HomeMy WebLinkAboutBLD03-296_-.~
N - 7 ~ Waterman &, Katz Building
181 Quincy Street, Suite 301
Port Townsend, WA 98368
Phone: (360)379-3208 Fax: (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD03-296 Issued: 12/31/03 Parcel Number: 948307902
Job Address: 1029 14`" Street Zoning: R D Type: VV=N Occupancy: R-3/U-1
Total Occupant Load: NC Nature of Work: Remodel sinele-family residence with attached arose.
Owners: Jakari L.L.C. Contractor: Rick Nelson Consturction
GENERAL CONDITIONS APPLY
SEPARATE PERMITS REOUIIiED:
Electrical -Contact Labor & Industries @ 360-417-2702
• FOOTINGS -Reinforcement
Porch/Deck Piers
•
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrester @ clothes & dishwashers
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
Seismic Restraint -strap tank @ 1/3 points
Pressure relief valve drain to exterior; terminate
6" - 24" above ground
MECHANICAL
Whole House Fan @ Laundry Room
ICitchen/Bath/LaundryFons
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation {R-4) and terminus (located 3' from openings)
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 3
Y
Permit # BLD03-294
y RE UIRED INSPECTIONS APPROVED/DATE
FRAMING
Prescriptive & designed braced wallpanel sheathin~&
naiding must be inspected prior to cover
Walls
Ceilings
Posts, Beams & Headers
Roof
Blocking
Rafter Positive Connection
Roof Venting - eave and ridge vents
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake (Wall Ports) /
Doors U-Factor - .20 or better D
Q l
/
~
Air Seal `
`
Fire Blocking ~ /t `
Weather Resistive Barrier ~ v
INSULATION
Floor (R-30)
D~
`
Walls (R-21) ~~~''/iD
Ceiling (R30vault/R-38 attic)
V l _
/~
apor Barrier: paint for walls and ceiling , (P
Baffles
DRY WALL NAILING i
Walls ~a~`
/ O
Ceiling ~~ ~ ~ j
Garage house separation (~ f ~ ~/I '~"I 11 / ~ S
I(( ~ ~ .
FINAL
House Num
b
er-s - 5" minimum / • ,
Plumbin
(~
-_ n s
~~g,
( U
l
~
g 7H ~.
.~,Z.,~ l D~~~~' ! a
Mech
i
l
ti /
'
an
ca
ea
ng l ~r
Vapor Barrier Paint Certificate v
(~(
Insulation Certificate
Smoke Detectors
Final -Building
i
•
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 3
-~p
~',^ - ~ ~~ t Permit it BLD03-296
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reEistration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC} measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
• requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required Public Works anaroval must be received prior to
schedulin¢ the Buildin¢ Deuartment's final inspection.
7. Final Inspecfions are required prior to occupancy; A Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
•
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 3
-~