Loading...
HomeMy WebLinkAboutBLD08-046 (oversize drawings in storage)I?OFIT p BUILDING PERMIT ` City of Port Townsend Development Services Department TWA 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360)379-5095 Project Information Permit # BLD08-046 Permit Type Commercial Tenant Improvement Project Name PSE TI Site Address 181 QUINCY Parcel # 996700101 Project Description Tenant improvement for Puget Sound Energy Names Associated with this Project License Type Name Contact Phone # Type License # Applicant Puget Sound Energy Fee Information Project Valuation $13,300.00 Building Permit Fee 237.25 Plan Review Fee 154.21 State Building Code Council Fee 4.50 Technology Fee for Building Permit 5.00 Record Retention Fee for Building 10.00 Permit Total Fees $410.96 Project Details Office tenant improvement @20% Exp Date 1,900 SQFT Ca11385-2294 by 3:00pm for next day inspection. Permits expire 180 days from issuance if work is not commenced, or if work is suspended for a period of 180 days. Work is verified by obtaining a valid inspection. The granting of this permit shall not be construed as approval to violate any provisions of the PTMC or other laws or regulations. I certify that the information provided as a part of the application for this permit is true and accurate to the best of my knowledge. I further certify that I am the owner of the property or authorized agent of the owner. Print Name � � � L J� Date Issued: 04/02/2008 j1.� I Issued By: FRONTDESK CITY OF PORT TOWNSEND T PERMIT ACTIVITY LOG PERMIT # �.w. Z� i �"� _ DATE RECEIVED SCOPE OF WORK: 7--7-9,osl b� ponr r� City of Port Townsend Development Services Department 250 Madison Street, Suite 3 A Port Townsend WA 98368 WA 360-379-5095 Fax 360-344-4619 REVISION TO BUILDING PERMIT QRevision # OWNER:P�jcSITE ADDRESS: Total Value of Revision: $ t�b Impervious Surface Change? ❑ Yes t Revisions require 2 sets of plans and a written scope of workthat fully describes the proposed change plus any additional information that will be of assistance in issuing your revision. If your plans were stamped by a design professional, all revision submittals require a stamp with a wet signature. Be aAare that changes to the existing approved plans may also require Lou to revise your original building permit application (lot coverage, impervious surface, structure square footage, etc.) and energy code documents (changing windows, heat source, etc.) to conform to your proposed changes. Scope of work: y. • ��' , Date OFFICE U I.,Y: Submittal , te. Two sets of plans for revision: Approval of engi e rg "¢� r t °nal p engineered): ❑ Yes ❑ No ❑ NA PADSDDepartment FormMuilding Forms\Appl ication-Revis ion. doc O O z LL G W uW O co ugIL IL J a IL Q N z V oZ ao U J o m (1) w O U Z EL Q N z 0a 0 w= LLD Q Q N Q LU z Q oW- � a a� U ma 2 Q F 111 F- a m 00 0 0 N N � 0') Q O O J H Z Q lil a p U z O O H IL t5 00 0 0 N N O v O c4 v 0 0o 0 J m O z W IL 1-1 0 0 rn rn O Z J W a a w a> a. E z ° 0 CL H E U D � C co H Z ~ d' O w U Z 0 O J H a U W 0 U O a U) z z W g O U w Q 0 IL cn Z z O V w IL CO z z w O U IL U) z z O U W IL co z O Z W Z LU ZO n w to �: Q Z w 5 J Z z O H U w IL z a 0 N Z N co LL O �a M C O J M a0 U � Z 00 F- w U a W N W z W Z U Q w Ix F' W W co 00) w D d' m OU) W D w w Z O F- U w 0- U) Z Chapter 8. Special Rooms and Spaces ICC/ANSI A117.1-2003 803.5 Coat Hooks and Shelves. Accessible coat hooks provided within the room shall accommodate a forward reach or side reach complying with Sec- tion 308. Where provided, a shelf shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the floor. 804 Kitchens and Kitchenettes 804.1 General. Accessible kitchens and kitchen- ettes shall comply with Section 804. 804.2 Clearance. Where a pass -through kitchen is provided, clearances shall comply with Section hereq ,l,shaped kitchen is provldq, cleat `''§"'s'-"h comply with section 804.2.2. EXCEPTION: Spaces that do not provide a cook - top or conventional range shall not be required to 1--wmr)iv with Section 804.2. 804.2.1 Pass -through Kitchens. In pass - through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 40 inch- 1015 (a) 80 es (1015 mm) minimum. Pass -through kitchens shall have two entries. 804.2.2 U-Shaped Areas. In kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, countertops, ap- pliances„ or walls within kitchen work areas shall be 60 inches (1525 mm) minimum. 804.3 Work Surface. Work surfaces shall comply with Section 802. EXCEPTION: Spaces that do not provide a cook - top or conventional range shall not be required to provide an accessible work surface. Sinks. Sinks shall comply with Section 606. 804.5 Storage. At least 50 percent of shelf space in cabinets shall comply with Section 905. 