Permit Number: BLDO3-292 Issued: 12/30/03 Parcel Number: 989 713 504
Job Address: 1005 Lawrence Street Zoning: C_III Type: V_N Occupancy: F-I/M/B
Totat Occupant Load: No Chanee
Nature of Work: TI: Remove non-load bearing walls: construct new; raise floor to match studio
Owner: GWR Properties dba BADd HABIT Contractor: Little & Little Construction LITTLLCI57CS
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS RE UIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RF,OiTTRF,iI iNCPF.CTInNC
D PAI7l1VF71/~l A TF
DEMOLITION -see permit #MI503-049
Materials from construction shall be deposited in approved
areas off-site in accordance with all state and local laws
and ordinances.
MECHANICAL -exhaust 8c make-up air terminations
require HPC review and approval; mechanical wiU be
addressed separately as a deferred submittal; fire damper
will be required to be installed at existing exhaust
penetration through one-hour wall due to proximity to
property line (per Tom Aumock)
FRAMING '
_
__ __.
rWalls
;Positive Connections
Lever Hard""wa"re required on any new doors ± ' "
Thresholds -maximum %: "
Fireblocking ,_..
NTaaeuveYing Clearances @ doors {if new are installed)
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page I of 3
i?G(liTiDTi it 71VCDL•!'~T7l~A7c•
.~~~~.... .i.Ui ,..~.a.vi~v
DRYWALL
Walls -existing "rear" wall is one-hour construction due
to proximity to property tine; repair/replacement of
sheetrock shall be with 5!8" Type X
Ceiling Hi-YKV VL'l//Jl -1-L'~
,`
(,~ \J
(~ ~ 1
~` ~'
INSULATION
Fill exposed exterior wall cavities t
FINAL
Property address posted -min. 5"numbers of contrasting
color posted near the main entrance of the building and
visible from the street per City ordinance.
Electrical Sign-off (L & I)
Fire Department Sign-Off
Barrier Free Access
Thresholds
Door Cleazances
Lever Hardware
Final -Mechanical: per revision for deferred submittal
Final -Building
GENERAL CONDITIONS
I. Contractors working on this project are required to have a Labor & Industries contractor's reeistration
number and a City business license. Failure to provide proof of this documentation prior to work may
result in job shat down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior
to beginning construMion; call 385-2294. Measures shall include installation of silt fencing and graveled
construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils
exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils
shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete.
Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required
inspections.
5. Re-inspection is required after inspection report corrections are completed.
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 2 of 3
~'
Pumit #BLD03-292
6, The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required Public Works aauroval must be received prior to
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are done
by the Building Department within one year. Call for at least one inspection per year to keep your
building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the Building
Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
[]
Ca1148 hours before you dig for utility line locates
I-800-424-5555
Page 3 of 3
AOFQO0.TTpwHS~ •ITY OF PORT TOWNSE D PUBLIC WORKS &
u _ DEVELOPMENT SERVICES DEPARTMENT
y _ ' ~2. ~ `. 40
~pFWPSM~v INSPECTION R~E,POv~RT
PERMIT NUMBER: ~~, l.f/ L~" ~C~ ~ ~ _~ ~ /
Address ~ ~/~~~ ~C~r ~,~J~C~- S~~ ti `-'I
~~ ~ Contractor ~ ~ ~ ~ ~~ ~{~ r t `-e~JJ ~,~r~
Owner ~~'~ ~~'U~{'i ~~ - d jC~f~~ ~~i f`
Date of Inspection ~~ ~ ~ I C3~
Worksite or Cell Phone#
^ Erosion/Sedimentation
^ Setbacks/Footings/LIFER
~7 Foundation Walls
7 Slab Interior Footingllnsulation
^ Groundwork/Plumbing Test
^ Underfloor Framing
^ Shear Wall/Holdowns
^ Plumbing/Top Out J DrywalllFire Wall
v Gas Pipe/Pressure Test ^ Gas/Wood Appliance
Propane Tank/Line U Manufactured Home Set-up
U Mechanical ^ Public Works
^ Framing :] Other/Consultation
~] Insulation
:] Interior Shear/BWP Nail ~EINAL
If corrections required, re-inspection must be done prior to covering or concealing areas
of construction. Additional fees may be assessed for multiple re-inspections.
For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM.
NO OCCUPANCY UNTIL FINALIZED BA~Y BJ,1l6BJNG AND, IF APPLICABLE, PUBLIC WORKS.
^ VIOLATION ~3 APPROVAL U CORRECTION REQUIRED
^ APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SITE
n
U
Approved pls auC~ rmit ca must be on-site and available at time of inspection.
,a
Inspector '~ ~ ~ Date `<~