Permit Number: BLD03-2g7 Issued: 12/09/03 Parcel Number: 985 208 401
Job Address: 607 V Street Zoning: R;lI Type: V_N Occnpancy: R-3
Total Occupant Load: No Change Nature of Work: Build 208 sp. ft. deck, stairs and railines,
Owners: Earl & Bettvlou Burnett Contractor: Owner
GENERAL CONDITIONS APPLY -SEE LAST PAGE
INSPECTIONS
APPROVED/DATE
FOOTINGS
Setbacks
Deck Pier Footings
Reinforcement
FLOOR FRAMING/DECK
All wood members to be pressure treated or wood of natural ,
resistanceto decay ,.
Posts
Beam
Joists (2" x 8"@ 16" o.c J I
Hangers
Positive Connection
Post-to-Pier
Post-to-Beam
Treated Wood to Concrete
Lag Bolts @ ledger
Blocking
French Doors - .40 or better U-Factor
FINAL
House Numbers posted (minimum 5"}
Guardrails ~
Handrails ~
Stairs i
Landing/1" Threshold ~
~
Smoke Detectors throughout existing construction per 1997 -
~
UBC ~~.
Deck -Final ,
',
Ca1148 hours before you dig utiliTy line locates: 1-800-424-5555
Page 1 of 2
Pemut N BLD03.287
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TE5C) measures shall be installed on-site and
inspected prior to beginning constructian; cai1385-2294. Measures shall include installafion of
silt fencing and graveled construction entrance (see attached details). Adjacent rights-of-way
shall be kept free of dirt debris. Soils exposed during construction shall be temporarily
stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding,
plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is reauired. Public Works approval must be received
prior to scheduline the Buildine Department's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for a
non-residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections
are done by the Building Department within one year. Call for at least one inspection per year
to keep your building permit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the
Building Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig utility line locates: 1-800-424-5555
Page 2 of 2