HomeMy WebLinkAboutBLD03-280W akrman & Kak BWlding 181 Quincy Skeet, Suik 301 Pon Townseml, WA 98368 Phone; 360.379.3208 Faa 360.3657675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD Call 385-2294 for Inspection Permit Number: BLDO3-280 Issued: 12/03/03 Parcel Number: 955 900 075 Job Address: 2246 Highland Loou Zoning: RR=H Type: V_N Occupancy: RR=3 Total Occupant Load: 5 Nature of Work: Set New Manufactured Home with Factory Built Porch Owner: Dick Morris Contractor: New Century Enterurises - NEWCEEL004C9: WAINS 0846 ****Installer: See Attached Installer Tat:**** GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REpUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 RE UIRED INSPECTIONS APPROVED/DATE • TEMP EROSION & SEDIMENT CONTROL ~ See general condition #2 and attached details with Public Works Permit #MIP03-148 i Silt Fence as needed Drive Off Mat to prevent sediment from leaving the site i FOOTINGS/SLAB Setbacks Forms Reinforcement FLOOR FRAMING (prior to skirting) Anchors Support Piers -Load-stamped and installed per manufacturer's installation manual, clearance of 18"min. from lowest point of I-beam and the ground or footing for min. of 75% of area under home w/ 12"min. elsewhere unless installation manual specifies; otherwise area around home graded to provide runoff away from home Call 48 hours before you dig for utilit3~ line locates 1-800-424-5555 Page 1 of 3 Building Permit #BLD03-280 REOUIREI) INSPF('TTnN~ aprunvF.nmeTF PLUMBING: - -- - -- - B (, ~ y Water Supply-Main shut-o valve ort or ball valve (~, installed in water supply piping prior to connection to " home, min. % diameter, same as supply pipe ~ /l ~~s~ Hose Bibs (backflow protection required) ' ` Pipe Insulation -Outside & in crawl space Pressure Test-100 p.s.i. for IS minutes Pressure relief valve drain - to exterior of skirting, exhaust downward between 6"and 24"above ground Drainage Piping -sloped min.. %s' per foot MECHANICAL Ducts & Duct Insulation Dryer Exhaust -vented to outside. Extension into crawl space requires venting through skirting with no dips; follow dryer manufacturer's instructions; total combined length of ducting not to exceed 14' w/2-90° elbows FRAMING: Entry Steps/Landing VAPOR BARRIER 6 mil black poly ground cover (not required where area under home is concrete slab floor with a minimum thickness of 3-''/z inches) FINAL Public Works Sign-Off - Electrical (L & I} Sign-Off House Number -minimum 5"numbers Plumbing Mechanical Final -Building No holes or gaps greater than 1/s "allowed in skirting. Crawl space ventilation per installation manual @ 1/150 (19 required.); located close to corners, on at least two opposing sides for cross ventilation. Crawl space access must provide access to all areas under home; minimum 18"x 24'; covered with vinyl, pressure treated wood or metal ~1 ~- ~ ~j ~, ~ Ca1148 hours before you dig for utility line locates f-800-424-5555 Page 2 of 3 Building Permit #BLD03-280 GENERAL CONDITIONS 1, Contractors working on this project are required to have a work may resalt in job shut down while this is accomplished. prior to 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc, once construction is complete. Applicant is responsible for protection of adjacent properties, 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294; a minimum of twenty-four hours notice is required. Public Works approval most be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Cert~cate of Occupancy are required PRIOR to occupancy. 8. Al] building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH TBE APPROVED PLANS. Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 • Watemtan & Katz Building I87 Qoiocy Slceef, Suite 301 Port Townsend, W A 98368 Phone: (360)379-3208 Fax: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THI5 CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDO3-ZSOR-1 Issued: 5/20/04 Parcel Number: 955 900 075 Job Address: 2246 Highland Loop Zoning: RR=II Type: V_N Occupancy: UU=1 Total Occupant Load: N/C Nature of Work:Revision #1: Build garage attached to manufactured home Owner: Dick Morris Dealer: Golden Horaes of Poulsbo -Kelly Rohr Installer: Sam Miller - WAINS 0846 Owners:`~.