804.6 Appliances. Where provided, kitchen ap- pliances shall comply with Section 804.6. $04.6.1 Clear floor Space. A clear floor space complying with Section 305 shall be provided at each kitchen appliance. Clear floor spaces are permitted to overlap. Fig. 804.2.1 Pass -through Kitchen Clearance IWO (b) Chapter 3. Building Blocks rn (h) ICC/ANSI A117.1-2003 304.3.2 T-Shaped Space. The turning space 1 /2 shall be a T-shaped space within a 60-inch 13 (1525 mm) minimum square, with arms and base 36 inches (915 mm) minimum in width. Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction, and the base shall be clear of obstructions 24 inches (610 mm) minimum. The turning space shall be permitted to include knee and toe clear- 1/ -1/ ance complying with Section 306 only at the end 6.4-13 2 of either the base or one arm. 1 304.4 Door Swing. Unless otherwise specified, doors shall be permitted to swing into turning -,spaces. n . 305 Clear Floor Space Fig. 303.3 Beveled Changes in Level 60 min 1525 I r (a) Circular 60 min b 1525 r----------- I c I I co0)Ea I I M O •U- 24 min F_ 610 I l I I I i _L------ 36 min 12 min 915 12 min 305 305 (b) T-shaped Fig. 304.3 Size of Turning Space 305.1 General. A clear floor space shall comply with Section 305. 305.2 Floor Surfaces. Floor surfaces of a clear floor space shall have a slope not steeper than 1:48 and shall comply with Section 302. 305.3 Size. The clear floor space shall be 48 inches (1220 mm) minimum in length and 30 inches (760 mm) minimum in width. 48 min 1220 F. —-.--� d I L �._J Fig. 305.3 Size of Clear Floor Space 305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor space shall be permitted to in- clude knee and toe clearance complying with Sec- tion 306. 305.5 Position. Unless otherwise specified, the clear floor space shall be positioned for either for- ward or parallel approach to an element. 305.6 Approach. One full, unobstructed side of the clear floor space shall adjoin or overlap an accessi- ble route or adjoin another clear floor space. 304.3.1 Circular Space. The turning space 305.7 Alcoves. If a clear floor space is in an alcove shall be a circular space with a 60-inch (1525 or otherwise confined on all or part of three sides, mm) minimum diameter. The turning space additional maneuvering clearances compilying with shall be permitted to include knee and toe clear- Sections 305.7.1 and 305.7.2 shall be provided, as ance complying with Section 306. applicable. 8 ICC/ANSI A117.1-2003 Cha Ater 3. Building Flocks 301 General 301.1 Scope. The provisions of Chapter 3 shall ap- ply where required by the scoing provisions adopted by the administrative authority or by Chap- ters 4 through 10. 302 Floor Surfaces 302.1 General. Floor surfaces shall be stable, firm, and slip resistant, and shall comply with Section 302. Changes in level in floor surfaces shall comply with Section 303. 302.2 Carpet. Carpet or carpet tile shall be securely attached and shall have a firm cushion, pad, or backing or no cushion or pad. Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. The pile shall be 1/2 inch (13 mm) maximum in height. Exposed edges of carpet shall be fastened to the floor and shall have trim along the entire length of the exposed edge. Carpet edge trim shall comply with Section 303. 1/2 max 13 Fig. 302.2 Carpet on Floor Surfaces 302.3 Openings. Openings in floor surfaces shall be of a size that does not permit the passage of a 1/ inch (13 mm) diameter sphere, except as allowed in Sections 407.4.3, 408.4.3, 409.4.3, 410.4, and 805.10. Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. 303 Changes in Level 303.1 General. Changes in level in floor surfaces shall comply with Section 303. 303.2 Vertical. Changes in level of 1/4 inch (6.4 mm) maximum in height shall be permitted to be vertical. Chapter 3. Building Blocks predominant direction of travel pnmdi�ulartcr direction of travel 1/ max 13 Fig. 302.3 Openings in Floor Surfaces 1/4 max 6.4 _..........................m _. Fig. 303.2 Vertical Changes in Level .303.3 Beveled. Changes in level greater than 1/4 inch (6.4 mm) In height and not more than 1/2 inch (13 mm) maximum in height shall be beveled with a slope not steeper than 1:2. 303.4 Ramped. Changes in level greater than 1/2 inch (13 mm) in height shall be ramped and shall comply with Section 405 or 406. 304 Turning Space 304.1 General. A turning space shall comply with Section 304. 304.2 Floor Surface. Floor surfaces of a turning space shall have a slope not steeper than 1:48 and shall comply with Section 302. 304.3 Size. Turning spaces shall comply with Sec- tion 304.3.1 or 304.3.2. 7 ICC/ANSI All 7.1-2003 Chapter 9. Built-in Furnishings and Equipment Chapter 9. Built-in Furnishings and Equipmn ent 901 General 902 Dining Surfaces and Work Surfaces 902.1 General. Accessible dining surfaces and work surfaces shall comply with Section 902, EXCEPTION: Dining surfaces and work sur- faces primarily for children's use shall be per- mitted to comply with Section 902.4. 