Loading...
HomeMy WebLinkAboutBLD03-297Waterman & Katz Building I81 Quincy Street Sui[e 301 Port Townsend, WA 98368 (Phone) 379-3208 (Fax)365-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Call 385-2294 for Inspection Permit Number: BLDO3-297 Issued: 01/09/04 Parcel Number: 97$ 300 003 Job Address: 1044 Lawrence Street Zoning: CC=HI Type: V_N Occupancy: A_3 Total Occupant Load: N/C Nature of Work: Install Tvne I Kitchen Hood with Make-ua Air; Fire Suppression to be installed under Revision #1 Owner: Jav and Christine Payne dba Wild Cobo Contractor: Alaine Fire & Safety ALPINFS077RP (360)379-1030 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 MECHANICAL -see attached duct wrap NER Appliance/Exhaust Interlock Exhaust Outlet Clearance - 2' above roof,• Y other Type Ipuct Gage Duct Joints/Seams -continuous liquid-tight weld - Grease-Duct Supports - no penetration of duct walls Duct Slope -'/<: IZ Duct/Enclosure Separation - 3 "min.; 12" maz or per wrap specs Duct Enclosure/Shaft -duct wrap manufacturer's instructions skald be on-site at time of Inspection Cleanouts Air Velocity DucUCombustible Clearance -18 "; 3 "from non-combustibles or per duct wrap specs Hood Flashing -less than I2 "from ceiling or walls requires flashing with 22 gage steel Make-up Air - 5 feet separation from exhaust - Duct insulation R-3.3 Grease Filters Canopy Hood -Installed per manufacturer's instructions ~. Page 1 of 2 Building Permit #HLD03-297 FINAL Fire Department Approval Building Make-up Air Vent and Exhaust Terminatian shalt be patnted to match existing roof/building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nai-ing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. -Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11 3 8 5-2 2 94. A 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-STYE WITH THE APPROVED PLANS. • Page 2 of 2 Waterman & Katz Building 181 Quincy Street Suite 301 Por[ Townsend, WA 98368 (Phone) 379-3208 (Fax) 385-7675 CITY OF PORT TOWNSEND ~, • CONSTRUCTION PERMIT & INSPECTION RECORD THI5 CARD MUST BE POSTED AT CONSTRUCTION SITE Ca113S5-2294 for Inspection Permit Number: BI,D03-297R-2 Issued: 03/02/04 Parcel Number: 975 300 003 Job Address: 1044 Lawrence Street Zoning: C=III Type: V'N Occupancy: A_3 Total Occupant Load: N/C Nature of Work: Revision #2: drywall ceiline and inspect duCYitlg• Owner: Jav and Christine Payne dba Wild Coho Contractor: Owner GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 SEE ORIGINAL PERMIT FOR OTHER INSPECTIONS. RF.OTTIRED TNSPECTIONS APPROVED/DATE DRYWALL ~ Ceiling ' / ' ' ~ MECHANICAL Ducting Page 1 of 2 Building Permit /tBLD03.297 FINAL Fire Department Approval Building Make-up Air Dent and E.zhaust Termination shall be painted to match existing roof/building GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of-way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected, For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a non-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Departmeut within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal & approval prior to making changes in the field. Contact the Building Department @ 379-3208 prior to making changes to the approved plans. 10. POST THI5 PERMIT ON-SITE WITH THE APPROVED PLAN5. Page 2 of 2 • THIS CARD MUST BE POSTED AT CONSTRUCTION SITE CALL 385-2294 FOR INSPECTION Permit Number: Ri.T)0'i-297R-1 Issued: Q]/09/04 Job Addtess: 1044 Tawrence Street- Wild ('nhn Rectaurant Owner/Proprietor: ~ and (`hnct;nr Par Use of Building: Restaurant Nature of Work: install Fire Snpnressinn System for ('ommercial Kitchen Hood Contractor: Alnine Fire and Sag}v Rvsfama inc. Conh~actor State License Number: AT.PINFR0T7RP F~ratinn 11/19!04 REQUIRED INSPECTIONS • ^ UL 300 System orientation/installation in accordance with rnanufacturer's/[JL listing and City permit ^ Appliances properly covered with correct nozzle(s) (appliance manufacturer's listing) ^ Duct and plenum covered with correct nozzle(s) ^ Positioning of nozzles ^ Nozzle covers in place (where required) ^ Fusible links within rated temperature requirement ^ Hood/duct penetrations sealed with weldor UL listed device ^ Cylinder pressure gauge in proper range (if gauged) ^ Hydrostatic test date of cylinder current (CO2 cartridge exempt) ^ Inspect cylinder mount(s) ^ Check travel of cable(s) ^ Cable piping and conduit properly bracketed ^ Proper sepazation between fryer(s) and devices with surface flames ^ Proper surface to filters clearance ^ Exhaust fan in operating order ^ Filters in proper orientation ^ Fuel shut-off in "on" posifion for operation/test ^ -Fan warning sign on hood ^ Manual release and location proper ^ Personnel instructions in manual operation of system ^ Class K Fire extinguisher within 30 feet and tagged properly ^ 40-B:C Portable Fire Extinguisher available and tagged properly ^ Electrical panel properly labeled for shunt-trip function and manual reset, if applicable ^ Other: Inspector: Inspector: Date: Date: ^ Automatic Trip Test ^ Manual Trip Test ^ Fue]/Power disconnect for all hooded appliances/outlets (with manual reset) ^ Hood protection system monitored by premises automatic fire alarm system ^ Certification/service tag on system(s) Inspector: Inspector: Date: Date: Page 1 of 1