Loading...
HomeMy WebLinkAboutBLD03-259 i CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD. THIS CARD MUST BE POSTED AT CONSTRUCTION SITE Celt 385-2294 for Inspection Permit Number: BLDO3-259 Issued: 12/01/03 Parcel Number: 961-200-207 Job Address: 2303 Hendricks Street Zoning: RR=II Type: VV=N Occupancy: R-3/U-1 Total Occupant Load: 7/2 Nature of Work: Repair/rebuild wart of house due to fire Owner: Aumock Family Trust Contractor: Little & Little Construction - LITTLLC157C5 GENERAL CONDITIONS APPLY: See last pace SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept, of Labor & Industries 360-417-2702 RF.OTITRF.D TN~PF,f'TTnNC APPRf1VF.il/IIATF. EXTERIOR SHEATHING NOTE: Do not cover prior to iaspection Brace Wall Panel Design - (if applicable) See Correction Notice in File PLUMBING See Correction Notice in File Rough-In (D-V-T & Clean outs) Water Supply Water Hammer Arrestors- need to be accessible Pipe Insulation (R-3) Water Heater R-10 under if electric Seismic Restraint - 2 places Pressure Relief Valve drain to exterior, terminate 6" -24" above ground MECHANICAL See Correction Notice in File Source Specific Exhaust Fans @ bathrooms (SOcfrn) and kitchen (100 cfin) Environrnental Aif Exhaust ducting (w/ backdraft dampers), insulation (R-4) and terminus (located 3' from openings) Whole house fan -Laundry room Building Permit tlBLD03-259 GENERAL CONDITIONS 1. Contractors working on this project are required to have a Labor & Industries ~u~ --- contractor s rest§tration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shalt be kept free of dirt debris. Soils exposed during construcfion shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected, For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works approval must be received arior to scheduline the Buildine DepartmenPs final insnection 7. Final Inspections are required prior to occupancy; ACertificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval rior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. N • ~' r, CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD THIS CARD MUST BE POSTED AT CONSTRUCTION SITE _ Call°385-2294 for Inspeetioa- Permit Number: BLDO3-259R-1 Issued: 12/01/03 Parcel Number: 961-200.207 Job Address: 2303 Hendricks Street Zoning: R-II Type: V_N Occupancy: U_1 Total Occupant Load: 1 Nature of Work: Construct detached StoraEe/Shop Owner: Aumock Family Trust Contractor: Little & Little Construction - LITTLLC157C5 GENERAL CONDITIONS APPLY: See last aaee SEPARATE PERMITS REQUIRED: Electrical Permit -Contact WA State Dept. of Labor & Industries 360-417-2702 RF,t1TTTRF,>1 TNCPFCTTnNC A PPRl1VTi T m A TTi TEMP EROSION & SEDIMENT CONTROL See General Condition No. 2 Silt Fence as needed Drive Off Mat to restrict sediment from leaning the site ___ _ _-- See Correction Notice in File - FOOTIIYGSYFOUNDATIO~I'3~A~_ See Correction Notice in File ~ °` Setbacks ` Footings/ Foundations monolithic pour '~ `~ ~,; ~~~ .1i~6'ttade~slab ~~- s2~~ / ~. JJJ .1 ~ ~' ~~ ~~ Forms ~ 1 ~~ Reinforcement ` " ~ t Alternate Braced Walls ~ ~ ~ ~r Anchor Bolts 1 ' UFER ~ r -' " EXTERIOR SHEATHING See Correction Notice in File NOTE: Do not cover prior to inspection Brace Wall Panel Design Alternate Braced Wall Panel Design Building Permit #BLD03-259Rd FRAMING See Correction Notice in File Prescriptive & designed braced wall Danel sheathi~ ~' \ & nailing must be inspected prior to cover -- ~, y J ' ells _ ~ ~ Holddowns -per ABWP design Trusses -Engineered truss plan to be on-site at time of inspection Attic venting J Posts, beams and headers Positive connections cj _ / Weather Resistive Barrier , !~/) r INSULATION See Correction Notice in File Slab (R-10 ) Walls (R-13 Ceiling (R-21~ Baffles '~N~' See Correction Notice in File Public Works Sign-off House Numbers - 5" numbers Final -building GENERAL CONDITIONS ` 1. Contractors working on this project are required to have a Labor & Industries contractor's reeistration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESL) measures shall be installed on-site and inspected prior to beginning construction; ca11385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. Applicant is responsible for protection of adjacent properties. 3. All elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. C~ Building Permit #BLD03-259R-1 ~ 6. The Building Department is unable to pass final inspection on your project until Public • Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works aouroval ~~L- ~i®.:..:-J a t-< a-.:. ~-v-~- _ i~ ~9Y___N...:_. ~. s-..rte r. . • .•: 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. 9. Revisions require review and approval prior to making changes in the fteld. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. ~~