CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO3-276 Issued: 02/26/04 Parcel Number; 966 600 901
Job Address: 1807 21st Street Units A - D Zoning: R_II Type: V_N Occupancy: R-3
Total Occupant Load: 4141414 Nature of Work: Building #5: Construct Fourplex.
Owners: Laurel Heights, LLC Contractor: Island Construction. Inc - ISLANCI008R0
GENERAL CONDITIONS APPLY -SEE LA5T PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries C 360-417-2702
RF,(1TTTRF,iI TNSPF(-TT(lNS
r
LJ
APPRnVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as nezded
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS -per engineer design
Setbacks ~ ` -- "~`
Footings __ -
Interiox Footings
Forms -
Reinforcement
- _
`-----
LIFER _ _ __ __
__
Porcl~IDeck Piers
GROUNDWORK PLUMBING
Pressure Test
',
Pipe Joints Exposed ~~
Pipe Bedding
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pertitit # BI.D03-276
RE UIRED INSPECTIONS
APPROVED~DATE
FOUNDATION -per architectural design
Stem Wall
Forms ~
Reinforcement +~
~ ~
Anchor Bolts - -per engineer design ~ ~
Holdowns -per engineer shear wall schedule~~
SLAB -per engineer design
Reinforcement - 6 X 6 W 1.4 X W 1.4 W WF
Perimeter Insulation
Rough-In (D-V-T & Clean outs)
Water Supply ~~ ~"2,,~~>L~ ~, J
/ ~-
Water Hammer Arrester @ clothes & dishwashers
Hose Bibs (backflow protection required) _ _ _
Pipe su a ion -
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under if electric
Seismic Restraint -strap tank @ 1!3 points
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
Whole House Fan @ Laundry Room
I{itchen/Bath/LaundryFans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
Pe~rtdf # BLD03-27fi
r
RE UIRED INSPECTIONS APPROVED(DATE
FRAMING
Prescriptive & desiened braced wall panel sheathing &
nailing must be infected prior to cover
Walls
Shear Walls -per engineer design
Floors -Engineered TJI plan to be on site at inspection
Ceilings
Posts, Beams & Headers -per engineer design
Roof
Trusses -Engineered truss plan to be on-site inspection
Blocking
Rafter/ Truss Positive Connection - Hl
Roof Venting - eave and ridge vents
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better
NFRC window sticker must be on windows &
doors at inspection time
Fresh Air Intake (Window Ports)
Doors U-Factor - .20 or better
Air Seal
Fire Blocking
Weather Resistive Barrier
SULATION
Floor (R-30 )
Walls (R-21-21 )
Ceiling (R-30vault/R-38 attic )
Vapor Barrier: paint
Baffles
DRY WALL NAILING
Walls -party wttll separation ;:
Ceiling / _ ~: -~ ,~
Enclosed Usable Space under Stairs
FINAL
Public Works Sign-Off
~' 7 ~l `? ~ 1' 'J
/ {~
House Numbers - 5" minimum C n j '~
l
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
ADA -Barrier &ee design (Type C Units)
A -parking space & ramps
final -Building
Cat148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
ENE i CnNniTION
Pemtit # HLD03-276
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. oace
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is required Public Works auaroval must be received urior to
scheduling the Building Department's final insuection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least ape inspection per year to keep
your building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
City of Port Townsend
Development Services Department
• Waterman-Katz Building
181 Quincy Street, Suite 301A, Port Townsend WA 98368
(360) 379-3208 FAX (360) 385-7675
O~QORT T~~
~ yiP
u ~z
~~
CERTIFICATE OF OCCUPANCY
Permit Number: BLD03-276
Owner: Laurel Heights
Address: 1807 21st Street #A - D
Location: Port Townsend, WA 98368
Building/LTse: Residential Fourplex
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 15.04); has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
Suzanne Wassmer, Permit Technician
Date
•