902.2 Clear Floor Space. Clear floor space com- plying with Section 305, positioned for a forward ap., proach, shall be provided. Knee and toe clearance complying with Section 306 shall be provided. Kly-A4 SIM 4' "M NOMS IN 34 inches (865 mm)i maximum in height above the floor. MONISM ;N1rr,rnY*)-,6)-rW- -:� A . —IF *11_S11 I ply with Section 902'.4. EXCEPTION: Dining surfaces and work surfaces used primarily by children, ages 5 and younger shall not be required to comply with Section 902.4 where a clear floor space complying with Section 305, positioned for a parallel approach, is provided. PaYrTMARNMINTOMM clearance complying with Section 341i6 shall «jrovided, EXCEPTION: Knee clearance 24 inches (610 mm) minimum above the floor shall be permitted. WIQIM411`111==�, , , 903 Benches 903.1 General. Accessible benches shall comply with Section 903. �Qli f �f,012CIear]Fl R r 903.3 Size. Benches shall have seats 42 inches (1065 mm) minimum in length, and 20 inches (510 mm) minimum and 24 inches (610 mm) maximum in depth. 903.4 Back Support. The bench shall provide for back support or shall be affixed to a wall. Back sup- port shall be 42 inches (1065: mm), minimum in length and shall extend from a point 2 inches (51 mm) maximum above the seat surface to a point 1 ,8 inches (455 mm) minimum above the seat surface. Back support shall be 21/2 inches (64 mm) maxi- mum from the rear edge of the seat measured hori- zontally. 903.5 Height. The top of the bench seat shall be 17 inches (430 mm) minimum and Ill) inches (485 mm) maximum above the floor, measured to the top of the seat. 903.6 Structural Strength. Allowable stresses shall not be exceeded for materials used where a vertical or horizontal force of 250 pounds (I 112 N) Is applied at any point on the seat, fastener mount- ing device, or supporting structure. 903.7 Wet Locations. Where provided in wet loca- tions the surface of the seat shall be slip resistant and shall not'adcumulate water. ­`904 Sales and Service Counters . .. .. ...... 904,1'-Gener,aii,Accessiblesales�,and-s,ori�vice count- ers shall comply with Section 904 as applicable. 9,04.2 Approach. All portions of counters required to be accessible shall be located adjacent to a walk- ing surface complying with Section 403. 904.3 Sales and Service, Counters. Sales and service counters shall comply with Section 904.3.1 or 904.3,2. The accessible portion of the countertop shall extend the same depth as the sales and ser- vice countertop. Chapter 9. Built -In Furnishings and Equipment ICC/ANSI A117.1-2003 N o_ 7 I M bench 00 N i l 42 min I� l �1065 L------- (a) Clear Floor Space and Size 21/2 max 64 20 — 24 510 — 610 U) M CO T � I r� o T W (b) Bench Back Support and Seat Height Fig. 903 Benches 904.4 Checkout Aisles. Checkout aisles shall comply with Section 904.4. 904.4.1 Aisle. Aisles shall comply with Section 403. 904.4.2 Counters. The checkout counter sur- face shall be 38 inches (985 mm) maximum in height above the floor. The top of the counter edge protection shall be 2 inches (51 mm) maxi- mum above the top of the counter surface on the aisle side of the checkout counter. 904 4.3 Check Writing Surfaces. Where pro- vided, check writing surfaces, shall comply with Section 902.3. 90.5 Food Service Lines. Counters in food ser- vice lines shall comply with Section 904.5. 904.5.1 Self -Service Shelves and Dispens- Ing Devices. Self-service shelves and dispens- ing devices for tableware, dishware„ condi- ments, food and beverages shall comply with Section 308. 904.5.2 Tray Slides. The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (855 mm), maximum above the floor.. 904..5 Security Glazing. Where counters or teller windows have security glazing to separate person- nel from the public, a method to facilitate voice com- munication shall be provided. Telephone handset. devices, if provided, shall comply with Section 704.3. 86 Chapter 8. Special Rooms and Spaces ICC/ANSI A117.1-2003 8*3.5 Coat Hooks and Shelves. Accessible coat hooks provided within the room shall accommodate a forward reach or side reach complying with Sec- tion 308. Where provided, a shelf shall be 40 inches (1015 mm) minimum and 48 inches (1220 mm) maximum above the floor. 804 Kitchens and Kitchenettes 804.1 General. Accessible kitchens and kitchen- ettes shall comply with Section 804. 804.2 Clearance. Where a pass -through kitchen is provided, clearances shall comply with Section 804.2.1. Where n a .U<shs; d kitchen is , -provided_ ,dle rancdshall comply with Section 804.2.2. EXCEPTION: Spaces that do not provide a cook - top or conventional range shall not be require ter "',,comply with Section 804.2. � 804.2.1 Pd -theb'U§h Kitchens. In pass - through kitchens where counters, appliances or cabinets are on two opposing sides, or where counters, appliances or cabinets are opposite a parallel wall, clearance between all opposing base cabinets, counter tops, appliances, or walls within kitchen work areas shall be 40 inch- IWO (a) es (1015 mm) minimum. Pass -through kitchens shall have two entries. 