L - Diaphragm shear force = factored sheariine force divided by length of shearline; Following values marked with ` means that value for sheartine is the one for wall with critical design response on line; V/FHS" - Design shear force = factored shear force per unit full height sheathing, Int" - Unit shear capacity of interior sheathing; Ext' - Unit shear capacity of exterior sheathing Co' - Perforation factor, C - Sheathing combination rule, A = Add capacities, S = Strongest side only, X = Strongest side or twice weakest; Total` - Combined unit shear capacity inc. perforation factor and H/W factor, V - Combined shear capacity of wall or total capacity of sheartine ; Crit Resp" - Critical response = Vapp/FHS/Vcap = design shear force/unit shear capacity XXX 20th St. Port Townsend, WA 10 of 12 Woodworks® Shealrwalls Lateral Analysis.wsr Jan. 9, 2008 13:22:55 Flexible Diaphragm Seismic Design SEISMIC INFORMATION Building Area Mass lbs s .ft Story Shear [Ibs] E -W N -S Shear Ratio Rmax E -W NS Reliability Factor p E -W NS Level 81132 2264 10801 10801 0.281 0.217 0.50 0.06 Structure 81132 - 10801 10801 - - 1.00 1.00 Vertical Earthquake load Ear = 0.2 S'ds D; Sds = 0.87 Ev = O� 17 D SHEAR RESULTS North-South W For H/W Fact. Shear Force [plf] Allowable Shear [plf] Crit Shearlines Gp Dir Int Ext V [!bs VIL VIFHS Int Ext Co C Total V[lbs] Resp. Line 1 Level Lnl, Levl 1 Both 1.0 1.0 1704 36.7 46.7 242 1.00 S 242 8826 0.19 Line 2 Ln2, Levl 1 Both 1.0 1.0 3606 61.6 163.9 242 1.00 S 242 5320 0.68 Wall 2-1 1 Both 1.0 1.0 1967 - 163.9 242 1.00 242 2902 0.68 Wall 2-2 1 Both 1.0 1.0 1639 _ 163.9 242 1.00 242 2418 0.68 Line 3 Ln3, Levl 1 Both 1.0 1.0 2251 38.5 46.4 242 1.00 S 242 11727 0.19 East-West W For HtW Fact. Shear Force [plf] Allowable Shear [plf] Crit Shearlines Gp Dir Int Ext V Ibs VIL VIFHS Int Ext Co C Total V[lbs] Resp. Line A Level 1 LnA, Levl 1 Both 1.0 .75 551 • 25.1 91.9 181 1.00 S 181 1088 0.51 Line B LnB, Levl 2 Both 1.0 .75 1487 34.6 212.5 265 1.00 S 265 2209 0.80 Line C LnC, Levl 1 Both 1.0 1.0 2858 66.5 187.4 242 1.00 S 242 3687 0.78 Line D LnD, Levl 1 Both 1.0 1.0 2664 62.0 111.0 242 1.00 S 242 5803 0.46 W Grp - Wall group as listed in Materials table; For Dir- Direction of wind force along shearline; Ld. case -Critical load case: ASCE 7 All heights Case 1 or 2, ASCE 7low rise T = Transverse, L = Longitudinal, all other results are for this load case; V - Factored shear force applied to entire line and amount taken by each wall; VIL - Diaphragm shear force = factored shearline force divided by length of shearline; Following values marked with * means that value for shearline is the one for wall with critical design response on line; V/FHS* - Design shear force = factored shear force per unit full height sheathing, Int* - Unit shear capacity of interior sheathing, Ext* - Unit shear capacity of exterior sheathing Co* - Perforation factor, C - Sheathing combination rule, A = Adel capacities, S = Strongest side only, X = Strongest side or twice weakest; Total* - Combined unit shear capacity inc. perforation factor, V - Combined shear capacity of wall or total capacity of shearline ; Crit Resp* - Critical response = Vapp/FHS/Vcap = design shear force/unit shear capacity XXX 20th St. Port Townsend, WA 11 of 12 •A'M' use only engine d inc. Please complete the information below, sign this request form, and fax to: Hodge Engineering at 253-857-7599 Client Request for Engineering Support *Company: *Contact: *Hodge Engineering Proj #: Architect / Plan # *Site Address: Items with *y are reouired. Description of Problem: REALITY HOMES *Phone: Fax: R8013 Mobile: Email Address: Mailing Address: F orm of Payment Credit Card - Letter by Fax and/or Hard Copy By Mail Pick U - C.O.D. Billing Address: I authorize the above requested work and associated charges. Client Signature (ok to start Work): Client Name (please print): 2601 Jahn Ave NW Suite Al Gig Harbor, WA 98335 Tel: 253-857-7055 Fax: 253-857-7599 www.hodgeen_qin-eeriLig.com 43-0-0 10-0-0 1 '7-10-0 N. 22-0-0 POWER TO PCRF`CFRIN.' Re: GC080041 GOUGONHOURJOB MiTek Industries, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 916/676-1900 Fax 916/676-1909 The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by Lumbermen's Bldg Center -Auburn, WA. Pages or sheets covered by this seal: R27549717 thru R27549721 My license renewal date for the state of Washington is August 1, 2008. 0- January 7,2008 Tingey, Palmer The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI-2002 Chapter 2. Truss Type - . ......... .....� .....m ... qri.. r P y 1 tl i6G JOB .... R2754971 "'' f i 4`4"gYdCrt0N�° t ^08004.1-...,...... m.1.GE ..W,,,,., _,.....,,,,E- ... b Rufa ___CaP�r 4D Truss -Span Lumbermens, AUburn,WA 98001 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:11:58 2008 Page 1 1-4-0 11-0-0 3x6 M1120 = 11-0-0 1-4-0 Scale = 1:43.0 4x0 NIIILu - J4 JJ JL 01 JU Le Lo L/ LO LJ L4 LJ LL Ll Lu 4KO MIILU - 3x6 M1120 = ..-..-w-.._m...,A._..m-..._--------- ..._,......... ��'�Q'�........ .... .�..... ... .........m.. .....,� 22-0-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 25.0 Plates Increase 1.15 TC 0.13 Vert(LL) -0.01 19 n/r 120 M1120 185/148 TCDL 10.0 Lumber Increase 1.15 BC 0.03 Vert(TL) -0.01 19 n/r 90 BCLL 0.0 Rep Stress Incr NO WB 0.05 Horz(TL) 0.00 18 n/a n/a BCDL 10.0 Code IRC2006rrP12002 (Matrix) Weight: 107 Ib LUMBER TOP CHORD 2 X 4 HF 1650F 1.5E BOT CHORD 2 X 4 HF 1650F 1.5E OTHERS 2 X 4 HF Stud/Std BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (Ib/size) 2=220/22-0-0, 27=114/22-0-0, 29=121/22-0-0, 30=120/22-0-0, 31=120/22-0-0, 32=122/22-0-0, 33=106/22-0-0, 34=158/22-0-0, 26=114/22-0-0, 25=121/22-0-0, 24=120/22-0-0, 23=120/22-0-0, 22=122/22-0-0, 21=108/22-0-0, 20=158/22-0-0,18=220122-0-0 Max Horz 2=61 (LC 6) Max Uplift2=-25(LC 5), 29=19(LC 5), 30=-14(LC 5), 31=-14(LC 5), 32=-12(LC 5), 33 -22(LC 5), 25=-20(LC 6), 24=14(LC 6), 23=-14(LC 6), 22=-12(LC 6), 21=-22(LC 6), 18=36(1_C 6) Max Grav 2=220(LC 1), 27=114(LC 1), 29=123(LC 9), 30=120(LC 1), 31=120(LC 1), 32=122(LC 9), 33=108(LC 9), 34=158(LC 9), 26=114(LC 1), 25=123(LC 10), 24=120(LC 1), 23=120(LC 1), 22=122(LC 10), 21=108(LC 10), 20=158(LC 10), 18=220(LC 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/40, 2-3=-69/25, 3-4=41/29, 4-5=32/43,5-6=33157, 6-7=33/71, 7-8=-33/86,8-9=-331102, 9-10=31/89, 10-11=31/88 ,11-12=33/96,12-13=21Y73, 13-14=33/53, 14-15=33/33,15-16=32118,16-17=-3719,17-18=-54/25, 18-19=0/40 BOT CHORD 2-34=0/78, 33-34=0(78, 32-33=0/78, 31-32=0/78, 30-31=0/78, 29-30=0/78, 28-29=0(78, 27-28=0178, 26-27=0(78, 25-26=0(78 ,24-25=0/78,23-24=Or78,22-23=0/78,21-22=0/78,20-21=0(78,18-20=Of78 WEBS 9-27=-87/0, 8-29=-96/35, 7-30=-93/30, 6-31=-93/30, 5-32=-95/30, 4-33=-83/30, 3-34=127/33, 11-26=-87/0, 12-25=96/36, 13-24=-93/30,14-23=-93/30,15-22=-95/30,16-21=-83/30, 17-20=127/33 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opst; BCDI=6.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load noncnncurrent with any other live loads. 5) All plates are 2x4 M1120 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 1 I9 EXPIRES: 08-01-08 January 7,2008 ® WARNING - Ver(ry design parameters and READ NOTES ON THIS AND INCLUDED MITER REFERENCE PAGE MU -7473 O6FOH5 USE. " Design valid for use only with Mi connectors. This design is based only upon parameters shown, ond'a for an individual building component. --� ApplcabirRy of design paramenlers and proper incorporation of component Is responsibility of building designer- not truss designer., Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stability, during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding �awae+e .rsraRM tacrtcolion, quality control, storage, delivery, erection and bracing, consult ANSI//rrPll Quality Criteria, DSB-B9 and BCSII Building Component 7777 Greenback Lane, Suite 109 Safely In oamali. available korn truss Plate Institute, 583 O'Onof io Drive, Madhon, W153719. Citrus Greenback CA- Lane, S 1 ii -TR Truss -Span Lumbermens, Auburn,WA 98001 In °pe COMMON Py qGr 9NHOURJOB 1 II R27549718 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:11:59 2008 Page 1 �,Smm?t...... . ..I".�.�...... .. tt. Qp ... . wt ........... 1ti212 I,............... ...". g.9........._ ........ LJ2� I.p� ...q 1-4-0 5-94 5-2-12 5-2-12 5.94 1-4-0 Scale = 1:43.0 46 M1120 = 4 rxo mucu — I n o vxo rvwcu — 3x4 M1120= 3x6 M1120 = 3x4 M1120= _........... _.... .. ._.,_,,..'�°. _7_--_ ....—...,--_..... 7.'3:_M1T:.:9 _ ------ ______ I 7-6-3 6-11-11 7.6-3 . ., .. ,..... ., LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TC LL 25.0 Plates Increase 1.15 TC 0.32 Vert(LL) -0.07 2-10 >999 240 M1120 185/148 TCDL 10.0 Lumber Increase 1.15 BC 0.39 Vert(TL) -0.22 2-10 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.28 Horz(TL) 0.05 6 n/a n1a BCDL 10.0 Code IRC20061TPI2002 (Matrix) Weight: 80 lb LUMBER BRACING TOP CHORD 2 X 4 HF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied or 5-1-11 oc purlins. BOT CHORD 2 X 4 HF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 HF Stud/Std REACTIONS (Ib/size) 2=108010-3-8, 6=1080/0-3-8 Max Horz 2=61 (LC 6) Max Uplift2=-50(LC 5), 6=-50(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/40,2-3=1686/31, 3-4=1476/49, 4-5=1476/49,5-6=-11686/31, 6-7=0/40 BOT CHORD 2-10=-9/1424, 9-10=0/967, 8-9=0/967, 6-8=0/1424 WEBS 3-10=-358/108, 4-10=4/542, 4-8=-4/542, 5-8=-358/108 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category ll; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard M Io EXPIRES: 08-01-08� January 7,2008 ® WARNING • Verft design parameters and READ NOTES ON TNIS AND INCLUDED MITER REFERENCE PAGE AM -7473 BEFORE USE. e Design valid for use only with MITek connectors. This design Is based only upon parameters shown, and is for an individual building component.. Applicability of design paramenlers and proper Incorporation of component Is responsibility of building designer- not truss designer. Bracing shown ■�� is for lateral support of Individual web members only. Additional temporary bracing to Insure stability during construction is the responsibillity of the I1PII ;Bir K erector. Additional permanent bracing of the