~rd'urel I)~iahts;°LLC Contra~r: Island action, I - GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: • Electrical -Contact Labor & Industries ~ 360-417-2702 L & I Alteration Permit shall be obtained prior to any construction or inspections RF.(ITTTRF.n TNCPFC'TTnNS • APPRnVED/DATE TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site FOOTINGS Setbacks Footings Forms Reinforcement ~ UFER Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 1 of 3 Pemn[ p BLD03-280R-1 RE UIRED INSPECTIONS APPROVED/DATE • • FOUNDATION Stem Wall Forms Reinforcement Anchor Bolts Holdowns I FRAMING Prescriptive & designed braced wall panel sheathing & nailing must be inspected prior to cover Walls Ceilings Posts, Beams & Headers Roof Trusses -Engineered truss plan to be on-site at inspection Blocking Rafter/ Truss Positive Connection - Hl Roof Venting - eave and ridge vents Windows -safety glazing Windows Ufactor - .40 or better NFRC window sticker must be on windows & doors at inspection time Fire Blocking Weather Resistive Barrier DRY WALL NAILING Walls Ceiling 1-Hour Occupancy Separation FINAL Public Works Sign-Off House Numbers - 5" minimum Stairs, Decks and Landings Final -Building h . ~' ~ ".~ (I wT~ Call 48 hours before you dig for utility line locates i-800-424-5555 Page 2 of 3 Pemtil p BLD03-280R-1 • GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; ca11 3 8 5-2 294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works . requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval priOY to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 0[3 n V I.1 LJ °~pOP~1p"~s~ CITY OF PORT TOWNSEND PUBLIC WORKS ° DEVELOPMENT SERVICES DEPARTMENT 9~°Fw.sH`~"~ INSPECTION RE/PORT ~j n PERMIT NUMBER: ~ ~f/ ~ 3 - ~~ V `f~ !~7` ~2 Address Contractor Owner Date of Inspection Worksite or Cell Phone# ^ Erosion/Sedimentation ^ Setbacks/Footings/UFER ^ Foundation Walls ^ Slab Interior Footing/Insulation ^ Groundwork/Plumbing Test ^ Underfloor Framing ^ Plumbing/Top Out ^ Gas Pipe/Pressure Test ^ Propane Tank/tine ^ Mechanical ^ Framing ^ Insulation Z~.~- f(~/ ~~ k: ~~ U Drywall/Fire Wall ^ Gas/Wood Appliance ^ Manufactured Home Set-up ^ Public Works 0 Other/Consultation Shear Wall/Holdowns LI Interior Shear/BWP Nail FINAL ~~ ~ ~,,,~ -r If corrections required, re-inspection must be done prior to covering or concealing areas C.J ~~GIG~ of construction. Additional fees may be assessed for multiple re-inspections. .J ~`-- For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM. ~bdt W~ ,GGc/`/ NO OCCUPANCY UNTIL FINALIZED BY BUILDING AND, IF APPLICABLE, PUBLIC WOR ^ VIOLATION APPROVAL U CORRECTION REQUIRED APPROVED WITH CORRECTION ~ NEED APPROVED PLANS & PERMIT ON SITE Approved plans and permit card must be on-site and available at time of in ection. Inspector ~C,__ ___ _ Dat~ 7 22_~~ -' Waterman &Ka[z Building 181 Quincy S[reet Suite 301 Port Townsend, WA 98368 Phone (360) 3793208 Fax (360) 385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-280R-2 Issued: 06/21/04 Parcel Number: 955 900 075 Job Address: 2246 Highland Loop Zoning: R-II Type: VV=N Occupancy: UU=1 Total Occupant Load: No Change Nature of Work: Revision #2: Chanee garage stemwall foundation to monolithic slab Owner: Dick Morris Contractor; New Century Enterprises LLC - NEWCEEL004C9 Installer: Sam Miller, WAINS 0846 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: • Electrical -Contact Labor & Industries @ 360-417-2702 L&I Alteration Permit Note: see original permit BLD03-280 (manufactured home) and R-1 (attached garage) for other inspections. RF.nTiTRF>) TNSPF.(~'TTONS APPROVED/DATE MONOLITHIC SLAB FOUNDATION Setbacks Forms Reinforcement Anchor Bolts Alternate Braced Wall Panel Holdown Hardware LIFER FINA-I. "_ ~~- t~ee original permit ~~ ~~ ~ J~ ~ ~ ,'J ~~ ~' ;~ ~ I J , Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of Z Building Permit NBLD03-280R-2 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11 3 85-2 2 94. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Soils exposed during construction shall be temporarily stabilized with matching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after any corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294; a minimum of twenty-four hours notice is required. Public Works approval must be received prior to scheduling the Building Department's final inspection. 