804.2.2 U-Shaped Areas. In kitchens enclosed on three contiguous sides, clearance between all opposing base cabinets, countertops, ap- pliances„ or walls within kitchen work areas shall be 60 inches (1525 mm) minimum. 804.3 Work Surface. Work surfaces shall comply with Section 902. EXCEPTION: Spaces that do not provide a cook - top or conventional range shall not be required to provide an accessible work surface. Sinks. Sinks shall comply with Section 606. 804.5 Storage. At least 50 percent of shelf space in cabinets shall comply with Section 905.. 804.6 Appliances. Where provided, kitchen ap- pliances shall comply with Section 804.6. 804.6.1 Clear Floor Space. A clear floor space complying with Section 305 shall be provided at each kitchen appliance. Clear floor spaces are permitted to overlap. Fig. 804.2.1 Pass -through Kitchen Clearance iul5 (b) 80 Chapter 3. Building Blocks /4 6.4 2 1/2. 1 13 2'L4., 6.4 ��II Fig. 303.3 Beveled Changes in Level 60 min 1525 u r a (a) Circular 60 min 1525 A N JEE rc LO E N OLO r 24 min 610 I I I 36 min 12 min 915 12 min 305 305 (b) T-shaped Fig. 304.3 Size of Turning Space ICC/ANSI A117.1-2003 304.3.2 T-Shaped Space. The turning space shall be a T-shaped space within a 60-inch (1525 mm) minimum square, with arms and base 36 inches (915 mm) minimum in width. Each arm of the T shall be clear of obstructions 12 inches (305 mm) minimum in each direction, and the base shall be clear of obstructions 24 inches (610 mm) minimum. The turning space shall be permitted to include knee and toe clear- __- complying with Section 306 only at the end o�either the base or one arm. 304A Door Swing. Unless otherwise specified, "doors shall be permitted to swing into turning spaces. 305 Clear Floor Space 305.1 General. A clear floor space shall comply with Section 305. 305.2 Floor Surfaces. Floor surfaces of a clear floor space shall have a slope not steeper than 1:48 and shall comply with Section 302. 305.3 Size. The clear floor space shall be 48 inches (1220 mm) minimum in length and 30 inches (760 mm) minimum in width. 48 min 1220 0 b j co o � a M _J Fig. 305.3 Size of Clear Floor Space 305.4 Knee and Toe Clearance. Unless otherwise specified, clear floor space shall be permitted to in- clude knee and toe clearance complying with Sec- tion 306. 305.5 Position. Unless otherwise specified, the clear floor space shall be positioned for either for- ward or parallel approach to an element. 305.6 Approach. One full, unobstructed side of the clear floor space shall adjoin or overlap an accessi- ble route or adjoin another clear floor space. 304.3.1 Circular Space. The turning space 305.7 Alcoves. If a clear floor space is in an alcove shall be a circular space with a 60-inch (1525 or otherwise confined on all or part of three sides, mm) minimum diameter. The turning space additional maneuvering clearances complying with shall be permitted to include knee and toe clear- Sections 305.7.1 and 305.7.2 shall be provided, as ance complying with Section 306. applicable. ICC/ANSI A117.1-2003 Chapter I Building Blocks 301 General 301.1 Scope. The provisions of Chapter 3 shall ap- ply where required by the scoping provisions adopted by the administrative authority or by Chap- ters 4 through 10. 302 Floor Surfaces 302.1 General. Floor surfaces shall be stable, firm, and slip resistant, and shall comply with Section 302. Changes in level in floor surfaces shall comply with Section 303. 302.2 Carpet. Carpet or carpet tile shall be securely attached and shall have a firm cushion, pad, or backing or no cushion or pad. Carpet or carpet tile shall have a level loop, textured loop, level cut pile, or level cut/uncut pile texture. The pile shall be 1/2 inch (13 mm) maximum in height. Exposed edges of carpet shall be fastened to the floor and shall have trim along the entire length of the exposed edge. Carpet edge trim shall comply with Section 303. 1/2 max 13 IAI Fig. 302.2 Carpet on Floor Surfaces 302.3 Openings. Openings in floor surfaces shall be of a size that does not permit the passage of a 1/2 inch (13 mm) diameter sphere, except as allowed in Sections 407.4.3, 408.4.3, 409.4.3, 410.4, and 805.10. Elongated openings shall be placed so that the long dimension is perpendicular to the dominant direction of travel. 303 Changes in Level 303.1 General. Changes in level in floor surfaces shall comply with Section 303. 303.2 Vertical. Changes in level of 1/4 inch (6.4 mm) maximum in height shall be permitted to be vertical. Chapter 3. Building Blocks predominant direction of travel MEMBER long dimension --A. perpendicular to direction of travel 1/2 max 13 Fig. 302.3 Openings in Floor Surfaces 1/4 max 6.4 �_� ......... _.�._. Fig. 303.2 Vertical Changes in Level 303.3 Beveled. Changes in level greater than 1/4 inch (6.4 mm) in height and not more than 1/2 inch (13 mm) maximum in height shall be beveled with a slope not steeper than 1:2. 