HomeMy WebLinkAboutBLD03-279Watemmn & Katz Building
181 Quincy Street, Suite 307
Port Townsend, WA 98368
Phone: (360)379-3208 Faz: (J60j785-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLD03-279 Issued: 11/26/03 Parcel Number: 968100 806
Job Address: 452 30th Street Zoning: R=III Type: VV=N
Nature of Work: Build 210 souare foot roof over second floor deck.
Owner: Andv Erickson
Contractor: Owner
385-4622
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor Br, Industries @ 360-417-2702
FRAMING/FINAL -Framing and final inspections may
Abe done at the same time if all elements of construction are
available for inspection
Post - 4 x 6 Treated Wood or wood with natural
resistance to decay
Beam-4x8
Ledger - 2 x 10
Rafters - 2 x 8 @ 24" o.c.
Positive Connections
Treated Wood
Roof
Skylights
House Numbers -check for 5"numbers
Smoke Detectors
Final -Building
•
r.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 2
Occupancy: RR=3
~^
f
/ '
i
Pemrit #BLDD3-279
GENERAL CONDITION
1. Contractors working on this project are required to have a Labor & Industries contractor's
registratign number and a City business license. Failure to provide proof of this documentation
prior to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and
inspected prior to beginning construction; call 385-2294. Measures shall include installation of
slit fencing and graveled construction entrance (see attached details). Adjacent rights-of--way
shall be kept free of dirt debris. Soils exposed during construction shall be temporarily
stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding,
plantings, sodding, etc, once construction is complete. Applicant is responsible for protection of
adjacent properties.
3. Alt elements of engineering including nailing, holdowns, sheathing, and alternate braced wall
panels (ABWP} require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection call 385-2294. A
minimum of twenty-four hours notice is required Public Works anaroval must be received
prior to scheduling the Building Denartment'sfinal inspection
7. Final Inspections are required prior to occupancy; a Certifwcate of Occupancy is required for a
non-residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections
are done by tbe. Building Department within one year. Call for at least one inspection per year
to keep your building germit active.
9. Revisions require submittal & approval prior to making changes in the field. Contact the
Building Department @ 379-3208 prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 2