overall structure k the responsibility of the building designer. For general guidance regarding r o`w�- r`----• dabrlcollon, gvraTl'ty control, storage. . delivery, erecWn and txrOcP g, consull ANSI/ry11 Quality Criteria, USB -89 and 10511 Building Component 7777 Greenback Lane, Suite 109 Safety Infoimallon available Ifom Prus�s. Plate Institute, $83 VOnofrla Drive, Madison, WI 53719. k Lane, S -__ .... Truss -Span Lumbennens, Auburn,WA 98001 1-4-0 21-6-0 1.ype wv. 3x6 M1120 = 6.00 F12 18 Ply Gnl-IGONHOUR JOB 1 R27549719 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:12:01 2008 Page 1 21-6-0 1-4-0 Scale = 1:80„8 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 4443 42 41 40 39 38 37 36 412 M1120 = 3x8 M1120 = 3x8 M1120 = 412 M1120 = 43-0-0 LOADING (psf)SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 25.0 Plates Increase 1.15 TC 0.13 Vert(LL) -0.01 35 n/r 120 M1120 185/148 TCDL 10.0 Lumber Increase 1.15 BC 0.04 Vert(TL) -0.01 35 n/r 90 BCLL 0.0 "' Rep Stress Incr NO WB 0.12 Horz(TL) 0.01 34 n/a n/a BCDL 10.0 Code IRC2006/TPI2002 (Matrix) Weight 304 lb LUMBER TOP CHORD 2 X 4 HF 165OF 1.5E BOT CHORD 2 X 4 HF 165OF 1.5E OTHERS 2 X 4 HF Stud/Std BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 17-52, 16-53, 15-54, 14-55, 19-51, 20-50„ 21-49, 22-48 REACTIONS (Ib/size) 2=217/43-0-0, 52=115/43-0-0, 53=120/43-0-0, 54=120/43-0-0, 55=120/43-0-0, 56=119/43-0-0, 57=128/43-0-0, 58=120/43-0-0.60=111/43-0-0, 61=121143-0-0,62=120/43-0-0,63=120/43-0-0, 64=120/43-0-0, 65=121/43-0-0, 66=115/43-0-0, 67=142/43-0-0, 51=115/43-0-0, 50=120/43-0-0, 49=120/43-0-0, 48=120143-0-0,47=119/43-0-0. 46=128/43-0-0,45=120/43-0-0, 43=111/43-0-0,42=121/43-0-0,41=120/43-0-0, 40=120/43-0-0,39=120143-0-0. 38=121/43-0-0,34=217/43-0-0,37=115143-0-0,36=142143-0-0 Max Horz 2=105(1-C 6) Max Uplift2=-13(LC 3), 53=-16(LC 5), 54=17(LC 5), 55=-14(LC 5), 56=14(1-C 5), 57=16(1-C 5), 58=-15(LC 5), 60=-10(LC 5), 61=-14(LC 5), 62=-14(LC 5), 63=-14(LC 5), 64=-14(LC 5), 65=-12(LC 5), 66=22(1-C 5), 50=16(LC 6), 49=18(1-C 6), 48=-14(LC 6), 47=-14(LC 6), 46=-16(LC 6), 45=-15(LC 6), 43=-10(LC 6), 42=-14(LC 6), 41=-14(LC 6), 40=14(1-C 6), 39=-14(LC 6), 38=-12(LC 6), 34=-8(LC 6), 37=-22(LC 6) Max Grav2=217(LC 1), 52=115(LC 1), 53=123(LC 9), 54=121(LC 9), 55=120(LC 1), 56=119(LC 9), 57=128(LC 1), 58=120(LC 9), 60=111(LC 1), 61=121(LC 9), 62=120(LC 1), 63=120(LC 1), 64=120(LC 1), 65=121(LC 1), 66=115(LC 9), 67=142(LC 9), 51=115(LC 1), 50=123(LC 10), 49=121(LC 10), 48=120(LC 1), 47=119(LC 10), 46=128(LC 1), 45=120(LC 10), 43=111(LC 1), 42=121(LC 10), 41=120(LC 1), 40=120(LC 1), 39=120(LC 1), 38=121(LC 1), 34=217(LC 1), 37=115(LC 10), 36=142(LC 10) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/40, 2-3=150/34,3-4=-124/36, 4-5=103/44, 5-6=-82/50, 6-7=62/57, 7-8=47(72, 8-9=35/86, 9-10=-35/100, 10-11=31/112, 11-12=34/128, 12-13=-32/142, 13-14=-32/157, 14-15=32/171, 15-16=-32/186, 16-17=32/201, 17-18=-29/169, 18-19=29/167, 19-20=32/195, 20-21=-32/174, 21-22=-32/152, 22-23=-32/132, 23-24=32/111, 24-25=-34/90, 25-26=-31/69, 26-27=-35/56, 27-28=-35/42, 28-29=35/28, 29-30=-35/18, 30-31=39/12, 31-32=59/11, 32-33=-80/8, 33-34=-106/19, 34-35=0/40 BOT CHORD 2-67=0/133, 66-67=0/133, 65-66=0/133, 64-05=0/133, 63-64=0/133, 62-63=0/133, 61-02=0/133, 60-61=0/133, 59-60=0/133, 58-59=0/133, 57-58=0/133, 56-57=0/133, 55-56=0/133, 54-55=0/133, 53-54=0/133, 52-53=0/133, 51-52=0/133, 50-51=0/133 , 49-50=0/133, 48-49=0/133, 47-48=0/133, 46-47=n/133, 45-46=0/133, 4445=0/132, 43-44=0/132, 42-43=0/132, 4142=0/132, 4041=0/132, 39-40=01132,38-39=0/132,37-38=0/132,36-37=0/132,34-36=0/132 WEBS 17-52=-88/0, 16-53=96/32, 15-54=94/33, 14-55=93/30, 13-56=-92/30, 12-57=102/32, 11-58=93/31, 10-60=84/26, 9-61=-94/30, 8-02=93/30, 7-63=93/30, 6-64=-93/30, 5-65=-95/30, 466=-87/31, 3-07=116/31, 19-51=-88/0, 20-50=-96/32, 21-49=94/34, 22-48=-93/30, 23-47=-92/30, 24-46=-102/32, 25-45=-93/31, 2643=-84/26, 27-42=-94/30, 28-41=-93/30, 29-40=93/30, 30-39=93/30, 31-38=95/30, 32-37=-87/31, 33-36=116/31 Continued on page 2 -...... _... EXPIRES: 0$-01-08 January 7,2008 ® WARNING - Ver(jy design parameter and READ NOTES ON THIS AND INCLUDED AfrTER REFERENCE PAGE MU -7473 BEFORE USE. a Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an Individual building component„ Applicability of design paramenlers and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity, of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding """rc""w"in+�.eepnR"a• lobr nfgon quaSlty control, stofoge, delivery. erection and brocw ng, consult ANSIaPII Qualify Criteria, DSB-B9 and BCSII Building Component 7777 Greenback Lane, Suite 109 Safety Infarasaflan available from Truss Plate Insfituie, 583 D"Onufio Drive, Madison, W153719. rG ,..._ Truss T. , rur le Ory Ptly GO NHOUR JOB 827549719 80041 2 -GE GABLE 1 1 .... ob Referee e.(oP.Slpnal) Truss -Span Lumbermens, Auburn,WA 98001 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:12:01 2008 Page 2 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 65mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category ll; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail' 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 2x4 M1120 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 6) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R602.10.2 and referenced standard ANS11TPI 1. LOAD CASE(S) Standard ® WARNING- Perljy design parameters and READ NOTES ON Tffi8 AND INCLUDED MITER iRmF"1$9',arNr�„MC PACE ffif-7473 BEFORE USE. Design valid for use only with Mirek connectors. This design is based only upon parameters shown, and Is for an Individual building component. 111k Applicabilily of design paramenlers and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown - is for lateral support of individual web members only. Additional temporary bracing to insure stability during construction is the responslbillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding q`'nwsoRM• takarticalian. rlu10 V control, storage, delivery, erection and trrac;Ing, consult ARd51/rPll Quality Criteria, DS1-89 and BC511 Building Component Solely Intorrr allan available from Inoss Plate Insfifule, $83 D Onafno Drlve, Madhon, WI 53719. 7777 Greenback tl„a rae�Suile 109 J T7 Greenback x n S Job Truss' rnssType Q...... ....,. _.�. a... _.. _—.._dy — ........... .. R2754972..,. ws� Type PrQUGONHOUR JOB 0 OCO1 1 I Bai041^ 2 -TRS LE1„rlothflefnrprre(Moo nt) Truss -Span Lumbermens, Aubum,WA 98001 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08 :12:04 2008 Page 1 __ -I .. . �k1o. ....,, ..d _ 4t.4 -,R 1-4-0 7-9-0 6-10-6 6-10-6 6-10-6 6-'i0-8 7-9-0 1-4-0 4x4 M1120 % Scale = 1:100.2 8x8 M1120 II NO TOP CHORD NOTCHING IS ALLOWED WITHIN 24” OF THE HEEL JOINTS. 010 M1120 \\ ��-� 4x4 MII20 - 4x10 MII20 4"1112 4x4 M1120 7 4x4 MI120 _- 4x4 MI120 -- 3x4 MI120.w 4x4 M1120 i 3x4 M1120 3x6 M1120! _ 4x4 M1120 C 1120 5x8 M1120 ry,.M'✓ .„., ,ry 3x8 M5x8 M1120 4x4 M1120"" 3x12 M1120H O 5 3x12 M1120H 3x6 M1120 4 , '.,,• 10 3x6 MII20 i 3x6 M1120 3x6 MII20 i 3,.,, 11 3x6 MI120 3x6 M1120 211 12 t"T 7— �: I " , ,"If — — .-- -- - 13 19 1817 89 90 16 91 92 1514 5x6 M1120 = 5x6 M1120 = 8x8 M1120 5x8 M1120 = 44 M1120 = 6x8 M1120 = 6x8 M1120 = 4x4 M1120 = 8x8 M1120 = I.. 9 t'7c1 _._ ......_......i.. 21 f/.... _.L..4 r2....._ , —,-f .. .... 3 9 0'...... I 11-2-4 10-3.12 10-3-12 11-2-4 Plate Offsets (X,Y): [2:0-5-4,0-1-0], [2:1-0-8,0-3-4], [4:04-0,0-3-0], [6:0-6-10,0-1-7], [8:0-6-10,0-1-7], [10:0-4-0,0-3-0], [12:1-0-8,0-3-4], [12:0-5-4,0-1-0], [33:0-0-13,0-0-3], [44:0-1-3 LOADING (psf) SPACING 2-0-0 TCLL 25.0 Plates Increase 1.15 TCDL 10.0 Lumber Increase 1.15 BCLL 0.0 '" Rep Stress Incr NO BCDL 10.0 Code IRC2006/TPI2002 LUMBER TOP CHORD 2 X 4 HF 1650F 1.5E BOT CHORD 2 X 6 HF 165OF 1.5E WEBS 2 X 4 HF Stud/Std OTHERS 2 X 4 HF Stud/Std WEDGE Left: 2 X 4 SYP No,3, Right: 2 X 4 SYP No.3 CSIDEFL in floc) I/deft L/d PLATES GRIP TC 0.35 Vert(LL) -0.2816-18 >999 240 M1120 185/148 BC 0.69 Vert(TL) -0.5416-18 >885 180 M1120H 139/111 WB 0.87 Horz(TL) 0.16 12 n/a n/a (Matrix) Weight: 417 Ib REACTIONS (Ib/size) 2=1807/3-2-0,12=2183/0-5-8. 19=412/3-2-0 Max Horz 2=105(1-C 6) Max Uplift2=106(LC 5), 12=-06(LC 6) Max Grav 2=1807(LC 1), 12=2183(LC 1), 19=423(LC 2) BRACING TOP CHORD Structural wood sheathing directly applied or 4-8-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at micipt 6-16,8-16 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/44, 2-3=3998/105, 3-4=-3594/55, 4-5=-3487/70, 5-6=3431/89, 6-7=2580/105, 7-8=-2579/104, B-9=-3545/68, 9-10=-3593/48, 10-11=3707/47,11-12=4117178,12-13=0/45 BOT CHORD 2-19=107/3496, 18-19=107/3496, 17-18=0/2829,17-89=0/2829,89-90=0/2829, 16-90=0/2829,16-91=0/2870, 91-92=0/2870.15-92=0/2870, 14-15=0/2870,12-14=0/3611 WEBS 21-18=525/159,6-18=0/6711, 6-16=907/143,7-16=0/1705,8-16=-961/131, 8-14=0/787,111-14=5531143 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 2x4 M1120 unless otherwise indicated. 7) Gable studs spaced at 1-4-0 oc. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING- Ver(M design parameters and READ NOTES om TH73 AHD INCLUDED MITER REFERENCE PAGE MR --7473 BEFORE USE. Design valid for use on ywith MiTek connectors. This design is based on Nu on parameters shown, and is for an individual building component. Applic�abilily of design,potamenlen and pfoper iRcorpwafion of componenl h rff"nsfbWty of budding designer. noil truss designer, 5mcinFg shown is lot lalorot support of IndivkJuolwebr membees only, AcddiWnal lurnparory buav; ng to Imwo slab iftyr dueifrg canslmclion Is ine fesporss'dkuM y of the erecter, Additional permanent brac'i'ng at lice overall strvcluae is the rerspongbMily al' the budchng designer. For genp-raal gualdance moordl'ng Serfe cal1a11, rgua6ly contiof, stkrage, delive q. erection and bvc0ng, consult A14SI/rPit Quality Criteria, DSB-B9 and BCSII Building Component bafalygnlarmaffon oyaHable from Truss Pkale Institute, 55,63 D'Onofno Drive, Madho�n,. at 53719. v'i� t.""b Wr� C,J l M1,J7 1, "A� EXP......_-.— !RES: O , 0$ _--01-08 January 7,2008 am I171]1 w �owure rs`rvRM- 7777 Greenback Lane, Suite 109 Job Truss .... T..--.... m ,, ... _.. - Type .... _._.. „ ,,,.