303.4 Ramped. Changes in level greater than 1/2 inch (13 mm) in height shall be ramped and shall comply with Section 405 or 406. 304 Turning Space 304.1 General. A turning space shall comply with Section 304. 304.2 Floor Surface. Floor surfaces of a turning space shall have a slope not steeper than 1:48 and shall comply with Section 302. 304.3 Size. Turning spaces shall comply with Sec- tion 304.3.1 or 304.3.2. ICC/ANSI A117.1-2003 Chapter 9. Built -In Furnishings and Equipment Chapter 9, Built-in Furnishings and Equipment 901 General 901.1 Scope. Built-in furnishings and equipment re- quired to be accessible by the scoping provisions adopted by the administrative authority shall comply with the applicable provisions of Chapter 9. 902 Dining Surfaces and Work Surfaces 902.1 General. Accessible dining surfaces and work surfaces shall comply with Section 902. EXCEPTION: Dining surfaces and work sur- faces primarily for children's use shall be per- mitted to comply with Section 902.4. 902.2 Clear Floor Space. Clear floor space com- plying with Section 305, positioned for a forward ap- proach, shall be provided. Knee and toe clearance complying with Section 306 shall be provided. 902.3 Height. The tops of dining surfaces and work surfaces shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum in height above the floor. 902.4 Dining Surfaces and Work Surfaces for Children's Use. Accessible dining surfaces and work surfaces primarily for children's use shall com- ply with Section 902.4. EXCEPTION: Dining surfaces and work surfaces used primarily by children ages 5 and younger shall not be required to comply with Section 902.4 where a clear floor space complying with Section 305, positioned for a parallel approach, is provided. 902.4.1 Clear Floor Space. A clear floor space complying with Section 305, positioned for for- ward approach, shall be provided. Knee and toe clearance complying with Section 306 shall be provided. EXCEPTION: Knee clearance 24 inches (610 mm) minimum above the floor shall be permitted. 902.4.2 Height. The tops of tables and count- ers shall be 26 inches (660 mm) minimum and 30 inches (760 mm) maximum above the floor. 903 Benches 903.1 General. Accessible benches shall comply with Section 903. 903.2 Clear Floor Space. A clear floor space com- plying with Section 305, positioned for parallel ap- proach to an end of the bench seat, shall be pro- vided. 903.3 Size. Benches shall have seats 42 inches (1065 mm) minimum in length, and 20 inches (510 mm) minimum and 24 inches (610 mm) maximum in depth. 903.4 'Back ,Support. The bench shall provide for back support or shall be affixed to a wall. Back sup- port shall be 42 inches (1065 mm) minimum in length and shall extend from a point 2 Inches (51 mm) maximum, above the seat surface to a point 18 inches (455 mm) minimum above the ,seat surface.. Back support shall be 21/2 inches (64 mm) maxi- mum from the rear edge of the seat measured hori- zontally. 903.5 Height. The top of the bench seat shall be 17 inches (430 mm) minimum and 19 inches (485 mm) maximum above the floor, measured to the top of the seat. 903.6 Structural Strength. Allowable stresses shall not be exceeded for materials used where a vertical or horizontal force of 250 pounds (1112 N) is applied at any point on the seat, fastener mount- ing device, or supporting structure. 903.7 Wet Locations. Where provided in wet loca- tions the surface of the seat shall be slip resistant ark shall -no( ccumulate.,wate 04 Sales and Service Counters 9 14pnewlral. Accessible sales anct6rvice count- ers shall complJy'" Ith°'Sbc'fivn 904 as applicable. 904.2 Approach. All portions of counters required to be accessible shall be located adjacent to a walk- Ing surface complying with Section 403. 904.3 Sales and Service Counters. Sales and service counters shall comply with Section 904.3.1 or 904.3.2. The accessible portion of the countertop shall extend the same depth as the sales and ser- vice countertop. 85 Chapter 9. Built -In Furnishings and Equipment ICC/ANSI A117.1-2003 E N I i v o y l N f0 0 'I bench I I l N O Y I LO I yi l i l 42 min I l 1065 (a) Clear Floor Space and Size 21/2 max 0 20 — 24 510 — 610 LO (b) Bench Back Support and Seat Height Fig. 903 Benches 904.3.1 Parallel Approach. A portion of the counter surface 36 inches (915 mm) minimum in length and 36 inches (9115 mm) maximum in height above the floor shall be provided.. Where the counter surface is less than. 36 inches (915 mm) in length, the entire counter surface shall be 36 inches (915 mm) maximum in height above the floor. A clear floor space complying with Section 305, positioned for a parallel ap- proach adjacent to the accessible counter, shall be provided. 