Loading...
HomeMy WebLinkAboutBLD03-276Y s CITY OF PORT TOWNSEND Waterman & Katz Building 181 Quincy Sheet Sui[e 301 Port Tovmsend, WA 99368 Phone: (360) 379-3208 Fax: (360)385-7675 CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLDO3-276 Issued: 02/26/04 Parcel Number; 966 600 901 Job Address: 1807 21st Street Units A - D Zoning: R_II Type: V_N Occupancy: R-3 Total Occupant Load: 4141414 Nature of Work: Building #5: Construct Fourplex. Owners: Laurel Heights, LLC Contractor: Island Construction. Inc - ISLANCI008R0 GENERAL CONDITIONS APPLY -SEE LA5T PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries C 360-417-2702 RF,(1TTTRF,iI TNSPF(-TT(lNS r LJ APPRnVED/DATE TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as nezded Drive Off Mat to restrict sediment from leaving the site FOOTINGS -per engineer design Setbacks ~ ` -- "~` Footings __ - Interiox Footings Forms - Reinforcement - _ `----- LIFER _ _ __ __ __ Porcl~IDeck Piers GROUNDWORK PLUMBING Pressure Test ', Pipe Joints Exposed ~~ Pipe Bedding Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 1 of 4 Pertitit # BI.D03-276 RE UIRED INSPECTIONS APPROVED~DATE FOUNDATION -per architectural design Stem Wall Forms ~ Reinforcement +~ ~ ~ Anchor Bolts - -per engineer design ~ ~ Holdowns -per engineer shear wall schedule~~ SLAB -per engineer design Reinforcement - 6 X 6 W 1.4 X W 1.4 W WF Perimeter Insulation Rough-In (D-V-T & Clean outs) Water Supply ~~ ~"2,,~~>L~ ~, J / ~- Water Hammer Arrester @ clothes & dishwashers Hose Bibs (backflow protection required) _ _ _ Pipe su a ion - Pressure Reduction Valve if> 80 psi Water Heater R-10 under if electric Seismic Restraint -strap tank @ 1!3 points Pressure relief valve drain to exterior, terminate 6" - 24" above ground MECHANICAL Whole House Fan @ Laundry Room I{itchen/Bath/LaundryFans Environmental Air Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Ca1148 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Pe~rtdf # BLD03-27fi r RE UIRED INSPECTIONS APPROVED(DATE FRAMING Prescriptive & desiened braced wall panel sheathing & nailing must be infected prior to cover Walls Shear Walls -per engineer design Floors -Engineered TJI plan to be on site at inspection Ceilings Posts, Beams & Headers -per engineer design Roof Trusses -Engineered truss plan to be on-site inspection Blocking Rafter/ Truss Positive Connection - Hl Roof Venting - eave and ridge vents Windows -escape Windows -safety glazing Windows Ufactor - .40 or better NFRC window sticker must be on windows & doors at inspection time Fresh Air Intake (Window Ports) Doors U-Factor - .20 or better Air Seal Fire Blocking Weather Resistive Barrier SULATION Floor (R-30 ) Walls (R-21-21 ) Ceiling (R-30vault/R-38 attic ) Vapor Barrier: paint Baffles DRY WALL NAILING Walls -party wttll separation ;: Ceiling / _ ~: -~ ,~ Enclosed Usable Space under Stairs FINAL Public Works Sign-Off ~' 7 ~l `? ~ 1' 'J / {~ House Numbers - 5" minimum C n j '~ l Plumbing Mechanical/Heating Vapor Barrier Paint Certificate Insulation Certificate Smoke Detectors ADA -Barrier &ee design (Type C Units) A -parking space & ramps final -Building Cat148 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 ENE i CnNniTION Pemtit # HLD03-276 1. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. oace construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection ca11385-2294. A minimum of twenty-four hours notice is required Public Works auaroval must be received urior to scheduling the Building Department's final insuection 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non- residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least ape inspection per year to keep your building permit active. 9. Revisions require submittal and approval rior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 of 4 City of Port Townsend Development Services Department • Waterman-Katz Building 181 Quincy Street, Suite 301A, Port Townsend WA 98368 (360) 379-3208 FAX (360) 385-7675 O~QORT T~~ ~ yiP u ~z ~~ CERTIFICATE OF OCCUPANCY Permit Number: BLD03-276 Owner: Laurel Heights Address: 1807 21st Street #A - D Location: Port Townsend, WA 98368 Building/LTse: Residential Fourplex The above-referenced building or portion complies with the applicable requirements of the Port Townsend Building Code (PTMC 15.04); has passed all required inspections and may be used and occupied in the use and manner indicated above. This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not be removed except by the Building Official. Suzanne Wassmer, Permit Technician Date •