Loading...
HomeMy WebLinkAboutBLD03-278.~ Waterman and Katz building 181 Quincy Stree6 Suite 301 Pon TowosenQ Wq 98368 Phove: (360)379-3208 Fax: (360)385-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDO3-278 Issued: 12/10/03 Pareel Number: 985-209-501 Job Address: 359 R Street Zoning: RR=II Type: VV=N Occupancy: U-115-2 Total Occupant Load: 2/i Nature of Work: Construct two-story building for garage/storage Owner: Keith and Jean Marzan Contractor: Campbell Construction - CAMPBC*111LR GENERAL CONDITIONS APPLY: See last a e SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 REQUIRED INSPF,(''Tif)N~ e rnun~nm ~ m~ TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site - /~ ~ `~ FOOTINGS -per engineered details Setbacks Footings Forms Reinforcement -per engineering Porch Footings - UFEi~ -----_ _.. FOUNDATION -per engineered detail; all elements of engineering require inspection prior to ~' cover ?_ Retaining Wall ? Stem Wall I ~ ~ Forms Reinforcement -per engineered detail Anchor Bolts & Washers -per engineering Post to Foundation Wall Positive Connection En ineered Holdowns Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 3 Building Permit #BLDp3-278 ' RE UIRED INSPECTIONS APPROVED/DATE SLAB- per engineering Reinforcement `~ ~~~„ _ / ~ "~C EXTERIOR SFIEATHINGper engineering Engineered shear walls Braced wall panel design ~ ~- ` ~ FLOOR FRAMING NOTE: Engineered TCI floor plan on-site and available to the Inspector at time of inspection Joists Blocking Positive Connections Treated Wood to Concrete Anchor Bolts & Washers FRAMING ~ Walls -framing per shear wall designations "'> ..~ ~ g. ~ ._~~ ~~ Engineered sh J Sh anel Blocking Trusses Attic venfing -eave Positive connections Window U-factor - 0.40 or better Door U-factor - 0.20 or better NFRC sticker must be on windows, doors & skylights at time of inspection Air Seal Fireblocking Weather Resistive Bartier INSULATION- not required Floor (R-30 ) Walls (R-2~ Ceiling (R-38 ) Baffles Vapor Barrier Paint DRYWALL NAILING Walls Ceiling Garage Sepazation Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 2 of 3 Building Permit #BLD03-278 FINAL House Numbers - 5" numbers Stairs, Decks & Landings Final - buildin GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is reauired. Public Works aauroval must be received urior to schedulin¢ the Buildine Department's final inspection 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 3 ;~~'°p"°"~smy CITY OF PORT TOWNSEND PUBLIC WORKS & DEVELOPMENT SERVICES DEPARTMENT n9 ~~? ~-. ~~F WPSM~G INSPECTION REPORT PERMIT NUMBER: ~~ l'c ~ ~ ~-~~` Address ~ S C1 ~ ,5~ Contractor Owner ~~'t ry_~ Date of Inspection ~ - ~ _ ~5 Worksite or Cell Phone# Erosion/Sedimentation ^ Setbacks/Footings/LIFER ^ Foundation Walls ^ Slab Interior Footing/Insulation ^ Groundwork/Plumbing Test ^ Underfloor Framing ^ Shear Wall/Holdowns . 3 ~S5 - ~ ~7.~23 Plumbing/Top Out ^ Drywall/Fire Wall ^ Gas Pipe/Pressure Test ^ Gas/Wood Appliance ^ Propane Tank/Line ^ Manufactured Home Set-up Mechanical ^'~aming Insulation ^ Interior Shear/BWP Nail Public Works ,~Qthe ~Consultatiori ~C.~CaC2~ - ~-tt7C~ _I ^ FINAL 1f corrections required, re-inspection must be done prior to covering or concealing areas • of construction. Additional fees may be assessed for multiple re-inspections. For Re-inspection, call Inspection Message Line at (360) 385-2294 prior to 8:00 AM. NO OCCUPANCY UNTIL FINALIZED BY$UILDING AND, IF APPLICABLE, PUBLIC WORKS._ -- "" ^ VIOLATION ~ APPROVAL ^ CORRECTION REQUIRED ^ APPROVED WITH CORRECTION ^ NEED APPROVED PLANS & PERMIT ON SITE Approved pla s ar~Cl permit card ~ st be on-site and available at time of inspection. __ Inspector ' }~----~~~~.f ~ Date ~ ~`~'~ ` '