— Rty ...... ...... .... .. . �., ...,—„......_. Ply f 3ONHOUR JOB R27549721 GC060041 2 -TSC Sr _,AAL 23 1 ....,.e,_ _......- �— Reference (opbgngj) s........ JRtr __...._ — —..... Truss -Span Lumbermens, Auburn,WA 98001 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:12:05 2008 Page 1 __..,.....m. .........i "�8 �r0.� 1.,..... - 1-4-0 6-7-5 7-11-5 6-11-6 6.11-13 6-11-13 7-6-5 1-4-0 Scale = 1:88.2 5xB M1120 = 6.00 12 O 5x12 M1120 % 2x4 M1120 I I Zxv m11Lu 11 5x12 M1120 16 20 15 14 13 3.00 12 8x12 M1120 = 5x8 M1120 = 2x4 M1120 11 44 M1120 = ........ ....t .._. ... :.,.m .. .......,q 5-8-5 5-0-7 3-9-14 6-5-0 7-5-13 6-11-13 7-6-5 _............... .... ., -platfl:.oOt5-MyL d E t41e)5 g -1.L... LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 25.0 Plates Increase 1.15 TC 0.98 Vert(LL) -0.57 18 >894 240 M1120 185/148 TCDL 10.0 Lumber Increase 1.15 BC 0.84 Vert(TL) -1.22 17-18 >418 180 BCLL 0.0 '” Rep Stress Incr YES WB 0.89 Horz(TL) 0.57 11 n/a n/a BCDL 10.0 Code IRC2006/TP12002 (Matrix) Weight: 217 Ib LUMBER BRACING TOP CHORD 2 X 4 HF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2 X 6 HF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 HF Stud/Std *Except* WEBS 1 Row at midpt 8-16 6-18 2 X 4 HF No.2 2 Rows at 1/3 pts 6-16 REACTIONS (Ib/size) 2=2075/0-5-8, 11=2109/0-5-8 Max Horz 2=106(1_C 6) Max Uplift2=62(LC 5), 11=-62(LC 6) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2=0/43, 2-3=6970/81, 3-4=-6313/63, 4-5=-6254/96, 5-6=-6158/110, 6-7=2419/100, 7-8=-2343/106, 8-9=-2964/64, 9-10=-3161/31, 10-11=3865/38,11-12=0/45 BOT CHORD 2-19=-101/6283, 18-19=-99/6287, 17-18=0/3496,16-17=0/3520,16-20=0/2728, 15-20=0/2728,14-15=0/3343,13-14=0/3343 ,11-13=0/3343 WEBS 3-19=0/202, 3-18=573/88, 6-18=-63/3425, 6-17=0/260, 6-16=1998/98, 7-16=0/1528, 8-16=1034/106, 8-15=0/586, 10-15=-700/83, 10-13=0/308, 4-18=-182/59 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) ` This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing at joint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard ® WARNING - Verft design parameters and READ NOTES ON THIS AND INCLUDED MITEK REFERENCE PAGE AU -7473 BEFORE USE. Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design parameniers and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of indvidual web members only. Additional temporary bracing to insure stability during construction Is the responsibillity of the erector. Additional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding lcubir oWn,. quoky control, storage, delivery, erection orad brocingg, consult ANSI/�P11 Quality Criteria, DSB-89 and BCSII Building Component lately tnfatmallan available from Irust Plate Ins1'14uie, 583 D'Onohlo Drive, Madison,. WI 53719. EXPIRES 08-010 _ January 7,2008 of M iTe C POWCR A IY:RNRN.' 7777 Greenback Lane, Suite 109 t/1 } O 0 E > E )ca $ o� Q o a) 0 `m o a �o O a) a �_2 a) U > U D 'C Z O II O O O C U O p °) c c a� ° r m v 6 �3a o aro o o ° u 3c �. N C Ilt W O c ° L N O C C 0 E C N t O O€ _ ° 7^ O C �r Ln E a ° u D 3 c u o `o - o p. to c a a a) o a a� _0 a) " 5 p Z) �Do a12° a°i a)° o a°�m a� a�ci`o ° 00 of -0 o °� 0 gym' �� a C-0 O _ C^ )-tz U O N _ N O C c p) O p 0 D 'a W' •O. p �/� IT °0 m L" 2 a c_ 0 �� UD �p Ncc �gO,+Cy' Nw a U N a a 2 001 U N T 0OO a� CO 6 ?0 NL N 0 C%y0 ��O Oai a1 a) O 0`O N a1 v c� C _ Q m c _ D O _ o 0 N' C'O a i _ 0 0 Z O• O at O O U C fie", �- "0 w D N o .2).- .2.. a) D O rno rn° °'a°'`1 0 ° o m > D� o aaa uoz °coo a1n �c m m E " v� L U p u oUrn� ? aZi °' � u v E c �� O o �° a°1 � ° o E� -> m tea' 2 V) 0) a)Tot O N O O-0 .� -C�"Q1 4a7 U N ° U 0 07 ° hC 3 J C a) > > >- D c rip -0 c r o. a) u �x s au 2 o o `o c c ^^`` O c p __ c o o. p o ° E D a m '� -"-' C }'rn 'c p. a. o o U O W `�–w�yy a) C C-0 D J C O'v vs` C — 7 DU QO) C a) wdt a'tD CO _ - a j C U D O 0 0 p O U 0) N -0 C ... C r 0 ._. - a a) N C U a) > E n' L. � D E O c Ot wit C O N .- p .0 a) aM E. _ j 0 - C O C "0 O- N t D Q) W O 6X 0D O UN C OD a) cO NN U a) 0 O 0 C ,w O rnp ° a�.� ago 12 EE � �� �0 E•- u `oma o c c o-° E� v o s' o o a� n °� o a� Xi a o o a� y 0 0 0 o am °) a °) 'u O O N a- a °-� xp u E o 0p Lm --9 o� as �� u ua c a) ,o awl o- �- °o 2a mE ��� o ac0 °� °o 0� y�°c� �=) a`)E)E Lrn E'er a°i > o3�� c� O m �a)>.•u > rno E c°'i po �_ EOD a)° D_u p:O o c `oo 0 00 0 00� rnC -p p j� O O al p O ff_ 7 0� U a) O C O , 0� 0 0 '0 j 0 a Q a U� O O O. O C O Q 0) Z Q `6 t= E D Z a_ U 6 U U U a .S �- 0 0 U 0 0 S N a w O 'D 0 Q a - Q N M V h. 6 n W 0rv'. CA O N M V �O 1� 00 O� O (ROHO dOl ate) m o Q) Cie 2S UW L a O= r m� T N Cl) r a ,0 u� O < A, U r LU y c LU ? Z [ u Lit c r, w ds n \ W m b ch ( y t/i 3 u zy a o= o v 4[ w ce o ° Q oWe ° C. o Q •� LLJ -° 0 z be L. CV 0 C-ZM I� Q Q d W W 01 d 1?S11 Qy N Q LO I" -1O smW 0_ m he W V) WH W ('7� �� ' 0 Wo[ 3Wt O t V°'�P t W= Z J U Q w�ZM Lr f- a) U 0.1 00 00 j3 N a0 y Z ri O W W 00 O FYl`J pp z O W O f O U (MONO dol ° a U Z a- w a z a °-C U �_ _ o O c00 o C0�0c00x0o1 cn`n 0U 0- 0 ?7 u N � � -0 p E= ' 0 o — a) j �O� 0 -C� �00 O o3u•O 0� o 0 °`ca2a U �u Eoo 0'-0 -0a0Q C°ua)oai Voa�aI U 2 C - U.Ll a) U o Z c CO Z ro O a a 0 U U 0 0 -EU 0 p N O •- E O N O N -6 O O N t a3 a) O 0)� O °�0= cvo o E0u oN �E0.a 00 mom' quo Za)a)o� �� �c °� mom_ a) O v�av uQu a)a)�o0co Z N E O C O p 6 0 Q �" O -� Q �. � c -0 7 0 Q U on< O � 0_ C) r U N r- 3� C� O= �� C O O� �O D)V y Z « �c �cUcc cel ii U r = z W w c Z O C U ° m ° s I tOo yam/ X (� h� W ? CL p. FW in .. 0 LU Z m U a IL Q U . m - Q 0 m 11 0 10-0-0 '7-10-0 POWER ro PERFORWI Re: GC080041 GOUGONHOURJOB MiTek Industries, Inc. 7777 Greenback Lane Suite 109 Citrus Heights, CA, 95610 Telephone 916/676-1900 Fax 916/676-1909 The truss drawing(s) referenced below have been prepared by MiTek Industries, Inc. under my direct supervision based on the parameters provided by Lumbermen's Bldg Center -Auburn, WA. Pages or sheets covered by this seal: 827549717 thru 827549721 My license renewal date for the state of Washington is August 1, 2008. January 7,2008 Tingey, Palmer The seal on these drawings indicate acceptance of professional engineering responsibility solely for the truss components shown. The suitability and use of this component for any particular building is the responsibility of the building designer, per ANSI/TPI-2002 Chapter 2. GeC081,. 1 -GE Ts.�Yp nlY Truss... .. w.,.. y e y GQQGONHOURJOB R27549717 004 1 -. ........,,,-,._ ..__ ...�. �...... ..... ...-,.... ...m .,. �..,. �. ....... ,m_- ._.,,. ,..Jtab ItPferrnce,(opt�pnal.)-------- ----..... .. .... ... .. Truss -Span Lumbermens, Auburn,WA 98001 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:11:58 2008 Page 1 I 1-4-0 11-0-0 3x6 M1120 = 10 11-0-0 1-4-0 Scale = 1:43.D 4x6 M1120 = 34 33 32 31 3u 29 26 Z( Zb Z5 24 23 ZZ L1 Zu 4Xb MIIZU - LOADING (psf) SPACING2-0-0 (loc) CSI TCLL 25.0 Plates Increase 1.15 TC 0.13 TCDL 10.0 Lumber Increase 1.15 BC 0.03 BCLL 0.0 "' Rep Stress Incr NO WB 0.05 BCDL 10.0 Code IRC2006/TPI2002 (Matrix) LUMBER TOP CHORD 2 X 4 HF 165OF 1.5E BOT CHORD 2 X 4 HF 165OF 1.5E OTHERS 2 X 4 HF Stud/Std 3x6 M1120 - 22-0.0 DEFL in (loc) Ildefl Ud PLATES GRIP Vert(LL) -0.01 19 n/r 120 M1120 185/148 Vert(TL) -0.01 19 n/r 90 Horz(TL) 0.00 18 n/a n/a Weight: 107 Ib BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. REACTIONS (Ib/size) 2=220/22-0-0, 27=114/22-0-0, 29=121/22-0-0, 30=120/22-0-0, 31=120/22-0-0, 32=122/22-0-0, 33=108/22-0-0, 34=158/22-0-0, 26=114/22-0-0, 25=121122-0-0, 24=120/22-0-0, 23=120/22-0-0, 22=122/22-0-0, 21=108/22-0-0, 20=158/22-0-0, 18=220/22-0-0 Max Horz 2=61 (LC 6) Max Uplift2=25(LC 5), 29=19(LC 5), 30=14(LC 5), 31=-14(LC 5), 32=-12(LC 5), 33=-22(LC 5), 25=-20(LC 6), 24=-14(LC 6), 23=-14(LC 6), 22=12(LC 6), 21=-22(LC 6), 18=36(LC 6) Max Grav 2=220(LC 1), 27=114(LC 1), 29=123(LC 9), 30=120(LC 1), 31=120(LC 1), 32=122(LC 9), 33=108(LC 9), 34=158(LC 9), 26=114(LC 1), 25=123(LC 10), 24=120(LC 1), 23=120(LC 1), 22=122(LC 10), 21=108(LC 10), 20=158(LC 10), 18=220(LC 1) FORCES (lb) -Maximum Compression/Maximum Tension TOP CHORD 1-2=0/40, 2-3=-69/25, 3-4=41/29, 4-5=32143, 5-6=33/57, 6-7=-33171, 7-8=-33/86, 8-9=33/102, 9-10=-31/89, 10-11=-31/88 , 11-12=-33/96, 1 2-1 3=3 3173, 13-14=33153, 14-15=33/33, 15-16=32/18, 16-17=-37/9, 17-18=54/25,18-19=0/40 BOT CHORD 2-34=0/78, 33-34=0(78, 32-33=0178, 31-32=0/78, 30-31=0/78, 29-30=0(78, 28-29=0178, 27-28=0/78, 26-27=0/78, 25-26=0178 , 24-25=0178, 23-24=0178, 22-23=0178, 21-22=0178, 20-21=0/78, 18-20=0(78 WEBS 9-27=-87/0, 8-29=96/35, 7-30=-93130, 6-31=-93/30, 5-32=-95/30, 4-33=-83/30, 3-34=127/33,11-26=-8710, 12-25=96/36, 13-24=-93/30,14-23=-93/30,15-22=95130, 16-21=-83/30,17-20=127/33 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail' 4) This truss has been designed fnr a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 2x4 M1120 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Vertjy design parameters and READ NOTES ON THIS AND INCLUDED JUTER' R6PRRRNCE PAGE MU -7473 BEFORE USE. Design valid for use only with M1ek connectors.. This design is based only upon parameters shown, and is for an individual building component. Appllcabilify of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction Is the responslbillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding tntxVicertlan, sao gyp control, slolooe, d *livery, erection *erect' Lmctcing, consrxll AN51/TPII QualHy criteria, DS® -B9 and ®CSII Building Component Safety Infsrmatllan avallable from Truss Plate Institute, 543 O'Onofno Drove, Madison, 153719. y //adp, t fi d EXPIRES: 04 01-08 .� January 7,2008 %Mii'ek' "rowsia +m'vriir"aw-mu 7777 Greenback Lane, Suite 109 Truss -Span Lumbermens, Auburn,WA 98001 1-4-0 5-9-4 5-2-12 5-2-12 48 M1120 = 4 G/ "1NHOUR JOB R27549718 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:11:59 2008 Page 1 5-94 1-4-0 Scale = 1:43.0 io 4xa MIIGU — lu to o Oxo MIILu — 3x4 M1120 = 3x6 M1120 = 3x4 M1120 = f........ ................ _.. — L 7-6-3 6-11-11 76-3 LOADING (psf) SPACING 2-0-0 CSI DEFL in floc) I/defi L/d PLATES GRIP TCLL 25.0 Plates Increase 1.15 TC 0.32 Vert(LL) -0.07 2-10 >999 240 M1120 1851148 TCDL 10.0 Lumber Increase 1.15 BC 0.39 Vert(TL) -0.22 2-10 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.28 Horz(TL) 0.05 6 n/a n/a BCDL 10.0 Code IRC2006/TPI2002 (Matrix) Weight: 80 lb LUMBER BRACING TOP CHORD 2 X 4 HF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 5-1-11 oc purlins. BOT CHORD 2 X 4 HF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, WEBS 2 X 4 HF Stud/Std REACTIONS (lb/size) 2=1080/0-3-8,6=1080/0-3-8 Max Horz 2=-61(LC 6) Max Uplift2=-50(LC 5), 6=-50(LC 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/40, 2-3=1686/31, 3-4=1476/49.4-5=-1476/49,5-6=-1686/31, 6-7=0/40 BOT CHORD 2-10=9/1424, 9-10=0/967, 8-9=01967, 6-8=0/1424 WEBS 3-10=-358/108, 4-10=-4/542, 4-8=4/542, 5-8=-358/108 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARKLMO - 9er(fq design parameters and READ NOTES ON THIS AND INCLUDED WTER REFERENCE PAGE MU -9473 BEFORE USE. Design valid for use only with MiTek connectors. This design Is based only upon parameters shown, and is for an individual building component. Applicability of design paramenters and proper incorporation of component is responsibility of building designer- not truss designer. Bracing shown is for lateral support of Individual web members only. Additional temporary bracing to insure stability during construction is the responsibillity of the erector. Adcllional permanent bracing of the overall structure Is the responsibility of the building designer. For general guidance regarding r0I! A L EXPIRES: 0S-01�08 January 7,2008 fob lrallon ,quaBly control, sloor„,I;ge, delivery. erection sand bfao ng, co�n%4 ANSI PIl ®ua0ty Crtlefla, DSB-89 and BCSII Building Component 7777 Greenback Lane, Suite 109 Safety InlaPmfmMGon available ttam. Truss Plate Instituie, 583 DrOnofno Drive.,, Mad4on, WI 53719. _.. . , Greenback ___ ._ GCOB0041 2 GE ,_ ........ 6 EYPe _,....... Idiy Pp. - .._._.,y 1GONHOUR JOB -827549719_ ... w_ .-.-, ..,. .µ _ _ .... _______ Job Reference (oplione,(� Truss -Span Lumbermens, AUburn,WA 98001 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:12:01 2008 Page 1 1-4-0 21-8-0 3x8 M1120 = 6.00 92 17 18 19 21-6-0 1.4-0 Scale = 1:80.8 67 66 65 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 4443 42 41 40 39 36 37 36 4x12 M1120 = 3x8 M1120 = 3x6 M1120 = 402 M1120 = 4M-0 LOADING (psf)SPACING 2-0-0 CSI DEFL in (loc) Ilden L/d PLATES GRIP TCLL 25.0 Plates Increase 1.15 TC 0.13 Vert(LL) -0.01 35 n/r 120 M1120 185/148 TCDL 10.0 Lumber Increase 1.15 BC 0.04 Vert(TL) -0.01 35 nlr 90 BCLL 0.0 Rep Stress Incr NO WB 0.12 Horz(TL) 0.01 34 n/a n/a BCDL 10.0 - Code IRC2006rrP12002 ..._ ......... (Matrix) Weight: 304 lb LUMBER TOP CHORD 2 X 4 HF 165OF 1.5E BOT CHORD 2 X 4 HF 165OF 1.5E OTHERS 2 X 4 HF Stud/Std BRACING TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 17-52, 16-53, 15-54, 14-55, 19-51, 20-50, 21-49,22-48 REACTIONS (Ib/size) 2=217/43-0-0, 52=115/43-0-0, 53=120/43-0-0, 54=120143-0-0,55=120143-0-0,56=119/43-0-0, 57=128/43-0-0, 58=120/43-0-0,60=111143-0-0, 61=121/43-0-0, 62=120/43-0-0, 63=120/43-0-0, 64=120143-0-0, 65=121/43-0-0, 66=115/43-0-0, 67=142/43-0-0, 51=115/43-0-0, 50=120143-0-0, 49=120/43-0-0, 48=120/43-0-0,47=119/43-0-0, 46=128/43-0-0, 45=120/43-0-0, 43=111/43-0-0, 42=121143-0-0, 41=120/43-0-0, 40=120/43-0-0,39=120/43-0-0, 38=121/43-0-0, 34=217/43-0-0, 37=115/43-0-0, 36=142143-0-0 Max Horz 2=-105(LC 6) Max Uplift2=-13(LC 3), 53=-16(LC 5), 54=17(LC 5), 55=14(LC 5), 56=-14(LC 5), 57=-16(LC 5), 58=-15(LC 5), 60=-10(LC 5), 61=-14(LC 5), 62=-14(LC 5), 63=-14(LC 5), 64=-14(LC 5), 65=-12(LC 5), 66=22(LC 5), 50=16(LC 6), 49=-18(LC 6), 48=-14(LC 6), 47=-14(LC 6), 46=-16(LC 6), 45=-15(LC 6), 43=-10(LC 6), 42=14(LC 6), 41=14(LC 6), 40=14(1_13 6), 39=-14(LC 6), 38=-12(LC 6), 34=-8(LC 6), 37=22(LC 6) Max Grav 2=217(LC 1), 52=115(LC 1), 53=123(LC 9), 54=121(LC 9), 55=120(LC 1), 56=119(LC 9), 57=128(LC 1), 58=120(LC 9), 60=111(LC 1), 61=121(LC 9), 62=120(LC 1), 63=120(LC 1), 64=120(LC 1), 65=121(LC 1), 66=115(LC 9), 67=142(LC 9), 51=115(LC 1), 50=123(LC 10), 49=121(LC 10), 48=120(LC 1), 47=119(LC 10), 46=128(LC 1), 45=120(LC 10), 43=111(LC 1), 42=121(LC 10), 41=120(LC 1), 40=120(LC 1), 39=120(LC 1), 38=121(LC 1), 34=217(LC 1), 37=115(LC 10), 36=142(LC 10) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/40, 2-3=-150/34,3-4=-124/36, 4-5=-103/44.5-6=82/50,6-7=62/57, 7-8=47/72, 8-9=-35/86,9-10=-351100, 10-11=-31/112, 11-12=34/128, 12-13=-32/142, 13-14=-32/157, 14-15=32/171, 15-16=-32/186, 16-17=32/201, 17-18=-29/169, 18-19=291167, 19-20=-32/195, 20-21=-32/174, 21-22=32/152, 22-23=-32/132,23-24=32/111' 24-25=-34/90, 25-26=-31/69, 26-27=-35/56, 27-28=-35/42, 28-29=35/28, 29-30=35/18, 30-31=39/12, 31-32=59111, 32-33=-80/8, 33-34=106/19, 34-35=0/40 BOT CHORD 2-07=0/133, 66-67=0t133, 65-66=0/133, 64-05=0/133, 63-64=0/133, 62-63=0/133, 61-02=0/133, 60-61=01133, 59-60=0/133, 58-59=0/133,57-58=0/133,56-57=0/133,55-56=01133,54-55=01133, 53-54=0/133, 52-53=0/133,51-52=0/133, 50-51=0/133 , 49-50=0!133, 48-49=0/133, 47-48=0/133, 4647=0/133, 45-46=0/133, 44-45=0/132, 43-44=0/132, 42-43=0/1 3 2, 41-42=0/132, 40-41=0/132, 3940=0/132, 38-39=0/1 3 2, 37-38=0/132, 36-37=0/132, 34-36=0/132 WEBS 17-52=-88/0, 16 -53=96/32,15-54=94/33,14-55=93130,13-56=-92130,12-57=-102/32. 11-58=93/31, 10-60=84/26, 9-01=-94/30, 8-62=-93130, 7-63=93/30, 6-64=93/30, 5-65=-95130, 4-66=-87/31, 3-67=-116131, 19-51=-88/0, 20-50=-96/32, 21-49=94/34, 22-48=-93/30, 23-47=92/30, 24-46=-102/32, 25-45=-93/31, 26-43=-84/26, 27-42=-94/30, 28-41=-93/30, 29-40=-93/30, 30-39=-93/30, 31-38=95/30, 32-37=-87/31, 33-36=116/31 Continued on page 2 WARNING - Veryy design parameters and READ NOTES ON THIS AND INCLUDED MITEI( NE&ENCE PAG& MU -7473 BEFORE USE. Design vafld for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component. Applicability of design paromenters and proper Incorporation of component is responsibility of building designer- not truss designer. Bracing shown Is for lateral support of individual web members only. Additional temporary bracing to insure stabinty during construction Is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding lo-T,x1cofiom, quatly control, stotoge, delivery, erection and bracing consult ANSIal f Quality Criteria, D3B-87 and BCSIl Building Component Safety Infaamthon available from Truss Plate Insfituvie, 583 D Onofrfo Drive, Madison, WI 5311 SI,)f, �)"O ALV,C"il ---EXPIRES'mm0 January 7,2008 7777 Greenback lane, Suite 109 Truss -Span Lumbermens, Auburn,WA 98001 Gr NHOURJOB R27549719 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:12:01 2008 Page 2 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail' 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 2x4 M1120 unless otherwise indicated. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 1-4-0 oc. 8) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNDYG - PerVy design parameters and READ NOTES ON THIS AND INCLUDED AUTEK REFERENCE PAGE MU -7473 BEFORE USE. A Design valid for use only with MiTek connectors. This design is based only upon parameters shown, and Is for an Individual building component. Appricabifily of design parameniers and proper incorporation of component Is responsibility of building designer- not truss designer. Bracing shown t is for lateral support of individual web members only. Additional temporary bracing to Insure stability during construction Is the responsibillity of the *'je erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding P'vivcw+e rinivRia- fairrtlfratl+an yuaSty control storage. delivery, erwralion and bracing, consult ANSI/TPll Quality Criteria, DSB-89 and BCS11 Building Component 7777 Greenback Lane, Suite 109 Safetylntwmalion available rrarwm lruu Plate Ins IIS,d"Ono fro Drive, Madison, WI 53719. „_,_A,,, „. .— ... _,.... _ _..� .__...—_,�w... ob Truss �T' +rs Typa Oty Ply � t�±9ttlGtDNf°ld�tJR JOB 1 1 I'GCbll 41— 2 -TRS _ ... �. ...,.E 827549720 .. _. _. .�pflb,ltafarorce (slplwe1r11aN), _ Truss -Span Lumbermens, Aubum,WA 98001 7.020 s Nov 9 2007 MiTek Industries, Inc. Mon Jan 07 08:12:04 2008 Page 1 �... .....i .........s __roa._._._._..m est........ e._.ma...... ...... Iaa 1-4-0 7-9-0 6-10-8 6-10-8 6-10-8 6-10-8 7-9-0 1-4-0 4x4 M1120 % Scale = 1:100.2 6x8 M1120 I NO TOP CHORD NOTCHING IS ALLOWED WITHIN 24" OF THE HEEL JOINTS. 4x10 MI 120 \\ 4x4 MII20 � 4x10 M1120 4"'J'19"'4x4 M1120 % 7 44 MI120 -Z�- 4x4 MI120 J 3x4 Mv.bO -- 4x4 MI120 - 3x4 M1120 3x8 M1120 4x4 MII20 5xB M1120 3x6 M1120 4x4 M1120 % -..,, 5x8 M1120 6 ,. 8 44 M1120 302 M1120HO 5 ,,. '^' ,, 9 302 M1120H O 3x6 M1120 4 10 3x6 MII20 3x6 M1120 3x6 M1120 3 ' 11 3x6 M1120 3x6 M1120 x."*. m 2 I +, 12 $3 I,O Y 19 1817 89 90 16 91 92 1514 5x6 M1120 = 5x6 M1120 = 8x8 M1120 5x6 M1120 = 4x4 M1120 = 6x6 M1120 = 6x8 M1120 = 44 M1120 = 8x8 M1120 = I....m 11 7:4 . ..... i ------- 30-,9J .,— ....1_— 4119 .... l 11-2-4 10-3-12 10-3-12 11-2-4 Plate Offsets (X,Y): [2:0-5-4,0-1-0], [2:1-0-8,0-3-4], [4:0-4-0,0-3-0], [6:0-6-10,0-1-7], [8:0-6-10,0-1-7], [10:0-4-0,0-3-0], [12:1-0-8,0-3-4], [12:0-5-4,0-1-0], [33:0-0-13,0-0-3], [44:0-1-3 LOADING (psf) SPACING 2-0-0 TCLL 25.0 Plates Increase 1.15 TCDL 10.0 Lumber Increase 1.15 BCLL 0.0 Rep Stress Incr NO BCDL 10.0 Code IRC2006/TPI2002 LUMBER TOP CHORD 2 X 4 HF 1650F 1.5E BOT CHORD 2 X 6 HF 165OF 1.5E WEBS 2 X 4 HF Stud/Std OTHERS 2 X 4 HF Stud/Std WEDGE Left: 2 X 4 SYP No.3, Right: 2 X 4 SYP No.3 CSI DEFL in (loc) I/defl Ud PLATES GRIP TC 0.35 Vert(LL) -0.2816-18 >999 240 M1120 185/148 BC 0.69 Vert(TL) -0.5416-18 >885 180 M1120H 139/111 WB 0.87 Horz(TL) 0.16 12 n/a n/a (Matrix) Weight: 417 Ib REACTIONS (Ib/size) 2=180713-2-0,12=2163/0-5-8, 19=412/3-2-0 Max Hoa 2=105(LC 6) Max Uplift 2=106(!-C 5), 12=-66(LC 6) Max Grav 2=1 807(LC 1), 12=2183(LC 1), 19=423(LC 2) BRACING TOP CHORD Structural wood sheathing directly applied or 4-8-2 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 6-16,8-16 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/44, 2-3=3998/105, 3-4=-3594/55, 4-5=-3487/70, 5-6=-3431/89, 6-7=2580/105, 7-8=-2579/104, 8-9=-3545/68, 9-10=-3593/48, 10-11=3707/47,11-12=4117/78,12-13=0/45 BOT CHORD 2-19=1107/3496,118-19=110713496, 17-18=0/2829, 17-89=012829,89-90=0/2829,16-90=0/2829, 16-91=0/2870, 91-92=0/2870, 15-92=0/2870, 14-15=0/2870, 12-14=0/3611 WEBS 3-18=-525/159,6-18=0/671, 6-116=907/1143,7-116=0/1705, 8-16=-961/131, 8-14=0/787, 11-14=553/143 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category 11; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail' 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are MT20 plates unless otherwise indicated. 