HomeMy WebLinkAboutBLD03-265
-1
. ,
CITY OF PORT TOWNSEND
Waterman & Katz Hwlding
161 Quincy Stree; Suite 301
Port Townsend, WA 98368
Phone: (360)379-3208 Fax: (360)385-7fi75
CONSTRUCTION PERMIT & INSPECTION RECORD
THIS CARD MUST BE POSTED AT CONSTRUCTION SITE
Call 385-2294 for Inspection
Permit Number: BLDO3-265 Issued: 02/26/04 Parcel Number: 966 600 901
Job Address: 2002 McClellan #A & B Zoning: RR=II Type: VV=N Occupancy: R-3
Total Occupant Load: 3/3 Nature of Work: Building #2: Construct Duulex.
Owners: Laurel Heiehts, LLC Contractor: Island Construction, Inc. - ISLANCI008R0
GENERAL CONDITIONS APPLY -SEE LAST PAGE
SEPARATE PERMITS REQUIRED:
Electrical -Contact Labor & Industries @ 360-417-2702
RE UIRED INSPECTIONS
A PPR (IVF.i1/n A TTi',
TEMP EROSION & SEDIMENT CONTROL
See General Condition No. 2
Silt Fence as needed
Drive Off Mat to restrict sediment from leaving
the site
FOOTINGS -per engineer design
Setbacks
_-__. ---
Footings
~
Interior Footings ,
~'` ~ 1C. tf + (~ ; ~~~~~ ~-
Forms ~ `
Reinforcement ______ --
UFER
Porch/Deck Piers ~ ';_.
_-_
' __.
'
_
WORK PLU11~SIN-~= ~__ __ . _ _._.
ressure Test - ---~-
Pipe Joints Exposed e ~ ' r~ ~J~, ~ ~ ~~
Pipe Bedding ~%- -~ } ~'\, ;
~'
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 1 of 4
RE UIRED INSPECTIONS
APPROVED/DATE
t
Pamtit # BLD03-265 ~-
FOUNDATION -per architectural design
Stem Wall
Forms ~~' _ c,,
~ ~ ~'
`~ ~
Reinforcement ~ ;
_.,..__._._
_ ~3
z,
_
chor Bo s - -per engineer esagn
Holdowns -per engineer shear wall schedule
SLAB -per engineer design
Reinforcement - 6 X 6 W 1.4 X W 1.4 W WF
Perimeter Insulation
PLUMBING:
Rough-In (D-V-T & Clean outs)
Water Supply
Water Hammer Arrester @ clothes & dishwashers
Hose Bibs (backflow protection required)
Pipe Insulation (R-3)
Pressure Reduction Valve if> 80 psi
Water Heater
R-10 under if electric
Seismic Restraint -strap tank @ 1/3 points
Pressure relief valve drain to exterior, terminate
6" - 24" above ground
MECHANICAL
Whole House Fan @ Laundry Room
KitchenBath/Laundry Fans
Environmental Air Exhaust ducting (w/ backdraft dampers),
insulation (R-4) and terrninus (located 3' from openings)
Call 48 hours before you dig for utility line locates
1-800-424-5555
Page 2 of 4
~,
REQUIRED INSPECTIONS
Permit k BLD03-265
A PPR OVF.TIlII A TR.
FRAMING
Prescriptive & desitmed braced wall panel sheathing &
nailing must be inspected prior to cover `
Walls
Shear Walls -per engineer design
Floors -Engineered TJI plan to be on site at inspection
Ceilings -
Posts, Beams & Headers -per engineer design
Roof
Rafters -per engineer design
Trusses -Engineered truss plan to be on-site at inspection
Blocking
Rafter/ Truss Positive Connection - Hl
Roof Venting - eave and ridge vents
Windows -escape
Windows -safety glazing '
Windows Ufactor - ,40 or better -
NFRCwindow sticker must be on windows &
doors at inspection time
Fresh Air Intake (Window Ports)
Doors U-Factor - .20 or better
Air Seal
Fire Blocking
Weather Resistive Barrier
f ~'
s
.t . _ 1, ,, , f- _
,, ~, ~-
INSULATION
Floor (R-30 )
Walls (R-21)
Ceiling (R-30vaulUR-38 attic )
Vapor Barrier: paint
Baffles
,f `'D'i'
DRY WALL NAILING J ~ i
~
'
_
Walls-party wall separation -- ~wrJr~
rr_`~:`="'~?.
~
Ceiling ~ =--` "
Enclosed Usable Space under Stairs
FINAL
Public Works Sign-Off ~ ~ , - ~~~
House Numbers - 5" minimum
Plumbing
Mechanical/Heating
Vapor Barrier Paint Certificate
Insulation Certificate
Smoke Detectors
Final -Building
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 3 of 4
GENERAL~ONDITIONS
•
1. Contractors working on this project are required to have a Labor & Industries contractor's
reeistration number and a City business license. Failure to provide proof of this documentation prior
to work may result in job shut down while this is accomplished.
2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected
prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and
graveled construction entrance (see attached details). Adjacent rights-of--way shall bekept-free of dirt
debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic
sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once
construction is complete. Applicant is responsible for protection of adjacent properties.
3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels
(ABWP) require inspection prior to cover.
4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by
required inspections.
5. Re-inspection is required after inspection report corrections are completed.
6. The Building Department is unable to pass final inspection on your project until Public Works
requirements have been completed and inspected. For Public Works inspection ca11385-2294. A
minimum of twenty-four hours notice is reauired Public Works auaroval must be received prior to
scheduling the Building Denartment's final inspection
7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-
residentialproject.
8. All building permits expire if no progress has been made within six months, or if no inspections are
done by the Building Department within one year. Call for at least one inspection per year to keep
your building permit active.
9. Revisions require submittal and approval rior to making changes in the field. Contact the Building
Department (379-3208) prior to making changes to the approved plans.
10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS.
Petrmt#B],pD3-265 '«
Ca1148 hours before you dig for utility line locates
1-800-424-5555
Page 4 of 4
t
t
City of Port Townsend
Building & Community Development
Waterman & Katz Building
181 Quincy Street
Port Townsend, WA 98368
(360)379-3208 Fax: (360)385-7576
CERTIFICATE OF OCCUPANCY
BLD03-265
Owner:
Address:
Location:
Building (or portion):
Use(s) permitted:
•
Laurel Heights
2002 McClellan Street
Port Townsend, WA 98368
Duplex
R-3 (residences)
The above-referenced building or portion complies with the applicable requirements of the Port
Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official. '
C~~~~
Approved: Suzanne Wassmer September 1, 2004
Permit Technician Date
•
Ago, poet io~tiiP
' City of Port Townsend
Development Services Department ° -, ';
::_
• .Waterman-Katz Building `~.y,~~ s -
181 Quincy Street, Suite 301A, Port Townsend WA 98368 ¢w
(360) 379-3208 FAX (360) 385-7675
CERTIFICATE OF OCCUPANCY
Permit Number: BLD03-265
Owner: Laurel Heights
Address: 2002 McClellan #A and B
Location: Port Townsend, WA 98368
BuildinglLJse: Residential Duplex
The above-referenced building or portion complies with the applicable requirements of the Port
• Townsend Building Code (PTMC 16.04), has passed all required inspections and may be used
and occupied in the use and manner indicated above.
This certificate of occupancy shall be posted in a conspicuous place on the premises and shall not
be removed except by the Building Official.
Permit Technician