7. Final Inspections and Certificate of Occupancy are required PRIOR to occupancy. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspecfion per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-3208 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. • Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 2 :~4P~p"°"~sm CITY OF PORT TOWNSEND PUBLIC WORKS ° DEVELOPMENT SERVICES DEPARTMENT ,~ ' „ ~ INSPECTION REPORT ~ ~~~'""'`f``c~"'~~ ~'~ OF WPSH~~ {~ tom, yy~p PERMIT NUMBER: Address Contractor Owner Date of Inspection L-!J U V- G O V It ' ~-- l~~w Cwt ~ >~ Q / 7'7 ~ 2~ lay Worksite or Cell Phone# ^ Erosion/Sedimentation ^ Setbacks/Footings/LIFER ^ Foundation Walls nl~~n ~~ r~ z-Es -z~~~ ^ PlumbinglTop Out ^ DrywalUFire Wall ^ Gas Pipe/Pressure Test ^ Gas/Wood Appliance ^ Propane Tank/Line ^ Manufactured Home Set-up ^ Slab Interior Footing/Insulation ^ Mechanical ^ Public Works ^ Groundwork/Plumbing Test ^ Framing ^ O er/Consultation ^ Underfloor Framing ^ Insulation - 0 ~ ^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail FINAL If corrections required, re-inspection must be done prior to covering or concealing areas of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZED BY BUILDING AND, IF APPLICABLE, PUBLIC WORKS. ^ VIOLATION ^ APPROVAL CORRECTION REQUIRED APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SITE ~I ICC~ L.~M.LS `TY~ ~I.9S t A~t-~ _, Approved plans and permit card must be on-site and available at time of inspection. InspectorV__ _ _ _ Date ~ 26 ~~ _ °°p"°~ CITY OF PORT TOWNSEND PUBLIC WORKS w°Q ism DEVELOPMENT SERVICES DEPARTMENT '~°FWaS~,~ INSPECTION REPORT f~ PERMIT NUMBER: ~~ ~ ~ . ~ ~~ ' ` ~~ Address Contractor O r • e.(..> Cam ~ wne Date of Inspection ~ ~ ~ D 3~,© 2(,~~ =Z7~1 Worksite or Cell Phone# ^ Erosion/Sedimentation ^ Plumbing/Top Out ^ Drywall/Fire Wall ^ Setbacks/Footings/LIFER ^ Gas Pipe/Pressure Test ^ Gas/Wood Appliance ^ Foundation Walls ^ Propane Tank/Line ^ Manufactured Home Set-up ^ Slab Interior Footing/Insulation ^ Mechani ~a~l y~p~ ^ Public Works ^ GroundworklPlumbing Test ~Framing~~ -_ ~ J Other(Consultation ^ Underfloor Framing ^ Insulation ~ Shear WaIUHoldowns J Interior Shear/BWP Nail ^ FINAL If corrections required, re-inspection must be done prior to covering or concealing areas of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZED BY BUILDING AND, IF APPLICABLE, PUBLIC WORKS. :~ VIOLATION ^ APPROVAL ~3CORRECTION REQUIRED ^ APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SIrTE 1! /-~ : ~~ ~. ~- n i / A, t ~~ --- J,, . ~ tt A 1 .r."~ <.- " Approved pl ns and permit card must be on-site and available at time of inspect~Pn. it Sr -_. Date Inspector _ ~~ ~._~ - aoFpoHTTUy~,HsR, CITY OF PORT TOWNSEND PUBLIC WORKS BUILDING AND COMMUNITY DEVELOPMENT 9J = .A ! 10 ' FoFWASM~o INSPECTION REPORT D PERMIT NUMBER: ~ ~t~>`,3 l-~~~/~ ~ f`1- Z Address 22" + b r IL h j Contractor ~~~~J t~1~ry ~'~1-fin ~ ~ S~.S~ Owner tJ i lam- ~ Or ~i ~~ Date of Inspection 7 / 2~ py Worksite or Cell Phone# 7 Erosion/Sedimentation ~ Plumbing/Top Out ^ Drywall/Fire Wall 7 Setbacks/Footings/UFER~re-~=1 Gas Pipe/Pressure Test ^ Gas/Wood Appliance 7 Foundation Walls C~t~'Q' 7 Propane Tank/Line 7 Manufactured Home Set-up ~LSlab Interior Footing/Insulation 7 Mechanical 7 Public Works Q Groundwork/Plumbing Test ^ Framing J Other/Consultation ^ Underfloor Framing ^ Insulation ^ Shear Wall/Holdowns ^ Interior Shear/BWP Nail ^ FINAL If corrections required, re-inspection must be done prior to covering or concealing areas of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Me~ageLine at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZjD B BUILDING AND, IF APPLIC,At3LE, PUBLIC WORKS. ~_v1AL-ATIOAL __ ;!~ ~RPPROVAL ~ 'CORRECTION REQUIRED ,~ ~_~ . '~__- E? -~ .. ,I _ -/ ~ ~-- ~. ' '' ~ ~ ~~~~~; i~~ ~- / .i ~- ~, ,~,_ _~I` ,~ %c ; r Approved plans and permit card must be on-site and available at time of inspection. '_~' ~ Inspector ~ ~~~ _ _ Date _i~ - ~- `'~'`~ _ .- T ~ ~ /- ~- ~, - . - _ ~_