6) All plates are 2x4 M1120 unless otherwise indicated. 7) Gable studs spaced at 14-0 oc. 8) . This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard ® WARNING - Verify design parameters and READ NOTES ON TNIS AND INCLUDED MTEK REFERENCE PACE AM. 7473 DEMRE USE. Design varid for use only with MiTek connectors. This design is based only upon parameters shown, and is for an individual building component,. Applicability of design paramenlers and proper incorporation of component is responsibility of building designer- not lruss designer. Bracing shown is for lateral support of individual web members only., Addilional temporary bracing to Insure stability during conslrucllon is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding tloba'icatldon cl4fakgy control sloraage, delivery, erection and bracing, consult ANSI//TrPII Quality Criteria, DSB-67 and BCSII Building Component Safety intarmalion available krc>n1 Truss Plate Institute, 58:6 L O" (i;rafno Drlve„ Madlson, WI53719. EXPIRE�:O�- �0 January 7,2008 7777 Greenback Lane, Suite 109 1e !',Ory {Ply I GO NHOUR JOB 827549721 SPEUAL Truss -Span Lumbermens, Auburn,WA 98001 7.020 s Nov 9 2007 MiTek Industries, Inc, Mon Jan 07 08:12:05 2008 Page 1 11.x,„ _ A7-5.- .. n-1-.. _... 94. 117_- -I — ,5 i..- ... ...... �r. 1-4.0 6-7-5 7-11-5 5-11-6 6-11-13 6-11-13 7-6-5 1-4-0 Scale = 1:88.2 5x8 M1120 = 6.00 12 502 M1120 % 2.4 M1120 11 cnv nnicu 11 16 20 15 14 13 5x12 M1120 I- 3.00 12 8x12 M1120 = 5x8 M1120 = 2x4 M1120 11 4x4 M1120 = I �&Z5 ... 19-.012----IJ4-.0-10 .. i ..3 .1,11. y 4'ry4-'0------- N 5.6-5 5-0-7 3-9-14 B-5-6 7-5-13 6-11-13 7-0-5 1sLsi61s ) . -. ....._ ....,.. LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl L/d PLATES GRIP TCLL 25.0 Plates Increase 1.15 TC 0.98 Vert(LL) -0.57 18 >894 240 M1120 185/148 TCDL 10.0 Lumber Increase 1.15 BC 0.84 Vert(TL) -1.22 17-18 >418 180 BCLL 0.0 Rep Stress Incr YES WB 0.89 Horz(TL) 0.57 11 nla n/a BCDL 10.0 Code IRC2006ITP12002 (Matrix) Weight: 217 lb LUMBER BRACING TOP CHORD 2 X 4 HF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied. BOT CHORD 2 X 6 HF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 HF Stud/Std 'Except" WEBS 1 Row at midpt 8-16 6-18 2 X 4 HF No.2 2 Rows at 1/3 pts 6-16 REACTIONS (lb/size) 2=2075/0-5-8.11=2109/0-5-8 Max Horz 2=106(LC 6) Max Uplift2=62(1-C 5), 11=-62(LC 6) FORCES (Ib) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/43, 2-3=6970/81, 3-4=6313/63, 4-5=6254/96, 5-6=6158/110, 6-7=2419/100, 7-6=-2343/106, 8-9=-2964/64, 9-10=-3161/31, 10-11=3865138, 11-12=0/45 BOT CHORD 2-19=-101/6283, 18-19=-99/6287, 17-18=0/3496, 16-17=0/3520, 16-20=0/2728, 15-20=0/2728, 14-15=0/3343, 13-14=0/3343 , 11-13=0/3343 WEBS 3-19=0/202,3-18=-573/88, 6-18=-63/3425,6-17=0/260,6-16=1998/98, 7-16=0/1528,8-16=10341106,8-15=0/586, 10-15=-700/83, 10-13=0/308, 4-18=-182/59 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-05; 85mph; h=25ft; TCDL=6.Opsf; BCDL=6.Opsf; Category II; Exp B; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all, areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members. 5) Bearing atjoint(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard WARNING - Ver(fy design parameters and READ NOTES ON THIS AND INCLUDED A17TER REFERENCE PAGE ADI --7473 BEFORE USE. Design valid for use only with M1ek connectors. This design Is based only upon paramelen shown, and is for an individual building component. Appficabilily of design paromeniers and proper incorporation of component Is responsibility of building designer- not truss designer, Bracing shown Is for lateral support of individual web members only, Additional temporary bracing 10 insure stability during construction is the responsibillity of the erector. Additional permanent bracing of the overall structure is the responsibility of the building designer. For general guidance regarding foladc.affon quoalty control, storage, delivery, erection and bracing, consult ANSI/FPII Quality Criteria, DSB-89 and BCSII Building Component Safety Infosmafton available fmm Truss Plate Ins.lilule, 583 'f3"Onafno Drive, Madison, 153719. ... � EXPIRES08-01-0F"—" January 7,2008 7777 Greenback Lane. Suite 109 GNOHO dOl M a•ih5.. 10 Vd N O U CL O X C— a) O D•N z p •od o m I-- 0.5-0 O 1 O Q N O-0 z2E-oadE W O W C —a (D 0 t) T Z ��E_a-CO: Q 000<0 O o Q 4-- U 0 W CL IQ J adOH3 d01 co C a> L O mO P W vd O 3 �-- Y H UW UQ O� W z LU W ? UO J W ad W ~ Lu a ca �z z� J a J h KN W Vd z= LU Y V W ac Z=W O W Oar O N 0 N w r_ C v 70 O o� 6 Z N Q �O W '00 C 0 000 O d 0 • L E QO �. ° > vv Co -0 O U O U N Y mak L E 01 al L_ LO E u° L O c. YV LO N D C 3 v T O v v Qa- O O Y > •j C O U O N C O O —'6"ry �— CN C p pq m T `Q •gip 3- 57 7L ° o N O '6 O O C � N 0 v OO O m `O O1..• �- Z .0 O N N L O_ O o� c -0 �" ar .Z� 00--Z � c -° " ar .O E E J O C 01 0 ram°c a) 7 �a) m 2; adv "o 3 �E nsc �o �_ Q L. c r aw u r O Q ` d1 aY E U ,O v C Lr O [O O p 025 c} 2C C� ° 4 > ' v ,C U po ', tial° I'D o o vv �c a�� 4) NE -b 0'�O �'$ SCC? N O O0. v° 5= N — --'aa)i •t om °o N E ° c a`>E > U O EadO UO rn0 c p — CCS -O O ¢ `U O O 3 E .o N O z �, C,'7 c1,1.. Q.. - '° 7 U ,O .T rL .ta._a vL C —E C N 5 HQ ° p 0 � O� C v O 7 O .m 0.07a� ^ U U- `O p Uw C N M V h. U' n m GNOHO dOl M a•ih5.. 10 Vd N O U CL O X C— a) O D•N z p •od o m I-- 0.5-0 O 1 O Q N O-0 z2E-oadE W O W C —a (D 0 t) T Z ��E_a-CO: Q 000<0 O o Q 4-- U 0 W CL IQ J adOH3 d01 co C a> L O mO P W vd O 3 �-- Y H UW UQ O� W z LU W ? UO J W ad W ~ Lu a ca �z z� J a J h KN W Vd z= LU Y V W ac Z=W O W Oar O N 0 N w r_ C v 70 O o� 6 Z N Q �O W '00 C 0 000 O d 0 • z O O z r LC LL z z W 0 W a N W Vi 3 °S oU a� N N oW oe m Uz N 0 U— pib O v C •N o yQ 0-(J) 0 _CEO c aL5 ad O -O-O D C N C ` a) =>d O a E U a) V SEN,= ~3°:F= z O Q U O z U m J Q Qom' W Q J 10 v 011 Ol � O W w Lr)^ — -0 M ,0 h - P P L,) ' w N W (,) Z M P � db �? crit 0 LU W Uz O, U OC O 6 � C � C„ 00 ' 0 y E oCw -0'u E O O N UCL -O ON O m rn U NO LCOU 30U a c � O 0 c-0 UOa) U U U O 00W3 O ° OT E C -"- 4} C a L& �L w k 13 IL c _ O c O U O E= N �U °Co — 2 � �o0 `, ad 6 OWN U� dki ° C U F= gaaaU0 4' O Q c p OU°8 co _0 5' a71 m O Oa71 tmO O)U 4cU c c' c c O 0) o�yrllD °o z m U S U 0 y .. CL Ot��: . 7 Nrne Z V7 U Q 0 co ` a L �. vv Co -0 O U L Q N Y mak L L c. YV p p; D C N O - — o O Y v C a TO pq 6 0 9 •gip o N C O O Q U C a ak CY CY' N L O_ 'U O` O 00 C O O C C 01 O O Q O 7 �a) N N L "o . 0 a) 9 L. c r Sb 0 - o� Q =~ `o °a� p pN ° E a > ' v v U po ', tial° �� o o vv �c a�� c 3 `c o u �'$ v o ac)E no v° 5= N — --'aa)i •t om °o oU C � 06 �� aeric > � oad E� C 0" N O j a E � O C O O ° p 0 � O� C v O 7 O .m 0.07a� �v U U U- `O p Uw C ° p O": O) v'':'N Q N V U' n 9b v NE LC E UR �E U ;Q Cd E aY U —'U ° U CY C OO C D. 6 ° N a) O r U „. U o- o_._ °a ._ oa r o m 0 o U oQ D O °'c° a) Q a�icc tr 0 adz S h rl 00 a. N z O O z r LC LL z z W 0 W a N W Vi 3 °S oU a� N N oW oe m Uz N 0 U— pib O v C •N o yQ 0-(J) 0 _CEO c aL5 ad O -O-O D C N C ` a) =>d O a E U a) V SEN,= ~3°:F= z O Q U O z U m J Q Qom' W Q J 10 v 011 Ol � O W w Lr)^ — -0 M ,0 h - P P L,) ' w N W (,) Z M P � db �? crit 0 LU W Uz O, U OC O 6 � C � C„ 00 ' 0 y E oCw -0'u E O O N UCL -O ON O m rn U NO LCOU 30U a c � O 0 c-0 UOa) U U U O 00W3 O ° OT E C -"- 4} C a L& �L w k 13 IL c _ O c O U O E= N �U °Co — 2 � �o0 `, ad 6 OWN U� dki ° C U F= gaaaU0 4' O Q c p OU°8 co _0 5' a71 m O Oa71 tmO O)U 4cU c c' c c O 0) o�yrllD °o z m U S U 0 y .. CL Ot��: . 7 Nrne Z V7 U Q 0 co ` a RESIDENTIAL BUILDING PERMIT APPLICATION CHECKLIST This checklist is for new dwellings, additions, remodels, and garages. The purpose is to show what you intend to build, where it will be located on your lot, and how it will be constructed. Residential permit application. I Washington State Energy & Ventilation Code forms I Two (2) sets of plans with North arrow and scaled, no smaller than Y4p = 1 foot: A site plan showing: 1. Legal description and parcel number (or tax number), 2. Property lines and dimensions 3. Setbacks from all sides of the proposed structure to the property lines in accordance with a pinned boundary line survey 4. On-site parking and driveway with dimensions 5. If creating new impervious surfaces, indicate measures utilized to retain stormwater on-site 6. Street names and any easements or vacations 7. Location and diameter of existing trees 8. Utility lines 9. If applicable, existing or proposed septic system location 10. Delineated critical areas boundaries and buffers I Foundation plan: 1. Footings and foundation walls 2. Post and beam sizes and spans 3. Floor joist size and layout 4. Holdowns 5. Foundation venting Floor plan: 1. Room use and dimensions 2. Braced wall panel locations 3. Smoke detector locations 4. Attic access 5. Plumbing and mechanical fixtures 6. Occupancy separation between dwelling and garage (if applicable) 7. Window, skylight, and door locations, including escape windows and safety glazing I Wall section: 1. Footing size, reinforcement, depth below grade 2. Foundation wall, height, width, reinforcement, anchor bolts, and washers 3. Floor joist size and spacing 4. Wall stud size and spacing 5. Header size and spans 6. Wall sheathing, weather resistant barrier, and siding material 7. Sheet rock and insulation 8. Rafters, ceiling joists, trusses, with blocking and positive connections 9. Ceiling height 10. Roof sheathing, roofing material, roof pitch, attic ventilation Exterior elevations (all four) with existing slope of the land in relation to all proposed structures I If architecturally designed, one set of plans must have an original signature I If engineered, one set of plans must have one original signature I For new dwelling construction, Street & Utility or Minor Improvement application City of Port Townsend Development Services Department 250 Madison Street, Suite 3 Port Townsend, WA 98368 (360) 379-5095 Fax: (360) 3444619 Washington State Energy Code (WSEC) 2001 Residential Construction Checklist Complete this form in addition to WSEC forms. Please answer the following questions: ±n O1*" a'New ConstrucIli oi or addition over 750 square feet t, o house and spot ventilation requirements, and show full WSEC compliance as a stand-alone project. A detached, habitable structure such as an Accessory Dwelling Unit regardless of size must also meet these requirements. House addition under 750 square feet Possible trade-offs are allowed with the existing building for WSEC compliance, such as increasing ceiling insulation. See WSEC component performance forms. NOTE: A house addition less than 500 sq. ft. does not require whole house ventilation. Spot ventilation is still required TYPE 0F HEATING -- Please check all that a m)lY: Electric Wall Heater � Baseboard Forced Air Ftlrna c ' Radiant Floor (Boiler) Other Non -Electric: ,w Propane: k.J Radiant Floor/Baseboard (Boiler) � LPG Stove ' LPG Furnace ' Other LPG J Heat Pump J Oil Furnace J Woodstove (can only be used as secondary heat source) VAPOR RETARDERS_ Vapor retarders shall be installed toward the warm surface as represented below. Select one option for floors, walls, and appropriate ceilings. • Floors: ly wood with exterior glue )as greater than or equal to 4 millimeter thick) • W:al'�ls:.