Loading...
HomeMy WebLinkAboutBLD03-249 • CITY OF PORT TOWNSEND CONSTRUCTION PERMIT & INSPECTION RECORD _. .~~ _ THIS CARD MU5T BE POSTED AT CONSTRUCTION SITE Ca11385-2294 for Inspection Permit Number: BLD03-249 Issued: 12/01/03 Parcel # 974-101-704 Job Address: 420 Reed Street Type: VV=N Occupancy: R-3 Total Occupant Load: No Chanee Nature of Work: Addition of 192 square feet for Kitchen and Laundry Room Owner: Bob Eneel Contractor: Troy Frutieer Home Crafting - TROYFHC98700 GENERAL CONDITIONS APPLY: See last 2 pages REOTTTRF,1) TNSPECTTONC A PPR (1VFT /il A TTi FOOTINGS Drill and Epoxy rebar into existing footings ~~ Prescriptive footing ~' ~ FOUNDATION ~ ~ Drill and epoxy into existing foundation f, '. Prescriptive foundation wall f Foundation vents- 4 FLOOR FRAMING I BCI engineering to be onsite for floor inspection `, Floorjoists - Ledger attachment ; EXTERIOR SHEATHING-do not cover prior to , inspection ' I Braced wall design Alternate braced wall design . ~. /' PLUMBING Rough-In (D-V-T & Clean outs) Water Supply Water Hammer- needs to be accessible Gas SuPP1Y <, j , Pipe Insulation (R-3) ` ~-.~ t r :~ti~ ,_ ~ .. 4. Building Permit #BLD03-249 MECHANICAL Source Specific Exhaust Fan @ kitchen(100cfm)& (laundry (SOcfm) LPG Downdraft stove- manufacturer's installation ~ manual to be onsite for inspection FRAMING Walls Beams and headers-verb load transfer to existing footing and foundation wall for GLB Positive connections Alternate Braced wall design hazdwaze Rafters-2x12's ~`~) Ledger attachment (/ Window U-factor - 0.35 or better NFRC sticker must be on windows at time of Inspection Air Seal n /' INSULATION R-38 @ ceilings/ R-30 in vault l j R-21 in wa ls /„ R-30 in floors 'I'// i DRYWALL NAILING Walls FINAL House Numbers - 5"numbers Insulation Certificate (if applicable) { Vapor Bazrier Paint Certificate (if applicable) ~,;/ Smoke Detectors throughout existing construction: one i each l i d i h /! ~ n s eep ng room an n eac area ~ L leading to sleeping rooms Final -LPG ~' ~ ~ Final -building ~ ~'( ;i `. GENERAL CONDITIONS I. Contractors working on this project are required to have a Labor & Industries contractor's registration number and a City business license. Failure to provide proof of this documentation prior to work may result in job shut down while this is accomplished. 2. Temporary erosion and sediment control (TESC) measures shall be installed on-site and inspected prior to beginning construction; call 385-2294. Measures shall include installation of silt fencing and graveled construction entrance (see attached details). Adjacent rights-of--way shall be kept free of dirt debris. Soils exposed during construction Building Permit kBLD03-7A9 shall be temporarily stabilized with mulching, plastic sheeting, etc. Soils shall be permanently stabilized with seeding, plantings, sodding, etc. once construction is complete. . Applicant is responsible for protection of adjacent properties. 3. Atl elements of engineering including nailing, holdowns, sheathing, and alternate braced wall panels (ABWP) require inspection prior to cover. 4. Owner or owner's agent shall review and oversee correction of any and all deficiencies noted by required inspections. 5. Re-inspection is required after inspection report corrections are completed. 6. The Building Department is unable to pass final inspection on your project until Public Works requirements have been completed and inspected. For Public Works inspection call 385-2294. A minimum of twenty-four hours notice is required. Public Works adaroval must be received prior to scheduline the Buildine Deaartment's final inspection. 7. Final Inspections are required prior to occupancy; A Certificate of Occupancy is required for anon-residential project. 8. All building permits expire if no progress has been made within six months, or if no inspections are done by the Building Department within one year. Call for at least one inspection per year to keep your building permit active. • 9. Revisions require review and approval prior to making changes in the field. Contact the Building Department at 379-5086 prior to making changes to the approved plans. 10. POST THIS PERMIT ON-SITE WITH THE APPROVED PLANS. •