Loading...
HomeMy WebLinkAboutBLD03-273 \\'acemen ffi Kalz Building 181 Quincy Sheet, Suite 30I Pon Townsend, WA 98368 Phone: (360) 379-37A6 Pax: (360) 38>-7675 CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-273 Issued: 02/26/04 Parcel Number: 966 600 901 Job Address: 192 0 21st Street Units A - D Zoning: RR_II Type: V_N Occupancy: R-3 Total Occupant Load: 3/3/3!3 Nature of Work: Building #10: Construct Fourpiex. Owners: Laurel Heights, LLC Contractor: Island Construction, Inc. - ISLANCI008R0 GENERAL CONDITIONS APPLY -SEE LAST PAGE SEPARATE PERMITS REQUIRED: Electrical -Contact Labor & Industries @ 360-417-2702 RE UIRED INSPECTIONS APPR(~VF.n/PATE TEMP EROSION & SEDIMENT CONTROL See General Condition No. Z Silt Fence as needed Drive Off Mat to restrict sediment from leaving the site li FOOTINGS -per engineer design Setbacks Footings Interior Footings Forms ,~, Reinforcement '~ UFER _ __ - _ _ _ _ _ I'orcIi/Deck Piers GROUNDWORK PLUMBING ' Pressure Test ~~ Pipe Joints Exposed ~ ~ Pipe Bedding ~' Ca1148 hours before you dig for utility line locates I-800-424-5555 Page 1 of 4 Penmt # HLD03-277 RE UIRED INSPECTIONS APPROVED/DATE FOUNDATION -per architectural design __ Stem Wall _, r ~ 1 Forms ~ ~ / ' ----_ .. _ Reinforcement , _ _ . _ _-_ __._ .__ _ - Anchor Bolts - -per engineer design Holdowns -per engineer shear wall schedule SLAB -per engineer design Reinforcement - 6 X 6 W 1.4 X W 1.4 W WF Perimeter Insulation PLUMBING: Rough-In {D-V-T & Clean outs) Water Supply Water Hammer Arrester @ clothes & dishwashers Hose Bibs (backflow protection required) i Pipe Insulation (R-3) Pressure Reduction Valve if> 80 psi ~ Water Heater R-10 under if electric Seismic Restraint -strap tank @ 1/3 points i Pressure relief valve drain to exterior, terminate 6" - 24" above ground MECHANICAL ~' ~ Whole House Fan @ Laundry Room ~ ~ ~ - ! Kitchen/Bath/LaundryFanc Environmental Air Exhaust ducting (w/ backdraft dampers), ~ insulation (R-4) and terminus (located 3' from openings) i Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 2 of 4 Pe*mit # BLD03-273 REOiTiRF.D INSPECTIONS APPROVED/DATE -- - FRAMING _...... _ - _ _ _ ..------ -- _--__ / - I'~ 0~ Prescriptive & destened braced wall panel sheathing & ~ ~~ nailing must be inspected prior to cover Walls ~ / ~ , r) , G~ ,c Shear Walls -per engineer design --- Floors -Engineered TJI plan to be on site at inspection Ceilings Posts, Beams & Headers -per engineer design Roof Trusses -Engineered truss plan to be on-site at inspection Blocking Rafter/ Truss Positive Connection - Hl Roof Venting - eave and ridge vents Windows -escape Windows -safety glazing Windows Ufactor - .40 or better NFRC window sticker must be on windows & doors at inspection time Fresh Air Intake (Window Ports) Doors U-Factor - .20 or better Air Seal Fire Blocking Weather Resistive Bamer INSULATION Floor (R-30 ) Walls (R-21) Ceiling (R-30vault/R-38 attic ) Vapor Barrier: paint Baffles DRY WALL NAILING Walls -party wall separation Ceiling Enclosed Usable Space under Stairs FINAL ~~ ~~ ~ ~ ~ Public Works Sign-Off % i' ~`~~ > ) ~ = House Numbers - 5" minimum ~ ~ -~ `~ Plumbing ~' - Mechanical/Heating Vapor Barrier Paint Certificate Insulation Certificate Smoke Detectors Final -Building Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 3 of 4 Pemnt H BLD03-273 ' GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. • 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received prior to schedulin¢ the Buildin¢ Department's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon- residentialproject. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require submittal and approval prior to making changes in the field. Contact the Building Department (379-3208) prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. Call 48 hours before you dig for utility line locates 1-800-424-5555 Page 4 ot4 City of Port Townsend • Development Services Department Waterman-Katz Building 181 Quincy Street, Suite 301A, Port Townsend WA 98368 (360) 379-3208 FAX (360) 385-7675 oFQOnr rok ,~+ 'ta ~o ~~` ¢w CERTIFICATE OF OCCUPANCY Permit Number: BLD03-273 Owner: Laurel Heights Address: 1920 21st Street #A - D Location: Port Townsend, WA 98368 Building/LJse: Residential Fourplex The above-referenced building or portion complies with the applicable requirements of the Port • Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used and occupied in the use and manner indicated above. This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not be removed except by the Building Official. Approved: ~~~ti'I'~"'~'~- l•~'~~J ~- Mazch 18.2005 Suzanne Wassmer. Permit Technician Date •