� .. treater than or equal to 4 millimeter thick) backed batts i o -f °°reg61red where ventilation space averages greater than or equal to 12 inches above insulation rtbacked Batts A 1� -cater than or equal to 4 millimeter thick) o�w�ell�a illt sr±,*,°BA l http://ptimaging/DSD/Bpilding FormsBuildingPermitPacket/Application-Residential Energy Code Checklist.doc Page 1 of 2 TE :�Iype of ventilation used throu shout the hotlse� - w Integrated Opt(on` ' Exhaust Option Whole House Fan for "Exhaust Option": • In what room is your whole house fan located? eql< A1111� • What size is the whole house exhaust fan?50- CFM (1-2 bedroom house) <g 80-12 ]: (3 bedroom house) -150 CFM (4 bedroom house) 120-180 CFM (5 bedroom house) Note: the whole house fan shall be readily accessible and controlled by a 24-hour clock timer with the capability of continuous operation, manual and automatic control. At the time of final inspection, the automatic control timer shall be set to operate the whole house fan for at least 8 hours a day, and have a sone rating at 1.5 or less measured at 0.10 inches water gauge. Spot Ventilation: Source specific exhaust ventilation is required in each kitchen, bathroom, water closet, laundry room, indoor swimming pool, spa and other rooms where excess water vapor or cooking odor is produced. Bathrooms, laundries or similar rooms require fans with a minimum 50 cfm rating at 0.25 inches water gauge; kitchens shall have a fan with a minimum 100 cfm rating at 0.25 inches water gauge. Outdoor Air Inlets: Outdoor air shall be distributed to each habitable room by means such as individual inlets, separate duct systems, or a forced -air system. Habitable rooms include all bedrooms, living and dining rooms but not kitchens, bathrooms or utility rooms. Where outdoor air supplies are separated from exhaust points by doors, undercutting doors a minimum of/z inch above the surface of the finish floor covering, distribution ducts, installation or grilles, transoms or similar means where permitted by the Uniform Building Code. When the system provides ventilation through a dedicated opening, such as a window or through -wall vent, these openings must: • Have controlled and secure openings • Be sleeved or otherwise designed so as not to compromise the thermal properties of the wall or window in which they are placed. • Provide not less than 4 square inches of net free area of opening for each habitable space. Wh�tf inlet will be installed? (See figure below) all Ports http://ptimaging/DSDBuilding_Fonns/BuildingPemmitPacket/Application-Residential Energy Code Checklist.doc Page 2 of 2 C9 City of Port Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend WA 98368 (360) 379-5095 Fax (360) 344-4619 Washington State Energy Code 2006 Edition Climate Zone 9 - Type R-3 and R4 Changes for Single Family and Duplex Construction _ The following is a list of code changes that will effect construction of single family and duplex homes in Climate Zone 1. This is not a comprehensive list of changes. To see all the changes, download a new copy of the code and look for a vertical bar in the margin indicating a change in the code. Building Envelope: Prescriptive Options Table 6-1 • Option I, the U -factor for windows changed to U-.032. Glazing is limited to 10% of floor area. • Option II, the U -factor for windows changed to U-.035_ • Option IV, the U factor for windows changed to U-_035. There may be an increased use of window U -factor averaging when using the prescriptive method. Applicants may show compliance by providing area weighted average U -factor for all'of the windows. With a more stringent standard the use of averaging may increase_ The applicant must submit a detailed window, schedule demonstrating compliance. Component Performance Table 5-1 • The target window U factor changed to U-.035. • The target wall U -factor changed to U-.057. Doors: 602.6 Exterior Doors • One unregulated door up to 24 square feet is still allowed. • Glazed doors are considered to be windows. • All opaque doors must meet the door U -factor requirement_ In the past, any door could be called a window when included in the glazing percentage. Now, when using the prescriptive options, opaque doors must meet the U-0.20 requirement. An insulated fiberglass or thermally broken steel door will usually meet the U -factor requirement_ Single Rafter Joist: Table 6-1, footnote 3 Table 5-1, footnote 3 • If there is room in the joist for R-30 insulation, R-38 is required. This applies to all single rafter joist 13" or greater in depth_ • R-30 single rater joist now limited to 500 square feet of roof area. Additional rafter area must use R-38 insulation. P The following table shows typical insulation requirements for single rafter joist If the table notes R-38, then R-38 is required_ Footnote 3, Table 6-1 or 6-2 Prescriative Rafter Insulation Based on Fiberalass Batts A take off noting rafter area will be required. Identical rules are included in 5-1. They will be incorporated into the UA trade off spreadsheet. 502.4A Recessed Lighting Fixtures: • Must now be tested for air leakage using ASTM E283 • A gasket or caulking must seal the fixture to the drywall • Other options for fixture air_sealing, including field inspection and a seated box have been deleted. This has been an option in Washington since 1991. California mandated testing for air tight can lights two years ago. Since then, every major manufacturer has come on board. The fixtures are readily available. Look for the label in the can. If the can is not labeled, it does not comply. 505.3 Outdoor Lighting: • Requires high efficiency lighting or controls for all porch lighting • High Efficiency Luminaire is defined in Chapter 2. Typically requires a pin based compact fluorescent fixture • As an exception to the High Efficiency Luminaire, a motion sensor + photo daylight control may be used. 505.4 Linear Fluorescent Fixtures: • This rule applies to typical fluorescent tube fixtures • Linear fluorescent fixtures must be fitted with T-8 (1" diameter) or smaller lamps (but not T 10 or T-12 lamps) Max depth with f=irst Over Nominal Actual 1 "ventilation 500 SF 500 SF R -value R -value 2X10 9 1J9" w. 8114" _ .........W_. RSO HD2 _..-_.._......_ . Mote' 2X12 11 114" 10 114" R-30 R-38 HD2 2X14 13 119" 13114" R-38 ..A� R-38 I -Joist 81 f2" .�..._.-__. R-30 HD ,�... Note ' _._...�. t -Joist _9112" 11 718'- _...._� 10 718" R-30 R-38 HD2 Woist 14" 13" R-8 R-38 1 -Joist 16" 15" R W R-38 Note' Upsize joist or provide an alternative method meeting U-_027. HD2 Refers high density fiberglass batt or equivalent_ A take off noting rafter area will be required. Identical rules are included in 5-1. They will be incorporated into the UA trade off spreadsheet. 502.4A Recessed Lighting Fixtures: • Must now be tested for air leakage using ASTM E283 • A gasket or caulking must seal the fixture to the drywall • Other options for fixture air_sealing, including field inspection and a seated box have been deleted. This has been an option in Washington since 1991. California mandated testing for air tight can lights two years ago. Since then, every major manufacturer has come on board. The fixtures are readily available. Look for the label in the can. If the can is not labeled, it does not comply. 505.3 Outdoor Lighting: • Requires high efficiency lighting or controls for all porch lighting • High Efficiency Luminaire is defined in Chapter 2. Typically requires a pin based compact fluorescent fixture • As an exception to the High Efficiency Luminaire, a motion sensor + photo daylight control may be used. 505.4 Linear Fluorescent Fixtures: • This rule applies to typical fluorescent tube fixtures • Linear fluorescent fixtures must be fitted with T-8 (1" diameter) or smaller lamps (but not T 10 or T-12 lamps) TABLE 6-1 PRESCRIPTIVE RE Ul E T " F P R OCCUPANCY CLIMATE ZONE 1 Glazing (ylazin U -Factor Wall'? Wall-, Wall• e Area : ..__ s 2 Vaulted Above int° ext' " Slab ®ptFon Ceilin® 3 Flair" on % of Floor Vertical Overhead" U -Factor Ceiling Grade Below Below Grade ., -i.32 Grade Grade 10°/ b 32 058 0.20 R -W R 30 R15 I. ® R-15 R-10 R-30 R-10 11.` 15°7® 0.35 0.58 0 20 R-38 R-30 R-21 R-21 R-10 R-30 R-10 Ill. 25% OAO 4.58 .2 IJ R-301 R-21 ! R-15 R-10 R-301 R-10 Group R-1 U=0.031 U=0.034 U=0.057 .02 and R-2 9 Occupand es Ong IV. Unlimited .... 0.35 -, ._. 0.58 _... _ 0.20 R-38 R`30 R-21 R-21 R-1.._._ w...3 0 0 R-30 R-10 Group R-3 and R-4 Occupanci � Onl V. Unlimited 0.35 0.58 0.20 R-381 -30 f R-21 I R-15 R-10 IJ R-10 Group R-1 U=0.031 U=0.03U=0.05/ U=0.02 and R-2 Q Oaaipand _�..wes Only ....... .... ...... Reference Case _... .... 0_ Nominal R -values are for wood frame assemblies only or assemblies built in accordance with Section 601.1. 