HomeMy WebLinkAboutBLD03-281
Waterman & Katz Building
181 Quincy Street, Suite 30l
Pott rownsend, WA 98366
Phone: (360)379-3208 Pax (360)385-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO3-281 Issued: 02/26/04 Parcel Number: 966 600 901
Job Address: 1674 21a` Street Units A - D Zoning: RR=H Type: VV=N Occupancy: R-3
Total Occupant Load: 3/3/3/3 Nature of Work: Building #13: Construct Fourulex.
Owners: Laurel Heights, LLC Contractor: Island Construction, Inc. - ISLANCI008R0
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
. RE UIRED INSPECTIONS
APPRnVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS -per engineer design
Setbacks
Footings `~
Interior Footings
Forms `
Reinforcement
UFER __
Porch/Deck Piers
GROUNDWORK PLUMBING
Pressure Test
Pipe Joints Exposed
Pipe Bedding
~, . _
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pertni[ p BLD03-281
•
RFnTTTRF,11 TNSPF.['.TTONS
APPROVED/DATE
FOUNDATION -per architectural design
Stem Wall
Forms
Reinforcement
Anchor Bolts - -per engineer design
Holdowns -per engineer shear wall schedule
SLAB -per engineer design
Reinforcement - 6 X 6 W 1.4 X W 1.4 W WF
Perimeter Insulation
PLUMBING:
Rough-In (D-V-T & Clean outs)
~'
Water Supply ~ /
Water Hammer Arrester @ clothes & dishwashers ~
.
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under if electric
Seismic Restraint- strap tank @ 1/3 points i
Pressure relief valve drain to exterior, terminate -
6" - 24" above ground
MECHANICAL
Whole House Fan @ Laundry Room
Kitchen/Bath/LaundryFans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings) ~ " "
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Pemtil # BLD03-281
REQUIRED INSPECTIONS APPROVED/DATE
L
FRAMING
Prescriptive & designed braced wall panel sheathing
nailing must be inspected prior to cover
Walls
Shear Walls -per engineer design
Floors -Engineered TJI plan to be on site at inspection
Ceilings
/
Posts, Beams & Headers -per engineer design /
Roof ~ j-.- _~ I
Trusses -Engineered truss plan to be on-site at inspection . ,
Blocking
Rafter/ Truss Positive Connection - Hl - ~
Roof Venting - eave and ridge vents -
Windows -escape
_Windows = sa€ety glazing
Windows Ufactor - .40 or better
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake (Window Ports)
Doors U-Factor - .20 or better
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION
Floor (R-30) ; -~"
~
Walls (R-21) ~- l % ~' ~/
~~
Ceiling (R-30vau1tB-38 attic) ~ `~ ``~~' ` ~
Vapor Barrier: paint --
Baffles
DRY WALL NAILING ~
%
Walls-party wall separation ~ _
~'~~
Ceiling
-,
~ '
Enclosed Usable Space under Stairs
FINAL -
Public Works Sign-Off
House Numbers - 5" minimum
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Final -Building
Ca114$ hours before you dig for utility line locates
I-800-424-5555
Page 3 of 4
Perrttit # BLD03-281
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass Snal inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required. Public Works aaaroval must be received prior to
scheduling the Building DeuartmenNs final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
M City of Port Townsend
Building & Community Development
Waterman & Katz Building
181 Quincy Street
Port Townsend, WA 98368
(360) 379-3208 Fax: (360) 385-7576
u
CERTIFICATE OF OCCUPANCY
BLD03-281
Owner: Laurel Heights, Building #13
Address: 1674 21st Street, Units A-D
Location: Port Townsend, WA 98368
Building (or portion): Fourplex
Use(s) permitted: R-3 (residence)
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
~`lrY~
Approved:
Permit Technician Date