904.3.2 Forward Approach. A portion of the counter surface 30 inches (760 mm) minimum in length and 36 inches (915 mm) maxlr`nu,rn in height above the floor shall be provided. A clear floor space complying with Section 305, posi- tloned for a forward approach to the accessible counter, shall be provided. Knee and toe clear- ance complying with Section 306 shall be pro- vided under the accessible counter. 904.4 Checkout Aisles. Checkout aisles shall comply with Section 904.4. 904.4.1 Aisle. Aisles shall comply with Section 403. rn o r- v n o r rn 904.4.2 Counters. The checkout counter sur- face shall be 38 inches (965 mm) maximum in height above the floor. The top of the counter edge protection shall be 2 inches (51 mm) maxi- mum above the top of the counter surface on the aisle side of the checkout counter. 904.4.3 Check Writing Surfaces. Where pro- vided, check writing surfaces shall comply with Section 902.3. 904.5 Food Service Lines. Counters in food ser- vice lines shall comply with Section 904.5. 904.5.1 Self -Service Shelves and Dispens- ing Devices. Self-service shelves and dispens- ing devices for tableware, dishware, condi- ments,. food and beverages shall comply with Section 308. 904.5.2 Tray Slides. The tops of tray slides shall be 28 inches (710 mm) minimum and 34 inches (865 mm) maximum above the floor. 904.E Security Glazing. Where counters or teller windows have security glazing to separate person- nel from the public, a method to facilitate voice com- munication shall be provided. Telephone handset devices, if provided, shall comply with Section 704.3. 86 Development Services earre 250 Madison Street, Suite 3 Port Townsend WA 98368 Phone: 360-379-5095 Fax: 360-344-4619 was+ www.cityofpt.us Commercial Building Permit Application Project Adddreess& Zoning District„ Legal Descr° tion (or Tax #): (Pot &0 CY#(01 Addition: �'0 ' Block: Parcel # )° �,� 9967oo?S(oI Lot(s Descri JMeV (��NT" OF L ➢ Applications accepted by mail must include a check for initial plan review fee of $150 ➢ See the "Commercial Building Permit Application Checklist' for details on plan submittal requirements, Property Owner: Name: $ALI-WAS LTI) Contact/Repre n ative: PAV L� W(J. A , Name: V0 <Ankt'h w + : 00 � . _ Contractor- Nar te: 01 Address: City/St/Zip: Pho Email; State License #: City Business License #: I hereby certify that the information provided is correct, and that all activities associated with this permit will be Print Name: Office Use Only Per ift 01 #., Associated Permits: Lender Information: Lender information must be provided for projects over $5,000 in valuation per RCW 19.27.095. Name: Project Valuation: $ Construction Type: V "g Occupancy Rating:___ Building Information (square feet): 1"floor Restrooms: 2"d floor Deck(s):_ 3`d floor Storage: Basement: Is it finished? Yes No Other: New ❑ Addition ❑ Remodel/Repair 2111, Change of Use ❑ Total Lot Coverage (Building Footprint): Square feet: 4,000 % ( p p Impervious Surface: rdance with State Laws act on behalf of the owner L Townsend Municipal Code. Signature: g 0tNr"V116o Y rohro COMMERCIAL BUILDING PERMIT APPLICATION CHECKLIST This checklist is for new construction, additions, and remodels. The purpose is to show what you intend to build, where it will be located on the lot, and how it will be constructed. Commercial building permit application. Non -Residential Energy Code forms: 3:� Lighting * Mechanical * Envelope .11 Three (3) sets of plans with North arrow and scaled, no smaller than'/" = 1 foot: -1 Title Page/Cover Sheet: 1. Project identification 2. Project address, legal description, location map, tax parcel number(s) 3. All design professionals identified including addresses and phone numbers 4. Name, address, and phone number of person responsible for project coordination 5. Design criteria, including occupancy group, construction type, allowed floor area vs. proposed, occupant loads, height and number of stories, deferred submittals, etc. 6. Designate compliance with all applicable codes 11 A site plan showing: 1. Legal description and parcel number (or tax number), 2. Property lines and dimensions 3. Setbacks from all sides of the proposed structure to the property lines in accordance with a pinned boundary line survey 4. On -site parking and driveway with dimensions 5. Street names and any easements or vacations 6. Location and diameter of existing trees 7. Utility lines 8. If applicable, existing or proposed septic system location 9. Delineated critical areas boundaries and buffers Foundation plan: 1. Footings and foundation walls 2. Post and beam sizes and spans 3. Floor joist size and layout 4. Holdowns 5. Foundation venting Floor plan: 1. Room use and dimensions 2. Braced wall panel locations 3. Smoke detector locations 4. Attic access 5. Plumbing and mechanical fixtures 6. Occupancy separation between dwelling and garage (if applicable) 7. Window, skylight, and door locations, including escape windows and safety glazing ❑ Wall section: 1. Footing size, reinforcement, depth below grade 2. Foundation