1. Minimum requirements for each option listed. For example, if a proposed design has a glazing ratio to the conditioned floor area of 13%, it shall comply with all of the requirements of the 15% glazing option (or higher)_. Proposed designs which cannot meet the specific requirements of a listed option above may calculate compliance by Chapters 4 or 5 of this Code. 2. Requirement applies to all ceilings except single rafter or joist vaulted ceilings complying with note 3. Adv` denotes Advanced Framed Ceiling. 3. Requirement applicable only to single rafter or joist vaulted ceilings where both (a) the distance between the top of the ceiling and the underside of the roof sheathing is less than l2 inches and (b) there is a minimum 1 -inch vented airspace above the, insulation. Other single rafter or joist vaulted ceilings shall comply with the "ceiling" requirements. This option is limited to 500 square feet of ceiling area for any one dwelling unit. 4. Below grade walls shall be insulated either on the exterior to a minimum level of R-10; or on the interior to the same level as walls above grade_ FxveHor insulation installed on below grade walls shall be a water resistant material, manufactured for its intended use, and installed according to the manufacturers specifications. See Section 60.2. 5. floors over crawl spaces or exposed to ambient air conditions. 6. Required slab perimeter insulation shall be a water resistant material, manufactured for its intended use, and installed according to manufacturers specifications. See Section 602.4. 7. Int. denotes standard framing 16 inches on center with headers insulated with a minimum of R-10 insulation. S. ?his wall insulation requirement denotes R-19 wall cavity insulation plus R-5 foam sheathiiig- 9. Doors, including all fire doors, shall be assigned default U -factors from Table 10-6C. 10. Where a maximum glazing area is listed, the total glazing area (combined vertical plus overhead) as a percent of gross conditioned floor area shall be less than or equal to that value_ Overhead glazing with U -factor -of U=0.40 or less is not included in glazing area limitations. 11. Overhead glazing shall have U -factors determined in accordance with NIFRC I00 or as specified in Section 502.1.5. 12. Log and solid timber walls with a minimum average thickness of 3.5" are exempt from this insulation requirement. Chapter 9 Prescriptive Space bleating System Sizing Deleted. See IRC U1401.3.• 503.2.2 Size limited to 1511°% of heating load Replaced by IRC Section M1401.3. heating and cooling equipment shall be sized based on building loads calculated in accordance with Air Conditioning Contractors of America Manual J or other approved heating and cooling calculation methodologies. Manual J is a heating and cooling heat load calculation method. This method takes some training. See their web site for details_ ht p j .g . wr; iteg ! Fh/ ma ti l°/ WSU has developed a spread sheet for WSEC Chapter 5 code qualification. We call this the CPworksheet. This spread sheet will also provide a simple heating system size calculation that is roughly equivalent to manual J. Limit the use of this spread sheet to electric resistance or combustion equipment sizing. Do not use this spread sheet to size heat pumps or air conditioners. This spread sheet is available on our web site. Washington State University Extension Energy Program Energy Code Support Email. gner„� node @nqergywsu.edu Phone: 360 956-2042 • Gary Nordeen. • Mike McSorley • Chuck Murray Residential Energy Code Support • Energy and Ventilation Code Text • Residential Component Performance Worksheets • Residential Builders Field Guide ht�t ./ .ener�r :wvs r.ertu/c4 eLcode sKrpport. f For Non residential energy code support, Visit the NEEC web site. tett �:��ra�e.rret/resourceslr�au rce.htmt ,CHI rod Receipt Number: pa -(Pa j" genpmtrreceipts Page 1 of 1 .. Previous "ent Histo Rett # fto l t Date Fee 1)6irf tion Amouht PaWrmlt pa Ch�eck payroent Ithd : Mimber Amount ,.., CHECK 1005 $ 3.45 Total $3.45 genpmtrreceipts Page 1 of 1 go R1 yrs,}* wn�+ receipt l)aW 0611812008 per inIt t# Parcel BLD08-014 944700101 Receipt 08-0205 08-0205 08-0205 08-0051 08-0205 08-0205 08-0205 08-0205 08-0205 08-0205 Paym enit Method CHECK Receipt Number: 08-0585 a., Payer/Payee Homes Original Fee Arnount Fee Fee 'Description Amount Paid Balance Inspection Fee - Miscellaneous/Hou $50.00 $50.00 $0.00 Total: $50.00 genprrtr receipts Page 1 of 1 Previous Payment istor, Receipt Date, Fee Description Amount Pold Permit ## 02/2212008 Building Permit Fee $1,452.95 BLD08-014 02122/2008 Energy Code Fee -New Single Family Unit $100.00 BLD08-014 0212212008 Mechanical Permit Fee per Dwelling Unit - 1 $150.00 BLD08-014 0111812008 Plan Review Fee $150.00 BLD08-014 02/2212008 Plan Review Fee $794.42 BLD08-014 02/22/2008 Plumbing Permit Fee per Dwelling Unit - Ne $150.00 BLD08-014 02/2212008 Record Retention Fee for Building Permit $10.00 BLD08-014 02/22/2008 Site Address Fee $3.00 BLD08-014 02/22/2008 State Building Code Council Fee $4.50 BLD08-014 02/2212008 Technology Fee for Building Permit $29.06 BLD08-014 Check Paym ant Number Amount 1516 $ 50.00 Total $50.00 genprrtr receipts Page 1 of 1 c�+ Receipt Number. WAE genpmtrreceipts Page 1 of 1 ocelpt Date., 0212212008 Cashier. SFOSTER rm,it # Parcel LD08-014 944700101 LD08-014 944700101 LD08-014 944700101 LD08-014 944700101 LD08-014 944700101 LD08-014 944700101 LD08-014 944700101 LD08-014 944700101 LD08-014 944700101 Fee Description Receipt Number: Payer/Payees Name: TIERRA INVESTMENTS LL Plan Review Fee Technology Fee for Building Permit Energy Code Fee - New Single Famil State Buiiding Code Council Fee Plumbing Permit Fee per Dwelling l Mechanical Permit Fee per Dwelling Building Permit Fee Record Retention Fee for Building P Site Address Fee Previs Pziyment History _ 'ecelpt # Receipt late Fere Description 8-0051 01/18/2008 Plan Review Fee ayrnent Check Payment letho,d Numbermoi unt HECK 106 $ 2,693.93 Total $2,693.93 w t' Original Fee Amount Fee Amount Paid Balance $944.42 $794.42 $0.00 $29.06 $29.06 $0.00 $100.00 $100.00 $0.00 $4.50 $4.50 $0.00 $150.00 $150.00 $0.00 $150.00 $150.00 $0.00 $1,452.95 $1,452.95 $0.00 $10.00 $10.00 $0.00 $3.00 $3.00 $0.00 Total: $2,693.93 Am ouint Paid Permit $150.00 BLD08-014 genpmtrreceipts , Page 1 of 1 genpmtrreceipts Page 1 of 1 Receipt Number. 08-005f WA�� )ecelotDate,. 01/11112008 Cashier: SWASS "I Payer/Payee: Name: TIERRA INVESTMENTS LLC Original fee Amount Pee ormit# Parcel Poo Description Amount Paid Balance LD08-014 944700101 Plan Review Fee $944.42 $150.00 $794.42 Total: $150.00 Previous "a m e t History ecelpt 0, Receipt hate Fee Description Amount Paid Permit aym,o nt Check Payment letin d Number Amount HECK 1005 $ 150.00 Total $150.00 genpmtrreceipts Page 1 of 1 Lu Lu a ZO~L�Q� 3Qi M OIL OPI% HG{LU LjjZ0 LU �O IL U z Q Z a5:Z3: W U) UZf0at ioar^i N 0 N O W H J a H LL LL W U LL N W U H W W w R LU LU a) c v 0 ¢ a O L ¢ O U� E pZ ` a � Z o o g E } n g �LU _m L N LU U 0) sc— 2 ¢ u =3 a o o .0 cn� v mrn -v a) o _U 41 a s w p -Jw th � 3LL Z M O' 3-0,00 =3= 3 H W w w w o ff Y 2 ° ao o as mLL p� Nu pp �� t z gw C ` d ..., v C m a O { �w omaA C Z LU UJ Ln .m a O ¢ 0 CYZ Ln C) LLI LU aJ L fo 4, 41 t C 41LU ce m LLl w N p O E V U W LLJ m ¢ a cr Z p10Z c a ZZ� 0) E c v a gza LU m 2: W ;5_ J awi � 0 cn v$ Z i0 a a 3 av COCp � vi z ¢ E� ° =wz LU LU' 0 "F- 0 iJi QC Ly H °' Z LLJ 3 Page 1 of 1 A - Scottie Foster From: Francesca Franklin Sent: Tuesday, March 31, 2009 3:15 PM To: John Watts Cc: Scottie Foster; Kenneth Clow; John McDonagh Subject: RE: Pete Goughnour John, Latecomer due for 1977 Eddy Street: Latecomer Fee 564.20 Plus Admin Fee 56.42 Total Due 620.62 Latecomer Due for 1925 Eddy Street: Latecomer Fee 564.20 Plus Admin Fee 56.42 Total Due 620.62 Grand Total Due for both residences: $1,24.1.24 Check needs to be made out to: City of Port Townsend Thank you. Francesca From: John Watts Sent: Tuesday, March 31, 2009 2:56 PM To: Francesca Franklin Cc: Scottie Foster; Kenneth Clow; John McDonagh Subject: Pete Goughnour I spoke with him this afternoon. He now knows there are 2 unpaid L/C. He said he would write a check to us when I give him the exact amount he owes. FF — please give me the exact amount per property. I'll tell him to mail to DSD. If not received in 4-5 days, please let me know Ken and I agree that the occupancy permit for the pending closing should issue now (we don't hold it up pending payment). If Pete does not pay the 2 L/C, we can revoke permits, and notice to title the other properties Pete owns in the area, etc. John Watts City Attorney - City of Port Townsend 250 Madison Street, Suite 2 Port Townsend, WA 98368 Telephone: 360/379-5048 Fax: 360/385-4290 3/31/2009 Pagel of 2 Scottie Foster From: Francesca Franklin Sent: Tuesday, March 31, 2009 4:11 PM To: Scottie Foster Subject: FW: Latecomer Fees FYI — you were not on this latest e-mail. F2 From: John Watts Sent: Tuesday, March 31, 2009 4:08 PM To: Pete Goughnour (petegoughnour@yahoo.com) Cc: Francesca Franklin Subject: Latecomer Fees Pete —the total due is $1,24.1_.24 (per below). The admin. fee is 10% of the 1/c amount, and attaches to every latecomer charge (not just these two). Please make your check payable to the City of Port Townsend, and mail to City of Port Townsend 250 Madison Street, DSD Dept. Port Townsend WA 98368 Please write on the check ("latecomer"). Thanks and let me know any questions. John Watts City Attorney - City of Port Townsend 250 Madison Street, Suite 2 Port Townsend, WA 98368 Telephone: 360/379-5048 Fax: 360/385-4290 From: Francesca Franklin Sent: Tuesday, March 31, 2009 3:15 PM To: John Watts Cc: Scottie Foster; Kenneth Clow; John McDonagh Subject: RE: Pete Goughnour John, Latecomer due for 1977 Eddy Street Latecomer Fee 564.20 Plus Admin Fee 56.42 Total Due 620.62 Latecomer Due for 1925 Eddy Street: 3/31/2009 Page 2 of 2 Latecomer Fee 564.20 Plus Admin Fee 56.42 Total Due 620.62 Grand Total Due for both residences: $1,241.24 Check needs to be made out to: City of Port Townsend Thank you. Francesca 3/31/2009 VoRT CITY OF PORT TOWNSEND ` DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT CALL THE INSPECTION LINE AT 360-385-2294 BY 3:00pm THE DAY BEFORE YOU WANT THE INSPECTION. FOR MONDAY INSPECTION, CALL BY 3:OOPM FRIDAY. DATE OF INSPECTION: F PERMIT NUMBER: oe -0 SITE ADDRESS: q Y"'- CONTACT PERSON: PHONE: TYPE OF INSPECTION: ❑ APPROVED ❑ APPROVED WITH CORRECTIONS ^° Ok to proceed. Corrections will be checked at next inspection Ins ector �� P __. a .. l.