Permit Number: BLDO3-284 Issued: 02/26/04 Parcel Number: 966 600 901
Job Address: 1622 21" Street Units A - D Zoning: RR=II Type: VV=N Occupancy: R-3
Total Occupant Load: 4/4/414 Nature of Work: Construct Fourplex.
Owners: Laurel Heights, LLC Contractor: Island Construction. Inc. - ISLANCI008R0
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RFnTTTRF>1 TNCPF.(~'TT(1NS
APPRnVED/DATF,
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS -per engineer design
Setbacks ~ '~
Footings i
Interior Footings _ ~
Forms
Reinforcement
LIFER ~
Porch/Deck Piers
GROUNDWORK PLUMBING
Pressure Test ~~ {
Pipe Joints Exposed
'~ : _
~ f~ ~
~e Bedding `~
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pemtit N BLD03-284
RE UIRED INSPECTIONS
APPROVED/DATE
FOUNDATION -per architectural design
Stem Wall
'
Forms _
- _
Reinforcement --
- -- ------- -
_
Anchor Bo is per engineer design
Holdowns -per engineer shear wall schedule
SLAB -per engineer design
Reinforcement - 6 X 6 W 1.4 X W 1.4 W WF
Perimeter Insulation
PLUMING:
Rough-In (D-V-T & Clean outs) J
Water Supply , !
Water Hammer Arrester @ clothes & dishwashers _
Hose Bibs (backflow protection required)
/~
Pipe Insulation (R-3) '"'
Pressure Reduction Valve if> 80 psi
~
~
Water Heater ~ _/_
~
-~ ~
R-10 under if electric
Seismic Restraint -strap tank @ 1/3 points
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL - _._._.._..
--
C~ 8~~~f.-~~
Whole House Fan @ Laundry Room
KitchenBath/Laundry Fans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
Ca1148 hours before you dig for utility line -ocates
1-800-424-5555
Page 2 of 4
PemiiC# BLD03-284
RFniTiRF,D iNSPF.CTIONS APPROVED/DATE
FRAMING _ _ _ ___ _.__.__-_-- _----
--~~ ~'l~-GAF
Prescriptive & designed braced wall panel sheathing &
nailing-must be inspected prior to cover L7'7
~~
Walls ~~~:
Shear Walls -per engineer design
Floors -Engineered TJI plan to be on site at inspection
Ceilings
Posts, Beams & Headers -per engineer design
Roof
Trusses -Engineered truss plan to 6e on-site inspection
Blocking
Rafrer/ Truss Positive Connection - Hl
Roof Ventirig - eave and ridge vents
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake (Window Ports)
Doors U-Factor - .20 or better
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R-30 )
Walls (R-21 )
Ceiling (R-30vault(R-38 attic )
Vapor Barrier: paint
Baffles
DRY WALL NAILING
Walls -party wall separation
Ceiling
Enclosed Usable Space under Stairs
FINAL
Public Works Sign-Off
House Numbers - 5" minimum
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
ADA -Barrier &ee design (Type C Units)
ADA -parking space & ramps
Final -Building
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Pertmt # BLDOJ-284
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
re8istration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
. 6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduline the Buildin¢ Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-SSSS
Page 4 of 4
City of Port Townsend
Development Services Department
Waterman-Katz Building
181 Quincy Street, Suite 301A, Port Townsend WA 98368
(360) 379-3208 FAX (360) 385-7675
CERTIFICATE OF OCCUPANCY
Permit Number: SLD03-284
G~pOR7 Tp~
ti~
V ~O
~~~w
Owner: Laurel Heights
Address: 1622 21st Street #A - D
Location: Port Townsend, WA 98368
Building/Use: Residential Fourplex
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
Suzanne Wassmer; Permit Technician
Date
LI