Permit Number: BLD~3-27I Issued: 02/26/04 Parcel Number: 966 600 901
Job Address: 1603 21st Street Units A-D Zoning: RR=H Type: V_N Occupancy: R-3
Total Occupant Load: 3/3/3/3 Nature of Work: Buildine #3: Construct Fournlex.
Owners: Laurel Hei¢hts, LLC Contractor: Island Construction, Inc - ISLANCI008R0
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
APPROVED/DATE
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS -per engineer design
'
Setbacks ~
Footings
Interior Footings i
Forms
Reinforcement -
UFER
Porch/Deck Piers
GROUNDWORK PLUMBING
Pressure Test /~
`
Pipe Joints Exposed ~ /
Pipe Bedding ` ~ ~~
Ca114$ hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
Pemm # BLD03-271
RE UIRED INSPECTIONS
APPROVED/DATE
FOUNDATION -per architectural design
Stem Wall
Forms
Reinforcement
Anchor Bolts --per engineer design
Holdowns -per engineer shear wall schedule
SLAB -per engineer design
Reinforcement - 6 X 6 W 1.4 X W 1.4 W WF
Perimeter Insulation
PLUMBING: -
_____
r r
Rough-In (D-V-T & Clean outs) ' ,
~~
~a1er ~u~ly
"
rs
'Water Hammer Arresfer @,g"~shwashe
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under if electric
Seismic Restraint- strap tank @ 1/3 points
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL - _ ~ ~ ~ _. s _ ~> y
Whole House Fan @ Laundry Room
Kitchen/Bath/LaundryFans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and tenninus (located 3' from openings)
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
u
Permit # BLD03-291
RF,nTiTRF.iI TNSPFC"TiON4 APPROVED/DATE
FRAMING _
_ E,
.
Prescriptive & designed braced wall panel sheathing & ,
t:
? H
~
_
'
natlin~must be inspected prior to cover
Walls
Shear Walls -per engineer design
Floors -Engineered TJI plan to be on site at inspection
Ceilings
Posts, Beams & Headers -per engineer design
Roof
Trusses -Engineered truss plan to be on-site at inspection
Blocking
';
Rafter/ Truss Positive Connection - Hl
Roof Venting - eave and ridge vents
~~ ~ ,
Windows -escape J
Windows -safety glazing `
/
Windows Ufactor - .40 or better ~ ~ ~ .
NFRC window sticker must be on windows &
doors at inspection time %'
Fresh Air Intake (Window Ports) ~ `
Doors U-Factor - .20 or better
Air Seal
Fire Blocking
Weather Resistive Barrier
INSULATION ,
Floor (R-30 )
~
~
Walls (R-21) ~ -
~-!
Ceiling (R-30vault/R-38 attic) a° ~;
Vapor Barrier: paint _
Baffles
_
DRY WALL NAILING TM"`
__._
~~
~Ji~,'~ PuJ ~ ~ '7,.~~1~c~~`
Walls -party wall separation
Ceiling ~ ~ ~'' ~ ' "0`'~
Enclosed Usable Space under Stairs
FINAL
Public Works Sign-Off -
~: r
J' ~ .~~ - ~~ ;J ~/.~~'
House Numbers - 5" minimum
~ r
~ ~ ~ `
~
Plumbing . -
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Final -Building
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
Pertni[ # BLD03-271
GENERAL CONDITIONS
1. Contractors working on this project are required to have a Labor & Industries contractor's
registration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all de£ciencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
• 6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11 3 85-2 294. A
minimum of twenty-four hours notice is required. Public Works approval must be received prior to
scheduling the Building Department's final inspection.
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required fora non-
residential project.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval prior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
City of Port Townsend
Development Services Department
Waterman-Katz Building
181 Quincy Street, Suite 301A, Port Townsend WA 98368
(360)379-3208 FAX (360)385-7675
o~QOarTO~
~ yin
u ~z
~~¢
CERTIFICATE OF OCCUPANCY
Permit Number: BLD03-271
Owner: Laurel Heights
Address: 1603 21st Street #A - D
Location: Port Townsend, WA 98368
Building/Llse: Residential Fourplex
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
Approved:u /~'~'R'r"`~- w~'t'~n^P~- March 18 2005
Suzanne Wassmer, Permit Technician Date
•