wall, height, width, reinforcement, anchor bolts, and washers 3. Floor joist size and spacing 4. Wall stud size and spacing 5. Header size and spans 6. Wall sheathing, weather resistant barrier, and siding material 7. Sheet rock and insulation 8. Rafters, ceiling joists, trusses, with blocking and positive connections 9. Ceiling height 10. Roof sheathing, roofing material, roof pitch, attic ventilation Exterior elevations (all four) with existing slope of the land in relation to all proposed structures D If architecturally designed, one set of plans must have an original signature If engineered, one set of plans must have one original signature :1 For new dwelling construction, Street & Utility or Minor Improvement application PSEPUGET SOUND Mr. Yarberry, DSD Director (via email) City of Port Townsend Development Services Department 250 Madison Street, Suite 3 Port Townsend, WA 98368 March 26, 2008 RE: HPC08-005 & BLD08-046 & SNP08-005 TI work at Waterman & Katz Building Mr. Yarberry, This letter is written in response to your letter to me dated March 25, 2008. Thank you for your letter and summation behind the City's reasoning to not approve our current plan to place the front door to our office on the south end of the building. PSE, therefore, intends to resubmit and revise the current building permit set of plans currently on file with your department. These revisions will clearly indicate that the existing entry at 181 Quincy Street will be our primary entrance for both employees and customers and one that will be shared with the condominium owners. We will also delete the ramp, stairs and door from this entrance as well. I would like to proceed with our interior work based on a limited scope and partial approval as you suggested. Other changes will include alterations to our original exterior sign design and a relocation of our drop box for customer payments. We will revise these as well for approval under the sign permit noted above if that is necessary. We will work with the building owner and others to integrate or separately provide appropriate exterior signage. Thank you for your timely response and consideration of our request. Larry.7. Hurwit, AIA Manager, Facility _ Services Corporate Facilities Dept. PH: 425. 462-3290 FAX: 425. 462-3519 CELL: 206.604-5114 EMAIL: Larry.Hurwitz@pse.com WEB: www.PSE.com Cc: Alex Little, Little I Little Construction (via email) John Watts, City Attorney (via email) Bill Craven (PSE, via email, forwarding to Peter Newell) John McDonagh (via email) r� City of Fort Townsend Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 ("360) 385-5095 FAX (360) 344-4619 March 25, 2008 Larry J. Hurwitz, AIA Puget Sound Energy Building 10885 NE 4th St., PSE-IOS Bellevue, WA 98004-5591 RE: HPC08-005 & BLD08-046 PSE planned tenant improvements Waterman & Katz Building, 181 Quincy St.. Dear Mr. Hurwitz, I'm writing to inform you of the City's position regarding PSE's planned tenant improvements at the Waterman & Katz Building. As currently proposed, the City is unable to approve the southern fagade access and associated improvements as shown in both the above applications. The reasons for this are two fold First, in addition to the building and Historic Preservation Committee (HPC) permits, installation of the planned improvements would require review and approval under the City's Shoreline Master Program (SMP). All development within 200 feet of shoreline jurisdiction requires SMP approval in one form or another. The proposed southern fagade improvements were not included in the original shoreline approval done for conversion of Waterman & Katz to a mixed -use condominium (City file # LUP05-097). Second, the current scope would not likely receive city approval even if a shoreline permit were applied for. This is due to ,largely to the type improvements that would be needed within the public Waterwalk easement lying immediately south of Waterman & Katz. As you know, since the first floor in the building is 14" — 17" above the surrounding ground outside, an ADA accessible ramp would be required for any southern facing doors. When other accessible entrances are available, the City's Shoreline Master Program and the Non -Motorized Transportation Plan (NMTP) would not look favorably upon Such encroachments into the Waterwalk. As you know, the existing Quincy Street entrance to the building is available for your proposed use as well as other commercial portions of the building. If you are willing to consider revisions to the submitted building permit (and where necessary the HPC application) that indicate the Quincy Street entrance will be used, partial approval of the current building permit could be granted for those internal areas that would not change regardless of the entrance used. This would allow you to proceed with a limited scope of work while the revision was prepared, process and issued by our