___.. .-_. _ ._._........_..... Date � Acknow ed en er t. Date ❑ NOT APPROVED Call for re -inspection before proceeding. 211 Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection. YORT CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT CALL THE INSPECTION LINE AT 360-385-2294 BY 3:00pm THE DAY BEFORE YOU WANT TH NS'PFCTION. FOR MONDAY INSPECTION, CALL BY 3:OOPM FRIDAY. DATE OF INSPECTION: PERMIT NUMBER: t7— y SITE AI)DRESS:_ CONTACT PERSON: TYPE OF INSPECTION: f, PHONE: 11 APPROVED 0 APPROVED WITH 11 NOTAPPROVED CORRECTIONS Ok to proceed. Corrections will beinspection be checked at next inspection proce ding. TM Inspector Z (i Date . . . ....... Acknowledgement — ----------- - ...... . . . ...... ... . ......... .. . ..... ...... ..... . Date Approved plans and permit card must be on-site and available at time of inspection. A re- inspection fee may be assessed if work is not ready for inspection. . � � \ � � � /. ���/ � ;� /. � � ; a \ � � � � \ �%�,. � , ( }� � .� � ?� � � � \ � \ «�\z2� .--7 t fill .--7 " CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: 12711 PERMIT NUMBER: 61'n o"w — e SITE ADDRESS: ',� %%�1 PROJECT NAME: CONTRACTOR: CONTACT PERSON: _ PHONE: ......IT ... TYPE OF INSPECTION: _.....� `"°° _ _........ r..... ... .. ------ .. .......... .......�... ..�.�. ��� �.......... pp ate.. ❑ APPROVED ❑ APPROVED WITH ❑ NOT APPROVED CORRECTIONS Ok to proceed. Corrections will be c'4nsj)6 tion before checked at next inspection proceeding. Ins ector a i���, �` .. R Date P � .m . — v. m. ...... _..__ ....? .. ...... Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection. AT CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION:�� N : SITE ADDRESS: PROJECT NAME: CONTRACTOR: CONTACT PERSON:PHONE: TYPE OF INSPECTION: .._ ... �az. c:.A�"_.W a wm. .................wmw 4';�71 " I l a. / "," tire.: i L, w.�_ ', ❑ APPROVED ❑ APPROVED WITH A,,, OT APPROVED CORRECTIONS r Ok 4, proceed. Corrections will be Call for re -inspection before he lie at next inspection laroce':ding. Date Inspector -� Approved plans and permit card must be on .site th<available at time erf'inspection. A re -inspection fee may be assessed if work is not ready fbr inspection. YOST CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT ww For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION PE 11 �Vl IT N U A4 11 E R. SITE ADDRE SS: ",CCT NAME: CONTRACTOR: . . ...... . ........ . ...... - - — -, -.wH CONTACT PERSON: PHONE: TYPE OF INSPECTION: -Ti-kAL, .... . - - - - --------- - — ---- - ----------- - . ....... . . .... ------- - ------- - - - ------------- - ...---- ............. ...... — --- ------ - ------- . .. . ............. ------ E k To U APPROVED L1 APPROVED WITH I INOT APPROVED CORRECTIONS Ok to proceed. Correctionswill l'a checked at next inspection firriceedbig, Inspector y Date Approved plans and permit card must be on-site and available at time of'inspection. A re-inspection.fee may be assessed V'work is not ready fijr inspection, VORT CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT WA For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION ,� _ T NUMBER: SITE ADDRESS:'" p PROJECT NAME: 4#4 IN ICONTRACTOR:. CONTACT PERSON: PHONE: TYPE OF INSPECTION: kA ... ...... w _................ m it*. 1I ZIT// 11d � �_ a� t�, . ' m')7, ,, ❑ APPROVED ❑ APPROVED WITH ❑ NOT APPROVED CORRECTIONS, Ok to proceed. Corrections will be t .�pl"r e���iwr1°i�ati'rr'e checked at next insfiection proceeding. Inspector � I Cf/ i' . ? �- Date Approvedplans andpermit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if `work is not ready for inspection. For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: PE IT NUMBER: kw SITE ADDRESS: PROJECT NAME. ®—� d CONTACT PERSON: ICA � f JIrl k PHONE: G 1 I ❑ APPROVED ❑ APPROVED WIT '1. t')T APPROVED CORRECTIONS Ok to proceed. Corrections will be Call for re -inspection before checked at next inspection proceeding. Inspector Date �.....: . Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection. Inspection Report ._.. Project �HgLd Permit # , Date Inspector Inspection & Notes v � G/ �►�ir� Ol�lv 4 i A,.j N� M.mm ..._ _ ... w....... _.__.._._� ................. _ ....._ CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: PERMIT NUMBER: . ......... – — ­- - SITE ADDRESS: ............................ . ............................................. . . ........................................... PROJECT NAME: –CONTRACTOR: CONTACT PERSON: PHONE: TYPE OF INSPECTION: zz "w Wit/q ............. L 0 APPROVED [I APPROVED WITH NOT APPROVED CORRECTIONS Ok to proceed. Corrections will lie Call for re -inspection before checked at next inspection proceeding. Inspector (AJDate 6_1�1..r --- . . . ................ ------ . . . . . . . . . ................. Approvedplans and permit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection. VORT CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT yt r . INSPECTION REPORT For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION. �, PERMIT NUMBER: SITE ADDRESS: (q( f 7 �l i) �. �.......___ .,­......._ PROJECT NAME: CONTACT PERSON: CONTRACTOR: TYPE OF INSPECTION::; ,r tj a kb PHONE: ❑ APPROVED ❑ APPROVED WITHNOT APPROVED CORRECTIONS Ok to proceed. Corrections will lie I'::_I for re -inspection before checked at next inspection proceeding. Ins ector Date - - Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection. 90nr CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT +^ For inspections, call the Inspection Line at 360-385-2294 b 3:00 PM the da before you want P � P Y Y the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: l � PERMIT NUMBER: d'- SITE ADDRESS: 77 PROJECT NAME:/ �Y6,12,& . CONTRACTOR: CONTACT PERSON: PHONE: TYPE OF INSPECTION: ��Lt�1�J�1�.1 s -��✓t � -(a —�9 ❑ APPROVED ❑ APPROVED WITH NOT APPROVED CORRECTIONS Ok to proceed. Corrections will be C:ai ":ar re -inspection before checked at next inspection procce I . Inspector'. ��...:.�.. �.................. Date .....� }.... , .... Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection. 05104/2008 11:01 253$577533 HODGE ENGINEERING PAGE 01/03 e FA'/"\/TKANSMiTT,L Fax To.- City of Dort Townsend Department of Conununity Development (360) 344-4619 Attn-. Wade, Building Inspector Permit ## 08-014 Engineering Letter # 8387 (3) Pages including ever. Thank you, John Gabe Spruell Engineering Support Department :-lodge Engineering, INC. Ply. 253-857-7055 Fax: 253-857-7599 6/4/08 7C.)55 � , ( 34 fi r- 06/04/2006 ZT:ei 2539577599 HODGE ENGINEERING PAGE 02/03 RE: MX 2&h St, port QrCllard Hodge Eng. Project ROG13 Reality Homes plan 1575 Cantilevered Bay Window To Whom it May Concern: GA -08 Letter # 8387 I have provided the lateral lead engineering for the Reality Homes plan 1579 for Reality Homes. Gravity load engineering by others- ] have reviewed the floor framing layout provided by Huttig Building Supply - The floor framing layout and members appear adequate and are compatible with my lateral engineering. See attached plan view with the cantllevered floor framing at the front bay window. me with any questions regarding this project. om i a s[iginwr of record and regards his engin e A 'ng only. This letter the of trr � raguirernenta, Any schcdulc or, cmi irnpact is " r"ponsibility r s ar "rl B to has ft final authority to allow field changes to approved This er ria : > tr'onically in accordance with WAC 195 2' 9 and Ghepter Igo oEngineering,cInc. Nae d0�° ` � John V._ modg �� P. E. u6ox Jutm Arae V ate, Ai. (xag Max -ha , WA " -3,1 r>85'7,,J7055 Fax (253) 857„`7599 06/04/2008 11:01 2538577599 FUDGE ENGINEERING PAGE 03/03 IVA= Wok" :Aa Nffiv�0 90-6997cm '-31nv9 Tiu NNW -mmnos v to/a/v 1A11V 110®d/b, :2iva k " p 11 IN H 9 o j 1 1 a 11; jai 1 J 3 R P H lit I fill. "9F' CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT WA For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION SITE ADDRESS: PROJECT NAME: CONTACT PERSON: TYPE OF INSPECTION:w �T NUMBER: CONTRACTOR: PHONE: ❑ APPROVED V' APPROVED WITH ❑ NOT APPROVED 4"f."O1IR1 CT10 S Ok to proceed. Corrections will be Call for re -inspection before checked at next inspection proceeding. Inspector Date , �r _ .....rr_ ............ .... _.._ Approved ple arnd permit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection. VOAT CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT s : INSPECTION REPORT 4 � J tiµ For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want the inspection. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: �{ `I QZS PERMIT NUMBER: SITE ADDRESS: 4 l'� _. PROJECT NAME: CONTRACTOR: CONTACT PERSON: PHONE: TYPE OF INSPECTION:P '6t�� .� �.. , t�� � i V' ------------ f 0 IJ ❑ APPROVED I"PRON11CI) WITHNOT APPROVED XRRECTIONS ,,< 'NOT to proceed. Corrections will be Call for re -inspection before checked at next inspection proceeding. P " Ins ector ... Date _....... , _ ....w... Approved plans andpermit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection. ' CITY OF PORT TOWNSEND DEVELOPMENT SERVICES DEPARTMENT INSPECTION REPORT For inspections, call the Inspection Line at 360-385-2294 by 3:00 PM the day before you want ti w i�a:SIaecti+a n. For Monday inspections, call by 3:00 PM Friday. DATE OF INSPECTION: PERMIT NUMBER: Ar:) � 11 SITE ADDRESS: u ; PROJECT NAME: CONTRACTOR: CONTACT PERSON: PHONE: TYPE OF INSPECTION,°� ........__ .............. ...... W d r ow„ ........ r.:II k. r 'i c, 4� w N., ,.q_�'\ ❑ APPROVED " A 1'1 ItdlVE1) "4VII' 11 11 NOT APPROVED OItltlaC:`"(IONS ;�1( to proceed. Corrections will be Call for re -inspection before u" >r1'1�b lelY at next inspection pceeli�a8 w• Inspector Date - Approved plans and permit card must be on-site and available at time of inspection. A re -inspection fee may be assessed if work is not ready for inspection.