HomeMy WebLinkAboutBLD03-275Wakrman & Ka(z Building
181 Quincy Stree4 Suite 30]
Port Townsend, WA 98368
Phone: (360)379-37A8 Fax: (360)381-7675
CITY OF PORT TOWNSEND
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Ca11385-2294 for Inspection
Permit Number: BLDO3-275 Issued: 02/26/04 Parcel Number: 966 600 901
Job Address: 1911 21a` Street Units A - D Zoning: R_H Type: VV=N Occupancy: R-3
u
Total Occupant Load: 4/4/4/4 Nature of Work: Building #7: Construct Fourulex.
Owners: Laurel Heights, LLC Contractor: Island Construction. Inc - ISLANCIOOSRO
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
REOUiRED ~NSPECTiONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS -per engineer design
Setbacks
~~
Footings ~ 4
Interior Footings ~
Forms ~.
Reinforcement - "
LIFER _ _.
_.__.
PorchTDeck Piers
GROUNDWORK PLUMBING
~
Pressure Test _ ~
'
Pipe Joints Exposed
Pi a Beddin
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pemrit # BLD03-275
i RE UIRED INSPECTIONS
r
LJ
APPROVED/DATE
FOUNDATION -per architectural design
Stem Wall
Forms
Reinforcement
Anchor Bolts - -per engineer design
Holdowns -per engineer shear wall schedule
SLAB -per engineer design
Reinforcement - 6 X 6 W 1.4 X W 1.4 W WF
Perimeter Insulation
PLUMBING:
Rough-In (D-V-T & Clean outs) /' y
Water Supply f
J f
Water Hammer Arrester @ clothes & dishwashers ---~~. ~ r
~
Hose Bibs (backflow protection required) ~' i~
j~
Pipe Insulation (R-3)
Pressure Reduction V aloe if > 80 psi
~
Water Heater `
~ '
R-10 under if electric
Seismic Restraint -strap tank @ 1/3 points ,
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
Whole House Fan @ Laundry Room
KitchenBath/LaundryFanc
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terminus (located 3' from openings)
Call 48 hours before you dig for utility Iine locates
I-800-424-5555
Page 2 of 4
Permit N BLD03-275
RE UIRED INSPECTIONS APPROVED/DATE
I
L~
FRAMING -- E~g 2-c'`'~ .,
Prescriptive & designed braced wall panel sheathing & 1
-: ~^ ~ ~ ~f -
nailing must be inspected prior to cover ._
{" ,~
-
Walls , :.
!
Shear Walls -per engineer design ___ _.~- -- -------- -"'
Flonr~ neereit7JI plan to e o~spection j
Ceilings
Posts, Beams & Headers -per engineer design
Roof ~
Trusses -Engineered truss plan to be on-site inspection
Blocking i
Rafter/ Truss Positive Connection - H 1
Roof Venting - eave and ridge vents i
Windows -escape
Windows -safety glazing
Windows Ufactor - .40 or better i
NFRC window sticker must be on windows &
doors at inspection time i
Fresh Air Intake (Window Ports)
Doors U-Factor - .20 or better
Air Seal
__-.,.___---_--- ~~ c~ .-!t) - ~~~
Fire Blocking __,.._____~_~_,^--.---____.__.__
Weather Resistive Barrier ~
INSULATION
Floor (R-30)
Walls (R-21)
Ceiling (R-30vault/R-38 attic)
Vapor Barrier: paint
Baffles
DRY WALL NAILING
Walls -party wall separation
Ceiling
Enclosed Usable Space under Stairs ~
FINAL 1_ ~: T° I
~
~
Public Works Sign-Off ,~'
~-
~ ~~' i
House Numbers - 5" minimum f _
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
ADA -Barrier free design (Type C Units)
ADA -parking space & ramps
Final - Buildin
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Pemtit#HLD03-275
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
re¢istration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected
prior to beginning construction; ca11 3 85-22 94. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, 6oldowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
. 6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twen -four hours notice is re uired. Public Works a roval must be received rior to
scheduline the Buildine Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
City of Port Townsend
• Development Services Department
Waterman-Katz Building
181 Quincy Sweet, Suite 301A, Port Townsend WA 98368
(360) 379-3208 FAX (36D) 385-7675
CERTIFICATE OF OCCUPANCY
Permit Number: BLD03-275
Owner: Laurel Heights
Address: 191121st Street #A - D
Location: Port Townsend, WA 98368
Building/Use: Residential Fourplex
~ Qoer rory
,~ ~.
h ~
O m0
~~~w
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use. and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
iL(1 Gv~~,ti-Pi
Suzanne Wassmer, Permit Technician
Date