department. If you would like to proceed in this fashion, please indicate that in writing to me. Likewise, if you have questions about the above issues, please contact me at 360-344-3041 or via e-mail at lyarbcffv q cit o��t.us. Sincerely, Leonard Yarberry DSD Director Cc Peter Newell, Ballenas Alex Little, Little & Little Construction John Watts, City Attorney City of Port Townsend, Development Services Department 250 Madison Street, Suite 3, Port Townsend, WA 98368 (360) 385-5095 FAX (360) 344-4619 March 25, 2008 Larry J. Hurwitz, AIA Puget Sound Energy Building 10885 NE 4th St., PSE-10S Bellevue, WA 98004-5591 RE: HPC08-005 & BLD08-046 PSE planned tenant improvements Waterman & Katz Building, 181 Quincy St. Dear Mr. Hurwitz, I'm writing to inform you of the City's position regarding PSE's planned tenant improvements at the Waterman & Katz Building. As currently proposed, the City is unable to approve the southern facade access and associated improvements as shown in both the above applications. The reasons for this are two fold First, in addition to the building and Historic Preservation Committee (HPC) permits, installation of the planned improvements would require review and approval under the City's Shoreline Master Program (SMP). All development within 200 feet of shoreline jurisdiction requires SMP approval in one form or another. The proposed southern facade improvements were not included in the original shoreline approval done for conversion of Waterman & Katz to a mixed -use condominium (City file # LUP05-097). Second, the current scope would not likely receive city approval even if a shoreline permit were applied for. This is due to largely to the type improvements that would be needed within the public Waterwalk easement lying immediately south of Waterman & Katz. As you know, since the first floor in the building is 14" — 17" above the surrounding ground outside, an ADA accessible ramp would be required for any southern facing doors. When other accessible entrances are available, the City's Shoreline Master Program and the Non -Motorized Transportation Plan (NMTP) would not look favorably upon such encroachments into the Waterwalk. As you know, the existing Quincy Street entrance to the building is available for your proposed use as well as other commercial portions of the building. If you are willing to consider revisions to the submitted building permit (and where necessary the HPC application) that indicate the Quincy Street entrance will be used, partial approval of the current building -permit could be granted for those internal areas that would not change regardless of the entrance used. This would allow you to proceed with a limited scope of work while the revision was prepared, process and issued by our department. If you would like to proceed in this fashion, please indicate that in writing to me. Likewise, if you have questions about the above issues, please contact me at 360-344-3041 or via e-mail at lyar err x i yo ilcAYarbert Leo DSD Director Cc Peter Newell, Ballenas Alex Little, Little & Little Construction John Watts, City Attorney 2 yjf YJraJ. J��S h Ai R-E 45 �, r ,m �-- Uv 6 e.,S Receipt Number 08.0398 � wn Receipt Date: 0411812008 Cashier: FRONTDESK Pay r/Payee Name. PUGET SOUND ENERGY' Original Fe a rim ount Fee Permit # Parcel Fee Description amount Paid Balance, BLD08-046 996700101 Plan Review Fee - Revision $50.00 $50.00 $0.00 Total: $50.00 Previous Payment History Receipt,# Receipt Date Fee Description Amount Pahl Permit 08-0335 04/02/2008 Building Permit Fee $237.25 BLD08-046 08-0335 04/02/2008 Plan Review Fee $154.21 BLD08-046 08-0335 04/02/2008 Record Retention Fee for Building Permit $10.00 BLD08-046 08-0335 04/02/2008 State Building Code Council Fee $4.50 BLD08-046 08-0335 04/02/2008 Technology Fee for Building Permit $5.00 BLD08-046 Payrn 0 nt Check Paym41'ht Method NNum leer Am ou!nt CHECK 26410 _ $ 50.00 Total $50.00 genpmrtrreceipts Page 1 of 1 RepeiptDate. 0410212008 Cashler., FRONTIDIESK Pa(ye IP N crinit , Parcel Fee Description BLD08-046 996700101 Plan Review Fee BLD08-046 996700101 Technology Fee for Building Permit BLD08-046 996700101 State Building Code Council Fee B�D08-046 996700101 Building Permit Fee BLD08-046 996700101 Record Retention Fee for Building P Receipt Number: 00 %al FOO Amount olunt: Pold Balance', $154.21 $154.21 $0.00 $5.00 $5.00 $0.00 $4.50 $4.50 $0.00 $237.25 $237.25 $0.00 $10.00 $10.00 $0.00 Total: $410.96 genprrttrreceipts Page 1 of 1 P Rn1�� Yf rv. irdiryxuslwmc �mdu'SSa n+m'a'.. ...•._..._ uW1&VWGNII�IIf�'iilamM'�rwevt'�3'n+ioWpWd'�PWPI�II�IW i�Kwne7Aa IUI'wiYiMil�ImM�VdiTIMIPII�II�h�'�WtlW�lluM! GYmVGYmM9 " �J� nnlN �'w iee�rvrv:�n .. ._.. u P � rr;✓rr v ibvu, P. * u�—�,,,.Y� � � O I cn o cz 4.4 o U w W cc cz .. a� cz +j W � � OPP- 4-4 o N o cncn E� qZ a) ° Cl) E-� cl Inspection Report Project �_.w.._..._.. Permit # S.E�- Date Inspector Inspection & Notes